Plan Review Details - Permit 07120627
Plan Review Stops For Permit 07120627 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-01-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-01-15 |
Time |
07:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-01-15 |
Time |
07:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-01-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-01-09 |
Time |
07:37 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-01-09 |
Time |
07:13 |
Sent To |
|
|
Notes |
2008-01-09 08:08:02 | 2004 FBC W/2007 REVISIONS | | BATH REMODELROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] | | | | DENIED BY BUILDING | | | | 1)A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) SPECIFY THE APPLICABLE CODE UNDER WHICH THE PROJECT | | HAS BEEN DESIGNED (2004 FBC W/2007 REVISIONS). | | | | 3) SPECIFY TEMPERED GLASS AT THE NEW SHOWER ENCLOSURE | | AS REQUIRED BY FBC R 308.3. | | | | 4) SHOW COMPLIANCE WITH FBC R307.2 BATHTUB AND SHOWER | | SPACES. | | BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH | | INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL | | BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL | | SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 | | FEET (1829 MM) ABOVE THE FLOOR. | | | | 5) COMPLY WITH COMMENTS OF OTHER REVIEWERS. | | | | -ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-01-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-11 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-01-11 |
Time |
10:26 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-01-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-12-31 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-12-31 |
Time |
12:43 |
Sent To |
P |
|
Notes |
2007-12-31 12:52:44 | | | | | 1} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE | | PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI | | PROTECTED PER 210.8(A) (1). | | | | 2} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. | | WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE | | ALARMS SHALL BE INTERCONNECTED AND HARD WIRED.INDICATE | | SAME ON PLANS, SHOW LOCATIONS OR MAKE A NOTE. | | | | 3} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | PRINT AND SIGN THEIR NAME TO SAME, ALL SHEETS, PER | | 106.1.3.FBC. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-01-10 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2008-01-10 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2008-01-10 |
Time |
09:01 |
Sent To |
E |
|
Notes |
2008-01-10 09:01:28 | TO BILL TROBAUGHS DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-01-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-01-09 |
Time |
07:37 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-12-27 |
Time |
15:39 |
Sent To |
|
|
Notes |
2007-12-27 15:39:23 | TO SFR "E" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2007-12-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-12-27 |
Time |
16:06 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-12-27 |
Time |
16:06 |
Sent To |
E |
|
Notes |
2007-12-27 16:07:26 | NO MECHANICAL PLANS SUBMITTED, AND NO | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | THIS TIME. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-01-11 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-11 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-11 |
Time |
16:34 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-01-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-02 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-04 |
Time |
14:31 |
Sent To |
B |
|
Notes |
2008-01-04 14:33:28 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | PLUMBING PLAN REVIEW: | | DENIED: | | | | 1. PLEASE SHOW COMPLIANCE WITH THE FOLLOWING FOR THE | | SHOWER ON THE RESUBMITTAL. | | A} 417.4.1 WALL AREA. | | THE WALL AREA ABOVE BUILT-IN TUBS WITH INSTALLED SHOWER | | HEADS AND IN SHOWER COMPARTMENTS SHALL BE CONSTRUCTED | | OF SMOOTH, NONCORROSIVE AND NONABSORBENT WATERPROOF | | MATERIALS TO A HEIGHT NOT LESS THAN 6 FEET (1829 MM) | | ABOVE THE ROOM FLOOR LEVEL, AND NOT LESS THAN 70 INCHES | | (1778 MM) WHERE MEASURED FROM THE COMPARTMENT FLOOR AT | | THE DRAIN. SUCH WALLS SHALL FORM A WATER-TIGHT JOINT | | WITH EACH OTHER AND WITH EITHER THE TUB, RECEPTOR OR | | SHOWER FLOOR. | | | | B} 424.3 SHOWER VALVES. | | SHOWER AND TUB-SHOWER COMBINATION VALVES SHALL BE | | BALANCED PRESSURE, THERMOSTATIC OR COMBINATION | | BALANCED-PRESSURE/THERMOSTATIC VALVES THAT CONFORM TO | | THE REQUIREMENTS OF ASSE 1016 OR CSA B125. | | | | 2. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING | | DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE | | PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE | | ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER | | SECTION *106.3.4.3. | | IF THE DESIGN PROFESSIONAL IS AN ARCHITECT OR | | ENGINEER, THEN HE OR SHE SHALL AFFIX HIS OR HER | | OFFICIAL SEAL, SIGNATURE AND DATE TO SAID DRAWINGS, PER | | FLORIDA STATUTES 481 AND 471 RESPECTIVELY. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
|