Plan Review Details - Permit 07120262
Plan Review Stops For Permit 07120262
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2008-01-10 Cont ID  
Sent By lursu Date 2008-01-10 Time 08:54 Rev Time 0.00
Received By lursu Date 2008-01-10 Time 08:54 Sent To  
Notes
2008-01-10 09:00:10***PASSED***
  
 THE UNITY OF TITLE AND SITE PLANS WERE APPROVED BY
 PLANNING AND ZONING DEPARTMENT THEREFORE THE NEW
 ADDRESS HAS BEEN APPROVED .FOR INTERNAL PERMIT PURPOSES
 ,A GROUP RECORD WAS CREATED SINCE THIS PROJECT INCLUDES
 NINE PROPERTIES .ALL PERMITS AND PROJECTS WILL BE
 ASSIGNED TO THIS GROUP ID : GRAMERCY COURT RESIDENCES
 INSTEAD OF USING A SINGLE PARCEL RECORD .
  
 AS SOON AS THE NEW PARCEL CONTROL NUMBER WILL BE ISSUED
 BY THE PROPERTY APPRAISER'S OFFICE AN ADDRESS
 NOTIFICATION LETTER CONTAINING THE NEW SITE ADDRESS
 WILL BE SENT TO THE PROPERTY OWNER .
  
 QUESTION/COMMENTS:
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2008-01-04 Cont ID  
Sent By lursu Date 2008-01-04 Time 10:18 Rev Time 0.00
Received By lursu Date 2007-12-28 Time 13:03 Sent To  
Notes
2008-01-04 10:22:32***FAILED***
  
 APPROVED SITE PLANS BY PLANNING AND ZONING ARE REQUIRED
 ALONG WITH UOT OR REPLATOF ALL PARCELS INVOLVED IN
 THIS PROJECT .AS SOON AS THESE DOCUMENTS ARE SUBMITTED
 A REVIEW OF THE SITE ADDRESS CAN BE MADE.
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-01-28 Cont ID  
Sent By jwitmer Date 2008-01-28 Time 16:29 Rev Time 8.88
Received By jwitmer Date 2008-01-28 Time 16:29 Sent To  
Notes
2008-01-28 16:57:39BUILDING PLAN REVIEW
 PERMIT: 07120262
 ADD:2501 N FLAGLER DR
 CONT: "PLAN REVIEW- MAJOR WORKING DRAWING REVIEW
 TEL: (954)965-3636
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE W/ 2007 FBC
 REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1ST PLAN REVIEW
 ACTION: DENIED
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS,
 REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR
 REVIEW FOR PERMIT.
 IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF
 YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A
 THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID
 DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1*
 /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH
 ADMINISTRATIVE CODE.
  
 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE2007 SUPPLEMENTS PLEASE UPDATE PLANS
 TO REFLECT THE CURRENT 2004 FBC WITH 2007 SUPPLEMENTS.
  
 1F) NOTE: THE FAIR HOUSING GUIDELINES AND ANSI A
 117.1-1998 WILL BE USED IN THIS REVIEW FOR COMPLIANCE
 WITH THE FAIR HOUSING ACT. THE ANSI A 117.1 STANDARD
 CONTAINS ONLY THE TECHNICAL CRITERIA, WHEREAS THE FAIR
 HOUSING ACT, THE REGULATIONS AND THE GUIDELINES CONTAIN
 BOTH SCOPING AND TECHNICAL CRITERIA. NOTE IN THE FAIR
 HOUSING GUIDELINE WHEN THE GUIDELINE REFERENCES THE
 ANSI A 117.1 IT IS THE 1986 STANDARD, NOT THE ANSI A
 117.1- 1998.
  
 2 ) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION
 THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE
 OF OCCUPANCY:
 A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT
 IS DESIGNED UPDATE WITH THE 2007 SUPPLEMENTS.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE
 PROVISIONS OF CHAPTER 3. PLEASE SEE 310.1 CONDOMINIUMS
 ARE CLASSIFIED AS R2, PLEASE CORRECT.
 SHEET A-8.04 DETAILS 7& 8 BOTH INDICATE TOWNHOUSE
 OR TOWNHOUSE CABANA, PLEASE CORRECT, THESE UNITS ARE
 NOT FEE SIMPLE ARE THEY?
 C) THE TYPE OF CONSTRUCTION AS DEFINEDIN CHAPTER 6,
 TABLE 601. PLANS INDICATE A TYPE 1 BUILDING THERE IS NO
 DESIGNATION AS TO IA OR IB.
 D) THE OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM ISPROVIDED F)
 WHETHER THE SPRINKLER SYSTEM IS REQUIRED.
 G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE
 BUILDING PERMIT
 .
 3) SHEET G-0.03 HEADINGS BOTH CLASSIFICATION AND
 RESIDENTIAL BOTH INDICATE THE OCCUPANCY CLASSIFICATION
 AS A R-1 PLEASE CORRECT TO R-2 , THE COVERSHEET
 INDICATES GRAMERCY COURT CONDOMINIUM, PLEASE CORRECT
 SEE 310.1.
  
 4) SHEET G-0.03 RESIDENTIAL HEADING CODE SECTION 1203.2
 INDICATES CEILING HEIGHTS WHILE THIS SECTION DEALS WITH
 ATTIC VENTILATION.
  
 5) SHEET G-0.03 HEADING GARAGE AGAIN TYPE I BUILDING
 INDICATE "A OR B ". TABLE 503 & TABLE 601.
  
 6) SHEET G-0.03 HEADING BUILDING INSULATION, MISSING
 SECTIONS (NEW TO THE 2004 FBC):
 A)1207.2 AIR BORNE SOUND- SHEET A-8.13 WALL
 RATINGS DO NOT PROVIDE THE (STC) RATING
 B)1207.3 STRUCTURE-BORNE SOUND, FLOOR/CEILING
 ASSEMBLIES (IIC) RATING FLOOR/CEILING ASSEMBLIES
 INDICATE CODE COMPLIANCE
  
 6) SHEET G-002 HEADING SAFEGUARDS, WRONG CODES SECTION
 AND YEAR IN THE REFERENCED STANDARD.2004 FBC CHAPTER
 35 REFERENCED STANDARDS RECOGNIZES ASCE 7-02 .ALSO
 1603.1.4 WIND DESIGN DATA.
 7)THRESHOLD INSPECTION PLANFL S. S. 553.71(7) "
 THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH
 HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN
 THE
 FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN AREA
 AND AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS.
  
 105.13.1 THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL
 INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A
 THRESHOLD BUILDING PURSUANT TO A STRUCTURALINSPECTION
 PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING
 AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR
 THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE
 OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE
 SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT
 THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE
 WITH THE PERMITTED DOCUMENTS.
  
 8) THRESHOLD INSPECTOR:
 WPB AMENDMENT 105.13.6. W.P.B. CONSTRUCTION SERVICES
 DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL
 INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA
 STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS
 CODE. CONTACT HAROLD PISKURA MANAGER OF THE SPECIAL
 INSPECTOR PROGRAM AT (561)805-6711 FOR FURTHER
 INFORMATION BEFORE
 THE PERMIT MAY BE ISSUED.
  
 9) THRESHOLD BLDG, REQUIRED STATEMENT:
 W.P.B. AMENDMENT 105.13.4.4 ALL PLANS FOR THE
 BUILDING WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY
 THE ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S
 KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
 APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE
 LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633
 FLORIDA STATUTE.
  
 10A)PLEASE PROVIDE (3) ORIGINAL SIGNED AND EMBOSSED
 SEAL SOILS REPORTS. 1802.2.1 QUESTIONABLE SOIL. WHERE
 THE SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR
 WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED
 IN THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL
 REQUIRE THAT THE NECESSARY INVESTIGATION BE MADE. SUCH
 INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF
 SECTIONS 1802.4 THROUGH 1802.6.
  
 10B) 1802.2.3 GROUND-WATER TABLE. A SUBSURFACE SOIL
 INVESTIGATION SHALL BE PERFORMED TO DETERMINE WHETHER
 THE EXISTING GROUND-WATER TABLE IS ABOVE OR WITHIN 5
 FEET (1524 MM) BELOW THE ELEVATION OF THE LOWEST FLOOR
 LEVEL WHERE SUCH FLOOR IS LOCATED BELOW THE FINISHED
 GROUND LEVEL ADJACENT TO THE FOUNDATION.
 EXCEPTION: A SUBSURFACE SOIL INVESTIGATION SHALL NOT BE
 REQUIRED WHERE WATERPROOFING IS PROVIDED IN ACCORDANCE
 WITH SECTION 1807 .
 10C)SHEET S1.2 INDICATES THAT GROUND WATER MAY BE AN
 ISSUE IN TIMES OF STORM EVENTS.
 PLEASE SEE 1807.2 DAMPPROOFING, 1807.3. WATERPROOFING
 REQUIRED.
  
 11) NOTE INFORMATIONAL,109.3.10* IMPACT OF
 CONSTRUCTION. ALL CONSTRUCTION ACTIVITY REGULATED BY
 THIS CODE SHALL BE PERFORMED IN A MANNER SO AS NOT TO
 ADVERSELY IMPACT THE CONDITION OF ADJACENT PROPERTY,
 UNLESS SUCH ACTIVITY IS PERMITTED TO AFFECT SAID
 PROPERTY PURSUANT TO A CONSENT BY THE APPLICABLE
 PROPERTY OWNER, UNDER TERMS & CONDITIONS AGREEABLE TO
 THE APPLICABLE PROPERTY OWNER. THIS INCLUDES BUT IS NOT
 LIMITED TO THE CONTROL OF DUST, NOISE, WATER OR
 DRAINAGE RUN-OFF, DEBRIS, AND THE STORAGE OF
 CONSTRUCTION MATERIALS. NEW CONSTRUCTION ACTIVITY SHALL
 NOT ADVERSELY IMPACT HISTORIC SURFACE WATER DRAINAGE
 FLOWS SERVING ADJACENT PROPERTIES, & MAY REQUIRE
 SPECIAL DRAINAGE DESIGN COMPLYING WITH ENGINEERING
 STANDARDS TO PRESERVE THE POSITIVE PATTERNS OF THE
 AFFECTED SITES. ACCORDINGLY, DEVELOPERS, CONTRACTORS,
 AND OWNERS OF ALL NEW RESIDENTIAL DEVELOPMENT,
 INCLUDING ADDITIONS, POOLS, PATIOS, DRIVEWAYS, DECKS,
 OR SIMILAR ITEMS, ON EXISTING PROPERTIES RESULTING IN A
 DECREASE IN EXCESS OF 800SQ FT OF PERMEABLE LAND AREA
 ON ANY PARCEL SHALL AS A PERMIT CONDITION, PROVIDE A
 PROFESSIONALLY PREPARED DRAINAGE PLAN CLEARLY
 INDICATING COMPLIANCE WITH THIS PARAGRAPH. UPON
 COMPLETION OF THE IMPROVEMENT, A CERTIFICATION FROM A
 LICENSED ENGINEER SHALL BE SUBMITTED TO THE INSPECTOR
 IN ORDER TO RECEIVE APPROVAL OF THE FINAL INSPECTION.
  
 12) NOTE INFORMATIONAL, 109.3.10.1 HURRICANE
 PROTECTION. IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 ALLOW CONSTRUCTION RELATED MATERIALS EQUIPMENT AND
 DEBRIS TO REMAIN LOOSE OR OTHERWISE UNSECURED AT A
 CONSTRUCTION SITE FROM 24 HRS. AFTER A HURRICANE WATCH
 HAS BEEN ISSUED UNTIL THE HURRICANE WATCH OR WARNING
 HAS BEEN LIFTED. ALL SUCH CONSTRUCTION MATERIALS,
 EQUIPMENT AND DEBRIS SHALL BE EITHER REMOVED FROM THE
 CONSTRUCTION SITE OR SECURED IN SUCH A MANNER AS TO
 MINIMIZE THE DANGER OF SUCH CONSTRUCTION MATERIALS,
 EQUIPMENT AND DEBRIS CAUSING DAMAGE TO PERSONS OR
 PROPERTY FROM HIGH WINDS. ANY PERSONS WHO FAILS TO
 COMPLY TO REMOVE OR SECURE THE CONSTRUCTION MATERIALS
 EQUIPMENT AND DEBRIS WITHIN 24 HRS AFTER A HURRICANE
 WATCH HAS BEEN ISSUED SHALL BE SUBJECT TO A FINE NOT TO
 EXCEED $500.00.IN ADDITION TO THE ABOVE, A LICENSED
 CONTRACTOR WHO VIOLATES THIS SECTION SHALL BE SUBJECT
 TO DISCIPLINE PURSUANT TO SECTION 113 OF THIS CHAPTER.
  
 13) SHEET A-1.00: BASIC CRITERIA:
 13A)BASIC CRITERIA, PLANS DO NOT INDICATE IF THIS TYPE
 I BUILDING IS A TYPE I-A OR I-B,
 TABLE 503/ TABLE 603. COMMON TO ALL LIFE SAFETY
 SHEETS PLEASE CORRECT.
  
 13B) BASIC CRITERIA, PLANS INDICATE A R1 OCCUPANCY NOT
 A R2 OCCUPANCY SEE SECTION 310.
 CONDOMINIUMS ? R2. COMMON TO ALL LIFE SAFETY
 SHEETS, PLEASE CORRECT.
  
 13C) LIFE SAFETY LEGEND, THE FIRE WALL RATINGS SYMBOLS
 ARE SO SMALL THEY ARE ILLEGIBLE AS TO THE HOUR RATING,
 106.1.2 ADDITIONAL INFORMATION REQUIRED. 706 AND 707.
  
 14) SHEET A-1.01:
 14A) THE FIRST FLOOR PLANS DOES NOT INDICATE A SECTION
 OR NOTE THAT WILL DEAL WITH STAIRS THAT CONTINUE BELOW
 GRADE AND REQUIRED BARRIER AND SIGNAGE (STAIR# 11).
 1019.1.6 DISCHARGE IDENTIFICATION. A STAIRWAY IN AN
 EXIT ENCLOSURE SHALL NOT CONTINUE BELOW THE LEVEL OF
 EXIT DISCHARGE UNLESS AN APPROVED BARRIER IS PROVIDED
 AT THE LEVEL OF EXIT DISCHARGE TO PREVENT PERSONS FROM
 UNINTENTIONALLY CONTINUING INTO LEVELS BELOW.
 DIRECTIONAL EXIT SIGNS SHALL BE PROVIDED AS SPECIFIED
 IN SECTION 1006.3 .
  
 14B) THE LIFE SAFETY PLAN DOES NOT INDICATE TO WHICH
 STAIR THE LOWER LEVEL PARKING GARAGE WAS FIGURED TO,
 JUST THE TOTAL ALLOWABLE LOADS THE STAIRS CAN HANDLE
 AND THE ACTUAL OCCUPANT LOAD. STAIR# 11 IS CONSIDERED A
 CONVERGING STAIR WHERE THE OCCUPANT LOAD FROM ABOVE AS
 WELL AS FROM BELOW WILL BE EXITING AT THE SAME TIME,
 PLEASE INDICATE THE OCCUPANT LOAD FROM BOTH THE LOWER
 LEVEL AND WORST CASE FLOOR LEVEL, MEZZANINE LEVEL,
 PLEASE INDICATE HOW YOU MEET CODE COMPLIANCE?1004.5
 EGRESS CONVERGENCE.
 WHERE MEANS OF EGRESS FROM FLOORS ABOVE AND BELOW
 CONVERGE AT AN INTERMEDIATE LEVEL, THE CAPACITY OF THE
 MEANS OF EGRESS FROM THE POINT OF CONVERGENCE SHALL NOT
 BE LESS THAN THE SUM OF THE TWO FLOORS.
  
