Plan Review Stops For Permit 07120426 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
N |
Date |
2009-03-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-03-17 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-03-17 |
Time |
11:35 |
Sent To |
|
|
Notes |
2009-03-17 11:36:32 | NO STRUCTURAL OR ARCHITECTURAL PLANS WERE SUBMITTED. | | REVISIONS ARE FOR ELECTRICAL, PLUMBING AND MECHANICAL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2008-08-25 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-08-25 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-08-25 |
Time |
17:40 |
Sent To |
PC |
|
Notes |
2008-08-25 17:41:28 | | | | | REVISION CHANGE OF PRODUCT APPROVALS FOR CASEMENT | | WINDOWS AND FRENCH DOORS TO IMPACT RATED, SAME | | MANUFACTURER |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2008-08-12 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-08-12 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-08-12 |
Time |
15:25 |
Sent To |
PC |
|
Notes |
2008-08-12 15:26:22 | | | | | PASSED | | | | 1)REVISED SHEETS A-1 A-2 A-5 AND D-1 OK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-04-14 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-04-14 |
Time |
17:55 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-04-14 |
Time |
17:55 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-04-09 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-04-09 |
Time |
17:09 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-04-09 |
Time |
17:09 |
Sent To |
PC |
|
Notes |
2008-04-09 17:22:13 | | | | | DENIED | | | | THE FOLLOWING COMMENT IS OUTSTANDING FROM THE 1ST THRU | | 4TH REVIEW | | | | 1) BEFORE A PERMIT TO CONSTRUCT, MAY | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | SETS OF PLANS MUST BE STAMPED BY THAT | | OFFICE AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION | | | | **********PLEASE HAVE IMPACT FEE STAMP ON DRAWINGS AND | | PAID FEE RECEIPT INCLUDED WITH PERMIT APPLICATION | | BEFORE PERMIT CAN BE ISSUED, UPON COMPLETION OF THESE | | ITEMS PRESENT PAKAGE TO LUIS MARTINEZ FOR FINAL | | APPROVAL AND PERMIT PRINTING************ | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-03-25 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-03-25 |
Time |
18:37 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-03-25 |
Time |
18:37 |
Sent To |
PC |
|
Notes |
2008-03-25 18:41:17 | | | | | DENIED | | | | THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM THE 1ST | | AND 2ND REVIEWS, ALL ARCHITECTURAL REVIEW COMMENT HAVE | | BEEN ADDRESSED | | | | | | 1)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SETS OF PLANS MUST BE STAMPED BY THAT OFFICE, | | AND A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION. | | | | 2)NOTE: FEES ARE DUE IN THE AMOUNT OF $505.97 FOR | | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS | | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW | | ******$10.00 WAS ADDED TO FEES FOR HISTORIC | | REVIEW******* | | | | NOTE: ENERGY CALC'S REQUIRE CORRECTIONS, PLEASE SEE | | MECHANICAL REVIEW | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-03-08 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-03-08 |
Time |
07:47 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-03-08 |
Time |
07:47 |
Sent To |
PC |
|
Notes |
2008-03-08 09:07:35 | | | | | | | DENIED | | | | THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM THE 1ST | | REVIEW | | | | | | 1)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SETS OF PLANS MUST BE STAMPED BY THAT OFFICE, | | AND A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION. | | | | 2)NOTE: FEES ARE DUE IN THE AMOUNT OF $505.97 FOR | | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS | | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW | | ******$10.00 WAS ADDED TO FEES FOR HISTORIC | | REVIEW******* | | | | 4)SUBMIT TWO COPIES OF ENERGY CALC'S PLEASE NOTE | | MECHANICAL REVIEWERS COMMENT | | | | NEW COMMENTS | | | | 1)PROVIDE THE SYSTEM THAT WILL BE USED FROM THE | | MODIFIED BITUMEN ROOFING PRODUCT APPROVAL | | | | 2)HISTORIC APPROVAL STAMP IS REQUIRED ON THE | | DUPLICATE PERMIT APPLICATION FORM | | | | 3)SHUTTER OPENING #5 IN THE SHUTTER SCHEDULE SHOULD | | HAVE A DESIGN PRESSURE OF +49/-66 PSF PERTHE | | COMPONENT AND CLADDING SCHEDULE ON SHEET S-4 | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-01-09 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-01-09 |
Time |
18:07 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-01-09 |
Time |
18:07 |
Sent To |
|
|
Notes |
2008-01-09 18:32:37 | | | | | DENIED | | | | 1)BEFORE A PERMIT TO CONSTRUCT, MAY | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | SETS OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION. | | | | 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | PER 108.3 FBC* | | | | 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON | | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER | | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE | | ADDED TO THE PERMIT APPLICATION FEES | | | | NOTE: FEES ARE DUE IN THE AMOUNT OF $495.97 FOR | | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS | | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW | | | | 4)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2 | | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER | | AND OWNER/AGENT PRIOR | | TO SUBMITTAL. *****PROVIDE SEPARATE CALC'S FOR REMODEL | | AND NEW BUILDING ALSO CHECK CEILING AND WALL TYPES AND | | THEIR VALUES***** | | | | 5)PROVIDE 2 COPIES OF A RECENT SURVEY SHOWING THE | | PROPOSED