Plan Review Details - Permit 07120631
Plan Review Stops For Permit 07120631
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status N Date 2009-02-19 Cont ID  
Sent By jwitmer Date 2009-01-07 Time 14:04 Rev Time 0.00
Received By efabian Date 2009-02-19 Time 12:39 Sent To ENG
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-10-31 Cont ID  
Sent By jwitmer Date 2008-10-31 Time 10:53 Rev Time 0.77
Received By jwitmer Date 2008-10-31 Time 10:17 Sent To PC
Notes
2008-10-31 11:07:58REV# 4 10-15-08 OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-05-29 Cont ID  
Sent By jwitmer Date 2008-05-29 Time 08:25 Rev Time 0.77
Received By jwitmer Date 2008-05-29 Time 08:25 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-01-25 Cont ID  
Sent By jwitmer Date 2008-01-25 Time 13:39 Rev Time 1.33
Received By jwitmer Date 2008-01-25 Time 13:39 Sent To  
Notes
2008-01-25 13:54:58BUILDING PLAN REVIEW
 PERMIT: 07120631
 ADD: 501 7TH ST
 CONT: RINKER MATERIALS OF FL
 TEL: (561)310-9902
  
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS,
 REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR
 REVIEW FOR PERMIT.
 IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF
 YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A
 THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID
 DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1*
 /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH
 ADMINISTRATIVE CODE.
  
 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE2007 SUPPLEMENTS.
  
 2) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION
 THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE
 OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PROJECT IS DESIGNED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
  
 3) PLEASE PROVIDE THE REQUIRED WIND DESIGN CRITERIA:
 1609.6.2 WIND DESIGN PROCEDURES
 1)THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE
 ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION.
  
 2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN
 ACCORDANCE WTIH SECTION1609.5.
  
 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4.
  
 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4)
  
  
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-10-28 Cont ID  
Sent By dpalmer Date 2008-10-28 Time 15:13 Rev Time 0.00
Received By dpalmer Date 2008-10-28 Time 15:13 Sent To PC
Notes
2008-10-28 15:13:52REV #2 REVISED LOCATIONS/SITE OF EQUIPMENT

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-07-03 Cont ID  
Sent By dpalmer Date 2008-07-03 Time 16:47 Rev Time 0.00
Received By dpalmer Date 2008-07-03 Time 16:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-05-04 Cont ID  
Sent By dpalmer Date 2008-05-04 Time 14:40 Rev Time 0.00
Received By dpalmer Date 2008-05-04 Time 14:40 Sent To  
Notes
2008-05-04 14:40:53** DENIED 2ND REVIEW**
  
 ** PLEASE SEE SOME ITEMS FROM PREVIOUS REVIEW ARE STILL
 IN NEED OF ADDRESSING.
  
 1) NOTE: PLEASE SEE PREVIOUS REVIEW NOTE #2 WHICH
 MENTIONED THAT THE CERTIFICATE OF AUTHORIZATION NUMBER
 AS REQUIRED PER FS 471.023 APPEARS TO STILL BE MISSING.
 THE RESPONSE FROM ONE OF THE DESIGN ENGINEERS STATE
 THAT WHEN AN INDIVIDUAL IS OPERATING UNDER HIS/HER OWN
 AND USING THEIR OWN PE NUMBER THAT A CA NUMBER IS NOT
 REQUIRED. THIS IS TRUE AND THIS OFFICE/REVIEW WAS AWARE
 OF THIS. THE COMMENT WAS NOT MADE WITHOUT REASON,
 PLEASE SEE THE ELECTRICAL SHEETS STILL CONTAIN A *TITLE
 BLOCK* OTHER THAN THE ENGINEER AS LISTED. HOW IS
 HOLLOWAY ELECTRICAL SERVICES INC AN INDIVIDUAL? IF THIS
 COMPANY IS LISTED ON TITLE BLOCKS AS THE DESIGNING FIRM
 THIS IS THE VERY REASON FOR THE PREVIOUS COMMENT AND
 THE VERY REASON WHY THIS COMMENT REMAINS.
 PLEASE KNOW THAT ANY PLANS/SHEETS WHICH CONTAIN
 COMPANIES WHICH ARE SHOWN TO BE PART OF THE DESIGN
 SHALL BE PROPERLY LICENSED UNDER THE FLORIDA STATUTES.
  