 15) SHEET A-102:
 15A) PLEASE PROVIDE THE SQUARE FOOT CALCULATIONS FOR
 THE FIRST FLOOR LOBBY AND THE MEZZANINE LEVEL, IT
 APPEARS TO BE OVER THE 1/3RD FLOOR AREA FOR A
 MEZZANINE. 505.2 AREA LIMITATION.
  
 15B) THE AREA IN QUESTION, THE LOBBY & MEZZANINE, ARE
 OVER THE ALLOWABLE 1/3RD AREA THEN THIS AREA DOES
 QUALIFY AS A 2 STORY ATRIUM. THEN THE REQUIREMENTS OF
 404 WOULD NEED TO BE MET. . CONVERGENCE
  
 16) SHEET A-102 & A-2.2.2 THE RECREATION ROOM# 217 DOES
 NOT PROVIDE THE SQUARE FOOTAGE OR OCCUPANT LOAD FOR
 THIS ROOM, PLEASE PROVIDE.2,115 SQ FT / 7= 303
 OCCUPANT LOAD. PLEASE SEE TABLE 1014.1 REQUIRING TWO
 MEANS OF EGRESS .
  
 17)SHEET A-102 & A-2.22 THE RECREATION ROOM# 217
 DOES NOT INDICATE WALL TYPE AND FIRE RATINGS WITH WALL
 TAGS, PLEASE PROVIDE FOR CODE COMPLIANCE.
  
 18) SHEET A-101 & A-2.12 STAIR# 11DOOR 150 SWINGS
 AGAINST THE EGRESS PATTERN WITH AN OCCUPANT LOAD
 GREATER THAN 50. 108.1.2. PLEASE CORRECT.
  
 19)SHEET A-2.10:
  
 19A)THE HANDICAPPED RAMP THAT LEADS INTO THE CORRIDOR
 101 PLEASE PROVIDE THE WIDTH OF THE RAMP AND DIMENSIONS
 FOR THE TOP LANDING, BOTTOM LANDING AND TURNING RADII
 LOCATED AT BOTH ENDS OF THE RAMP. PLANS INDICATE SEE
 A-2.12 FOR RAMP DETAILS AND DIMENSIONS. PLEASE SEE FAIR
 HOUSING GUIDELINES ANSI 4.8. 405.7.4 CHANGE IN
 DIRECTION.
  
 19B) STAIR NUMBER (1) DETAILS FOUND ON A-5.01.1 DETAIL
 2AT DOOR 105 DOES NOT DEPICT THE
 HANDRAIL ACCURATELY, IT EXTENDS PAST THE STEP THE
 REQUIRED 11? BUT DOES NOT PROJECT THE HORIZONTAL 12?
 SEE FIGURE 505.10.3.BOTTOM HANDRAIL EXTENSIONS AT
 STAIRS. THIS IS COMMON TO A LOT OF STAIRS WHERE AND
 DOORWAYS OCCUR. SEE SHEET A-5.10 THIS IS ONE SHEET
 WHERE THE 11? THAT EXTENDS BEYOND THE FIRST RISER DOES
 NOT EVEN HAVE ENOUGH ROOM. ALSO SEE 1009.11.5 CONTINUE
 TO SLOPE FOR THE DEPTH OF ONE TREAD BEYOND THE BOTTOM
 RISER. THIS COMMENT WILL NOT BE COPIED FOR EACH
 INSTANCE WHERE A CODE VIOLATION OCCURS. THIS SITUATION
 DOES OCCUR REPEATEDLY.
  
 19C) SHEET A-5.10 STAIR 13 LOWER LEVEL ALSO HAS A
 COLUMN THAT STICKS INTO THE CLEAR WIDTH OF THE STAIR
 WAY REDUCING THE EFFECTIVE WIDTH OF THE STAIR, THE LIFE
 SAFETY PLAN DOES NOT INDICATE THE AMOUNT OF OCCUPANTS
 PER STAIR, 1003.3.3 HORIZONTAL PROJECTIONS.
 ELEMENTS CANNOT PROJECT OVER A WALKING SURFACE MORE
 THAN 4 INCHES (102 MM) WHEN THEY ARE LOCATED BETWEEN 27
 AND 80 INCHES (686 AND 2032 MM) ABOVE THE FLOOR.
 HANDRAILS CAN PROJECT UP TO 4 ? INCHES (114 MM) FROM
 THE WALL.
  
 19D) DETAILS A-5.02 STAIRWAYS DETAIL 3 & 6 DO NOT MEET
 THE FAIR HOUSING ANSI A-117.1 SECTION DOES NOT MEET THE
 REQUIREMENTS OF 404.2.6 TWO DOORS IN SERIES. THIS
 COMMENT WILL NOT BE COPIED FOR EACH INSTANCE WHERE A
 CODE VIOLATION OCCURS. THIS SITUATION DOES OCCUR
 REPEATEDLY.
  
 20) SHEET A-3.10
 20A) SOME OF THE A/C CLOSETS IN THE EXIT ACCESS
 CORRIDORS ARE MISSING THE DOOR IDENTIFICATION NUMBER,
 AND OTHERS SUCH AS DOOR 11 & 16 DO NOT SHOW UP ON THE
 DOOR SCHEDULE FOR THE COMMON AREAS. 106.1.2 ADDITIONAL
 INFORMATION REQUIRED.
  
 20B) IN THE AREAS AROUND THE A/C CLOSETS IT CAN NOT BE
 DETERMINED WHERE THE RATED WALL IS LOCATED , NO WALL
 MARKERS AND THE DOORS DO NOT SHOW UP ON THE DOOR
 SCHEDULE TO INDICATE FIRE RATINGS, PLEASE PROVIDE BOTH
 THE DOOR IDENTIFICATION AND WALL RATINGS, 106.1.2
 ADDITIONAL INFORMATION REQUIRED, TABLE 1016 & TABLE
 715.3. SHEET A-2.10 THERE ALSO THE DOOR TAGS ARE
 MISSING.. IN OTHER AREAS WHERE THERE ARE WALL MARKERS
 IT INDICATESA 2C TYPE WALL ON THE WALL COMMON TO THE
 INDIVIDUAL UNITS, THESE WALLS ARE TO BE FIRE RATED SEE
 TABLE 1016.THIS COMMENT WILL NOT BE COPIED FOR EACH
 INSTANCE WHERE A CODE VIOLATION OCCURS. THIS SITUATION
 DOES OCCUR REPEATEDLY ON THE FIRST FLOOR.
  
 20C) THIS COMMENT WILL SERVE FOR ALL CASES WHERE THIS
 VIOLATION OCCURS. NOTICEABLY THERE IS A NUMBER OF
 VERTICAL EXITS THAT ARE LOCATED IN THE CENTER OF THE
 BUILDING AND EMPTY OUT INTO CORRIDORS THAT LEAD TO THE
 EXTERIOR OF THE BUILDING, THIS IS HOW THE PLAN IS
 CURRENTLY DEPICTED.
  
 20C) 1) NOTE ONCE YOU ARE IN A 2 HR RATED VERTICAL EXIT
 THE SAME AMOUNT OF PROTECTION AS IF IN THE VERTICAL
 EXIT (1020.1), THIS MEANS 2 HR ENCLOSURE.
  
 20C) 2) THE FLOOR, WALLS AND CEILING WILL ALL HAVE TO
 HAVE THE 2 HOUR RATING, IF THE WALLS GO ALL THE WAY UP
 TO THE FLOOR SLAB ABOVE THEN THE CEILING DOES NOT NEED
 TO BE RATED. SEE 1020.3, THERE CAN BE NO MECHANICAL
 SYSTEMS, PLUMBING, ELECTRICAL SYSTEMS IN THIS ENCLOSURE
 BUT THAT REQUIRED FOR THE ENCLOSURE JUST LIKE THE
 VERTICAL EXIT.
  
 20C) 3)REMEMBER THIS IS CONSIDERED AN EXTENSION TO
 THE EXIT, THE OBJECTIVE IS TO MINIMIZE FIRE FROM
 SPREADING INTO THE EXIT PASSAGEWAY AND ENDANGERING THE
 OCCUPANTS OR EVEN PREVENTING THE USE OF THE EXIT AT A
 TIME WHEN IT IS NEEDED MOST. THE LIMITATION ON OPENINGS
 APPLIES REGARDLESS OF THE FIRE PROTECTION RATING OF THE
 OPENING PROTECTIVE. ROOMS THAT NORMALLY DO NOT OPEN
 INTO THE EXIT OR EXIT PASSAGEWAY ARE BUT NOT LIMITED TO
 TOILET ROOMS, ELECTRICAL/ MECHANICAL EQUIPMENT ROOMS
 AND JANITORIAL CLOSETS. ALSO NOTE THAT ELEVATORS CAN
 NOT OPEN DIRECTLY INTO AN EXIT PASSAGEWAY PLEASE SEE
 1020.4 OPENINGS AND PENETRATIONS.
  
 20C) 4) PENETRATIONS, INTO AND OPENINGS THROUGH AN EXIT
 PASSAGEWAY ARE PROHIBITED EXCEPT FOR THE REQUIRED EXIT
 DOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR THE
 INDEPENDENT PRESSURIZATION, SPRINKLER PIPING,
 STANDPIPES, ELECTRICAL RACEWAY FOR THE FIREDEPARTMENT
 COMMUNICATION AND ELECTRICAL RACEWAY SERVING THE EXIT
 PASSAGEWAY AND TERMINATINGAT A STEEL BOX NOT
 EXCEEDING 16 SQ INCHES SUCHPENETRATIONS SHALL BE
 PROTECTED IN ACCORDANCE WITH 712.
  
  
  
 20D) IN REVIEWING THE WALLIDENTIFICATION FOUND ON
 SHEETA-8.1.3 THE WALLS THAT SEPARATE THE CONDO UNITS
 FROM EACH OTHER AND THE COMMON AREAS ARE MISSING THE
 SOUND TRANSMISSION COEFFICIENT, PLEASE SEE 1207
 AIR-BORNE SOUND.
  
 20E) PLEASE ALSO PROVIDE CODE COMPLIANCE FOR 1207.3
 STRUCTURAL-BORNE SOUND TRANSMISSION.
  
 20F) A-3.10 PROVIDES THE WALL TYPES FOR THE SHAFT THAT
 ENCLOSES THE TRASH CHUTE. THERE IS NO WALL
 IDENTIFICATION TAGS FOR THE SHAFT WALL SURROUNDING THE
 TRASH CHUTE.707.4 REQUIRES A 2HR FIRE RATING, PLEASE
 CORRECT. THIS COMMENT WILL NOT BE COPIED FOR EACH
 INSTANCE WHERE A CODE VIOLATION OCCURS. THIS SITUATION
 DOES OCCUR REPEATEDLY.
  
 21) SHEET A-3.13:
 21A) CORRIDOR 101 DOES NOT PROVIDE ANY WALL RATINGS NOR
 ANY DOOR IDENTIFICATION.
 707.4, TABLE 1016 & TABLE 715.3
  
 21B) STAIR# 9 AND ELEVATOR# 9 ARE MISSING WALL TAGS,
 SHAFTS, 707.4, TABLE 1016 &
 TABLE 715.3.
  
 22) SHEET A-3.14:
 22A) THERE ARE TWO RAMPS LOCATED ON THE EXTERIOR OF THE
 BUILDING, NO INFORMATION ON SLOPE OF RAMP OR HANDRAILS.
 FAIR HOUSING ANSI A117.1- 98405.7.1 SLOPE AND 405.8
 HANDRAILS.
  
 23) SHEET A3.15, PLEASE PROVIDE INFORMATION FOR THE
 WHEEL CHAIR LIFT PER FAIR HOUSING ANSI A 117.1- 408.
  
 24SHEET A-3.16:
 24A) PLANS DO NOT INDICATE WALL IDENTIFICATION TAGS FOR
 WALL RATINGS.TABLE 1016 & TABLE 715.3.
  
 24B) PLANS DO NOT PROVIDE INFORMATION FOR THE RAMP
 LOCATED ON THE EXTERIOR OF THE BUILDING. FAIR HOUSING
 ACT ANSI A117.1 SEE SECTION 405.1- 405.10.
  
 24C) PLEASE PROVIDE THE DIMENSION FROM THE EXIT DOOR TO
 THE PROPERTY LINE. 1023.3 EXIT DISCHARGE LOCATION.
 EXTERIOR BALCONIES, STAIRWAYS AND RAMPS SHALL BE
 LOCATED AT LEAST 10 FEET (3048 MM) FROM ADJACENT LOT
 LINES AND FROM OTHER BUILDINGS ON THE SAME LOT UNLESS
 THE ADJACENT BUILDING EXTERIOR WALLS AND OPENINGS ARE
 PROTECTED IN ACCORDANCE WITH SECTION 704 BASED ON FIRE
 SEPARATION DISTANCE. ALSO SEE 1023.5.2.
  
 24D) PLEASE PROVIDE THE RATING OF THE EXTERIOR WALL
 NEXT TO THE PROPERTY LINE AND OPENING PROTECTIVE. TABLE
 602 & TABLE 704.8.
  
 24E) ON THE RIGHT SIDE OF THE SHEET WHAT APPEARS TO BE
 THE PROPERTY LINE THE EXTERIOR DOORS SWING OVER THE
 PROPERTY LINE. 3202.2.
  
  
 25) SHEET A-3.18:
 25A)DEPENDING ON THE OUT COME OF COMMENT 15A-B THE
 STAIR# 11 MAY NOT BE USED AS A VERTICAL EXIT ENCLOSURE
 SINCE THE STAIR DOES NOTCONTINUE TO THE EXTERIOR OF
 THE BUILDING AND DOES CONNECT WITH THE LOWER FLOOR. IF
 THE CALCULATIONS ON THE SO CALLED MEZZANINE LEVEL ARE
 OVER 30 5 OF THE FIRST FLOOR SQUARE FOOT AREA THEN IT
 WILL BE CONSIDERED A 2ND FLOOR AND EXCEPTION 8 AND 9 OF
 1019.1 CAN NOT BE USED .
  
 25B) PLEASE INDICATE HOW THE ACCESSIBLE ENTRANCE TO THE
 RESIDENCE LOBBY, PLEASE SHOW CHANGE IN GRADE. FAIR
 HOUSING ANSIA117.1 303.1.
  
 25C) PLEASE PROVIDE INFORMATION ON THE PRIVATE
 ELEVATORS, SEE ANSI A117.1 1002.7 OR 1003.7.
  
 26) SHEET A-3.20:
 26A) PLEASE PROVIDE WALL TAGS FOR ELEVATOR# 1, TABLE
 704.8 & 1016.1.
  
 26B) PLEASE PROVIDE ADDITIONAL INFORMATION IT APPEARS
 THAT A WON DOOR IS BEING INSTALLED IN FRONT OF THE
 ELEVATOR PROVIDE RATING.
  
 26C) TRASH CHUTE DOORS 204 &205, (THIS COMMENT WILL NOT
 BE COPIED FOR EACH INSTANCE WHERE A CODE VIOLATION
 OCCURS. THIS SITUATION DOES OCCUR REPEATEDLY FOR THE
 2ND FLOOR AND FLOORS ABOVE), SEE 707.13.3. ? HR
 SELF-CLOSING OR AUTOMATIC-CLOSING UPON DETECTION OF
 SMOKE.
  
 27) SHEET A-3.23:
 27A) AT ELEVATOR# 9 THERE IS A SHAFT ENCLOSURE BUT NO
 WALL TAG INFORMATION IS PROVIDED.SEE 707.4.
  
 27B) UNIT ?G? THE A/C CLOSET IS NOT SHOWN ON THE UNIT
 DOOR SCHEDULE, CLOSET # 11 IS MARKED ON THE DOOR
 SCHEDULE AS THE A/C CLOSET, DISCREPANCY 106.1. THIS
 SITUATION DOES OCCUR REPEATEDLY AND WILL NOT BE COPIED
 FOR EACH INSTANCE.
  