BUILDING/ADDITION WITH ALL SIDE AND REAR | | SETBACKS | | | | 6)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE | | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. | | ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG | | | | 7)THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | RULE 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | 8)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | STATE PRODUCT APPROVAL COVER | | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON | | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT | | SUBMITTED APPLICATIONS WILL BE DENIED | | ****NO PRODUCT APPROVALS WERE SUBMITTED FOR IMPACT | | PROTECTION, FIXED WINDOWS (LIVINGROOM AND TRANSOM ABOVE | | FRENCH DOORS), MULLION ABOVE DOOR AND FLAT ROOF | | MEMBRANE ON GUEST HOUSE PORCH**** | | | | 9)PROVIDE ROOF VENTILATION ON DRAWINGS THAT COMPLIES | | WITH R806.1 & 806.2 FBC RES. | | | | 10)PROVIDE ATTIC ACCESS ON DRAWINGS TO ALL AREAS AS | | REQUIRED PER R807.1 FBC RES. | | | | 11)PROVIDESAFETY GLAZING PER R308.4 FBC RES. FOR | | HAZARDOUS LOCATIONS | | | | 12)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER | | R313.1.1 FBC RES. | | | | 13)IF SHUTTERS ARE TO BE USE AS MEANS OF IMPACT | | PROTECTION,INSTALLATIONS REQUIRE A KEY PLAN (WITH | | EGRESS SHOWN), SHUTTER SCHEDULE AND THE PRODUCT | | APPROVALS. APPROVAL DRAWINGS CAN BE MARKED FOR MOUNTING | | METHOD AND CONNECTION TYPE AND THE SCHEDULE FILLED OUT | | WITH ALL PERTINENT INFORMATION SPECIFIC TO THE SITE | | (TYPE OF CONSTRUCTION, MOUNTING CONNECTION METHOD, | | ANCHOR TYPE, SHUTTER SPAN (VERTICAL OR HORIZONTAL), | | ETC.) PLEASE SEE THE ATTACHED MEMO AND SCHEDULE. | | | | 14)AN ENGINEER PRACTICING THROUGH A DULYAUTHORIZED | | ENGINEERING BUSINESS SHALL INDICATE THEIR NAME AND | | LICENSE #, AS WELL AS THE NAME,ADDRESS AND CERTIFICATE | | OF AUTHORIZATION #ON EACH SHEET PER | | 61G15-23.002 (2) FAC *****PLEASE NOTE THAT MEP ENGINEER | | NAME AND LICENSE # ARE NOT INDICATED ON THE TITLE | | BLOCK***** | | | | 15)WINDOW UNIT MARK "U" IS NOT ON THE WINDOW | | SCHEDULE | | | | 16)CASEMENT WINDOW MARK "E" DOES NOT MEET THE DESIGN | | PRESSURES REQUIRED | | | | 17)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | *****PLEASE REMOVE ALL OLD PAGES AND RESUBMIT 2 | | COMPLETE SETS OF NEW DRAWINGS WITH REVISIONS AND | | INCLUDE 1 COPY OF THE OLD PAGES ONLY FOR | | REFERENCE.***** | | | | ******ADDITIONAL PERMITS WILL BE REQUIRED FOR PLUMBING, | | ELECTRICAL, MECHANICAL AND ROOFING****** | | | | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 | | AMENDMENTS | | FBC* = WEST PALM BEACH ADMINISTRATIVE | | AMENDMENTS TO FBC | | FAC = FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | FBC RES. = FLORIDA BUILDING CODE | | RESIDENTIAL 2004 W/2006 AMENDMENTS | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2009-03-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-03-24 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-03-24 |
Time |
18:52 |
Sent To |
PC |
|
Notes |
2009-03-24 18:55:22 | SUCCESSOR ARCHITECT TO PREVIOUS ENGINEER OF RECORD. | | | | REDLINED PLANS TO VIF THE OCP FOR BOTH AHU'S AND AFCI | | PROTECTION PER 210.12 OF THE 2005 NEC |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2009-03-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-03-05 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-03-05 |
Time |
08:49 |
Sent To |
M |
|
Notes |
2009-03-05 08:49:46 | ** DENIED REVIEW ** | | | | 1) NOTE: PLANS ON RECORD ARE UNDER THE DESIGN OF AGILE | | ENGINEERING INC. SIGNED, DATED AND SEALED BY MR. JOHN | | SYLVIA PE. PLEASE SEE FAC 61G15-23, FS 471.025 | | PLANS MUST BE REVISED BY THE DESIGNER OF RECORD OR | | PLEASE PROVIDE DOCUMENTATION AS REQUIRED BY THE FLORIDA | | ADMINISTRATIVE CODE FOR TAKING OVER THE RESPONSIBILITY | | OF ANOTHER DESIGN PROFESSIONALS WORK. | | A LETTER FROM THE ORIGINAL ENGINEERING RELEASING | | HIMSELF WOULD ALSO BE AN OPTION. | | | | 2) NOTE: THERE ARE SEVERAL ITEMS WHICH WERE ON PREVIOUS | | PLANS WHICH ARE NOW MISSING. | | DISCONNECTS, WATER HEATER, PANELS ETC. | | FOR EXAMPLE: GUEST HOUSE WATER HEATER, GUEST HOUSE | | ELECTRICAL PANEL, MAIN HOUSE DISCONNECT, MISSING | | REQUIRED GFI IN BATH AT GUEST HOUSE ETC. | | | | PLEASE GO THROUGH ORIGINAL PLANS. ITEMS MAY BE DELETED | | WHICH ARE NOT REQUIRED BY NFPA-70 ( NEC) HOWEVER BOTH | | MAIN HOUSE AND GUEST HOUSE MUST SHOW THE MINIMUM | | REQUIRED BY CODE. | | PLEASE SEE | | 4220.13,240.24,110.26,215.5,225.31-225.39,210.8A2, | | 210.52D ETC | | | | 3) NOTE: PLEASE PROVIDE REVISED PANEL SCHEDULE, RISER | | AND LOAD CALCULATIONS. 408.4,215.5,250,220 | | | | 4) NOTE: KITCHEN IN MAIN HOUSE NOW SHOWS RECEPTACLES | | WHICH WERE NOT ON ORIGINAL PERMITTED PLANS. ALL | | RECEPTACLES SERVICE KITCHEN COUNTER SPACE SHALL BE GFI/ | | GFI PROTECTED. 210.8A6 | | | | 5) NOTE: PLANS MISSING WALL RECEPTACLE REQUIRED PER | | 210.52 WHICH WAS ON ORIGINAL PLANS. SEE KITCHEN WALL IN | | GUEST HOUSE. | | | | 6) NOTE: PLANS INDICATE A NEW MINI LIFT STATION HOWEVER | | THERE IS NO ELECTRICAL SHOWN ON THE E-SHEETS FOR ANY | | SUCH ITEM. NO ELECTRICAL DETAIL, NO DISCONNECT, NO | | REVISE PANEL, NO INCREASED LOAD. | | NEC 2005 220,215,430,ETC | | FBC 106.1.1, 106.1.2 FOR ADDITIONAL INFORMATION AND | | CLARITY. | | | | | | *** THESE ITEMS ABOVE ARE SOME EXAMPLES THAT HAVE | | CHANGED THE PLANS SUBSTANTIALLY WHICH NEED TO SHOW CODE | | COMPLIANCE. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-03-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-03-21 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-03-21 |
