Plan Review Stops For Permit 07120574 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-02-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-02-26 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-02-26 |
Time |
13:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-02-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-02-20 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-02-20 |
Time |
07:20 |
Sent To |
|
|
Notes |
2008-02-20 08:22:07 | REVISION TO REPLACE 9 WINDOWS | | | | DENIED BY BUILDING | | | | 1) THE ORIGINAL PLANS WERE SIGNED AND SEALED BY AN | | ENGINEER (GORDON BUCK). AS THE DESIGNER OF RECORD, HE | | IS REQUIRED TO SIGN AND SEAL THE REVISED FLOOR PLANS | | WITH THE WINDOW CHANGE OUT. FS 471 | | | | 2) THE DESIGNER OF RECORD IS REQUIRED TO REVIEW THE | | PRODUCT APPROVALS AND APPROVE THEM IN WRITING. FBC | | 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE PRODUCT | | WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 3) THE VALUE OF THE ADDITIONAL SCOPE OF WORK IS | | REQUIRED TO BE ADDED TO THE ORIGINAL VALUE OF THE | | PERMITTED WORK AND THE ADDITIONAL PERMIT FEES TO BE | | PAID. FBC 108.1* CITY AMENDMENTS | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-01-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-01-29 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-01-29 |
Time |
16:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-01-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-01-08 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-01-08 |
Time |
16:28 |
Sent To |
|
|
Notes |
2008-01-08 16:43:49 | 2004 W/2007 REVISIONS | | | | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) THE DESIGN PARAMETERS ON SHEET 1.1 INCORRECTLY LIST | | THE BUILDING AS OPENED. THE BUILDING IS ENCLOSED. | | PLEASE CORRECT. SEE ASCE 7-02 FOR DEFINITIONS OF OPEN | | AND ENCLOSED STRUCTURES. | | | | 3) SHOW COMPLIANCE WITH FBC EXISTING BUILDINGS SECTION | | 604.4.3 FOR SMOKE ALARMS. | | | | 4) ON SHEET 1.2, DETAIL D SPECIFIES (3) ANCHOR BOLTS | | AND A 12" X 12" BASE PLATE. HOWEVER DETAILS A, B AND C | | SPECIFY (4) ANCHOR BOLTS AND A 10" X 10" BASE PLATE. | | PLEASE CLARIFY. FBC 106.1.1* CITY AMENDMENTS. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-05-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-05-12 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-05-12 |
Time |
09:27 |
Sent To |
PC |
|
Notes |
2008-05-12 09:28:14 | | | | | | | PLUMBIN REV, RESTAMP ELEC./WRT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-01-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-28 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-01-28 |
Time |
11:39 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-12-31 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-12-31 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-12-31 |
Time |
07:11 |
Sent To |
Z |
|
Notes |
2007-12-31 08:11:13 | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | ALL COMMENTS RELATE TO SHEET E-1 , UNLESS OTHERWISE | | NOTED. ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS | | OTHERWISE NOTED. | | | | 1} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, | | METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED | | FOR THE FEED FOR THE NEW PANEL. | | | | 2} THE ELECTRICAL NOTE ON E-1 INDICATES A NEW SERVICE | | IS TO BE INSTALLED. IF SO PROVIDE A RISER DIAGRAM PER | | 215.5. AND AIC RATING OF THE EQUIPMENT PER 110.9-10. | | THE NOTE ON THE "PANEL/LOAD CALCULATION" INDICATES AN | | EXISTING 150 AMP PANEL. PLEASE CORRELATE TO INDICATE | | PROPOSED WORK. THERE IS NO MENTION OF ELECTRICAL WORK | | ON THE APPLICATION. | | | | 3} THE LOCATION OF THE NEW WATER HEATER DOES NOT COMPLY | | WITH THE CLEARANCE REQUIREMENTS OF 110.26 DUE TO THE | | LOCATION OF THE WASHER UNDER IT. | | | | 4} THE BATH CIRCUIT IS REQUIRED TO BE A 20 AMP CIRCUIT | | WITH #12 CONDUCTORS PER 210.11(C) (3), | | | | 5} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. | | WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE | | ALARMS SHALL BE INTERCONNECTED AND HARD WIRED.LOCATE | | SAME ON THE PLANS, INDICATE IF EXISTING OR NEW WORK. | | | | 6} NOTE #4 INDICATES ALL CONDUCTORS MUST BE #12. | | CIRCUITS 22 AND 24 ARE LISTRD AS #15. CORRELATE SAME. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2007-12-26 |
|
|
Cont ID |
|
Sent By |
ssherman |
Date |
2007-12-26 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
ssherman |
Date |
2007-12-26 |
Time |
15:57 |
Sent To |
|
|
Notes |
2007-12-26 15:58:43 | HISTORICAL APPROVAL PER FRIEDERIKE MITTNER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-05-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-05-07 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-05-07 |