 28) SHEET# A-3.26 PLEASE PROVIDE WALL IDENTIFICATION
 TAG FOR SHAFT NEXT TO STAIR# 10 AND ACROSS THE
 CORRIDOR. PLEASE SEE 707.4.
  
 29) SHEET A-3.28:
 29A) PLEASE PROVIDEFOR THE RECREATION RESTROOMS
 DIMENSIONS FOR BOTH DIRECTIONS IN THE DISABLED
 RESTROOMS AND PROVIDE THE TURNING RADIUS. FAIR HOUSING
 ACT, ANSI A117.1-303.4.1 TURNING RADIUS.
  
 29B) THE MEZZANINE LEVEL, PLEASE PROVIDE A CUT SECTION
 THROUGH THE WHAT MAY BE A HAND RAIL OR GLASS WALL,
 PLANS ARE NOT CLEAR AS TO WHAT THIS ELEMENT MAY BE?
 106.1.2 ADDITIONAL INFORMATION REQUIRED, 404.5,
 EXCEPTION# 1.
  
 29C) PLEASE PROVIDE A SECTION THROUGH AND DETAILS OF
 WHAT MAY APPEAR AS A SERVING TABLE OR POSSIBLE GALLEY
 KITCHEN, 106.1.2 ADDITIONAL INFORMATION REQUIRED.
  
 29D) PROVIDE SECTION THROUGH OF THE CURTAIN WALL SYSTEM
 AND TYPE OF GLAZING AND SAFETY GLAZING , PLEASE SEE
 2406.3.
  
 30) SHEET A3.30:
 30A) PLEASE PROVIDE IF THE SHAFT ADJACENT TO THE A/C
 CLOSET IS FOR WITHIN THE UNIT OR FOR MORE THAN 2
 FLOORS? ADDITIONAL INFORMATION REQUIRED 106.1.2. THIS
 ALSO HOLDS TRUE FOR THE SHAFT THAT IS LOCATED BETWEEN
 BEDROOMS.
  
 31) SHEET A-3.31:
 31A)PLEASE PROVIDE ADDITIONAL INFORMATION FOR THIS
 AREA, EITHER ON THE LIFE SAFETY PLAN OR THIS SHEET
 PROVIDE THE SQ FT OF THIS ROOM THE AREA IN SQ FT PER
 OCCUPANT AND THE OCCUPANT LOAD SEE TABLE 1004.1.2. WITH
 SIGNIFICANT DIFFERENCES IN SQUAREFEET AND OCCUPANT
 LOADING THAN SHEET A-1.03 A ROUGH CALCULATION OF THE
 EXTERIOR BALCONY, AND SOCIAL ROOM 5724 SQ FT / 7= 817
 OCCUPANT LOAD NEITHER THE DOORWAYS NOR STAIRS WILL
 HANDLE THIS AMOUNT OF PEOPLE. TABLE 1018.1 WOULD ALSO
 REQUIRE A THIRD EXIT. PLANS DO NOT INCLUDE TABLE AND
 CHAIR LAYOUT SO THE MORE RESTRICTIVE OCCUPANT LOADING
 OF 7 SQ FT PER PERSON WILL BE USED TO DETERMINE
 OCCUPANT LOADING.
  
 31B) THE RECREATION DECK BELOW THE FIRE RATINGS ON THE
 COLUMNS IS PROVIDED, THEY ARE MISSING ON THIS DECK,
 TABLE 601.
  
 31C) ADDITIONAL COMMENTS MAY APPEAR FROM THE NEXT
 REVIEW, PLEASE PROVIDE CUT SECTIONS AND DETAILS OF THE
 BAR AND KITCHEN ELEMENTS SO THEY MAY REVIEWED FOR FAIR
 HOUSING REQUIREMENTS, ANSI A-117.1.
  
 31D) PLANS ARE NOT CLEAR WHERE THE ROTUNDA PORTION OF
 THE SOCIAL ROOM, A HASHED LINE IN FRONT OF THE WINDOWS
 IS NOT CLEAR, IF THIS IS TRULY WHERE THE DECK STOPS AND
 THE GLASS WOULD ACTUALLY BE CURTAIN-WALL DESIGN?
 ADDITIONAL INFORMATION IS REQUIRED.106.1.2.
  
 31E) PLEASE PROVIDEFOR THE SOCIAL ROOM RESTROOMS
 DIMENSIONS FOR BOTH DIRECTIONS IN THE DISABLED
 RESTROOMS AND PROVIDE THE TURNING RADIUS. FAIR HOUSING
 ACT, ANSI A117.1-303.4.1 TURNING RADIUS.
  
 31F) THE CATERING KITCHEN INDICATES A FIRE RATED CHASE
 BUT NO WALL IDENTIFICATION TAGS ARE PROVIDED, SEE 707.4
 SHAFTS.
  
 31G) THE PLANS ARE MISSING INFORMATION ON WALL TAGS ON
 STAIR# 8, SHAFTS 707.4.
  
 32)SHEET A3.41.PLEASE REFIGURE SQUARE FOOT AREA FOR
 THIS DECK, SHEET A-1.04 INDICATES 2160 SQ FT, PLEASE
 RECALCULATE IF TABLES AND CHAIRS ARE SHOWN THEN THE 15
 SQ FT PER PERSON, NET IS ALLOWABLE, TABLE 1004.1.2 NET
 IS WALL LINE NOT CABINET LINE.
  
 33)SHEETS A-3.70-A-3.72:
 33A) INDICATE AN INTERIOR CORRIDOR WITH ELEVATOR
 LANDINGS BUT NO ELEVATOR LOBBY, PLEASE SEE 707.14.1.
  
 33B) PLANS A-3.71 AND A-3.72 INDICATE THE INTERIOR
 CORRIDOR CONTINUES BUT THE MIDDLE 7 UNITS ARE NOT
 DEPICTED, 106.1.2 ADDITIONAL INFORMATION REQUIRED.
  
 33C) UNIT DOORS ARE NOT FIRE RATED TABLE 715.3 CORRIDOR
 WALLS 1HR DOORS 20 MINUTES.
  
 33D) ELEVATOR MACHINE ROOM WALLS 2 HR RATED, OPENING
 PROTECTIVES 1 ? HR TABLE 715.3.
  
 33E) PLANS A-3.70- A-3.72 TRASH CHUTE WALLS DO NOT HAVE
 WALL IDENTIFICATION TAGS FOR FIRE RATING, 707.4.
  
 33F) PLEASE PROVIDE THE MANUFACTURERS SPECIFICATION FOR
 THE BAR-B-Q GRILL, PLANSINDICATE THE USE OF GRILL
 UNDER ROOF IN SOME CABA?AS. ADDITIONAL INFORMATION
 REQUIRED 106.1.2/
 2801.1. BARBECUES SHALL COMPLY WITH THE FLORIDA
 BUILDING CODE, MECHANICAL.
  
 34) UNIT KITCHENS:
 34A) NOTE THE PLANS DO NOT PROVIDE THE CLEAR FLOOR
 SPACE AT EACH OF THE APPLIANCES. FAIR HOUSING ANSI
 A-117.1 804.7.1. CLEAR FLOOR OR GROUND SPACE. ON ALL OF
 THE KITCHEN UNITS
 PROVIDE THE CLEAR FLOOR SPACE REQUIRED FOR EACH
 APPLIANCE ON PLANS. IF THE PARALLEL APPROACH IS
 INDICATED, NOTE THIS APPROACH IS TO BE CENTERED ON THE
 APPLIANCE.
  
 34B) PLEASE REVIEW KITCHENS FOR THE REQUIRED 40? CLEAR
 FOR GALLEY KITCHENS AND THE 60? FOR
 U-SHAPED KITCHENS NOTE THIS SPACE CAN BE REDUCED IF THE
 END OF THE U-SHAPED KITCHEN HAS A SINK AND REMOVABLE
 BASE CABINET OR A COOK TOP AND REMOVABLE BASE CABINET.
 A-3.10UNIT A-GRND INDICATES A OVEN AT THE END OF A
 U-SHAPED KITCHEN PLEASE SEE FAIR HOUSING GUIDELINES
 CHAPTER 7.
  
 34C) SHEET A-3.20 UNIT A INDICATES A OVEN AT THE REAR
 OF A 40? WIDE U-SHAPED KITCHEN, PLEASE CORRECT. SEE
 FAIR HOUSING GUIDELINES CHAPTER 7.
  
 34D) A-3.24 UNIT ?N? LESS THAN THE 40 INCHES REQUIRED
 BETWEEN COUNTERTOP AND ADJACENT WALL. ANSI A-117.1
 804.2.2/40INCHES REDUCED SPACE WITH REMOVAL BASE AT
 COUNTER COOK TOP.
  
 34E) A-3.26 UNIT ?U? AND ?U-R? LESS THAN THE 40 INCHES
 REQUIRED BETWEEN COUNTERTOP AND ADJACENT WALL. ANSI
 A-117.1 804.2.2 SEE DISHWASHER AND ADJACENT WALL.
  
 34F)A-3.31 SOCIAL ROOM BAR AND KITCHEN, THE PLANS DO
 NOT PROVIDE ANY ELEMENTS TO REVIEW
 FOR FAIR HOUSING GUIDELINES PERTAINING TO COMMON
 ACCESSIBLE AREAS. CHAPTER 2 OF THE FAIR HOUSING
 GUIDELINE.
  
 34G) A-3.41 SOCIAL DECK- PLANS ARE INCOMPLETE AS TO THE
 BAR AND GRILL AREA. THE PLANS DO NOT PROVIDE ANY
 ELEMENTS TO REVIEW FOR FAIR HOUSING GUIDELINES
 PERTAINING TO COMMON ACCESSIBLE AREAS. CHAPTER 2 OF THE
 FAIR HOUSING GUIDELINE.
  
 35) PLEASE PROVIDE THE DETAILS FOR COMPLIANCE FOR
 ELEVATOR CARS TOACCOMMODATE AMBULANCE
 STRETCHERS.3002.4.
 36) THE 500 SERIES ARCHITECTURAL SHEETS FOR STAIRWELLS
 FAIL TO PROVIDE DETAILS FOR A STANDPIPE, PLEASE PROVIDE
 COMPLIANCE WITH:905.1 GENERAL STANDPIPE SYSTEMS SHALL
 BE PROVIDED IN ALL NEW BUILDINGS IN WHICH:
 1.THE HIGHEST FLOOR IS GREATER THAN 30 FEET (9144
 MM) ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE
 ACCESS; OR
 2.THE HIGHEST FLOOR IS MORE THAN THREE STORIES
 ABOVE GRADE; OR
 3.THE LOWEST FLOOR IS MORE THAN ONE STORY BELOW
 GRADE; OR
 4.THE LOWEST FLOOR IS MORE THAN 20 FEET (6.1 M)
 BELOW GRADE.
  
 37)THE INDEX SHEET DOES NOT INDICATE THE PRESENCE OF
 FIRE SPRINKLERS.903.2.7 GROUP R
 AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE
 WITH SECTION 903.3 SHALL BE PROVIDED THROUGHOUT ALL
 BUILDINGS WITH A GROUP R FIRE AREA.
 903.6.1 ANY BUILDING WHICH IS OF THREE STORIES OR MORE
 IN HEIGHT SHALL BE EQUIPPED WITH AN APPROVED AUTOMATIC
 SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION
 903.1 .
  
 38) SHEET S).1
 38A) PLEASE UPDATE THE FBC BASE CODE TO ACCOMPANY THE
 2007 SUPPLEMENTS TO THE FBC BUILDING.
  
 38B) WIND LOADS ARE INDICATED AS FROM VARYING MEAN ROOF
 HEIGHTS, PLEASE SEE THERE CAN ONLY BE ONE MEAN ROOF
 HEIGHT OF THE BUILDING, SEE DEFINITIONS FOR MEAN ROOF
 HEIGHT. IN AS SUCH THE BUILDING MEAN ROOF HEIGHT
 (HIGHEST ROOF) WILL BE USED FOR THE NEGATIVE PRESSURES
 ON THE BUILDING. THE POSITIVE PRESSURES DO BUILD FROM
 THE GRADE AND BUILD AS THE HEIGHT OF THE BUILDING
 INCREASES.
  
 39) S1.1B PLEASE PROVIDE ADDITIONAL INFORMATION AS TO
 THE SHEET PILE LOCATED ON THIS SHEET.
 PLANS INDICATE SHEET PILE BY OTHERS. PLEASE PROVIDE
 INFORMATION 106.1.2. 1808.2.21 PIER OR PILE LOCATION
 PLAN. A PLAN SHOWING THE LOCATION AND DESIGNATION OF
 PIERS OR PILES BY AN IDENTIFICATION SYSTEM SHALL BE
 FILED WITH THE BUILDING OFFICIAL PRIOR TO INSTALLATION
 OF SUCH PIERS OR PILES. DETAILED RECORDS FOR PIERS OR
 INDIVIDUAL PILES SHALL BEAR AN IDENTIFICATION
 CORRESPONDING TO THAT SHOWN ON THE PLAN.
  
 40) 1609.1.4 PROTECTION OF OPENINGS IN WIND-BORNE
 DEBRIS REGIONS, EXTERIOR GLAZING THAT RECEIVES POSITIVE
 PRESSURE IN THE LOWER 60 FEET (18.3 M) IN BUILDINGS
 SHALL BE ASSUMED TO BE OPENINGS AND THE BALANCE OF
 GLAZED OPENINGS IN THE REST OF THE BUILDING SHALL BE
 ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT RECEIVES
 POSITIVE PRESSURE IS IMPACT RESISTANT OR PROTECTED WITH
 AN IMPACT RESISTANT COVERING MEETING THE REQUIREMENTS
 OF SSTD 12, ASTM E 1886 ANDASTM E 1996, OR MIAMI-DADE
 TAS 201, 202 AND 203 REFERENCED THEREIN AS FOLLOWS: 1.
 GLAZED OPENINGS LOCATED WITHIN 30 FEET (9.1 M) OF GRADE
 SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST.
 2.GLAZED OPENINGS LOCATED
 MORE THAN 30 FEET (9.1 M) ABOVE GRADE SHALL MEET THE
 PROVISIONS OF THE SMALL MISSILE TEST.
  
 41)FL BLD CODE 1609.1.4: COMPONENTS & CLADDING,
 PROVIDE 2 COPIES,
 3 IF THRESHOLD OR RESIDENT INSPECTOR OF PRODUCT TESTING
 REPORTS, MISSING REPORTS ARE AS FOLLOWS:
 A) FIXED GLASS
 B) STOREFRONT
 C) OPERABLE WINDOWS
 D) MULLIONS
 E) GLAZED SWING DOORS SINGLE AND PAIRS
 F) GLAZED DOORS W EITHER SIDELIGHTS AND OR TRANSOMS
 NOTE PRODUCT APPROVAL MAY OR MAY
 NOT INCLUDE MULLIONS
 F) GLAZED AUTOMATIC BYPASS DOORS
 G) EXTERIOR METAL EXTERIOR DOORS
 H)OVERHEAD GARAGE DOORS
 I) LOUVERS
 J) EFIS WALL SYSTEMS
 K) ROOF TOP A/C PRE-ENGINEERED STANDS
 L) WOOD CONNECTORS AND ANCHORS
 M) ROOFING ASSEMBLIES
  
 42)PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO
 COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE
 APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER
 SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL,
 SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR
 SITE SPECIFIC FORM PER RULE 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 43) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 44) 1714.5.5 MULLIONS OCCURRING BETWEEN INDIVIDUAL
 WINDOW AND GLASS DOOR ASSEMBLIES. 1714.5.5.1 MULLIONS.
 MULLIONS, OTHER THAN MULLIONS WHICH ARE AN INTEGRAL
 PART OF A WINDOW OR GLASS DOOR ASSEMBLY TESTED AND
 LABELED IN ACCORDANCE WITH SECTION 1714.5.2.1 , SHALL
 BE TESTED BY AN APPROVED TESTING LABORATORY OR BE
 ENGINEERED IN ACCORDANCE WITH ACCEPTED ENGINEERING
 PRACTICE. BOTH METHODS SHALL USE PERFORMANCE CRITERIA
 CITED IN SECTIONS 1714.5.5.2 , 1714.5.5.3 AND
 1714.5.5.4 .
  