Time |
10:38 |
Sent To |
M |
|
Notes |
2008-03-21 10:39:02 | ELECTRICAL PLANS STAMPED, SENT ON TO MECH. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2008-03-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-03-03 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-03-03 |
Time |
16:01 |
Sent To |
B |
|
Notes |
2008-03-03 16:02:33 | ** DENIED 2ND REVIEW ** | | | | ** PLEASE SEE SOME COMMENTS FROM THE PREVIOUS REVIEW | | ARE STILL IN NEED OF ADDRESSING. | | ** PLEASE ALSO SEE THAT MANY COMMENTS ARE NEW AS THESE | | THINGS ARE JUST NOW BEING SHOWN. | | PLEASE ALSO SEE THE RISER HAS NOW BEEN COMPLETELY | | REVISED. SOME NEW COMMENTS HAVE NOW BEEN CREATED. MANY | | ITEMS WHICH WERE CODE COMPLIANT ON PREVIOUS REVIEW HAVE | | NOW COMPLETELY CHANGED AND ARE NOW NO LONGER CODE | | COMPLIANT. | | | | 1) NOTE: PLEASE SEE THE RISER HAS BEEN REVISED REMOVING | | A MAIN FOR GROUPING OF MAINS AS REQUIRED PER 230.72. ON | | THE PREVIOUS REVIEW A COMMENT WAS MADE THAT A MAIN | | DISCONNECT WAS MISSING AT THE MAIN HOUSE AS REQUIRED | | PER 225.31-225.39. THIS MAIN WHICH WAS ON PREVIOUS | | RISER GROUPED, HAS NOW BEEN MOVED. THE CODE REQUIRES | | MAINS FOR SERVICE TO BE GROUPED PER 230.72 AND A MAIN | | AT THE DETACHED STRUCTURE PER 225.31-225.39. PLEASE | | ADJUST RISER. | | | | 2) NOTE: PLEASE ALSO CORRELATE RISER AND PLANS. THE | | RISER SHOWS THE MAIN AT THE HOUSE AS 200AMPS AND THE | | PLANS CLEARLY SHOW A MAIN DISCONNECT RATED AT 125AMPS? | | PLEASE SEE THE PREVIOUS PLANS INDICATE 125AMPS FOR | | PANEL AND MAIN AND THESE NOW INDICATE 200AMP FOR | | BOTH?? | | 230, 225, 240.4, 310.16 ETC | | FBC 106.1.2 FOR COORDINATION. IT IS UNCLEAR AT THIS | | TIME WHAT MAINS AND PANELS ARE REALLY BEING DESIGNED. | | PLEASE ALSO SEE NEXT COMMENT AS SERVICE SIZE HAS NOW | | BEEN INCREASED. | | | | 3) NOTE: PLEASE SEE PREVIOUS PLANS WHICH SHOWED ONE | | 125AMP MAIN AND ONE 75AMP MAIN WHICH WAS IN LINE WITH | | THE 200AMP RATED CONDUCTORS AND SERVICE. HOWEVER PLEASE | | NOW SEE AS THE SERVICE NOW SHOWS A NEW 200AMP MAIN AND | | A NEW 100AMP MAIN THE RATING OF THE SERVICE NEEDS TO | | COORDINATE AND BE SIZED FOR THE OVER CURRENT PROTECTION | | AND CONDUCTORS. THIS IS NOW SHOWN AS A 300AMP SERVICE. | | RISER SHOWS 3/0 CONDUCTORS TO THE 100AMP MAIN AND 3/0 | | CONDUCTORS TO THE 100AMP SUB PANEL? | | PLEASESEE 240.4, 310.16 ETC | | AS THERE ARE SEVERAL ITEMS WHICH WILL BE ADJUSTED, A | | FULL REVIEW OF ALL ITEMS CAN NOT BE DONE AT THIS TIME. | | FBC 106.3.5.4 | | **PLEASE ALSO SEE THE METER WOULD ALSO NOW NEED TO BE | | SHOWN AS 300AMPS. | | | | 4) NOTE: PLEASE SEE 240.4, 250.66, 310.15B6 AND 310.16. | | IF THE MINIMUM SERVICE IS NOW GOING TO BE 300AMPS, | | PLEASE ADJUST SERVICE ENTRANCE CONDUCTORS AND THE | | GROUNDING ELECTRODE CONDUCTOR AT THE MAIN SERVICE. IF | | SERVICE IS GOING TO BE 300AMPS, THEN BASED ON MINIMUM | | SERVICE ENTRANCE CONDUCTORS PER 310.15B6 AND THE | | SIZING ON TABLE 250.66 REQUIRES THE GEC AT #2 AWG AT | | MAIN SERVICE LOCATION. | | | | 5) NOTE: PREVIOUS REVIEW NOTE REQUESTED TO SHOW THE | | GROUNDING ELECTRODE SYSTEM AT BOTH GUEST HOUSE AND | | DETACHED STRUCTURE (MAIN HOUSE). THE RESPONSE MENTIONS | | THIS IS NOW SHOWN HOWEVER ONLY SHOWS A GROUNDOF SOME | | TYPE. THIS WILL REQUIRE FOOTER STEEL, (METAL) CWP AND | | BONDING OF ANY GAS PIPING PER 250.50, 250.56, 250.52, | | AND 250.104. | | | | 6) NOTE: PLEASE SEE PREVIOUS NOTE WITH RESPECT TO THE | | LIGHT FIXTURES OUTSIDE GUEST HOUSE AND MAIN HOUSE WHICH | | DID NOT MEET 680.22B1 | | THE PLANS HAVE NOW BEEN REVISED TO SHOW THESE FIXTURES | | AT 12FT AFF YET THIS WOULD PLACE THE FIXTURES ABOVE THE | | ROOF LINE BASED ON THE ELEVATIONS ON THE ARCHITECTURAL | | PLANS.??? | | PLEASE SEE THE LOCATIONS OF THE LIGHTING FIXTURES NEED | | TO BE REVISED. PLEASE ALSO SEE THAT BASED ON THE SCALE | | ON PLANS THE GFI RECEPTACLES ON BOTH THE MAIN HOUSE AND | | GUEST ARE SHOWN AT 5FT. THESE MUST BE MORE THAN 5FT | | FROM WATERS EDGE. THESE COULD BE REDLINED TO VIF | | HOWEVER BASED ON PLANS AT THIS TIME THIS NEEDS TO BE | | VERIFIED AS LIGHT FIXTURES NEED TO BE RELOCATED. | | | | 7) NOTE: PLEASE SEE AS PANEL SCHEDULES ARE NOW BEING | | SUBMITTED. PLEASE SEE THAT THESE ARE REQUIRED TO BE | | DETAILED FOR ALL ROOMS AND AREAS IN WHICH THEY FEED PER | | 408.4, 240.4, 310.16. | | IE; BEDRM #2 LTS, KITCHEN LTS. ETC | | FBC 106.1.2, 106.3.5.4, 106.5 | | | | 8) NOTE: PLEASE SEE MISSING RECEPTACLE ALONG KITCHEN | | WALL IN GUEST HOUSE AND NEW MASTER BEDROOM WALL PER | | 210.52. | | ONE WAS GIVEN ON PREVIOUS REVIEW AND CODE FOR 210.52. | | THE PREVIOUS EXAMPLE FOR MISSING WAS DONE BUT NOT ALL | | LOCATIONS FOR NEW WALLS 2FT OR MORE WHERE REQUIRED PER | | 210.52. | | | | 9) NOTE: PLEASE GO OVER LOAD CALCULATIONS AS THE SQ FT | | FOR GUEST HOUSE ON MAIN SERVICE LOAD SUMMARY DOES NOT | | COORDINATE WITH THE SQ FT ON GUEST HOUSE PANEL | | CALCULAITONS. | | NEC 220 | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-12-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-12-24 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-12-24 |
Time |
13:06 |
Sent To |
P |
|
Notes |