Time |
14:37 |
Sent To |
P |
|
Notes |
2008-05-07 14:40:00 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-04-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-23 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-23 |
Time |
10:24 |
Sent To |
P |
|
Notes |
2008-04-23 10:25:09 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-02-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-21 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-21 |
Time |
14:20 |
Sent To |
B |
|
Notes |
2008-02-21 14:21:12 | TO "RMCDOUGAL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-02-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-15 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-15 |
Time |
11:14 |
Sent To |
B |
|
Notes |
2008-02-15 11:14:25 | TO "RMCDOUGAL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-01-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-23 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-23 |
Time |
09:55 |
Sent To |
E |
|
Notes |
2008-01-23 09:55:42 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-01-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-01-08 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-12-26 |
Time |
16:07 |
Sent To |
|
|
Notes |
2007-12-26 16:08:09 | TO SFR "E" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2007-12-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-12-27 |
Time |
16:00 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-12-27 |
Time |
16:00 |
Sent To |
E |
|
Notes |
2007-12-27 16:01:40 | NO MECHANICAL PLANS SUBMITTED, AND NO | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | THIS TIME. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2008-05-12 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-05-12 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-05-12 |
Time |
08:34 |
Sent To |
E |
|
Notes |
2008-05-12 08:38:50 | REVISION SHEET E-1: "OK" SWAPPED LOCATIONS WITH THE MOP | | SINK AND WASHING MACHINE. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2008-04-25 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-04-25 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-04-25 |
Time |
09:11 |
Sent To |
PC |
|
Notes |
2008-04-25 09:43:06 | PLUMBING PLAN REVIEW: | | REVISION DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE RELOCATION OF THE WASHING MACHINE AND LAUNDRY TRAY | | IS CONSIDERED AS NEW WORK AND THE SUBMITTED REVISION | | SHEET E-1 IS NOT COMPLIANT PER THE FOLLOWING. | | | | 1. THE WASHING MACHINE SHALL CONNECT TO A BRANCH DRAIN | | OR STACK A MINIMUM OF 3 INCHES. PER FBC-2004 PLUMBING | | SECTION 406.3. WASTE CONNECTION. | | | | 2. THE CLEANOUT FOR THE WASHING MACHINE STACK SHALL BE | | 3 INCH. PER FBC-2004 PLUMBING SECTION 708.7 MINIMUM | | SIZE. | | | | 3. THE CLEANOUT FOR THE WASHING MACHINE SHALL BE | | CLEARLY INDICATED AS BEING 4' A.F.F. PER FBC-2004 | | PLUMBING SECTION 708.9 ACCESS. | | | | 4. NOTE: THE INDICATED RUBBER COUPLING IS NOT | | COMPLIANT AS A JOINT BETWEEN DIFFERENT MATERIALS. | | CLEARLY INDICATE THIS TYPE OF CONNECTION PER FBC-2004 | | PLUMBING SECTION 705.16 JOINTS BETWEEN DIFFERENT | | MATERIALS. | | JOINTS BETWEEN DIFFERENT PIPING MATERIALS SHALL BE MADE | | WITH A MECHANICAL JOINT OF THE COMPRESSION OR | | MECHANICAL-SEALING TYPE CONFORMING TO ASTM C 1173, ASTM | | C 1460 OR ASTM C 1461. CONNECTORS AND ADAPTERS SHALL BE | | APPROVED FOR THE APPLICATION AND SUCH JOINTS SHALL HAVE | | AN ELASTOMERIC SEAL CONFORMING TO ASTM C 425, ASTM C | | 443, ASTM C 564, ASTM C 1440, ASTM D 1869, ASTM F 477, | | CAN/CSA A257.3M OR CAN/CSA B602. | | | | 5. THE VALUE FOR THE JOB SHALL BE INCREASED FOR THE | | PROPOSED NEW WORK AND THE DIFFERENCE PAID BEFORE THE | | NEXT REVISION BEING RESUBMITTED FOR PLAN REVIEW. PER | | (W.P.B. AS AMENDED) SECTION 108.3 BUILDING PERMIT | | VALUATION. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | EXAMINER FOR REFERENCE FOR THE | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2008-01-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-04 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-04 |
Time |
13:52 |
Sent To |
B |
|
Notes |
2008-01-04 14:02:58 | NO PLUMBING PERMIT HAS BEEN APPLIED FOR AT THIS TIME, | | HOWEVER A PLUMBING PERMIT WILL BE REQUIRED FOR THE | | INSTALLATION OF THE NEW ELECTRIC TANKLESS WATER | | HEATER./MRP. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2007-12-31 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-12-31 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-12-31 |
Time |
09:21 |
Sent To |
P |
|
Notes |
2007-12-31 09:22:36 | ***APPROVED*** | | | | | | SENT TO "P" - METAL RACK |
|
|