 45)THE PRODUCT APPROVALS NOW REQUIRE MULLIONS TO BE
 ATTACHED TO THE STRUCTURE.
 1714.5.5.2 LOAD TRANSFER. MULLIONS SHALL BE DESIGNED TO
 TRANSFER THE DESIGN PRESSURE LOADS APPLIED BY THE
 WINDOW AND DOOR ASSEMBLIES TO THE ROUGH OPENING
 SUBSTRATE.
 1714.5.5.4 STRUCTURAL SAFETY FACTOR.
 MULLIONS SHALL BE CAPABLE OF RESISTING A LOAD OF
 ONE-AND-ONE-HALF TIMES THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW AND DOOR ASSEMBLIES TO BE
 SUPPORTED WITHOUT EXCEEDING THE APPROPRIATE MATERIAL
 STRESS LEVELS. IF TESTED BY AN APPROVED LABORATORY, THE
 ONE AND ONE-HALF TIMES THE DESIGN PRESSURE LOAD SHALL
 BE SUSTAINED FOR 10 SECONDS, AND THE PERMANENT
 DEFORMATION SHALL NOT EXCEED 0.4 PERCENT OF THE MULLION
 SPAN AFTER THE ONE-AND-ONE-HALF TIMES DESIGN PRESSURE
 LOAD IS REMOVED.
  
 46) SHEET A-8.01 DETAIL# 19 INDICATES A WOOD BUCK WITH
 A BEVELED SIDE, PLEASE SEE 1714.5.4.2BUCKS SHALL
 EXTEND BEYOND THE INTERIOR FACE OF THE WINDOW OR DOOR
 FRAME SUCH THAT FULL SUPPORT OF THE FRAME IS PROVIDED.
 SHIMS SHALL BE MADE FROM MATERIALS CAPABLE OF
 SUSTAINING APPLICABLE LOADS, LOCATED AND APPLIED IN A
 THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS.
 ANCHORS SHALL BE PROVIDED TO TRANSFER LOAD FROM THE
 WINDOW OR DOOR FRAME ASSEMBLY TO THE SECURED WOOD BUCK.
  
  
  
 47)BEFORE ISSUANCE OF A PERMIT THE CONTRACTOR WILL
 NEED TO SUPPLY THE FOLLOWING INFORMATION FOR A BUILDING
 (ROOF) PERMIT.THIS ROOF IS MISSING OR NOT IN
 COMPLIANCE WITH THE FOLLOW ITEMS:
 ___ CONTRACTOR DID NOT INDICATE THE ROOF PITCH.
 ___ CONTRACTOR FAILED TO INDICATE WHICH SUB-SYSTEM TO
 BE USED.
 ___ THE SYSTEM PROVIDED HAS A LOWPRESSURE FOR ZONE
 _2&3__ .
 ___ THE SYSTEM PROVIDED STATESLIMITATION# 7,
 SHOULD THE FASTENERRESISTANCE BE LESS THAN THAT
 REQUIRED, AS DETERMINED BY THE BUILDING OFFICIAL, A
 REVISEDFASTENER SPACING, PREPARED , SIGNED AND SEALED
 BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER,
 REGISTERED
 ARCHITECT OR REGISTERED ROOF CONSULTANT MAY BE
 SUBMITTED.
 ___ THE SYSTEM PROVIDED INDICATES LIMITATION# 9, NO
 ENHANCED FASTENING ALLOWED.
  
 48)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED,
 IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE
 ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-01-01 Cont ID  
Sent By dpalmer Date 2008-01-01 Time 12:07 Rev Time 0.00
Received By dpalmer Date 2007-12-25 Time 14:23 Sent To  
Notes
2008-01-01 12:07:382008-01-01 12:07:38
  
 *** DENIED REVIEW ***
  
 ** IMPORTANT**
 THIS HAS ONLY BEEN SUBMITTED FOR *PLAN REVIEW* AND HAS
 NOT BEEN SUBMITTED FOR PERMIT.
  
 1) NOTE: PLEASE SEE THE FOLLOWING CODES SHALL BE STATED
 AND REFLECTED ON PLANS INCLUDING ON ELECTRICAL PLANS.
 PLEASE SEE SOME ARE ALREADY SHOWN AND SOME CODES WHICH
 ARE SHOWN ARE NOT YET ADOPTED BY THE STATE OF FLORIDA.
 PLEASE BE SURE THE FOLLOWING ARE LISTED.
 2004 FBC W/2007 SUPPLEMENTS
 2005 NFPA-70
 2003 NFPA-101
 2002 NFPA-72
 2002 NFPA-110
 2003 NFPA-20
  
 PLEASE SEE COMMENTS FROM OTHERTRADES WHICH MAY ALSO
 REQUIRE SOME CODES TO BE LISTED.
 ** PLEASE SEE SOME SHEETS FOR EXAMPLE INDICATE THE 2006
 NFPA-101. ( NOT YET ADOPTED)
 ** PLEASE SEE CODE SECTIONS REFERENCED ON THE
 ELECTRICAL PLANS ARE NOT FROM THE CURRENT NEC IN
 EFFECT. PLEASE SEE LOAD CALCULATIONS FOR EXAMPLE WHICH
 INDICATES 220.30, YET 220.30 DOES NOT EXIST UNDER THE
 2005 NEC.
  
 2) NOTE: PLEASE SEE COMMENTS FROM THE ADDRESSING
 REVIEWER ALONG WITH ANY ADDRESSING COMMENTS FROM THE
 FIRE MARSHAL OFFICE. PLEASE BE SURE TO PLACE THE
 ADJUSTED DETERMINED ADDRESS ON TITLE BLOCKS ONCE
 FINALIZED.
 FAC 61G15-23.002, 61G1-16.004
 FBC ADMIN 106.5
  
 3) NOTE: PLEASE BE SURE ALL TITLE BLOCKS ON ALL SHEETS
 CONTAIN THE PRINTED NAME OF THE DESIGNER OF RECORD.
 PLEASE SEE FOR EXAMPLE SOME SHEETS CONTAIN WHITE-OUT
 OVER WHAT USED TO BE THE PRINTED NAME OF A DIFFERENT
 ENGINEER WORKING FOR THE SAME FIRM. THIS CAN BE SEEN ON
 SHEET E-20.
 FAC 61G15-23.002
  
 4) NOTE: PLEASE SEE LANDSCAPE PLANS IN SETS SUBMITTED
 CONTAIN A *RUBBER-STAMP* FOR THE REQUIRED ORIGINAL
 SIGNATURE OF SAID DESIGNER. THIS IS STRICTLY PROHIBITED
 UNDER THE FLORIDA STATUTES AND REQUIRES AN
 *ORIGINAL/WET* SIGNATURE.
 PLEASE KNOW THIS COMMENT IS REQUIRED WHETHER OR NOT
 COMMENT IS MADE BY ANY OTHER TRADE.
 FS 481.221
  
 5) NOTE: PLEASE SEE NO LIGHTING CONTROLS FOR FBC
 CHAPTER 13, 13-415.1.ABC.1.1, .1.2 AND .1.3 WAS
 SUBMITTED OR SHOWN ON PLANS.
 AS NO SYSTEMS, DEVICES, OVER RIDES ETC WAS SHOWN IN
 DESIGN, NO REVIEW OF SAID ITEMS COULD BE DONE AT THIS
 TIME.
 PLEASE SEE ALL INFORMATION FOR MAXIMUM TIMES, ANY
 SCHEDULING ETC NEEDS TO BE SUBMITTED.
  
 6) NOTE: PLEASE SEE THE ENERGY CALCULATIONS AS THE
 INPUT DATA REPORT NEEDS TO COORDINATE WITH *ALL*
 LIGHTING ON PLANS, ALL, METHOD OF CONTROLS, TYPE OF
 FIXTURES AND WATTAGES.
 PLEASE SEE ONE EXAMPLE IS: THE EXTERIOR LIGHTING
 FIXTURES ON THE INPUT DATA REPORT ONLY SHOWS A TOTAL OF
 57 FIXTURES WHICH IS NOT POSSIBLE WHEN THE PLANS SHOW
 SUBSTANTIALLY MORE FIXTURES.
 PLEASE SEE FOR EXAMPLE: THE METHOD OF CONTROLS FOR
 INTERIOR LIGHTS IS ALL SHOWN AS MANUAL ON/OFF WHICH IS
 NOT POSSIBLE FOR ALL WHEN THE FBC CHAPTER 13 SECTIONS
 AS NOTED ABOVE REQUIRE AUTOMATED CONTROLS FOR THE
 BUILDING AND MOST LOCATIONS.
 ** PLEASE KNOW THESE ARE ONLY A COUPLE OF EXAMPLES,
 PLEASE BE SURE TO GO THROUGH ALL LIGHTING ON PLANS AND
 COORDINATE WITH THE INPUT DATA REPORT FOR *ALL*
 LIGHTING.
 13-415.1.A, 13-415.2, 13-415.2.ABC.1.2,
 13-415.2.ABC.1.3
  
 ** IMPORTANT** THIS OFFICE CAN NOT EXPRESS ENOUGH TO
 PLEASE SURE ALL LIGHTING ON PLANS MATCHES WITH THE
 INPUT DATA REPORT. THIS IS ONE ITEM WHICH IS TYPICAL OF
 HOLDING UP NUMEROUS PROJECTS FOR PERMIT ISSUANCE.
  
 ** THE LIGHTING CONTROLS FOR FBC WENT INTO EFFECT IN
 OCT 2005 UNDER THE 2004 FBC CODE CHANGE. THE FEDERAL
 REQUIREMENT WAS ADOPTED IN JULY 04.
  
 7) NOTE: PLEASE SEE HOUSE BILL 7121 AND POSSIBLE
 REQUIREMENTS FOR BUILDING.
  
 8) NOTE: PLEASE PROVIDE INFORMATION ON FAIL SAFE
 OPERATION OF ALL EGRESS DOORS WHICH ARE SHOWING ACCESS
 CONTROLS AND ALSO PARKING GATES.
 PLEASE SEE NFPA-101 7.2.1.5, 7.2.1.6.2.
 ** PLEASE ALSO SEE DOORS AT LOBBY ETC FOR EXAMPLES.
 SHEET E-1.4, AND NOTE #1.
  
 9) NOTE: PLEASE SEE THE PLANS INDICATE WHAT IS BEING A
 NATURAL GAS GENERATOR IN THE DESIGN OF THE BUILDING.
 PLEASE SEE 700.12B3, 701.11B3 AS ON-SITE FUEL WILL BE
 REQUIRED.
 PLEASE SEE COMMENTS FROM OTHER REVIEWS WITH RESPECT TO
 ANY ON-SITE FUEL TANKS FOR LP.
 PLEASE KNOW THE TRANSFER OF FUEL MUST BE BY AN
 AUTOMATIC MEANS AND SHALL NOT BE MANUAL.
 ** PLEASE KNOW THERE IS QUESTIONS OVER WHAT TYPE OF
 GENERATOR SYSTEM IS BEING PROPOSED. PLEASE IDENTIFY IF
 THIS IS INDEED A SYSTEM UNDER 700, 701 OR 702.
 IF PROPOSING A 702 SYSTEM THIS CHANGES COMMENTS AND
 WILL INDEED REQUIRE OTHER ADDITIONAL ITEMS/COMMENTS
 WHICH CAN NOT BE MADE AT THIS TIME.
 PLEASE ALSO SEE NFPA-110 AND CLASS OF SYSTEM.
  
 10) NOTE: PLEASE SEE THE MINIMUM CLEARANCE OF THE
 TRANSFER SWITCH HAS NOT BEEN MET PER NFPA-110 7.2.2.1
 AND NEC 110.26.
 ** REQUIRES TWICE THE DISTANCE.
  
 11) NOTE: PLEASE PROVIDE THE ELEVATION OF THE ANY EPSS
 EQUIPMENT PER 7.2.3.
 PLEASE BE SURE THE LEVELS MEET EITHER THE 100YR STORM
 LEVELS OR LEVELS BASED ON CAT 4, *SLOSH* CHARTS. ( SEA,
 LAKE, OVERLAND, SURGES BY HURRICANES).
  
 12) NOTE: PLEASE SEE NO INFORMATION WAS SUBMITTED FOR
 FIRE PUMP CONTROLLER, SIZE, LOCKED ROTOR CURRENTS ETC.
 PLEASE SEE NEC 695.3, 695.4 AND SEE NFPA-20 CHAPTERS 9
 AND 10. THE ENTIRE CHAPTERS ARE BEING REFLECTED AS NO
 INFORMATION WAS SUBMITTED.
  
 13) NOTE: PLEASE SUBMIT ALL MANUFACTURE SPECS/CUT
 SHEETS FOR THE GENERATOR, ATS, FIRE PUMP, FIRE PUMP
 CONTROLLER ETC.
 PLEASE SUBMIT ALSO ANY SPECS/CUT SHEETS FOR ON-SITE
 FUEL TANKS.(REVIEWED BY OTHERS).
 NEC 110.3, 90.7
 FBC 106.1.2 FOR ADDITIONAL INFORMATION.
  
 14) NOTE: PLEASE SUBMIT COMPLETED LIGHTING
 PHOTO-METRICS FOR ALL DESIGNATED EGRESS PATH UNDER
 NORMAL AND UNDER EMERGENCY CONDITIONS.
 PLEASE SEE FOR EXAMPLE THERE ARE MANY LOCATIONS WHERE
 THERE IS NO BATTERY BACK UP FIXTURES ARE BEING SHOWN.
 FOR EXAMPLE: PLEASE SEE THE STAIRS WHICH EGRESS INTO
 COURTYARD AREA, THE HALLWAYS DO NOT CONTAIN ANY BATTERY
 BACK UP FIXTURES. PLEASE SEE STAIRS 1A, 2A, 3A, 4A, 5A
 ETC.
 FOR EXAMPLE: PLEASE SEE THE STAIRS LEADING FROM THE
 UNDERGROUND PARKING TO GROUND LEVELS OUTSIDE WHICH DO
 NOT CONTAIN ANY BACK UP FIXTURES.
 FOR EXAMPLE: PLEASE SEE EGRESS AREAS ON CABANA LEVELS.
 ** PLEASE KNOW THE LEVELS FOR ALL EGRESS STAIR AREAS IS
 10FT CANDLES PER 7.8.1.3 AND IS PERMITTED DOWN TO 1FT
 CANDLE UNDER EMERGENCY CONDITIONS PER 7.9.2.2
 ** PLEASE KNOW AT THIS TIME AS NO LIGHTING LEVELS WERE
 SUBMITTED, ALL AREAS CAN NOT BE REVIEWED AT THIS TIME.
 THERE IS CONCERN OVER SOME OF THE EXAMPLES GIVEN AS
 THESE AREAS DO NOT APPEAR TO CONTAIN MINIMUM LIGHTING
 LEVELS UNDER NORMAL (OUTSIDE STAIRS).
 ** PLEASE SEE NFPA-101 7.8 AND 7.9
 ** PLEASE SEE FAC 61G15-33.004
 ** PLEASE KNOW THE FEW EXAMPLES GIVEN ABOVE ARE IN NO
 WAY ALL LOCATIONS IN WHICH CONCERN OF THE LIGHTING
 LEVELS ARE GIVEN.
  