2007-12-24 13:06:35 | ** DENIEDREVIEW ** | | | | *** IMPORTANT** | | AS SOME ITEMS WERE NOT SUBMITTED COMPLETE FOR REVIEW, | | THERE MAY BE NEW COMMENTS ON THE FOLLOWING REVIEW WHICH | | CAN NOT BE MADE AT THIS TIME. | | | | ** THE FOLLOWING COMMENTS ARE BASED ON PLANS SUBMITTED | | ONLY. | | | | 1) NOTE: PLEASE BE SURE THE ELECTRICAL PLANS CONTAIN | | THE FOLLOWING ADOPTED CODES BY THE STATE. | | 2005 NFPA-70 | | 2002 NFPA-72 | | | | 2) NOTE: PLEASE SEE THE TITLE BLOCK FOR THE ENGINEERING | | FIRM IS MISSING THE PRINTED NAME AND PRINTED LICENSE | | NUMBER OF THE ENGINEER AS REQUIRED BY THE FLORIDA | | ADMINISTRATIVE CODE 61G15-23.002 | | | | 3) NOTE: PLEASE SEE THE NEW SERVICE RISER AS SUBMITTED | | NEEDS SEVERAL ITEMS TO BE ADDRESSED: | | | | A) PLEASE SEE THE NEW MAIN DISCONNECT AND NEW PANEL FOR | | THE NEW GUEST HOUSE SHOWS 75AMP MAIN AND PANEL, HOWEVER | | THIS DOES NOT CORRELATE WITH THE STANDARD OVER CURRENT | | PROTECTION DEVICES OR EQUIPMENT AS STATED IN THE NEC | | 240.6. | | PLEASE ALSO SEE 110.3, 90.7 AND ADJUST. | | | | B) PLEASE INCLUDE THE SIZE (AMPERAGE) OF NEW METER. | | 90.7, 230.70, 230.71, 230.90 ETC | | | | C) PLEASE INCLUDE THE TAPPED CONDUCTORS FROM NEW | | SERVICE GUTTER TO NEW MAIN. 240.21, 240.4, 310.16 ETC | | | | D) PLEASE SEE MISSING REQUIRED DISCONNECTING MEANS AT | | THE MAIN HOUSE PER 225.31-225.39. | | | | E) PLEASE SEE MISSING GROUNDING ELECTRODE SYSTEM AT THE | | MAIN HOUSE PER 250.32, 250.50. | | | | F) PLEASE COMPLETE GROUNDING ELECTRODE AT THE SERVICE | | LOCATION. THE GROUNDING DETAIL ON E-2 NOTES GROUND RODS | | PER 250.83, AND 250.84 HOWEVER PLEASE SEE THE 2005 NEC, | | AS 250.83 DOES NOT EXIST AND 250.84 IS NOT FOR GROUND | | RODS. PLEASE ADJUST SYSTEM AND NOTES. | | | | 4) NOTE: PLEASE CLARIFY THE SMOKE DEVICES ON PLANS. | | PLEASE SEE THE SYMBOL AS SHOWN WHICH IS THE *S* IN THE | | BOX IS NOTED AS A DUCT DETECTOR ON SYMBOL LEGEND. | | PLEASE SEE R313 AND NFPA-72 11.5.1.1.1 AND 11.8.3 AS | | THESE SHOULD BE NOTED AS SA FOR SMOKE ALARMS. | | PLEASE SEE MISSING SA OUTSIDE BEDROOM AT THE GUEST | | HOUSE. | | PLEASE ADJUST NOTES AND PLANS. | | | | 5) NOTE: PLEASE SUBMIT PANEL SCHEDULES FOR BOTH THE NEW | | PANEL AT GUEST HOUSE AND THE NEW PANEL AT THE MAIN | | HOUSE. PLEASE SHOW ALL NEW MINIMUM CIRCUITS REQUIRED BY | | THE NEC ALONG WITH THE ADDITIONAL AND EXISTING | | CIRCUITS. PLEASE PROVIDE THE BRANCH CIRCUIT SIZE, OVER | | CURRENT PROTECTION RATING AND CONDUCTORS. | | PLEASE SEE SOME COMMENTS BELOW AS THE *LOAD SUMMARY* | | SUBMITTED CONTAIN ITEMS WHICH DO NOT MEET THE MINIMUM | | PER NEC. | | 408.4, 240.4, 310.16, ETC | | FBC 106.3.5.4 | | | | 6) NOTE: PLEASE SEE THE WATER HEATER AS SHOWN ON LOAD | | SUMMARY DOES NOT MEET 422.1AND422.13. PLEASE SEE THE | | LOAD IS SHOWN AT 6KW YET THE OVER CURRENT PROTECTION IS | | SHOWN AS A 20AMP BREAKER. | | ** PLEASE ALSO SEE THE PLAN WHICH SHOWS 60AMP FOR THE | | WATER HEATER? | | ** IS THERE ARE WATER HEATER AT THE MAIN HOUSE? | | | | 7) NOTE: PLEASE SEE THE MINIMUM LOAD WHICH THE CODE | | REQUIRES FOR THE DRYER SHALL BE 5KW. PLEASE SEE NEC | | 220.54. | | PLEASE ALSO SEE THE SIZE OF THE CIRCUIT SHALL BE BASED | | ON THE LOAD AND VOLTAGE SUPPLIED. (SHOWS 20AMPS BREAKER | | WHICH IS NOT RATED FOR 5KW AT 240V). PLEASE ADJUST | | | | 8) NOTE: PLEASE SUBMIT REVISED LOAD CALCULATIONS FOR | | EACH PANEL AND FOR SERVICE. PLEASE CORRECT AS PER NOTES | | ABOVE PER NEC 220. | | FBC 106.3.5.4 | | | | 9) NOTE: PLEASE SEE DISCONNECT(S) SHOWN FOR CONDENSING | | UNITS DO NOT COMPLIANCE FOR 110.26. | | PLEASE RE-LOCATE | | | | 10) NOTE: PLEASE VERIFY THE GFI SHOWN ON PLANS AT THE | | MAIN HOUSE MEETING 210.63/210.8A FOR THE OUTSIDE | | CONDENSING UNIT. PLAN SHOWS THIS FOR A PUMP. IF THIS IS | | FOR THE PUMP, THE SERVICE RECEPTACLE AS REQUIRED PER | | SECTIONS GIVEN WOULD BE IN ADDITION TO THE DEDICATE GFI | | SUPPLIED FOR THE PUMP. | | | | 11) NOTE: PLEASE SEE NEC 680.22 AS THE LIGHTING | | FIXTURES SHOWN ON MAIN HOUSE AND GUEST HOUSE DO NOT | | MEET THE MINIMUM DISTANCES PER SECTION GIVEN. | | | | 12) NOTE: PLEASE SEE THE EGRESS LIGHTING CONTROL AT THE | | GUEST HOUSE MUST BE INSIDE THE ROOM (OFFICE) AS SHOWN | | PER 210.70. | | | | 13) NOTE: PLEASE SEE NEC2005 210.12 WHICH REQUIRED | | AFCI PROTECTION FOR ALL OUTLETS IN BEDROOM/SLEEPING | | ROOMS. THIS INCLUDES ALL RECEPTACLES, LIGHTS, FANS, | | SMOKE ALARMS ETC. | | PLEASE SEE THE PLANS ONLY SHOW PROTECTION FOR | | RECEPTACLES WHICH WAS IN THE 2002 NEC. | | PLEASE LIST ON THE BRANCH CIRCUITS TO BE PROVIDED ON | | THE NEW PANEL SCHEDULES TO BE SUBMITTED. | | | | 14) NOTE: PLEASE SUBMIT AND SHOW THE REQUIRED AIC | | RATING FOR SERVICE MAINS AND EQUIPMENT PER 110.9. | | | | 15) NOTE: PLEASE PROVIDE NOTE FOR TYPE OF RECESSED | | LIGHTING FIXTURES PER 13-606.1.ABC.1.2.4 | | | | 16) NOTE: PLEASE SEE THERE ARE SEVERAL GFI RECEPTACLES | | ON PLAN WHICH SHOWS THE SYMBOL FOR HALF SWITCHED | | DEVICE. GFI RECEPTACLES CAN NOT BE HALF SWITCHED. | | 110.3 | | | | 17) NOTE: PLEASE SEE MISSING RECEPTACLE IN OFFICE ALONG | | 2FT OF WALL PER 210.52 | | | | 18) NOTE: PLEASE SEE REQUIRED DEDICATED CIRCUIT(S) FOR | | BATH ROOMS TO BE CONFIRMED ON NEW PANEL SCHEDULES. | | PLEASE SEE 210.11C3 AS THESE ARE REQUIRED TO BE 20AMP | | AND #12. | | | | ** AS NOTED ABOVE, PLEASE KNOW AS THERE ARE MANY ITEMS | | NOT SUBMITTED OR SHOWN, A COMPLETER REVIEW FOR CODE | | COMPLIANCE CAN NOT BE DONE AT THIS TIME.** IF THERE ARE | | QUESTIONS, PLEASE CALL. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
15 |
Status |
N |
Date |
2010-09-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-09-23 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-09-23 |
Time |
11:17 |
Sent To |
Z |
|
Notes |
2010-09-23 11:18:17 | LANDSCAPE PLANS SENT TO ZONING FOR R. KUSSNER REVIEW. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2009-03-24 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-03-24 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-03-24 |
Time |
13:27 |
Sent To |
E |
|
Notes |
