Plan Review Details - Permit 07120558
Plan Review Stops For Permit 07120558
Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-12-31 Cont ID  
Sent By mperson Date 2007-12-31 Time 10:31 Rev Time 0.00
Received By mperson Date 2007-12-21 Time 16:31 Sent To P
Notes
2007-12-21 16:31:19TO PLUMBING BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-12-31 Cont ID  
Sent By mperson Date 2007-12-31 Time 10:31 Rev Time 0.00
Received By mperson Date 2007-12-31 Time 10:18 Sent To  
Notes
2007-12-31 10:31:06****************PROVISO****************
 A} PROTECTION FOR THE DOCK HOSE BIBBS REQUIRED PER THE
 FOLLOWING.
 608.15.4.2 HOSE CONNECTIONS.
 SILLCOCKS, HOSE BIBBS, WALL HYDRANTS AND OTHER OPENINGS
 WITH A HOSE CONNECTION SHALL BE PROTECTED BY AN
 ATMOSPHERIC-TYPE OR PRESSURE-TYPE VACUUM BREAKER OR A
 PERMANENTLY ATTACHED HOSE CONNECTION VACUUM BREAKER.
  
 B} NOTE: THE INDICATED SLEEVE UNDER STREET BY OTHERS
 REQUIRES A "RIGHT OF WAY PERMIT". PLEASE CONTACT WINDEL
 G. PALMER, UTILITIES ENGINEER PROJECT COORDINATOR,
 ENGINEERING SERCICES DEPARTMENT. PHONE: (561) 494-1040
 EXT:1086, FOR INFORMATION ABOUT THIS PERMIT.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]
  
  