 15) NOTE: PLEASE SEE THE FOLLOWING AREAS SHALL CONTAIN
 BATTERY BACK UP FIXTURES OF SOME KIND.
 THE MAIN ELECTRICAL ROOM, FIRE PUMP ROOM, GENERATOR
 ROOM.
 SOME OF THESE ROOMS MAY ALREADY CONTAIN FIXTURES LIKE
 THE FIRE PUMP ROOMS BUT NOT ALL.
 NFPA-101 7.9, NEC 700.16, 700.12F.
  
 16) NOTE: PLEASE ALSO PROVIDE PHOTO-METRICS FOR
 GENERATOR ROOM.THE LOCATION OF THE ROOM IS NOT YET
 FINAL HOWEVER THE LIGHTING LEVELS ARE STILL THE SAME.
 PLEASE SEE NFPA-110 7.3.3
  
 17) NOTE: PLEASE SEE NEC 620.23B FOR MINIMUM LIGHTING
 LEVELS IN ELEVATOR PIT. PLEASE SEE REFERENCE TO ASME
 A17.1-2004 AS THIS REQUIRES 5FT CANDLES MINIMUM.
  
 18) NOTE: PLEASE BE SURE TO COMPLETE ALL ROOM AND AREA
 DESIGNATIONS ON PLANS ALONG WITH ALL CIRCUITING. PLEASE
 BE SURE TO COORDINATE ALL CIRCUITING WITH THE PANEL
 SCHEDULES.
 PLEASE SEE 700.12F FOR CIRCUITING OF EMERGENCY AND EXIT
 LIGHTS.
 PLEASE SEE FOR EXAMPLE SOME UNITS ALSO ARE MISSING
 CIRCUITING ( UNIT TH, GARAGE)
 ** ONLY SOME EXAMPLES ARE GIVEN HOWEVER THERE ARE
 NUMEROUS DEVICES ON PLANS WHICH DO NOT CONTAIN A
 CIRCUIT OR NOT FOR CIRCUITING.
  
 19) NOTE: PLEASE CLARIFY HEADROOM AND ELEVATION
 CLEARANCES FOR ALL ELECTRICAL ROOMS AND ELECTRICAL
 CLOSETS. FOR EXAMPLE: PLEASE SEE MC4,5,6,7,8 AND 9 AS
 THERE APPEAR TO BE STAIRS SHOWN ABOVE THIS ROOM FOR
 NEXT LEVEL AND MAY NOT MEET 110.26.
 PLEASE PROVIDE ELEVATION OF ROOM/AREAS OF CONCERN. MAY
 BE ONE DETAIL TYPICAL OF ALL.
  
 20) NOTE: PLEASE SEE NO MORE THAN 8FT OF UNPROTECTED
 CONDUCTORS, BUS-DUCT ETC MAY BE INSTALLED INSIDE
 BUILDING. THIS INCLUDES THE BUS-DUCT SHOWN ACROSS
 CEILING IN MAIN ELECTRICAL ROOM.
 230.70, 230.71.
 90.4.
  
 21) NOTE: PLEASE SEE NFPA-72 DEFINITIONS OF SMOKE
 DETECTION TYPE DEVICES. PLEASE SEE SMOKE DETECTORS ARE
 SHOWN ON PLANS FOR UNITS ARE DEVICES WHICH ONLY
 *DETECT* AND DO NOT SOUND AN ALARM. THE PLANS HOWEVER
 SEEM TO DESCRIBE THESE AS * SMOKE ALARMS* WHICH ARE
 DEVICES THAT *DETECT AND SOUND*. PLEASE BE SURE TO
 ADJUST THE DEVICE DESIGNATIONS AND SYMBOL LEGEND ALONG
 WITH ALL NOTES.
 PLEASE SEE THE LOCATIONS OF MANY OF THESE DEVICES DO
 NOT APPEAR TO MEET 11.8.3.
 PLEASE SEE FOR EXAMPLE ANY UNITS WHICH CONTAIN AN
 ELEVATED CEILING SUCH AS A TRAY CEILING WITH A
 DIFFERENCE OF 12INCHES OR MORE WILL REQUIRE THE DEVICE
 TO BE RE-LOCATED TO THE UPPER LEVEL (HIGHEST POINT)
 SOME UNITS ALREADY HAVE THESE DEVICES IN UPPER AREA
 HOWEVER MOST DO NOT.
 PLEASE SEE NFPA-72 11.5.1.1.1, 11.8.3
  
 22) NOTE: PLEASE SEE ANY GROUND LEVEL UNITS WHICH
 CONTAIN MEANS OF EGRESS FROM UNIT WILL REQUIRE A
 LIGHTING CONTROLLED DEVICE, OUTLET AND LIGHTING FIXTURE
 OF SOME TYPE.
 PLEASE SEE UNIT *C* FOR EXAMPLE WHICH HAS DIRECT
 ACCESS.
 210.70
 LS 101 7.8
  
 23) NOTE: PLEASE SEE 240.12 AND PROVIDE SELECTIVE
 COORDINATION OF EMERGENCY SYSTEMS, EQUIPMENT, OVER
 CURRENT PROTECTION ETC.
 PLEASE ALSO SEE NFPA-110 6.5.1
  
 24) NOTE: PLEASE LABEL ALL MAINS. PLEASE SEE FOR
 EXAMPLE EM MAIN WHICH DOES NOT CONTAIN NOTE OR
 INFORMATION FOR LABELING.
 230.2E, 700.8, 701.9 ETC
  
 25) NOTE: PLEASE SEE MISSING INFORMATION FOR CDP ON
 RISER EQUIPMENT NOTES. THIS IS SHOWN AS MAIN #3,
 HOWEVER NO INFORMATION COULD BE LOCATED FOR THIS MAIN.
 PLEASE ALSO SEE THERE ARE SEVERAL OTHER METER CENTERS
 WHICH ARE NOTED TO THIS CDP YET NO SCHEDULE WAS SHOWN
 ON SHEET. THE ADP DOES HAVE THE SCHEDULE, LOAD
 CALCULATIONS AND SIZING OF EQUIPMENT ETC.?? 230.70,
 230.70, 240.4, 310.16 ETC ETC.
  
 26) NOTE: PLEASE SEE SHEET E-1.5 WHICH TITLE OF SHEET
 INDICATES POOL LEVEL, YET NO POOL SHOWN.??
 PLEASE COORDINATE ALL SHEETS AND ITEMS ON SHEETS.
 PLEASE INDICATE AND COMPLETE ANY LANDSCAPE LIGHTING.
 PLEASE KNOW ANY LANDSCAPE LIGHTING SHALL ALSO
 COORDINATE WITH THE NOTES ABOVE FOR ENERGY
 CALCULATIONS, CIRCUITING ETC.
 PLEASE SEE ALSO FOR EXAMPLE THIS SET BEING REVIEWED
 CONTAINS SHEETS E -8 AND E-9 AT THE END OF ALL
 ELECTRICAL SHEETS.
 PLEASE SEE ONLY TWO SETS SUBMITTED FOR REVIEW. PLEASE
 KNOW WHEN SUBMITTING FOR PERMIT THREE COMPLETE SETS OF
 ALL DOCUMENTS WILL BE REQUIRED.
 PLEASE BE SURE TO COORDINATE ALL SHEETS, SETS ETC. FBC
 106.1.2, 106.3.1, 106.3, 106.5 ETC
  
 27) NOTE: PLEASE SEE NOTE FOR ARC FAULT REFERENCE
 PROTECTION FOR RECEPTACLES ONLY. PLEASE SEE NEC 2005 AS
 THIS REQUIRES PROTECTION FOR ALL OUTLETS INCLUSIVE OF
 RECEPTACLES, LIGHTS, FANS, SMOKE ALARMS ETC. PLEASE SEE
 SOME UNITS DO NOT HAVE PROTECTION FOR SOME SLEEPING
 ROOMS. PLEASE SEE POSSIBLE ADAPTABLE SLEEPING ROOMS
 (UNIT *C*)?
 210.12
 PLEAS ADJUST NOTE(S).
  
 28) NOTE: PLEASE SEE CIRCUITING FOR DINING ROOMS AND
 AREAS OF THE LIKE SHALL BE ON ONE OR MORE OF THE SMALL
 APPLIANCE CIRCUITS.
 PLEASE SEE FOR EXAMPLE: UNIT DINING RECEPTACLES ON
 LIGHTING CIRCUIT.
 ** ONLY NOTED ONE EXAMPLE, HOWEVER PLEASE SEE OTHER
 AREAS AND AREAS OF THE *LIKE* SUCH AS BAR AREAS OFF
 KITCHENS.
  
 29) NOTE: PLEASE SEE 210.52C1 AND 210.8A6 AS THERE ARE
 SOME COUNTER SPACE RECEPTACLES MISSING.
 PLEASE SEE UNITS CH, CH MOD, CH MOD 2 ETC.
 THESE ARE A COUPLE OF UNITS GIVEN AS EXAMPLE.
  
 30) NOTE: PLEASE SEE POSSIBLE COUNTER SPACE AS
 PENINSULAR DESIGNATED IN UNIT *B*.
 PLEASE VERIFY 12INCHES OR MORE OF COUNTER SPACE WITH A
 SINK WHICH SEPARATES SPACE WILL REQUIRE AN ADDITIONAL
 GFI.
 PLEASE SEE 210.52C1-C5.
  
 31) NOTE: PLEASE SEE NOTES IN SQUARE BOXES ON E-10
 NOTED AS NOTE #1 AND NOTE #2.
 PLEASE SEE THESE BOXES ARE NOTED FOR UNDER CABINET
 LIGHTING WHICH WILL BE REQUIRED TO BE INCLUDED IF
 INSTALLED.
 PLEASE CLARIFY NOTE #2 AS THIS NOTES A WINE COOLER YET
 AS THE SIZE OF THIS EQUIPMENT IS NOTKNOWN, THIS MAY
 BE REQUIRED TO NOT ONLY BE A DEDICATE CIRCUIT HOWEVER
 IT WILL ALSO REQUIRE A SINGLE DEDICATE RECEPTACLE.
 PLEASE SEE PANELSCHEDULE ALREADY SHOWS DEDICATE
 CIRCUIT, THEREFORE A DEDICATED SINGLE POINT OF USE
 RECEPTACLE WILL BE REQUIRED.
 210.3, 210.20, 21, 23 ETC
  
 32) NOTE: PLEASE SEE THE GENERATOR IS BEING SHOWN AS A
 SEPARATELY DERIVED UNIT, YET NO GROUNDING ELECTRODE
 RISER AND SYSTEM IS BEING SHOWN??
 PLEASE SEE 250.50, 250.20, 250.58 ETC
 PLEASE PROVIDE CONNECTIONS AND RISER.
  
 33) NOTE: PLEASE PROVIDE A NOTE ON PLANS FOR POOL AREA
 LIGHTING TO MEET 680.22 AND 411.4AND ACTUAL DISTANCES
 DEPENDING ON THE FIXTURES BEING LOW VOLTAGE OR HIGH
 VOLTAGE.
 PLEASE SEE FOUNTAIN AREAS ALSO.
  
 34) NOTE: PLEASE PLACE NOTE ON PLANS FOR ANY PROPOSED
 LIGHTNING PROTECTION SYSTEM TO MEET NFPA-780. *WORDS TO
 THAT AFFECT*
  
 35) NOTE: PLEASE SEE SOME UNITS FOR HALLWAY/GALLERY
 AREAS FOR 10FT OR MORE OF WALL SPACE.
 PLEASE SEE 210.52H.
 PLEASE SEE FOR EXAMPLE UNIT E, AS THE LOCATION OF THE
 RECEPTACLE AS SHOWN WOULD LEAVE MORE THAN 10FT OF WALL
 SPACE WITH NO DEVICE.
 PLEASE SEE UNITS TH, TH-MOD ETC AS THE AREAS NEAR
 STAIRS ARE CONSIDERED HALLWAYS AND DO CONTAIN WALLS
 10FT OR MORE.
  
 36) NOTE: PLEASE SEE AS NOTED ABOVE THE FOR UNITS TH,
 TH_MOD ETC THE RAIL AREAS OFF STAIRS ARE CONSIDERED
 WALL SPACE PER 210.52.
 PLEASE SEE FOR EXAMPLES SOME OTHER AREAS IN WHICH WALL
 RECEPTACLES FOR TWO FEET OR MORE OF WALL ARE MISSING
 DEVICES.
 PLEASE SEE UNIT *F* BEDROOM #3, 2FT OF WALL. PLEASE SEE
 UNIT *P* 2FT OF WALL IN FAMILY ROOM. PLEASE SEE UNIT
 *B* KITCHEN WALL 2FT OR MORE.
 ** THESE ARE A FEW EXAMPLES, PLEASE GO THROUGH ALL
 UNITS.
  
 37) NOTE: PLEASE SEE UNITS WHICH SHOWS WHAT APPEARS TO
 BE A LOW VOLTAGE CONTROL PANEL IN MANY OF THE CLOSETS.
 PLEASE KNOW THAT IF THESE PANELS/UNITS CONTAIN OVER
 CURRENT PROTECTION DEVICES AND/OR TRANSFORMERS WHICH
 GENERATE A HAZARDOUS HEAT SOURCE FOR STORAGE OF
 COMBUSTIBLES THESE WILL BE REQUIRED TO BE RE-LOCATED.
 MANY OF THESE ARE NOT SHOWN NEAR SHELVING AREAS AND
 SOME ARE IN LAUNDRY ROOMS/AREAS HOWEVER NOT ALL. PLEASE
 SEE FOR EXAMPLE UNIT *J* SHOWN RIGHT ABOVE SHELF , AND
 UNIT *K* WHICH SHOWS TWO PANELS IN THE SAME UNIT.
 PLEASE SEE 240.24, 408.17, 90.4
 THIS AHJ HAS SEEN FIRST HAND FIRE HAZARDS CAUSED BY
 SOME OF THESE TYPES OF UNITS. PLEASE VERIFY UNIT,
 LISTING ETC.
  
 38) NOTE: PLEASE SEE MISSING CIRCUITING IN GARAGE UNITS
 AS NOTED ABOVE FOR COMPLETING CIRCUITING ON PLANS.
 PLEASE SEE FOR EXAMPLE: UNITS TH ETC WHICH CONTAIN WHAT
 APPEAR TO BE GDO (GARAGE DOOR OPENERS) HOWEVER NO
 DEDICATE CIRCUITS WERE SHOWN.
 PLEASE SEE 430.148 AND 210 AS THESE MAY NOT BE ON WITH
 ANY OTHER RECEPTACLES NOR CAN THEY BE ON THE LIGHTING
 CIRCUIT.
  
 39) NOTE: PLEASE SUBMIT AND COMPLETE LOAD CALCULATIONS
 FOR ALL UNITS ON SHEETS AND PANELS.
 PLEASE SEE FOR EXAMPLE: THE MISSING CALCULATIONS FOR
 PANEL/UNIT *P* ON E-19.
  
 40) NOTE: PLEASE SHOW WHERE THE SPA EQUIPMENT/MOTOR
 ACCESS IS LOCATED FOR UNITS TH-TH-MOD ETC.430.74,
 680.73, 680.44 ETC
  
 41) NOTE: PLEASE CLARIFY THE SPA ACTUAL *WATERS EDGE*.
 DETERMINATION FOR CLEARANCES FOR EQUIPMENT, LIGHTING
 CAN NOT BE DONE AT THIS TIME.
 680.42, 43
  
 42) NOTE: PLEASE SEE SHEET E-26 MAKES REFERENCE FOR
 CANDELA LEVELS TO BE ACCORDING TO NFPA-72 HOWEVER
 PLEASE SEE THE MINIMUM LEVELS FOR ADA COMPLIANCE IS
 SUBSTANTIALLY MORE RESTRICTIVE UNDER THE FLORIDA
 BUILDING CODE 11-4.
 PLEASE BE SURE TO INDICATE LEVELS PER 11-4.28.1, .2 AND
 .3(4).
 PLEASE KNOW THE MINIMUM LEVEL IN NFPA-72 IS 15CD
 WHEREAS THE MINIMUM ADA LEVEL IS 75CD IN THE FBC.
 PLEASE ADJUST DEVICES, LOCATIONS AND LEVELS PER FBC.
  
