Plan Review Details - Permit 07120438
Plan Review Stops For Permit 07120438
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-02-01 Cont ID  
Sent By rbrown Date 2008-02-01 Time 08:50 Rev Time 0.00
Received By rbrown Date 2008-02-01 Time 08:50 Sent To  
Notes
2008-02-01 08:51:40CONTRACTOR OPTED TO USE POLYSTICK FOR SECONDARY WATER
 BARRIER ON BOTH SLOPE AND FLAT ROOFS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2008-01-10 Cont ID  
Sent By shill Date 2008-01-10 Time 10:34 Rev Time 0.00
Received By shill Date 2008-01-10 Time 10:34 Sent To  
Notes
2008-01-10 10:39:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.ONLY ONE PAGE OF A NOA WAS PROVIDED.WHEN
 SUBMITTING EVALUATION REPORTS, PLEASE PROVIDE THE
 ENTIRE REPORT.
  
 2.APPLICATION OF THE SECONDARY WATER BARRIER IS NOT
 CLEAR.ARE YOU INSTALLINGTHE UNDERLAYMENT OVER 30#
 OVER THE ENTIRE DECK?WHAT WILL SERVE AS THE SECONDARY
 WATER BARRIER FOR THE FLAT DECK?AN APPROVED CAP SHEET
 IN ADDITION TO THE MINIMUM MODIFIED SYSTEM CAN BE
 INCORPORATED INTO THE SYSTEM TO COMPLY WITH SECONDARY
 WATER BARRIER REQUIREMENTS.IF YOU NEED ASSISTANCE,
 PLEASE FEEL FREE TO CONTACT ME.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-12-20 Cont ID  
Sent By shill Date 2007-12-20 Time 11:14 Rev Time 0.00
Received By shill Date 2007-12-20 Time 11:14 Sent To  
Notes
2007-12-20 11:23:09****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
 FROM PREVIOUS LIST:
  
 1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER BARRIER
 REQUIRED FS553.844(5)(A). PROVIDE INFORMATION
 (PRODUCT APPROVAL OR SPECIFICATIONS) TO SHOW HOW YOU
 WILL COMPLY WITH THIS REQUIREMENT.INFORMATION IS
 AVAILABLE AT WWW.BOAF.NET, HURRICANE MITIGATION.
  
 CONTRACTOR PROVIDED A LETTER STATING THAT THIS
 STRUCTURE HAS A VALUE OF LESS THAN $300,000 ALONG IWTH
 THE DOCUMENT "HURRICANE MITIGATION RETROFITS FOR
 EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL
 STRUCTURES".PLEASE SEE THIS DOCUMENT, 101.1(B).
  
 WHEN A ROOF ON AN EXISTING SITE-BUILT, SIGNLE FAMILY
 RESIDENTIAL STRUCTURE IS REPLACED: (B) A SECONDARY
 WATER BARRIER SHALL BE PROVIDED AS REQUIRED BY SECTION
 201.2.
  
 THE $300,000 VALUE APPLIES TO THE NEXT SECTION, ROOF TO
 WALL CONNECTIONS.THE SECONDARY WATER BARRIER IS
 REQUIRED FOR ALL SITE BUILT SINGLE FAMILY RESIDENTIAL
 STRUCTURE REROOFS UNLESS CONSTRUCTED UNDER THE FLORIDA
 BUILDING CODE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-12-18 Cont ID  
Sent By shill Date 2007-12-18 Time 12:40 Rev Time 0.00
Received By shill Date 2007-12-18 Time 12:40 Sent To  
Notes
2007-12-18 12:41:36****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER BARRIER
 REQUIRED FS553.844(5)(A). PROVIDE INFORMATION
 (PRODUCT APPROVAL OR SPECIFICATIONS) TO SHOW HOW YOU
 WILL COMPLY WITH THIS REQUIREMENT.INFORMATION IS
 AVAILABLE AT WWW.BOAF.NET, HURRICANE MITIGATION.
  
 2.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED
 IN ADDITION TO THE EVALUATION REPORT SUBMITTED,
 FAC9B72.WWW.FLORIDABUILDING.ORGTHE FLORIDA STATE
 PRODUCT APPROVAL PROVIDED IS FOR BUR, NOA IS FOR
 MODIFIED.
  