 2) NOTE: PLEASE KNOW WIND LOAD CALCULATIONS WILL NEED
 TO BE PROVIDED, SIGNED, DATED AND SEALED.
 REVIEW WILL BE DONE BY BUILDING REVIEWER.
 FBC 106.1.2 FOR ADDITIONAL INFORMATION.
  
 3) NOTE: PLEASE SEE PREVIOUS REVIEW NOTE WITH RESPECT
 TO THE INDICATION OF THE AIC RATINGS FOR ALL
 EQUIPMENT/BREAKERS. THE RESPONSE MENTIONS *TO SEE PANEL
 BOARD SCHEDULES IN ELECTRICAL PLANS*.
 FOR EXAMPLE:
 PANEL 17PL INDICATES THE BRANCH BREAKER RATINGS,
 HOWEVER WHERE ARE THE RATINGS FOR MAIN DISCONNECT,
 BREAKER AT MDP ETC.
 110.9, 110.3.
 FBC 106.1.2, 106.3.5.1.2 FOR COORDINATION AND
 ADDITIONAL INFORMATION.
  
 4) NOTE: PLEASE KNOW ONLY ONE SET OF PREVIOUSLY
 REVIEWED PLANS NEED BE SUBMITTED. BOTH OLD/VOIDED SETS
 WERE SUBMITTED BACK WITH NEW PLANS.
 THIS IS FOR INFORMATION ONLY.
  
 ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY
 COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE
 DO NOT HESITATE IN CONTACTING THIS OFFICE.
 PLEASE SEE BELOW FOR CONTACT INFORMATION.
  
 ** IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-12-30 Cont ID  
Sent By dpalmer Date 2007-12-30 Time 16:21 Rev Time 0.00
Received By dpalmer Date 2007-12-30 Time 16:21 Sent To  
Notes
2007-12-30 16:21:29 
 *** DENIED REVIEW ***
  
 1) NOTE: PLEASE BE SURE THE ELECTRICAL PLANS CONTAIN
 THE FOLLOWING CODE STATED ON PLANS FOR RELEVANT
 DESIGN.
 2005 NFPA-70
  
 2) NOTE: PLEASE SEE MISSING INFORMATION FOR TITLE
 BLOCKS FOR ELECTRICAL ENGINEERING FIRM OF RECORD.
 PLEASE SEE MISSING CERTIFICATE OF AUTHORIZATION NUMBER
 AS REQUIRED PER FS 471.023 AND FAC 61G15-23.002.
  
 3) NOTE: PLEASE BE SURE TO INCLUDE ADDRESS OF APPLIED
 PROJECT ON ALL SHEETS. PLEASE KNOW THE APPLIED ADDRESS
 IS 501 7TH ST.
 FBC 106.1.2, 106.5 ETC
  
 4) NOTE: PLEASE CLARIFY WHAT APPEAR TO BE TWO DIFFERENT
 SYSTEM VOLTAGES IN THE GUTTER ON 1-E-1CR.
 PLEASE SEE FOR EXAMPLE PANEL 17PL SHOWS CONNECTION
 POINTS FROM TRANSFORMER AND GUTTER. THIS GUTTER
 THERE-FORE SHOWS ELECTRICAL FROM TWO SYSTEMS.
 PLEASE PLACE NOTE ON PLANS FOR CONDUCTORS PER 300.3C.
  