 43) NOTE: PLEASE THE CHANGES IN THE 2005 NEC FOR ALL
 RECEPTACLES WITHIN 6FT OF ANY LAUNDRY TUB WHICH
 REQUIRES ALL RECEPTACLES TO BE GFI OR GFI PROTECTED TO
 15, 20AMP AND 120V. THIS WOULD INCLUDE WASHERS AND
 OTHER RECEPTACLES LOCATED IN THE LAUNDRY ROOM.
 THE PREVIOUS CODE STILL REQUIRED NONE DEDICATE DEVICES
 IN LAUNDRY ROOMS WITHIN 6FT OF LAUNDRY TUB AND THE NEW
 CODE REQUIRES EVEN THAT OF WASHERS AND OTHER DEDICATED
 EQUIPMENT WITH THAT SAME 6FT.
 PLEASE SEE UNIT *A* FOR ONE EXAMPLE.
 PLEASE SEE NEC 210.8A7
  
 ** PLEASE KNOW AS THERE IS MUCH INFORMATION NOT YET
 DESIGNED OR SUBMITTED FOR REVIEW THERE MAY VERY WELL BE
 NEW COMMENTS ON THE NEXT REVIEW WHICH CAN NOT BE MADE
 AT THIS TIME.
  
 ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY
 QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR
 NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN
 CONTACTING THIS REVIEWER.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
2007-12-30 17:04:302007-12-30 17:04:30
  
 REVIEW TO CONTINUE 12/31
2007-12-30 12:57:502007-12-30 12:57:50
  
 REVIEW CONTINUED
2007-12-25 14:23:402007-12-25 14:23:40
  
 ONE SET IN ELECTRIC FOR REVIEW.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2008-01-15 Cont ID  
Sent By rchokshi Date 2008-01-15 Time 14:24 Rev Time 0.00
Received By rchokshi Date 2008-01-15 Time 14:22 Sent To  
Notes
2008-01-15 14:24:30FAILED FOR FOLLOWING REASONS:
  
 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI).
 PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR
 NOI.
 YOU CAN GET NOI INFO FROM
 WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/
 NOTICE OF INTENT DEP FORM 62-621.300(4)(B),
 EFFECTIVE MAY 1, 2003
  
 2. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION
 DETAILS,CLOTHES USED FOR SILT FENCE ETC., PLANS SHOWING
 SILT FENCE AROUND THE SITE & STORM CATCH BASIN DRAINS
 DURING CONSTRUCTION AND ALL DEMOLITION PHASE.HEIGHT
 OF FENCE SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST
 PARTICLES.
  
 3. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO.
 4060-07:
  
 ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH
 EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY
 APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE
 FOLLOWING:
  
 1. EROSION CONTROL, AND
 2. LAND STABILIZATION
  
 THE AMOUNT OF THE EROSION CONTROL AND LAND
 STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER
 OF RECORD USING THE CURRENT CITY COST SCHEDULE AND
 VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT.
 PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION
 SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION.
  
 UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN
 FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL
 TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE
 MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS.
  
 A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM
 THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR.
  
 4. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR
 SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP
 PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FOR ALL
 CITY STANDARDS NOTES FROM 1000, 45 STREET, ENGINEERING
 SERVICES, PHONE# 494-1040
  
 5. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE
 DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION
 MUST BE ACCESSIBLE FOR PICKUP TRUCK.
  
 6. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED
 FLOOD ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA
 AND CROWN OF THE ROAD WHEN YOU DETERMINE THE FIRST
 FLOOR ELEVATION. FIRST FLOOR ELEVATION SHOULD BE
 ATLEAST 1 FOOT HIGHER THAN HIGHEST CROWN OF THE ROAD.
  
 7. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA,
 GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREAYOU
 ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE
 THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH
 AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE
 PROVIDE A COPY OF THESE CALCULATIONS.
  
 8. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE
 SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM
 ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE
 CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING
 ELEVATION, ETC ON DRAWINGS, CALCULATION FOR
 EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET
 DETENTION AREAS IN STORM WATER CALS IF YOU HAVE ALL
 THESE. PLEASE RESUBMIT GEO-TECH REPORT AND ALL
 ENVRONMENTAL REPORT.
  
 9. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND
 YOUR SITE FOR STORM WATER DRAIN SO YOUR SITE DO NOT GET
 FLOODED AND HAVE ENOUGH DRAINS.
  
 10. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, GEO-TECH
 REPORT&STORM WATER QUALITY CALCULATIONS. STORM
 WATER CALS MUST BE APPROVED FROM 100045TH STREET
 ENGINEERING SERVICES BEFORE WE APPROVED.
  
  
 PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR
 PERMITTING PROCESS
  
 RASIK CHOKSHI805-6723

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-03-03 Cont ID  
Sent By mcarsill Date 2008-03-03 Time 11:23 Rev Time 0.00
Received By mcarsill Date 2008-03-03 Time 10:49 Sent To  
Notes
2008-03-03 11:23:021. ON PAGE A-1.00 FIRST INFORMATION BOX OF EGRESS
 CAPACITY SHOULD READ 102 NOT 112.
  
 2. WRONG LIFE SAFETY CODE LISTED ON G-0.03. IT SHOULD
 READ THE FLORIDA FIRE PREVENTION CODE, 2003 LIFE SAFETY
 CODE AND NFPA 1, 2003 EDITION.
  
 3. WET FIRE HYDRANTS ARE REQUIRED PRIOR TO, DURING, AND
 AFTER CONSTRUCTION.
  
 4. STAIRS ARE TO BE KEPT UP WITH CONSTRUCTION.
  
 5. SUITABLE ACCESS SHALL BE PROVIDED FOR FIRE AND
 PARAMEDICAL EQUIPMENT.
  
 6. TEMPORARY STANDPIPE SYSTEM REQUIRED WHEN THE
 BUILDING REACHED THREE STORIES OR THIRTY FEET IN
 HEIGHT.
  
 7. STAIRWELL IDENTIFICATION SIGNS REQUIRED IDENTIFYING
 FLOOR LEVEL, STAIR IDENTITY, AND TERMINUS TOP AND
 BOTTOM.
  
 8. SITE PLAN A-0.01 DOES NOT ILLUSTRATE ANY EXISTING OR
 NEW FIRE HYDRANTS.
  
 9. BUILDING ADDRESS REQUIRED. A MINIMUM OF AT LEAST 6"
 HIGH WITH AT LEAST 1" WIDE NUMBERS SHALL BE PROVIDED.
  
 10. KNOX-BOXES WILL BE REQUIRED FOR THE BUILDING.
  
 11. PLEASE INDICATE HOW THE PARKING CONTROL LIFT GATES
 COULD IMPACT EXISTING FROM THE GARAGE ON PAGE A-1.00.
  
 12. ELEVATOR WARNING SIGNS "IN CASE OF FIRE, DO NOT USE
 THE ELEVATORS"ARE REQUIRED.
  
 13. ALL TRASH CHUTES ARE TO COMPLY WITH NFPA 82.
  
 14. SEVERAL AREAS NOT IDENTIFIED ON PAGE A-2.10.
  
 15. ALL REQUIRED STAIRS ARE TO BE EQUIPPED WITH
 STANDPIPES.
  
 16. SEPARATE PLANS AND PERMITS REQUIRED FOR THE
 COMPLETE AUTOMATIC FIRE SPRINKLER SYSTEM.
  
 17. SEPARATE PLANS AND PERMITS REQUIRED FOR THE
 INSTALLATION OF THE COMPLETE AUTOMATIC FIRE ALARM
 SYSTEM. THE AUTOMATIC FIRE SPRINKLER AND FIRE ALARM
 SYSTEM ARE TO BE MONITORED BY A UL LISTED CENTRAL
 STATION APPROVED FOR CENTRAL STATION SERVICE.
  
 18. ELECTRIC POWERED SMOKE DETECTORS ARE REQUIRED ON
 EVERY LEVEL OF THE RESIDENTIAL UNITS.
  
 19. HOW WILL THE PRIVATE ELEVATOR LOBBIES BE ACCESSED
 BY FIRE RESCUE.
  
 20. PLEASE INDICATE WHICH ELEVATORS WILL BE STRETCHER
 ACCESSIBLE.
  
 21. WHAT IS ANY TYPES OF POOL CHEMICALS WILL BE STORED
 IN THE POOL EQUIPMENT ROOM ON PAGE A-2.5.3.
  
 22. DOOR NOTES INFORMATION BOX ON PAGE A-3.10 AND OTHER
 SHEETS, NOTE # 2 IS INCORRECT. SHOULD READ SECTION 7
 NOT 5.
  
 23. DOORS APPEAR TO SWING OVER THE PROPERTY LINE ON
 PAGE A-3.16.
  
 24. DOOR SCHEDULE ON PAGE A-3.16 CONTAINS NO
 INFORMATION.
  
 25. WHAT TYPE OF FIREWALL SEPARATION EXISTS BETWEEN THE
 ONE CAR GARAGES AND OTHER PORTIONS OF THE BUILDING.
  
 26. SOME AIR CONDITIONER DOORS LOCATED IN CORRIDORS DO
 NOT APPEAR ON THE DOOR SCHEDULE.
  
 27. DETAILS REQUIRED ON EIFS MATERIAL DISPLAYED ON THE
 PLANS. EIFS NOTED ON EXTERIOR INSULATION AND FINISH
 SYSTEM AND MISCELLANEOUS DETAILS.
  
 28. ELECTRONIC SWITCHES, CHAIN AND LOCK REQUIRED ON
 FIRE LINE BACKFLOW DEVICE.
  
 29. WHAT METHODS ARE TO BE EMPLOYED ON THE EXTERIOR
 STAIRS FOR SLIP RESISTANT METHODS.
  
 30. PLEASE PROVIDE MANUFACTURERS DETAILS FOR THE CARBON
 MONOXIDE DETECTORS.
  
 31. ALL FIRE AND SMOKE DAMPERS AFTER INSTALLATION SHALL
 BE DROP TESTED TO ENSURE PROPER OPERATION.
  
 32. ON SEVERAL ELECTRICAL SHEETS, GAS GRILLS ARE NOTED.
 THESE TYPES OF GRILLS ARE NOT PERMITTED.
  
 33. ON SP-1 ONLY A SIX INCH WATER MAIN ENTERS THE
 BUILDING. PLEASE EXPLAIN HOW THIS IS ENOUGH WATER.WHAT
 SIZE IS THE FIRE PUMP.
  
 34. KNOX-BOX LOCKING CAPS ARE TO BE PROVIDED FOR THE
 FIRE DEPARTMENT CONNECTIONS.
  
 35. PLEASE EXPLAIN WHY THE OPEN AREA IS NOT CONSIDERED
 AN ATRIUM.
  
 36. THE FLOOR PLANS APPEAR TO BE VERY CONFUSING. PLEASE
 CORRECT THE PLANS AS NECESSARY TO MAKE THEM NOT AS
 CONFUSING.
  
 37. PLEASE DECLARE IF THE BUILDING WILL BE CONSIDERED A
 HIGH-RISE STRUCTURE.
  
 38. ALL RATED FIRE WALLS NEED TO BE IDENTIFIED ON THE
 PLANS.
  
 39. WHERE WILL THE STANDPIPE HOSE VALVES BE INSTALLED
 WHEN DOUBLE DOORS OPEN INTO THE STAIRWELLS.
  
 40. PRESCRIPTIVE STRENGTH REQUIREMENTS SHALL BE NOTED
 FOR ALL HANDRAILS AND GUARDRAILS.
  
 41. PLEASE ILLUSTRATE ALL PORTABLE FIRE EXTINGUISHER
 LOCATIONS.
  
 42. PLEASE DECLARE OCCUPANCY TYPE AND USE OF THE
 BUILDING. APARTMENTS OR CONDOMINIUM AND WHAT CODE
 OCCUPANCY TYPE IS BEING ADHERED TO.
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
 804-4709 PHONE
 804-4774 FAX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By adarroug Date 2007-12-12 Time 11:20 Sent To  
Notes
2007-12-12 11:20:55TO "COMM" BD#7/PLANS ON RACK--2 LARGE ROLLS AND BINDERS

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-03-10 Cont ID  
Sent By rregueir Date 2008-03-10 Time 16:20 Rev Time 0.00
Received By rregueir Date 2008-03-05 Time 12:44 Sent To PC
Notes
2008-03-10 16:20:30REVIEW #: 1ST **PLAN CHECK ONLY**
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 NOTE: ONE SET OF MECHANICAL PLANS HAVE BEEN MARKED UP
 DURING THE COURSE OF THIS REVIEW TO ASSIST IN
 DETERMINING THE AREAS BEING ADDRESSED IN THESE REVIEW
 COMMENTS.
  
 1. PG AC-0.1: GARAGE VENTILATION SYSTEM, FLOOR PLAN
 DOES NOT SHOW ANY SOURCE OF MAKEUP AIR FOR GARAGE
 EXHAUST FANS. PROVIDE SUPPLY AIR OR MAKEUP AIR IN
 ACCORDANCE WITH FBCM 403.1.
  
 2. PG AC-0.1, AC-1.1 AND AC-1.2: PLAN CALLS FOR SUPPLY
 DUCT TO PENETRATE FLOOR/CEILING ASSEMBLY TO SUPPLY AIR
 FOR LOWER ELEVATOR LOBBIES. PLEASE COORDINATE PLANS AS
 PG AC0.1 CALLS FOR 6X6 DUCT WHILE PG AC-1.1 CALLS FOR
 6X4 DUCT.
  
 3. PG AC-0.1 AND AC-1.4: FLOOR PLAN SHOWS CONDENSER
 WATER PIPES PENETRATING A RATED STAIR ENCLOSURE AT
 STAIR #11. PENETRATIONS INTO AND OPENINGS THROUGH AN
 EXIT ENCLOSURE ARE PROHIBITED IN ACCORDANCE WITH FBCB
 1019.1.2.
  
 4. PG AC-1.1 AND AC-3.1: DUCT RISER PA-1 SHOWS TWO DUCT
 PENETRATIONS WITH ONLY ONE FIRE/SMOKE DAMPER (FSD)
 SHOWN ON FLOOR PLAN. SHAFT ENCLOSURES THAT ARE
 PERMITTED TO BE PENETRATED BY DUCTS AND AIR TRANSFER
 OPENINGS SHALL BE PROTECTED WITH APPROVED FIRE AND
 SMOKE DAMPERS INSTALLED IN ACCORDANCE WITH THEIR
 LISTING AND FBCM 607.5.5.1. THE SPECIFIC LOCATION AND
 INSTALLATION DETAILS OF EACH FIRE DAMPER AND SMOKE
 DAMPER SHALL BE SHOWN AND PROPERLY IDENTIFIED ON THE
 BUILDING PLANS BY THE DESIGNER IN ACCORDANCE WITH FBCM
 607.8.
  