2009-03-24 13:27:37 | SENT TO DVP DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2009-02-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-26 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-26 |
Time |
12:23 |
Sent To |
Z |
|
Notes |
2009-02-26 12:23:30 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2009-01-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-01-07 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-01-07 |
Time |
10:05 |
Sent To |
P |
|
Notes |
2009-01-07 10:06:06 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2008-10-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-10-03 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-10-03 |
Time |
16:10 |
Sent To |
M |
|
Notes |
2008-10-03 16:11:12 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2008-09-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-25 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-25 |
Time |
16:44 |
Sent To |
M |
|
Notes |
2008-09-25 16:44:38 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2008-09-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-22 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-22 |
Time |
16:34 |
Sent To |
M |
|
Notes |
2008-09-22 16:35:03 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2008-08-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-25 |
Time |
11:16 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2008-08-25 |
Time |
11:16 |
Sent To |
B |
|
Notes |
2008-08-25 11:17:47 | TO BUILDINGA.M. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2008-08-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-11 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-11 |
Time |
10:54 |
Sent To |
B |
|
Notes |
2008-08-11 10:55:01 | TO "AMORSE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-08-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-11 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-11 |
Time |
10:11 |
Sent To |
B |
|
Notes |
2008-08-11 10:14:37 | TO "MJACOBS" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-04-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-14 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-14 |
Time |
15:56 |
Sent To |
B |
|
Notes |
2008-04-14 15:56:51 | TO "AMORSE" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-04-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-02 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-02 |
Time |
09:26 |
Sent To |
M |
|
Notes |
2008-04-02 09:26:57 | TO "M" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-03-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-21 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-21 |
Time |
09:52 |
Sent To |
E |
|
Notes |
2008-03-21 09:52:33 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-02-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-19 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-19 |
Time |
10:06 |
Sent To |
Z |
|
Notes |
2008-02-19 10:06:36 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2008-01-09 |
Time |
|
Rev Time |
0.00 |
Received By |
mmiller |
Date |
2007-12-20 |
Time |
17:22 |
Sent To |
|
|
Notes |
2007-12-20 17:22:16 | SENT TO SINGLE FAMILY RACK MMILLER |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
2 |
Status |
P |
Date |
2010-09-27 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2010-09-27 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2010-09-27 |
Time |
10:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
F |
Date |
2009-10-22 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2009-10-22 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2009-10-22 |
Time |
16:30 |
Sent To |
|
|
Notes |
2009-10-22 16:42:09 | ***LANDSCAPE REVIEW FAILED*** | | | | PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN | | FORMAT. | | | | 1. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE | | EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING | | AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE | | XERISCAPE DESIGN OPTIONS. | | | | 2. PURSUANT TO SECTION 94-448 (D) (2), ALL RELEVANT | | ITEMS FOUND IN THIS SECTION SHALL BE PART OF THE | | LANDSCAPE PLAN. | | | | 3. PROVIDE THE SPACING FOR ALL HEDGES AND GROUND COVER. | | | | 4. THE 9 FOOT HEDGE ADJACENT TO GREENWOOD LANE CREATES | | A VISIBILITY CONCERN WHEN SOMEONE IS EXITING THE | | DRIVEWAY. THE HEDGE SHALL BE REDUCED IN HEIGHT TO ALLOW | | VISIBILITY ADJACENT TO THE DRIVEWAY. | | | | 5. PROVIDE A COST ESTIMATE THAT INCLUDES THE TOTAL COST | | OF ALL LANDSCAPE MATERIALS AND LABOR. IT SHALL BE | | BROKEN DOWN INTO UNIT COST. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | KUSSNER @ (561) 822-1462. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
9 |
Status |
P |
Date |
2009-03-12 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-03-12 |
Time |
20:20 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-03-12 |
Time |
20:20 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
8 |
Status |
P |
Date |
2008-10-06 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-10-06 |
Time |
08:40 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-10-06 |
Time |
08:40 |
Sent To |
|
|
Notes |
2008-10-06 08:41:25 | REVISION TO MECH. PLANS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
F |
Date |
2008-09-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-09-26 |
Time |
08:48 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-09-26 |
Time |
08:48 |
Sent To |
|
|
Notes |