 5) NOTE: PLEASE SUBMIT WIND LOAD FOR LIGHT POLES FOR
 FBC 140MPH.
 THE ENGINEERING CALCULATIONS WILL BE REVIEWED BY THE
 BUILDING REVIEWER.
 ** THIS IS NOTED FOR INFORMATION REQUIRED**
  
 6) NOTE: PLEASE BE SURE TO INDICATE AIC RATINGS FOR ALL
 ELECTRICAL SERVICE EQUIPMENT.
 110.3
  
 7) NOTE: PLEASE PROVIDE LOAD CALCULATIONS FOR THE
 EXISTING MDP WHICH NEW ELECTRICAL LOADS ARE BEING FED
 FROM.
 220
 FBC 106.3.5.1.2
  
  
  
 ** PLEASE BE SURE TO ADDRESS COMMENTS AND IF THERE ARE
 ANY QUESTIONS, PLEASE CONTACT THIS REVIEWER.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 5 Status P Date 2009-02-27 Cont ID  
Sent By mgonzale Date 2009-02-27 Time 15:41 Rev Time 1.00
Received By mgonzale Date 2009-02-27 Time 09:16 Sent To  
Notes
2009-02-27 09:20:00*** PASSED ***
  
 MET WITH FIELD SUPER REVIEWED THEIR CONSTRUCTION
 CAPPING. ALL SATISFACTORY!
  

Review Stop ENG ENGINEERING CSD
Rev No 4 Status N Date 2009-02-19 Cont ID  
Sent By efabian Date 2009-02-19 Time 12:43 Rev Time 0.00
Received By efabian Date 2009-02-19 Time 12:43 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2008-07-03 Cont ID  
Sent By efabian Date 2009-02-19 Time 12:40 Rev Time 0.00
Received By rchokshi Date 2008-07-03 Time 14:37 Sent To  
Notes
2008-07-03 14:38:36MOCK-ROOS LETTER, SEE E-MAIL FROM MANNY G6/27/08
 STABILIZATION BOND, SEE E-MAIL FROM MANNY G. 5/12/08 &
 6/10/08, APPROVED BY BRIAN MOREE

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2008-05-09 Cont ID  
Sent By rchokshi Date 2008-05-09 Time 13:48 Rev Time 0.00
Received By rchokshi Date 2008-05-09 Time 13:27 Sent To  
Notes
2008-05-09 13:48:10FAILED FOR FOLLOWING REASONS:
  
 1. YOUR NOTICE OF INTENT (NOI). IS O.K.
  
 2. PLEASE SHOWSILT FENCE AROUND THE WHOLE SITE NOT
 JUSTPARTIAL SITE.
  
 3. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO.
 4060-07:
  
 ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH
 EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY
 APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE
 FOLLOWING:
  
 1. EROSION CONTROL, AND
 2. LAND STABILIZATION
  
 THE AMOUNT OF THE EROSION CONTROL AND LAND
 STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER
 OF RECORD USING THE CURRENT CITY COST SCHEDULE AND
 VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT.
 PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION
 SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION.
  
 UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN
 FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL
 TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE
 MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS.
  
 A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM
 THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR.
  
 4. PLEASEPROVIDE STORM WATER QUALITYCALCULATION &
 GEOTECH REPORT TO 45 STREET, MR. JONATHAN BRAMLEY,P.E.
 DIRECTOR,ENGINEERING SERVICES FOR THEIR APPROVAL
 BEFORE WE ISSUE A PERMIT.PLEASE MAKE SURE YOU INCLUDE
 IN CALCULATION THAT YOU HAVE CONSIDERED FLOOD ZONE
 AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA AND CROWN OF
 THE ROAD WHEN YOU DETERMINE THE FIRST FLOOR ELEVATION.
 FIRST FLOOR ELEVATION SHOULD BE ATLEAST 1 FOOT HIGHER
 THAN HIGHEST CROWN OF THE ROAD.
  
 PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR
 PERMITTING PROCESS
  
 RASIK CHOKSHI805-6723

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2008-01-07 Cont ID  
Sent By rchokshi Date 2008-01-07 Time 11:34 Rev Time 0.00
Received By rchokshi Date 2008-01-07 Time 11:29 Sent To  
Notes
2008-01-07 11:34:41FAILED FOR FOLLOWING REASONS:
  
 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI).
 PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR
 NOI.
 YOU CAN GET NOI INFO FROM
 WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/
 NOTICE OF INTENT DEP FORM 62-621.300(4)(B),
 EFFECTIVE MAY 1, 2003
  
 2. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION
 DETAILS,CLOTHES USED FOR SILT FENCE ETC., PLANS SHOWING
 SILT FENCE AROUND THE SITE & STORM CATCH BASIN DRAINS
 DURING CONSTRUCTION AND ALL DEMOLITION PHASE.HEIGHT
 OF FENCE SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST
 PARTICLES.
  