 5. PG AC-1.1 AND AC-1.2: ELEVATOR MACHINE ROOM IS SHOWN
 ON CORRIDOR WITH UNIT AC-7 AND BEING CONDITIONED BY
 AC-7. ELEVATOR MACHINE ROOMS THAT CONTAIN SOLID-STATE
 EQUIPMENT FOR ELEVATOR OPERATION SHALL BE PROVIDED WITH
 AN INDEPENDENT VENTILATION OR AIR-CONDITIONING SYSTEM
 TO PROTECT AGAINST THE OVERHEATING OF THE ELECTRICAL
 EQUIPMENT IN ACCORDANCE WITH FBCB 3006.2. THIS
 CONDITION HAPPENS SEVERAL TIMES THROUGHOUT THE
 BUILDING. SHOW HOW THESE ROOMS ARE TO BE
 VENTILATED/CONDITIONED IN ACCORDANCE WITH THIS SECTION.
 ALSO, WHERE STANDBY POWER IS CONNECTED TO ELEVATORS,
 THE MACHINE ROOM VENTILATION OR AIR CONDITIONING SHALL
 BE CONNECTED TO THE STANDBY POWER SOURCE IN ACCORDANCE
 WITH FBCB 3003.1.4.
  
 6. PG AC-1.1 AND AC-1.2: WHERE SUPPLY DUCTS PENETRATE
 CORRIDOR FLOOR TO ENTER GARAGE, THESE PENETRATIONS
 SHALL BE PROTECTED WITH FIRE/SMOKE DAMPERS (FSD) IN
 ACCORDANCE WITH FBCM 607.5.4.
  
 7. PG AC-1.1, AC-1.2 AND THROUGHOUT BUILDING: OUTSIDE
 AIR INTAKES ARE SHOWN WITH ONLY MANUAL VOLUME DAMPERS.
 OUTDOOR AIR SUPPLY AND EXHAUST SYSTEMS SHALL BE
 EQUIPPED WITH MOTORIZED DAMPERS THAT WILL AUTOMATICALLY
 SHUT WHEN THE SYSTEMS OR SPACES SERVED ARE NOT IN USE.
 GRAVITY (NON-MOTORIZED) DAMPERS ARE ACCEPTABLE IN
 SYSTEMS WITH A DESIGN OUTSIDE AIR INTAKE CAPACITY OF
 300 CFM OR LESS. PROVIDE SHUTOFF DAMPER CONTROLS IN
 ACCORDANCE WITH FBCB 13-409.1.ABC.3.3. GRAVITY DAMPERS
 ARE ACCEPTABLE FOR ALL BUILDING EXHAUST SYSTEMS.
  
 8. PG AC-1.3: OUTSIDE AIR INTAKE FOR UNIT AC-10 IS
 LOCATED AT THE DRIVEWAY ENTRANCE TO THE PARKING GARAGE.
 MECHANICAL AND GRAVITY OUTSIDE AIR INTAKE OPENINGS
 SHALL BE LOCATED A MINIMUM OF 10 FEET (3048 MM) FROM
 ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS,
 CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS
 AND LOADING DOCKS IN ACCORDANCE WITH FBCM 401.5.1.
  
 9. PG AC-1.3: WOMEN?S RESTROOM EF-3 DOES NOT PROVIDE
 ADEQUATE VOLUME OF EXHAUST. FBCM TABLE 403.3 CALLS FOR
 50 CFM PER WATER CLOSET AND 50 CFM PER SHOWER HEAD FOR
 A TOTAL OF 250 CFM. EF-3 IS SHOWN TO PROVIDE 200 CFM.
 PROVIDE REQUIRED EXHAUST IN ACCORDANCE WITH THIS
 SECTION.
  
 10. PG AC-2.3: RESTROOMS BY STAIR #8, EACH RESTROOM
 SHOWS 100 CFM OF SUPPLY WITH 95 CFM OF EXHAUST. WHERE
 MECHANICAL EXHAUST IS REQUIRED BY TABLE 403.3,
 RECIRCULATION OF AIR FROM SUCH SPACES SHALL BE
 PROHIBITED. ALL AIR SUPPLIED TO SUCH SPACES SHALL BE
 EXHAUSTED, INCLUDING ANY AIR IN EXCESS OF THAT REQUIRED
 BY TABLE 403.3 IN ACCORDANCE WITH FBCM 403.2.1(3). SHOW
 EXHAUST TO BE EQUAL OR GREATER THAN THE AIR BEING
 SUPPLIED TO THE RESTROOMS.
  
 11. PG AC-2.3, AC-3.3 AND AC-4.3: SUPPLY RISER PA-2
 DUCT PENETRATION IS MISSING THE FSD. SHAFT ENCLOSURES
 THAT ARE PERMITTED TO BE PENETRATED BY DUCTS AND AIR
 TRANSFER OPENINGS SHALL BE PROTECTED WITH APPROVED FIRE
 AND SMOKE DAMPERS INSTALLED IN ACCORDANCE WITH THEIR
 LISTING AND FBCM 607.5.5.1. THE SPECIFIC LOCATION AND
 INSTALLATION DETAILS OF EACH FIRE DAMPER AND SMOKE
 DAMPER SHALL BE SHOWN AND PROPERLY IDENTIFIED ON THE
 BUILDING PLANS BY THE DESIGNER IN ACCORDANCE WITH FBCM
 607.8.
  
 12. PG AC-3.3: SUPPLY DUCTS IN RESTROOMS ARE MISSING
 SIZES. PLEASE CORRECT.
  
 13. PG AC-3.4: 24X24 SUPPLY AND RETURN DUCTS FROM AC-13
 BELOW ARE PENETRATING A RATED HORIZONTAL ASSEMBLY. DUCT
 AND AIR TRANSFER OPENINGS CONSTRUCTED OF APPROVED
 MATERIALS IN ACCORDANCE WITH THIS CODE THAT PENETRATE A
 FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY THAT
 CONNECTS NOT MORE THAN TWO STORIES IS PERMITTED WITHOUT
 SHAFT ENCLOSURE PROTECTION PROVIDED A FIRE DAMPER IS
 INSTALLED AT THE FLOOR LINE IN ACCORDANCE WITH FBCM
 607.6.1.
  
 14. PG AC-5.2: EF-3 IN RESTROOMS IS DISCHARGING INTO
 THE BOILER ROOM RATHER THAN TO THE OUTDOORS. THE AIR
 REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE
 DISCHARGED OUTDOORS IN ACCORDANCE WITH FBCM 501.2.
 ALSO, THE EXHAUST OUTLET DUCT IS PENETRATING A 2-HOUR
 RATED WALL WITHOUT AN OPENING PROTECTIVE. DUCT
 PENETRATIONS AND AIR TRANSFER OPENINGS IN FIRE BARRIERS
 SHALL BE PROTECTED WITH APPROVED FIRE DAMPERS INSTALLED
 IN ACCORDANCE WITH THEIR LISTING AND FBCM 607.5.2.
 NOTE: PG G-0.03 CALLS FOR BOILER ROOM TO HAVE 2-HOUR
 SEPARATION.
 ALSO, WILL THERE BE ANY PROVISIONS MADE FOR VENTING AND
 COMBUSTION AIR FOR THE BOILER ROOM?
  
 15. PG AC-5.4: CONDENSER WATER PIPES FROM COOLING
 TOWERS ARE SHOWN PENETRATING STAIR #12 ENCLOSURE.
 PENETRATIONS INTO AND OPENINGS THROUGH AN EXIT
 ENCLOSURE ARE PROHIBITED IN ACCORDANCE WITH FBCB
 1019.1.2.
  
 16. PG AC-7.1 AND AC-7.2: ROOMS ADJACENT TO CORRIDORS
 ARE LABELED AS ?MECH? ROOMS. IF THESE ARE ELEVATOR
 MACHINE ROOMS, AN INDEPENDENT VENTILATION OR AIR
 CONDITIONING SYSTEM IS REQUIRED FOR THESE ROOMS IN
 ACCORDANCE WITH FBCB 3006.2.
  
 17. PG AC-7.1, AC-7.2 AND THROUGHOUT BUILDING: DUCTS
 AND AIR TRANSFER OPENINGS WHICH PENETRATE FIRE RATED
 CORRIDOR ASSEMBLIES SHALL BE PROTECTED WITH SMOKE
 DAMPERS IN ACCORDANCE WITH FBCM 607.5.4 ALONG WITH FIRE
 DAMPERS IN ACCORDANCE WITH FBCM 607.5. THERE ARE
 SEVERAL DUCT PENETRATIONS AND AIR TRANSFER OPENINGS IN
 THE CORRIDORS WHICH ARE NOT PROTECTED BY SMOKE DAMPERS.
 PLEASE CORRECT. ALSO, SHOW HOW SMOKE DAMPERS ARE TO BE
 ACTUATED IN ACCORDANCE WITH FBCM 607.5.4.1.
  
 18. PG AC-8 UNIT A FLOOR PLAN: BEDROOMS 2 AND 3 SHOW
 TWO TRANSFER DUCTS COMBINING INTO ONE. THE SIZE OF THE
 COMBINED DUCT AND GRILL ARE MISSING FROM THE PLAN.
 PLEASE CLARIFY.
 NOTE: THE DUCT SHALL BE SIZED TO PROVIDE BALANCED
 RETURN IN ACCORDANCE WITH FBCM 601.4. THE COMBINED DUCT
 SIZE SHALL BE LARGE ENOUGH TO CARRY THE AIR FROM BOTH
 BEDROOMS.
  
 19. PG AC-8 UNIT A FLOOR PLAN: 6X6 SUPPLY DROP IN
 POWDER ROOM IS BEING FED FROM A 14X8 RETURN DUCT.
 PLEASE CLARIFY. THE SIZE OF THE FLEX DUCT IS ALSO
 MISSING FROM THE PLANS. AN AIR DISTRIBUTION SYSTEM
 SHALL BE DESIGNED AND INSTALLED TO SUPPLY THE REQUIRED
 DISTRIBUTION OF AIR IN ACCORDANCE WITH FBCM 603.1.
  
 20. PG AC-8 UNIT A-GROUND FLOOR PLAN: THE RETURN AIR
 TRANSFER IS TOO SMALL TO MEET THE BALANCED RETURN AIR
 EXCEPTIONS UNDER FBCM 601.4. IF TRANSFERS ARE NOT
 DESIGNED TO MEET THESE EXCEPTIONS, A FIELD TEST WILL BE
 REQUIRED AT FINAL INSPECTION TO VERIFY A PRESSURE
 DIFFERENTIAL OF 0.01 INCHES WC OR LESS.
 NOTE: THIS CONDITION OCCURS IN SEVERAL APARTMENTS AND
 SEVERAL MORE APARTMENTS HAVE MISSING DUCT SIZES, THUS
 LEAVING THE SIZE OF RETURN TRANSFER DUCTS UNDETERMINED.
 THE ABOVE APARTMENT IS USED AS AN EXAMPLE AND EACH
 INSTANCE WILL NOT BE POINTED OUT IN THIS REVIEW.
 HOWEVER, ONE SET OF PLANS HAS BEEN MARKED TO INDICATE
 AREAS WHERE THIS CONDITION OCCURS.
  
 21. PG AC-8 THROUGH AC-23: WITH A FEW EXCEPTIONS, DRYER
 EXHAUST DUCTS ON THESE PAGES EXCEED THE MAXIMUM ALLOWED
 LENGTH OF 25 FEET. THE MAXIMUM LENGTH IS FURTHER
 REDUCED BY BENDS IN ACCORDANCE WITH FBCM 504.6.1.
 EXCEPTION: WHERE THE MAKE AND MODEL OF THE CLOTHES
 DRYER TO BE INSTALLED IS KNOWN AND THE MANUFACTURER?S
 INSTALLATION INSTRUCTIONS FOR SUCH DRYER ARE PROVIDED
 TO THE CODE OFFICIAL, THE MAXIMUM LENGTH OF THE EXHAUST
 DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE PERMITTED
 TO BE IN ACCORDANCE WITH THE DRYER MANUFACTURER?S
 INSTALLATION INSTRUCTIONS. PROVIDE DRYER MANUFACTURER?S
 INSTRUCTIONS FOR REVIEW OR SHOW THE DRYER EXHAUST DUCT
 LENGTH TO BE IN COMPLIANCE WITH THIS SECTION.
  
 22. PG AC-09: DUCT AND GRILL SIZES MISSING FROM RETURN
 AIR TRANSFERS IN BOTH APARTMENT FLOOR PLANS. PLEASE
 CORRECT AND SHOW COMPLIANCE WITH FBCM 601.4.
  
 23. PG AC-10 UNIT C-GROUND: A) RETURN DUCT FROM BEDROOM
 #2 IS MISSING SIZE. SHOW COMPLIANCE WITH FBCM 601.4.
 B) 6X6 SUPPLY DROP IN BEDROOM #2 CLOSET HAS NO DUCT.
 AIR DISTRIBUTION SYSTEMS SHALL BE DESIGNED AND
 INSTALLED TO SUPPLY THE REQUIRED DISTRIBUTION OF AIR IN
 ACCORDANCE WITH FBCM 603.1.
 C) SUPPLY DROP IN BATHROOM #2 IS MISSING DUCT SIZE, CFM
 AND GRILL DESIGNATION. AIR DISTRIBUTION SYSTEMS SHALL
 BE DESIGNED AND INSTALLED TO SUPPLY THE REQUIRED
 DISTRIBUTION OF AIR IN ACCORDANCE WITH FBCM 603.1.
  
 24. PG AC-10 UNIT C-GROUND MOD 2: THE 16X8 RETURN DUCT
 PENETRATIONS IN CORRIDOR SHALL BE PROTECTED BY FIRE AND
 SMOKE DAMPERS IN ACCORDANCE WITH FBCM 607.5.4 UNLESS
 THE DUCT IS DESIGNED AND INSTALLED IN ACCORDANCE WITH
 EXCEPTION #3: SMOKE DAMPERS ARE NOT REQUIRED IN
 CORRIDOR PENETRATIONS WHERE THE DUCT IS CONSTRUCTED OF
 STEEL NOT LESS THAN 0.019 INCH (0.48 MM) IN THICKNESS
 AND THERE ARE NO OPENINGS SERVING THE CORRIDOR. SHOW
 COMPLIANCE WITH EITHER THE SMOKE DAMPER REQUIREMENTS OR
 THE EXCEPTION. IN EITHER CONDITION FIRE DAMPERS ARE
 REQUIRED IN ACCORDANCE WITH FBCM 607.5.3.
  
 25. PG AC-10 UNIT C AND UNIT C-REV FLOOR PLANS: A)
 RETURN DUCT FROM AC CLOSET INTO GREAT ROOM IS MISSING
 SIZE. PLEASE CORRECT AND SHOW COMPLIANCE WITH FBCM
 601.4.
 B) 6X6 50 CFM DUCTS PENETRATING CORRIDOR WALLS SHALL BE
 PROTECTED WITH FIRE AND SMOKE DAMPERS IN ACCORDANCE
 WITH FBCM 607.5.4.
  
 26. PG AC-11: SEVERAL RETURN AND TRANSFER DUCT GRILLS
 ARE MISSING SIZE. PLEASE CLARIFY AND SHOW COMPLIANCE
 WITH FBCM 601.4.
  
 27. PG AC-11: 20X8 RETURN DUCT PENETRATIONS IN CORRIDOR
 SHALL BE PROTECTED BY FIRE AND SMOKE DAMPERS IN
 ACCORDANCE WITH FBCM 607.5.4 UNLESS THE DUCT IS
 DESIGNED AND INSTALLED IN ACCORDANCE WITH EXCEPTION #3:
 SMOKE DAMPERS ARE NOT REQUIRED IN CORRIDOR PENETRATIONS
 WHERE THE DUCT IS CONSTRUCTED OF STEEL NOT LESS THAN
 0.019 INCH (0.48 MM) IN THICKNESS AND THERE ARE NO
 OPENINGS SERVING THE CORRIDOR. SHOW COMPLIANCE WITH
 EITHER THE SMOKE DAMPER REQUIREMENTS OR THE EXCEPTION.
 IN EITHER CONDITION FIRE DAMPERS ARE REQUIRED IN
 ACCORDANCE WITH FBCM 607.5.3.
  