2008-09-26 08:49:46 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | REVISION TO MECHANICAL PLAN M-1 | | *** DENIED *** | | | | *AS NOTED IN LAST REVIEW 9/23/08* | | | | 1) THE LETTER SUBMITTED TO TERMINATE AGILE ENGINEERING | | INC. CAN NOT BE EXCEPTED AS THE MECHANICAL CONTRACTOR | | WAS NOT THE PERSON TO HIRER THEIR FIRM, SEE F.A.C. | | 61G15-27. THE PROPERTY OWNER OR THE GENERAL CONTRACTOR | | (PERSON WHO HIRED THE FIRM) NEEDS TO PREPARE AND SUBMIT | | THE LETTER TO REMOVE THE ENGINEER. PLEASE HAVE THE JOB | | ADDRESS AND PERMIT NUMBER ON THE LETTER WHEN | | SUBMITTING. | | | | 2) TITLE BLOCK OF REVISED PLAN HAS THE WRONG LICENSE | | NUMBER FOR SCOTT WEBSTER. | | | | 3) BE ADVISED "TROPICAL COOLING, INC." IS NOT A | | LICENSED COMPANY, PLEASE CORRECT. | | | | 4) IF THIS PLAN IS TO BE SUBMITTED AFTER THE ABOVE | | CORRECTIONS ARE MADE. THE RETURN AIR TRANSFER DUCT | | (FLEX) FROM THE BEDROOM TO THE OFFICE NEEDS TO BE SIZED | | ON THE PLAN, PER 2004 FBC/R M1602.4. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
F |
Date |
2008-09-23 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-09-23 |
Time |
13:30 |
Rev Time |
0.10 |
Received By |
tgordon |
Date |
2008-09-23 |
Time |
13:30 |
Sent To |
|
|
Notes |
2008-09-23 14:07:23 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | REVISION TO MECHANICAL PLAN M-1 | | *** DENIED *** | | | | 1) THE LETTER SUBMITTED TO TERMINATE AGILE ENGINEERING | | INC. CAN NOT BE EXCEPTED AS THE MECHANICAL CONTRACTOR | | WAS NOT THE PERSON TO HIRER THEIR FIRM, SEE F.A.C. | | 61G15-27. THE PROPERTY OWNER OR THE GENERAL CONTRACTOR | | (PERSON WHO HIRED THE FIRM) NEEDS TO PREPARE AND SUBMIT | | THE LETTER TO REMOVE THE ENGINEER. PLEASE HAVE THE JOB | | ADDRESS AND PERMIT NUMBER ON THE LETTER WHEN | | SUBMITTING. | | | | 2) TITLE BLOCK OF REVISED PLAN HAS THE WRONG LICENSE | | NUMBER FOR SCOTT WEBSTER. | | | | 3) BE ADVISED "TROPICAL COOLING, INC." IS NOT A | | LICENSED COMPANY, PLEASE CORRECT. | | | | 4) IF THIS PLAN IS TO BE SUBMITTED AFTER THE ABOVE | | CORRECTIONS ARE MADE. THE RETURN AIR TRANSFER DUCT | | (FLEX) FROM THE BEDROOM TO THE OFFICE NEEDS TO BE SIZED | | ON THE PLAN, PER 2004 FBC/R M1602.4. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2008-04-07 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-04-07 |
Time |
08:38 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2008-04-07 |
Time |
08:38 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2008-04-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-04-03 |
Time |
08:43 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2008-04-03 |
Time |
08:43 |
Sent To |
B |
|
Notes |
2008-04-03 08:48:07 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | | | ** ENERGY CALCULATIONS FOR GUEST HOUSE HAVE NOT BEEN | | REVISED SO COMMENTS FROM LAST REVIEW STILL NEED TO BE | | ADDRESSED. ** | | | | 1) ENERGY CALCULATIONS FOR GUEST HOUSE LINE 12A SHOWS A | | 34,200 BTU A/C SYSTEM BEING INSTALLED PLANS STATE A | | 17,300 BTU SYSTEM IS BEING INSTALLED, PLEASE CORRECT | | ENERGY CAL'S. | | | | 2) ENERGY CALCULATIONS FOR GUEST HOUSE SHOW UNDUCTED | | COOLING AND HEATING SYSTEM, PLANS SHOW A DUCTED SYSTEM, | | PLEASE CORRECT ENERGY CAL'S. | | | | 3) ENERGY CALCULATION FOR THE GUEST HOUSE ARE TAKING | | THE CROSS VENTILATION CREDIT ON LINE 15. PLEASE SUBMIT | | CALCULATIONS FOR THE 12% BUILDING OPENINGS TO FLOOR | | AREA, SEE 2004 FBC 13-607.1.A.3.1. | | | | 3A) ALSO ADD DETAIL FOR SCREEN DOORS TO BE INSTALLED AT | | DOOR OPENING IF THESE OPENINGS ARE INCLUDED IN THE | | ABOVE CALCULATIONS, PER 2004 FBC 13-607.1.A.3.1. | | | | 2004 FBC 13-607.1.A.3.1 CROSS VENTILATION CREDIT. | | HOUSES FOR WHICH CREDIT IS CLAIMED FOR CROSS | | VENTILATION IN ACCORDANCE WITH THE CRITERIA IN SECTION | | 13-607.2.A.3.3 SHALL HAVE PROVIDED OPERABLE APERTURE | | AREAS TOTALING A MINIMUM OF 12 PERCENT OF THE FLOOR | | AREA OF THE ROOM FOR ALL PRIMARY LIVING AREAS AND MAIN | | BEDROOMS. | | INSECT SCREENS SHALL BE PROVIDED FOR ALL WINDOWS AND | | DOORS TO BE CONSIDERED OPERABLE APERTURE AREA. ALL | | SCREENED ENTRY DOORS AND INTERIOR DOORS IN THE | | VENTILATED AREAS SHALL BE PROVIDED WITH EITHER (1) | | MECHANICALLY ATTACHED DOOR STOPS (OR SIMILAR DEVICES) | | TO HOLD THE DOOR IN AN OPEN POSITION OR (2) OPERABLE | | LOUVERS. | | THE TOTAL APERTURE AREA SHALL BE PROVIDED BY A MINIMUM | | OF TWO DISTINCT WINDOWS. EACH WINDOW SHALL PROVIDE NOT | | MORE THAN 70 PERCENT OF THE TOTAL APERTURE AREA. THE | | WINDOWS (OR SLIDING GLASS DOORS) SHALL BE PLACED IN | | ADJACENT OR OPPOSITE WALLS. THE WINDOWS MAY BE PLACED | | ON A SINGLE OUTSIDE WALL IF WING WALLS ARE USED. WHERE | | WING WALLS ARE INCLUDED IN THE BUILDING DESIGN FOR | | VENTILATION PURPOSES, THEY SHALL BE PLACED BETWEEN | | WINDOWS TO CREATE A HIGH-PRESSURE AND A LOW-PRESSURE | | ZONE ON EACH WINDOW. WING WALLS SHALL EXTEND FROM THE | | GROUND TO EVE HEIGHT, BE LOCATED ON THE WINDWARD SIDE | | OF THE BUILDING, AND EXTEND OUTWARD FROM THE BUILDING A | | DISTANCE AT LEAST EQUAL TO ONE-HALF THE WIDTH OF THE | | WINDOW. | | NOTE: THIS TECHNIQUE IS EFFECTIVE ONLY FOR AREAS WHICH | | EXPERIENCE SIGNIFICANT AND CONTINUOUS WINDS DURING THE | | COOLING MONTHS. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2008-03-21 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-03-21 |
Time |
11:48 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-03-21 |
Time |
11:48 |
Sent To |
B |
|
Notes |