 3. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO.
 4060-07:
  
 ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH
 EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY
 APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE
 FOLLOWING:
  
 1. EROSION CONTROL, AND
 2. LAND STABILIZATION
  
 THE AMOUNT OF THE EROSION CONTROL AND LAND
 STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER
 OF RECORD USING THE CURRENT CITY COST SCHEDULE AND
 VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT.
 PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION
 SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION.
  
 UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN
 FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL
 TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE
 MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS.
  
 A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM
 THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR.
  
 4. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR
 SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP
 PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FOR ALL
 CITY STANDARDS NOTES FROM 1000, 45 STREET, ENGINEERING
 SERVICES, PHONE# 494-1040
  
 5. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE
 DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION
 MUST BE ACCESSIBLE FOR PICKUP TRUCK.
  
 6. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED
 FLOOD ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA
 AND CROWN OF THE ROAD WHEN YOU DETERMINE THE FIRST
 FLOOR ELEVATION. FIRST FLOOR ELEVATION SHOULD BE
 ATLEAST 1 FOOT HIGHER THAN HIGHEST CROWN OF THE ROAD.
  
 7. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA,
 GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREAYOU
 ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE
 THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH
 AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE
 PROVIDE A COPY OF THESE CALCULATIONS.
  
 8. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE
 SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM
 ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE
 CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING
 ELEVATION, ETC ON DRAWINGS, CALCULATION FOR
 EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET
 DETENTION AREAS IN STORM WATER CALS IF YOU HAVE ALL
 THESE. PLEASE RESUBMIT GEO-TECH REPORT AND ALL
 ENVRONMENTAL REPORT.
  
 9. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND
 YOUR SITE FOR STORM WATER DRAIN SO YOUR SITE DO NOT GET
 FLOODED AND HAVE ENOUGH DRAINS.
  
 10. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, GEO-TECH
 REPORT&STORM WATER QUALITY CALCULATIONS. STORM
 WATER CALS MUST BE APPROVED FROM 100045TH STREET
 ENGINEERING SERVICES BEFORE WE APPROVED.
  
  
 PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR
 PERMITTING PROCESS
  
 RASIK CHOKSHI805-6723

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-05-23 Cont ID  
Sent By mawillia Date 2008-05-23 Time 16:06 Rev Time 0.00
Received By mawillia Date 2008-05-23 Time 15:35 Sent To  
Notes
2008-05-23 16:02:55*****APPROVED*****
  
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED;PLAN SHEET 1-SP-1 STAMPED, INITIALED,
 AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-01-07 Cont ID  
Sent By mwennerg Date 2008-01-07 Time 14:17 Rev Time 0.00
Received By mwennerg Date 2008-01-07 Time 14:17 Sent To  
Notes
2008-01-07 14:26:20***DENIED***
  
 1) ADDRESS TO BE PROVIDED IN TITLE BLOCK OF ALL
 SUBMITTED SHEETS FOR REVIEW.
  
 2) EQUIPMENT SHALL NOT INTERFERE OR HINDER EMERGENCY
 VEHICLE ACCESS PER NFPA 1, 2003 EDITION CHAPTER-18.
  
 3) PLEASE CLEARLY INDICATE LOCATION OF ALL FIRE
 HYDRANTS IN REFERENCE TO PROPERTY.
  
 4) MINIMUM 2A-10B,C RATED FIRE EXTINGUISHERS SHALL BE
 MOUNTED AND AVAILABLE.
  
