Plan Review Details - Permit 07120516
Plan Review Stops For Permit 07120516 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-05-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-05-15 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-05-15 |
Time |
15:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-05-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-05-05 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-05-05 |
Time |
15:08 |
Sent To |
|
|
Notes |
2008-05-05 15:10:22 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.A SPAN OF 97", 84.86 PSF, REQUIRES USE OF THE 9' | | COLUMN, 105PSF ROW.PLEASE REVISE ANCHOR SPACING. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-02-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-02-14 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-02-14 |
Time |
13:26 |
Sent To |
|
|
Notes |
2008-02-14 13:27:44 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.THE CORRECT ASCE REFERENCE IS ASCE7-02; ASCE7-05 | | CANNOT BE USED UNTIL INCORPORATED INTO FBC CHAPTER 35. | | | | 2.PLEASE PROVIDE CALCULATIONS FOR THE DESIGN PRESSURE | | SPECIFIED OF -50.8, 280' HIGH BUILDING, EXPOSURE C, | | 213SF OPENING. | | | | 3.DOCUMENTS PREPARED BY AN ARCHITECT ARE TO CONTAIN | | ALL INFORMATION REQUIRED BY FAC61G1-16.003,004. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-12-31 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-12-31 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-12-31 |
Time |
09:32 |
Sent To |
|
|
Notes |
2007-12-31 09:33:51 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | _XX_1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT | | OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. | | | | _XX_2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED. | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | R310. | | | | ____6.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | ABOVE. | | | | ____8.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), | | FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE | | C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | R301.2.1.4. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-05-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-05-01 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-05-01 |
Time |
10:48 |
Sent To |
B |
|
Notes |
2008-05-01 10:48:36 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-12-31 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-12-31 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-12-20 |
Time |
17:16 |
Sent To |
|
|
Notes |
2007-12-20 17:17:01 | SENT TO MISC BOX # 01 MMILLER |
|
|
|