2008-03-21 12:04:34 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) ENERGY CALCULATIONS FOR GUEST HOUSE LINE 12A SHOWS A | | 34,200 BTU A/C SYSTEM BEING INSTALLED PLANS STATE A | | 17,300 BTU SYSTEM IS BEING INSTALLED, PLEASE CORRECT | | ENERGY CAL'S. | | | | 2) ENERGY CALCULATIONS FOR GUEST HOUSE SHOW UNDUCTED | | COOLING AND HEATING SYSTEM, PLANS SHOW A DUCTED SYSTEM, | | PLEASE CORRECT ENERGY CAL'S. | | | | 3) ENERGY CALCULATION FOR THE MAIN HOUSE AND THE GUEST | | HOUSE ARE TAKING THE CROSS VENTILATION CREDIT ON LINE | | 15. PLEASE SUBMIT CALCULATIONS FOR THE 12% BUILDING | | OPENINGS TO FLOOR AREA, SEE 2004 FBC 13-607.1.A.3.1. | | | | 3A) ALSO ADD DETAIL FOR SCREEN DOORS TO BE INSTALLED AT | | DOOR OPENING IF THESE OPENINGS ARE INCLUDED IN THE | | ABOVE CALCULATIONS, PER 2004 FBC 13-607.1.A.3.1. | | | | 2004 FBC 13-607.1.A.3.1 CROSS VENTILATION CREDIT. | | HOUSES FOR WHICH CREDIT IS CLAIMED FOR CROSS | | VENTILATION IN ACCORDANCE WITH THE CRITERIA IN SECTION | | 13-607.2.A.3.3 SHALL HAVE PROVIDED OPERABLE APERTURE | | AREAS TOTALING A MINIMUM OF 12 PERCENT OF THE FLOOR | | AREA OF THE ROOM FOR ALL PRIMARY LIVING AREAS AND MAIN | | BEDROOMS. | | INSECT SCREENS SHALL BE PROVIDED FOR ALL WINDOWS AND | | DOORS TO BE CONSIDERED OPERABLE APERTURE AREA. ALL | | SCREENED ENTRY DOORS AND INTERIOR DOORS IN THE | | VENTILATED AREAS SHALL BE PROVIDED WITH EITHER (1) | | MECHANICALLY ATTACHED DOOR STOPS (OR SIMILAR DEVICES) | | TO HOLD THE DOOR IN AN OPEN POSITION OR (2) OPERABLE | | LOUVERS. | | THE TOTAL APERTURE AREA SHALL BE PROVIDED BY A MINIMUM | | OF TWO DISTINCT WINDOWS. EACH WINDOW SHALL PROVIDE NOT | | MORE THAN 70 PERCENT OF THE TOTAL APERTURE AREA. THE | | WINDOWS (OR SLIDING GLASS DOORS) SHALL BE PLACED IN | | ADJACENT OR OPPOSITE WALLS. THE WINDOWS MAY BE PLACED | | ON A SINGLE OUTSIDE WALL IF WING WALLS ARE USED. WHERE | | WING WALLS ARE INCLUDED IN THE BUILDING DESIGN FOR | | VENTILATION PURPOSES, THEY SHALL BE PLACED BETWEEN | | WINDOWS TO CREATE A HIGH-PRESSURE AND A LOW-PRESSURE | | ZONE ON EACH WINDOW. WING WALLS SHALL EXTEND FROM THE | | GROUND TO EVE HEIGHT, BE LOCATED ON THE WINDWARD SIDE | | OF THE BUILDING, AND EXTEND OUTWARD FROM THE BUILDING A | | DISTANCE AT LEAST EQUAL TO ONE-HALF THE WIDTH OF THE | | WINDOW. | | NOTE: THIS TECHNIQUE IS EFFECTIVE ONLY FOR AREAS WHICH | | EXPERIENCE SIGNIFICANT AND CONTINUOUS WINDS DURING THE | | COOLING MONTHS. | | | | 4) PLEASE SUBMIT TWO COPIES OF THE ENERGY CALCULATIONS | | FOR THE MAIN AND GUEST HOUSE, AS ONLY ONE COPY WAS | | SUBMITTED. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2008-02-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-02-25 |
Time |
08:48 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-02-25 |
Time |
08:48 |
Sent To |
P |
|
Notes |
2008-02-25 08:58:25 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) AS NOTED IN LAST REVIEW 12-24-07 NOTE #1 ENERGY | | CALCULATIONS FOR MAIN HOUSE AND GUEST HOUSE LINE 13A | | ARE CALLING FOR HEAT PUMP UNITS, MECHANICAL PLAN PAGE | | M-2 IS SHOWING STRAIGHT COOLING UNITS, THE TWO MUST | | COINCIDE, SEE 2004 FBC 13-600.3.ABC.2. PLEASE CORRECT. | | | | 2) SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING FOUR | | TIMES THE FEE. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-12-24 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-12-24 |
Time |
08:20 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-12-24 |
Time |
08:20 |
Sent To |
E |
|
Notes |
2007-12-24 08:30:08 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) ENERGY CALCULATIONS LINE 13A AND B ARE CALLING FOR | | HEAT PUMP UNITS, MECHANICAL PLAN PAGE M-2 IS SHOWING | | STRAIGHT COOLING UNITS, THE TWO MUST COINCIDE, PLEASE | | CORRECT. | | | | 2) THE TWO BUILDING CAN NOT BE ON THE SAME ENERGY | | CALCULATIONS, THEY MUST EACH HAVE THERE OWN ENERGY | | CALCULATIONS DONE, SEE 2004 FBC 13-101.2.5.1. PLEASE | | CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2009-03-16 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2009-03-16 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2009-03-16 |
Time |
11:15 |
Sent To |
B |
|
Notes |
2009-03-16 11:38:20 | REVISION OK | | LETTER REMOVING ENGINEER ON FILE. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2009-01-30 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2009-01-30 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2009-01-29 |
Time |
09:44 |
Sent To |
|
|
Notes |
2009-01-30 08:47:23 | PLUMBING PLAN REVIEW: | | DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | GAS/PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 106.1 SUBMITTAL DOCUMENTS. IF THE DESIGN | | PROFESSIONAL IS AN ARCHITECT OR ENGINEER | | LEGALLY REGISTERED UNDER THE LAWS OF | | THIS STATE REGULATING THE PRACTICE OF | | ARCHITECTURE AS PROVIDED FOR IN CHAPTER | | 481, FLORIDA STATUTES, PART 1, OR | | ENGINEERING AS PROVIDED FOR IN CHAPTER | | 471, FLORIDA STATUTES, THEN HE OR SHE | | SHALL AFFIX HIS OR HER SEAL, SIGNATURE | | AND DATE TO SAID DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA, AS | | REQUIRED BY FLORIDA STATUTES. | | | | REVIEW BY LARRY WAGNER | | (561) 805-6692 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-02-25 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-02-25 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-02-25 |
Time |
13:26 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-12-28 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-12-28 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-12-28 |
Time |
13:40 |
Sent To |
B |
|
Notes |