 5) PLEASE INCLUDE ALL APPROPRIATE CODES AND ADOPTED
 EDITIONS REGARDING STRUCTURE AND ASSOCIATED STORAGE.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2009-01-06 Cont ID  
Sent By adarroug Date 2009-01-06 Time 15:56 Rev Time 0.00
Received By adarroug Date 2009-01-06 Time 15:56 Sent To B
Notes
2009-01-06 15:56:52TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-10-21 Cont ID  
Sent By adarroug Date 2008-10-21 Time 15:15 Rev Time 0.00
Received By adarroug Date 2008-10-21 Time 15:15 Sent To E
Notes
2008-10-21 15:15:55TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-10-21 Cont ID  
Sent By adarroug Date 2008-10-21 Time 15:10 Rev Time 0.00
Received By adarroug Date 2008-10-21 Time 15:10 Sent To P
Notes
2008-10-21 15:11:08TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-10-21 Cont ID  
Sent By adarroug Date 2008-10-21 Time 09:28 Rev Time 0.00
Received By adarroug Date 2008-10-21 Time 09:28 Sent To  
Notes
2008-10-21 13:53:30TO "COMM" BD#51
2008-10-21 09:29:10WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-06-16 Cont ID  
Sent By adarroug Date 2008-06-16 Time 14:27 Rev Time 0.00
Received By adarroug Date 2008-06-16 Time 14:27 Sent To  
Notes
2008-06-16 14:28:04TO "COMM" BD#63

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-04-24 Cont ID  
Sent By adarroug Date 2008-04-24 Time 16:13 Rev Time 0.00
Received By adarroug Date 2008-04-24 Time 16:13 Sent To  
Notes
2008-04-24 16:18:10TO "COMM" BD#57

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-04-24 Cont ID  
Sent By adarroug Date 2008-01-25 Time 16:11 Rev Time 0.00
Received By adarroug Date 2007-12-28 Time 16:28 Sent To  
Notes
2007-12-28 16:29:07COMM BOARD # 20

Review Stop P PLUMBING
Rev No 5 Status F Date 2008-11-05 Cont ID  
Sent By kstevens Date 2008-11-05 Time 17:57 Rev Time 0.00
Received By kstevens Date 2008-11-05 Time 17:57 Sent To  
Notes
2008-11-05 18:05:25REVISION DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. SHT1-P-2 NO NEW REVISION NUMBER INDICATED IN THE
 REVISION INDEX. NO REVISION INDICATED ON THE PLANS. ALL
 REVISIONS SUBMITTED FOR PUBLIC RECORD SHALL BE CLOUDED
 AND INDICATED WITH A REVISION NUMBER THAT IS AFTER THE
 LAST REVISION SUBMITTED AND REVIEWED. SECTION 106.1.3.
  
 2. SHT 17-P-1 REVISION ONE ON SHEET PREVIOUSLY REVIEWED
 AND ON FILE AT THIS OFFICE IS INDICATED AS "ADDED SITE
 ADDRESS" AND WAS SIGNED, SEALED AND DATED 2-5-08. A NEW
 REVISION NUMBER SHALL BE SUBMITTED WITH EACH NEW
 REVISION. THE PLAN SUBMITTED SHALL INDICATE THE
 REVISION SUBMITTED WITH A CLOUD AND THE NEW REVISION
 NUMBER THAT CORRELATES WITH THE NEW REVISION NUMBER IN
 THE REVISION INDEX. SECTION 106.1.3.
  
 3. SHT 17P-2 REVISION ONE ON SHEET PREVIOUSLY REVIEWED
 AND ON FILE AT THIS OFFICE IS INDICATED AS "ADDED SITE
 ADDRESS" AND WAS SIGNED, SEALED AND DATED 2-5-08. A NEW
 REVISION NUMBER SHALL BE SUBMITTED WITH EACH NEW
 REVISION. THE PLAN SUBMITTED SHALL INDICATE THE
 REVISION SUBMITTED WITH A CLOUD AND THE NEW REVISION
 NUMBER THAT CORRELATES WITH THE NEW REVISION NUMBER IN
 THE REVISION INDEX. SECTION 106.1.3.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-11-05 Cont ID  
Sent By kstevens Date 2008-11-05 Time 17:56 Rev Time 0.00
Received By kstevens Date 2008-11-05 Time 17:56 Sent To  
Notes
2008-11-05 17:57:05REVISION OK -- SHT 1-P-1

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-07-15 Cont ID  
Sent By kstevens Date 2008-07-15 Time 10:26 Rev Time 0.00
Received By kstevens Date 2008-07-15 Time 10:26 Sent To  
Notes
2008-07-15 10:27:05PASSED/PROVISO:PVC NOT APPROVED FOR COMPRESSED AIR
 SYSTEM.