2007-12-28 14:21:24 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | PLUMBING PLAN REVIEW: | | DENIED: | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. SHEET P-1 PLUMBING PLAN, AND SHEET P-2 SANITARY | | RISER: THE HORIZONTAL DRY VENT FOR THE GUEST HOUSE | | SHOWER IS NOT ALLOWED PER THE FOLLOWING. | | | | 905.3 VENT CONNECTION TO DRAINAGE SYSTEM. | | EVERY DRY VENT CONNECTING TO A HORIZONTAL DRAIN SHALL | | CONNECT ABOVE THE CENTERLINE OF THE HORIZONTAL DRAIN | | PIPE. | | | | 905.4 VERTICAL RISE OF VENT. | | EVERY DRY VENT SHALL RISE VERTICALLY TO A MINIMUM OF 6 | | INCHES (152 MM) ABOVE THE FLOOD LEVEL RIM OF THE | | HIGHEST TRAP OR TRAPPED FIXTURE BEING VENTED. | | EXCEPTION: VENTS FOR INTERCEPTORS LOCATED OUTDOORS. | | | | 2. SHEET P-1 PLUMBING PLAN AND SHEET P-2 SANITARY | | RISER: TWO-WAY CLEANOUTS ARE REQUIRED FOR THE ADDITION | | AND GUEST HOUSE SANITARY SYSTEM PER THE FOLLOWING. | | | | 708.3.5 BUILDING DRAIN AND BUILDING SEWER JUNCTION. | | THERE SHALL BE A CLEANOUT NEAR THE JUNCTION OF THE | | BUILDING DRAIN AND THE BUILDING SEWER. THE CLEANOUT | | SHALL BE EITHER INSIDE OR OUTSIDE THE BUILDING WALL AND | | SHALL BE BROUGHT UP TO THE FINISHED GROUND LEVEL OR TO | | THE BASEMENT FLOOR LEVEL. AN APPROVED TWO-WAY CLEANOUT | | IS ALLOWED TO BE USED AT THIS LOCATION TO SERVE AS A | | REQUIRED CLEANOUT FOR BOTH THE BUILDING DRAIN AND | | BUILDING SEWER. THE CLEANOUT AT THE JUNCTION OF THE | | BUILDING DRAIN AND BUILDING SEWER SHALL NOT BE REQUIRED | | IF THE CLEANOUT ON A 3-INCH (76 MM) OR LARGER DIAMETER | | SOIL STACK IS LOCATED WITHIN A DEVELOPED LENGTH OF 10 | | FEET (3048 MM) OF THE BUILDING DRAIN AND BUILDING SEWER | | CONNECTION. THE MINIMUM SIZE OF THE CLEANOUT AT THE | | JUNCTION OF THE BUILDING DRAIN AND BUILDING SEWER SHALL | | COMPLY WITH SECTION 708.7 . | | | | 3. SHEET P-1 PLUMBING PLAN AND SHEET P-2 SANITARY | | RISER: PLEASE INDICATED THAT THE SANITARY CONNECTION | | FROM THE ADDITION AND GUEST HOUSE TO THE EXISTING | | SYSTEM SHALL CONNECT DOWNSTREAM OF THE EXISTING WET | | VENTED BATHROOM PER THE FOLLOWING. | | | | 909.1 WET VENT PERMITTED. | | ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS | | LOCATED ON THE SAME FLOOR LEVEL ARE PERMITTED TO BE | | VENTED BY A WET VENT. THE WET VENT SHALL BE CONSIDERED | | THE VENT FOR THE FIXTURES AND SHALL EXTEND FROM THE | | CONNECTION OF THE DRY VENT ALONG THE DIRECTION OF THE | | FLOW IN THE DRAIN PIPE TO THE MOST DOWNSTREAM FIXTURE | | DRAIN CONNECTION TO THE HORIZONTAL BRANCH DRAIN. ONLY | | THE FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT | | TO THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY | | ADDITIONAL FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE | | WET VENT. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | EXAMINER FOR REFERENCE FOR THE | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2009-03-03 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-03-03 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-03-03 |
Time |
11:24 |
Sent To |
E |
|
Notes |
2009-03-03 11:55:04 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | | | 3. INDICATE ON THE SURVEY THE SETBACK DIMENSIONS FROM | | THE PROPOSED CARPORT AND FRONT PORCH TO ALL ADJACENT | | PROPSETY LINES. | | | | 4. PROVIDE THE TOTAL HEIGHT OF THE PROPOSED ADDITION ON | | THE ELEVATION PLAN. PURSUANT TO THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-611, THE | | HEIGHT SHALL BE MEASURED AS THE VERTICAL DISTANCE FROM | | THE AVERAGE ELEVATION OF THE FINISHED GRADE OF THE | | BUILDING TO THE MEAN HEIGHT LEVEL BETWEEN EAVES AND | | RIDGE FOR GABLE, HIP, AND GAMBREL ROOFS. | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | GENERATE ADDITIONAL COMMENTS. | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | PLANNING DEPARTMENT WEBSITE AT | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1444 OR (561) 805-6720 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2008-02-20 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-02-20 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-02-20 |
Time |
09:13 |
Sent To |
E |
|
Notes |
2008-02-20 09:19:29 | ***APPROVED - RESUB #1*** | | | | PROVISO:AS THE LOT FAILS TO MEET THE ADDITIONAL | | STANDARDS FOUND IN SECTION 94-303 OF THE CITY'S ZONING | | AND LAND DEVELOPMENT REGULATIONS:THE ACCESSORY | | STRUCTURE SHALL NOT BE USED AS A SEPARATE DWELLING | | UNIT, AND NO RENTAL LICENSE SHALL BE ISSUED FOR THE | | ACCESSORY STRUCTURE. | | | | | | | | SENT TO "E" - BT (DP OUT) |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-12-21 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-12-21 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-12-21 |
Time |
09:57 |
Sent To |
E |
|
Notes |
2007-12-21 10:09:19 | ***FAILED*** | | | | | | 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY. | | | | 2)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | EQUIPMENT TO THE PROPERTY LINES.AS PER SECTION | | 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT | | PROJECT MORE THAN 4' INTO A REQUIRED SETBACK. | | | | 3)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF | | THE PROPOSED WORK EXCEEDS 50% OF THE BUILDING'S VALUE, | | LANDSCAPING SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDRS.PLEASE | | SUBMIT A LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTION | | 94-442 AND 94-445 OF THE ZLDRS. | | | | 4)INDICATE SETBACK DIMENSIONS FROM PROPOSED MAIN | | HOUSE ADDITION TO PROPERTY LINES. | | | | 5)THE SQUARE FOOTAGE OF THE EXISTING PAVING IS SHOWN | | ON SHEET SP-1, HOWEVER THE PROPOSED IS NOT.INDICATE | | PROPOSED SQUARE FOOTAGE OF DRIVEWAY, INCLUDING WALKWAY | | AND ANY OTHER IMPERMEABLE SURFACE WITHIN THE FRONT | | YARD. | | | | 6)THE MAIN HOUSE ROOF PLAN (SHEET A-2) SHOWS | | ADDITION OVERHANG AS 2'8" , THE MAIN HOUSE WALL SECTION | | (SHEET A-5) SHOWS THE OVERHANG AS 2'0" ...PLEASE | | CLARIFY. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 |
|
|