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-05-10 Cont ID  
Sent By kstevens Date 2008-05-10 Time 07:08 Rev Time 0.00
Received By kstevens Date 2008-05-10 Time 07:08 Sent To  
Notes
2008-05-10 07:08:40PASSED/PROVISO:PVC NOT APPROVED FOR COMPRESSED AIR
 SYSTEM.

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-01-22 Cont ID  
Sent By kstevens Date 2008-01-22 Time 08:42 Rev Time 0.00
Received By kstevens Date 2008-01-17 Time 16:59 Sent To  
Notes
2008-01-22 09:41:35DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. PLEASE INDICATE THE CODES THE PLANS WERE DESIGNED
 TO. (FBC-2004 W/2007 AMENDMENTS)
  
 2. PLEASE INDICATE THE ADDRESS IN THE TITLE BLOCK OF
 EACH SHEET. SECTION 106.1.1.
  
 3. PER MANUF. INSTALLATION INSTRUCTIONS, ALL PVC
 PIPING/FITTINGS EXPOSED TO DIRECT UV RAYS SHALL BE
 PROTECTED. PLEASE INDICATE METHOD. SECTION 303.2.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 4 Status P Date 2008-10-31 Cont ID  
Sent By aaponte Date 2008-10-31 Time 09:51 Rev Time 0.00
Received By aaponte Date 2008-10-31 Time 09:51 Sent To  
Notes
2008-10-31 09:52:11PROVISO: FENCE SURROUNDING THE PROPERTY SHALL NOT
 EXCEED 6 FEET IN HEIGHT, INCLUDING CURB.
 PROVISO INLCUDED IN PREVIOUS REVIEW IS STILL IN EFFECT.

Review Stop Z ZONING
Rev No 3 Status P Date 2008-07-01 Cont ID  
Sent By aaponte Date 2008-07-01 Time 09:14 Rev Time 0.00
Received By aaponte Date 2008-07-01 Time 09:14 Sent To  
Notes
2008-07-01 09:15:43PROVISO: FOR MAINTENANCE PURPOSES, LANDSCAPE ALONG WEST
 RAILROAD AVENUE SHALL BE MOVED BACK NEXT TO THE FENCE,
 AND SOD SHALL BE PLANTED NEXT TO THE SIDEWALK.

Review Stop Z ZONING
Rev No 2 Status F Date 2008-05-08 Cont ID  
Sent By aaponte Date 2008-05-08 Time 10:54 Rev Time 0.00
Received By aaponte Date 2008-05-08 Time 10:54 Sent To  
Notes
2008-05-08 10:56:09CLASS B SPECIAL USE PERMIT APPROVAL BY DAC IS REQUIRED
 BEFORE A PERMIT CAN BE APPROVED BY ZONING.

Review Stop Z ZONING
Rev No 1 Status F Date 2008-01-09 Cont ID  
Sent By aaponte Date 2008-01-09 Time 15:57 Rev Time 0.00
Received By aaponte Date 2008-01-09 Time 15:57 Sent To  
Notes
2008-01-09 16:00:321. UNITY OF TITLE SHALL BE PROVIDED FOR PROJECT (ROW
 ABANDONMENT OF REVOCABLE PERMIT REQUIRED)
 2. EXISTING USE IS CONSIDER AS OUTDOOR STORAGE AND
 DISPOSAL OF MATERIALS. AS SUCH, SCREENING SHALL BE
 PROVIDED. PLEASE CONTACT PLANNING DEPARTMENT TO
 DETERMINE APPROPRIATE SCREENING FOR THE SITE.