 28. PG AC-11: AC-2 AND AC-6 ARE SHARING A COMMON RETURN
 AIR PLENUM AND HAVE A COMBINED CAPACITY IN EXCESS OF
 2000 CFM. WHERE MULTIPLE AIR-HANDLING SYSTEMS SHARE
 COMMON SUPPLY OR RETURN AIR DUCTS OR PLENUMS WITH A
 COMBINED DESIGN CAPACITY GREATER THAN 2,000 CFM, THE
 RETURN AIR AND SUPPLY AIR SYSTEM SHALL BE PROVIDED WITH
 SMOKE DETECTORS IN ACCORDANCE WITH SECTION 606.2.1 (SEE
 FBCM 606.2.2).
 NOTE: DUCT SMOKE DETECTORS SHALL BE CONNECTED TO THE
 FIRE ALARM SYSTEM IN ACCORDANCE WITH FBCM 606.4.1.
  
 29. PG AC-12AND AC-13 2ND FLOOR: A) RETURN DUCT AND
 GRILL FROM AC CLOSET MISSING SIZES. PLEASE CORRECT AND
 SHOW COMPLIANCE WITH FBCM 601.4.
 B) FLEX SUPPLY DUCTS ALL FLOORS ARE MISSING SIZES ON
 FLOOR PLANS. AIR DISTRIBUTION SYSTEMS SHALL BE DESIGNED
 AND INSTALLED TO SUPPLY THE REQUIRED DISTRIBUTION OF
 AIR IN ACCORDANCE WITH FBCM 603.1.
  
 30. PG AC-12 AND AC-13 3RD FLOOR: BEDROOMS DO NOT SHOW
 ANY DUCTS OR TRANSFERS FOR RETURN AIR. SHOW BALANCED
 RETURN IN THESE ROOMS IN ACCORDANCE WITH FBCM 601.4.
  
 31. PG AC-14 BOTH FLOOR PLANS: A) SEVERAL SUPPLY AND
 RETURNS ARE MISSING DUCT AND/OR GRILL SIZES ON FLOOR
 PLANS.
 B) E GROUND UNIT 14X8 RETURN TRANSFER IN BEDROOM #2 IS
 TOO SMALL TO MEET THE BALANCED RETURN EXCEPTIONS IN
 FBCM 601.4. SHOW HOW BALANCED RETURN IS TO BE ACHIEVED
 IN THIS ROOM.
 C) UNIT E FLOOR PLAN SHOWS ONE 14X8 DUCT CARRYING THE
 RETURN FOR TWO BEDROOMS. SHOW HOW BALANCED RETURN IS TO
 BE ACHIEVED FOR THESE ROOMS IN ACCORDANCE WITH FBCM
 601.4.
  
 32. PG AC-15 UNIT F: A) SUPPLY DUCT SIZE MISSING FOR
 RIGID DUCT IN KITCHEN AND FLEX DUCT FEEDING CORRIDOR.
 SHOW MISSING SIZES. AIR DISTRIBUTION SYSTEMS SHALL BE
 DESIGNED AND INSTALLED TO SUPPLY THE REQUIRED
 DISTRIBUTION OF AIR IN ACCORDANCE WITH FBCM 603.1.
 B) RETURN DUCT SIZES MISSING AT AC CLOSET AND MASTER
 BEDROOM. SHOW MISSING SIZES AND DEMONSTRATE COMPLIANCE
 WITH THE BALANCED RETURN AIR REQUIREMENTS OF FBCM
 601.4.
  
 33. PG AC-15 UNIT F GROUND: FLOOR PLAN SHOWS 14X6
 TRANSFER DUCT FOR THE MASTER BEDROOM. THIS IS TOO SMALL
 IN ACCORDANCE WITH EXCEPTION #3 OF FBCM 601.4 WHICH
 REQUIRES ALL DROPS IN THE MASTER SUITE TO BE INCLUDED.
 SHOW HOW BALANCED RETURN IS TO BE ACHIEVED IN THIS AREA
 IN ACCORDANCE WITH THIS SECTION.
  
 34. PG AC-16: UNITS G AND H DUCT SIZE MISSING ON RETURN
 FROM AC CLOSETS. SHOW COMPLIANCE WITH FBCM 601.4. ALSO,
 SUPPLY IN KITCHEN OF UNIT G IS MISSING SIZE. PLEASE
 CLARIFY.
  
 35. PG AC-17: ALL J UNITS, RETURN FROM AC CLOSETS
 MISSING DUCT AND GRILL SIZES. UNIT M RETURN DUCT FROM
 AC CLOSET IS MISSING SIZE. SHOW COMPLIANCE WITH FBCM
 601.4.
  
 36. PG AC-18: UNIT N AND UNIT N GROUND, SEVERAL SUPPLY
 AND RETURN DUCTS ARE MISSING SIZES. PLEASE CLARIFY
 SHOWING COMPLIANCE WITH FBCM 601.4 AND 603.1.
  
 37. PG AC-19: UNIT P AND UNIT P GROUND, RETURN TRANSFER
 DUCTS FROM MASTER BEDROOMS ARE TOO SMALL IN ACCORDANCE
 WITH EXCEPTION #3 OF FBCM 601.4 WHICH REQUIRES ALL
 DROPS IN THE MASTER SUITE TO BE INCLUDED. SHOW HOW
 BALANCED RETURN IS TO BE ACHIEVED IN THIS AREA IN
 ACCORDANCE WITH THIS SECTION.
  
 38. PG AC-19: UNIT R: RETURN DUCT IS MISSING FROM
 MASTER BEDROOM. ALSO, RETURN DUCT SIZE FROM AC CLOSET
 IS MISSING. SHOW COMPLIANCE WITH FBCM 601.4.
  
 39. PG AC-19: UNIT U, RETURN TRANSFER DUCTS MISSING
 FROM TWO ROOMS. SHOW HOW BALANCED RETURN IS TO BE
 ACHIEVED IN THESE AREAS IN ACCORDANCE WITH FBCM 601.4.
 ALSO, SUPPLY DUCT INTO KITCHEN IS MISSING SIZE. PLEASE
 CLARIFY. FBCM 603.1.
  
 40. PG AC-20: RETURN DUCT BETWEEN BEDROOMS 2 AND 3 IS
 MISSING DUCT AND GRILL SIZES. ALSO, SEVERAL SUPPLY FLEX
 DUCTS ARE MISSING SIZES. SUPPLY DUCT TO POWDER ROOM IS
 CONNECTED TO 14X8 RETURN AIR TRUNK LINE. SHOW BALANCED
 RETURN IN ACCORDANCE WITH FBCM 601.4. ALSO, AIR
 DISTRIBUTION SYSTEMS SHALL BE DESIGNED AND INSTALLED TO
 SUPPLY THE REQUIRED DISTRIBUTION OF AIR IN ACCORDANCE
 WITH FBCM 603.1.
  
 41. PG AC-21: SEVERAL SUPPLY AND RETURN DUCTS ARE
 MISSING DUCT AND GRILL SIZES. ALSO, RETURN FROM MASTER
 SUITE IS TOO SMALL IN ACCORDANCE WITH FBCM 601.4
 EXCEPTION #3.
  
 42. PG AC-22: A) SUPPLY DUCT SIZE MISSING FOR RIGID
 DUCT IN KITCHEN AND FLEX DUCTS FEEDING CORRIDOR.SHOW
 MISSING SIZES. AIR DISTRIBUTION SYSTEMS SHALL BE
 DESIGNED AND INSTALLED TO SUPPLY THE REQUIRED
 DISTRIBUTION OF AIR IN ACCORDANCE WITH FBCM 603.1.
 B) RETURN DUCT SIZES MISSING AT AC CLOSET AND MASTER
 BEDROOM. SHOW MISSING SIZES AND DEMONSTRATE COMPLIANCE
 WITH THE BALANCED RETURN AIR REQUIREMENTS OF FBCM
 601.4.
  
 43. PG AC-23: A) SUPPLY DUCT SIZES MISSING FROM FLEX
 DROPS IN POWDER ROOM AND AC CLOSET.
 B) SIZE IS ALSO MISSING ON RIGID DUCT IN BEDROOM #2.
 C) THE 4 INCH FLEX DUCT IN BATHROOM FOR BEDROOM #3 IS
 NOT CONNECT TO ANY SUPPLY TRUNK LINE. AIR DISTRIBUTION
 SYSTEMS SHALL BE DESIGNED AND INSTALLED TO SUPPLY THE
 REQUIRED DISTRIBUTION OF AIR IN ACCORDANCE WITH FBCM
 603.1.
 D) RETURN TRANSFER DUCT FOR MASTER BEDROOM IS MISSING
 SIZE AND APPEARS TO BE TOO SMALL FOR ALL SUPPLY DROPS
 IN THE MASTER SUITE. SHOW COMPLIANCE WITH FBCM 601.4.
 E) THERE IS A 6X6 SUPPLY GRILL SHOWN IN THE 1-HOUR
 RATED CEILING NEAR THE 32X20 RETURN DUCT IN THE
 CORRIDOR. WHERE DUCT SYSTEMS CONSTRUCTED OF APPROVED
 MATERIALS IN ACCORDANCE WITH THIS CODE PENETRATE A
 CEILING OF A FIRE-RESISTANCE-RATED FLOOR/CEILING OR
 ROOF/CEILING ASSEMBLY, AN APPROVED CEILING RADIATION
 DAMPER SHALL BE INSTALLED AT THE CEILING LINE IN
 ACCORDANCE WITH FBCM 607.6.2.
  
 44. PG AC-24 1ST FLOOR: CONDENSER WATER PIPES ARE SHOWN
 LOCATED IN ELEVATOR SHAFT. PLUMBING AND MECHANICAL
 SYSTEMS SHALL NOT BE LOCATED IN AN ELEVATOR SHAFT IN
 ACCORDANCE WITH FBCB 3004.5.
  
 45. PG AC-24 2ND FLOOR: A) ONE RIGID SUPPLY DUCT
 MISSING SIZE. B) THE 6 INCH FLEX DUCT BY STAIRS IS NOT
 CONNECTED TO ANY TRUNK LINE. AIR DISTRIBUTION SYSTEMS
 SHALL BE DESIGNED AND INSTALLED TO SUPPLY THE REQUIRED
 DISTRIBUTION OF AIR IN ACCORDANCE WITH FBCM 603.1.
 C) IT IS UNCLEAR WHETHER EF-1 IS DISCHARGING OUTSIDE OR
 INSIDE A STAIR ENCLOSURE. PLEASE CLARIFY. THE AIR
 REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE
 DISCHARGED OUTDOORS IN ACCORDANCE WITH FBCM 501.2.
  
 46. PG AC-24 3RD FLOOR: SUPPLY DUCT FEEDING CHASE IS
 MISSING SIZE. PLEASE CLARIFY.
  
 47. PG AC-42 4TH FLOOR: RETURN AIR TRANSFER DUCT IS
 MISSING GRILL SIZES. THE DUCT IS ALSO TOO SMALL FOR THE
 MASTER SUITE IN ACCORDANCE WITH FBCM 601.4 EXCEPTION
 #3.
  
 48. PG AC-24 5TH FLOOR: SUPPLY DUCT APPEARS TO BE
 LOCATED OUTDOORS AND CONDITIONING THE OUTDOORS. IS THIS
 DUCT INTENDED TO CONDITION THE TOILET ROOM ON THE 5TH
 FLOOR? PLEASE CLARIFY.
  
 49. PG AC-25: THE LAYERS ON THIS PAGE DO NOT
 CORRESPOND. A REVIEW OF THIS PAGE CAN NOT BE COMPLETED
 AT THIS TIME. IT IS LIKELY THAT SIMILAR ISSUES AS THOSE
 ON PG AC-24 WILL OCCUR ON THIS PAGE. PLEASE CLARIFY.
 FBC 106.1.1.
  
 50. PG AC-28: HEAT PUMP SCHEDULE, AC-6 EFFICIENCY
 RATING IS LESS THAN THE PRESCRIPTIVE MINIMUM AS
 REQUIRED BY FBCB TABLE 13-407.1.ABC.3.2B. SHOW
 COMPLIANCE WITH THIS SECTION.
  
 51. PG AC-29: RTU #2 SHALL BE EQUIPPED WITH AUXILIARY
 DRAIN PROTECTION, SUCH AS A WATER LEVEL DETECTION
 DEVICE, TO PREVENT OVERFLOW OF CONDENSATE FROM DRAINING
 INTO THE BUILDING IN ACCORDANCE WITH FBCM 307.2.3.
  
 52. PG AC-30: ABBREVIATIONS TABLE: THE ABBREVIATION OF
 MVD IS USED EXTENSIVELY ON PLANS YET IS NOT DEFINED IN
 THE TABLE. PLEASE CLARIFY.
  
 53. PG AC-30: THE OPERATING TEMPERATURE OF FIRE DAMPER
 ACTUATING DEVICES (SUCH AS FUSIBLE LINKS) SHALL BE
 APPROXIMATELY 50 DEGREES F ABOVE THE NORMAL TEMPERATURE
 WITHIN THE DUCT SYSTEM, BUT NOT LESS THAN 160 DEGREES F
 IN ACCORDANCE WITH FBCM 607.3.1.1(1). MATERIALS NOTE J
 CALLS FOR FIRE DAMPER FUSIBLE LINKS TO BE 265 DEGREES.
 IS THE AIR TEMPERATURE WITHIN THE DUCT SYSTEMS EXPECTED
 TO BE HOT ENOUGH TO JUSTIFY THE ELEVATED TEMPERATURE OF
 THESE FUSIBLE LINKS? PROVIDE SUPPORTING DOCUMENTATION
 IF NECESSARY TO DEMONSTRATE COMPLIANCE WITH THIS
 SECTION.
  
 54. PG AC-30: MATERIALS NOTE S CALLS FOR DRYER BOOSTER
 FANS. IF DRYER BOOSTER FANS ARE TO BE USED, PROVIDE
 DOCUMENTATION SHOWING THE BOOSTER FANS LISTED AND
 LABELED FOR USE IN A DRYER APPLICATION IN ACCORDANCE
 WITH FBCM 504.6. ALSO, PROVIDE DRYER MANUFACTURER?S
 INSTALLATION INSTRUCTIONS WHICH APPROVE THE USE OF
 EXTERNAL BOOSTER FANS. DOMESTIC DRYERS SHALL BE
 EXHAUSTED IN ACCORDANCE WITH MANUFACTURER?S
 INSTALLATION INSTRUCTIONS PER FBCM 504.1.
  
 55. PG AC-30: OUTSIDE AIR CALCULATIONS ARE MISSING
 CALCULATIONS FOR ENCLOSED PARKING GARAGE VENTILATION.
 SHOW THE VENTILATION RATE REQUIRED AT BOTH THE 0.05 CFM
 PER SQ FT AND THE 1.5 CFM PER SQ FT RATES IN ACCORDANCE
 WITH FBCM SECTION 404. THERE IS NO INDICATION THAT THE
 GARAGE EXHAUST FANS WILL RUN CONTINUOUSLY AT THE 0.05
 CFM RATE AS REQUIRED BY FBCM 404.2. SHOW COMPLIANCE
 WITH THIS SECTION.
  
 56. PG AC-31: COOLING TOWER, RTUS, WATER HEATER, ALL
 EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO
 WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND
 PRESSURES ON THE EQUIPMENT AND THE SUPPORTS AS
 DETERMINED IN ACCORDANCE WITH THE FLORIDA BUILDING
 CODE, BUILDING. ROOF-MOUNTED MECHANICAL UNITS AND
 SUPPORTS SHALL BE SECURED TO THE STRUCTURE IN
 ACCORDANCE WITH FBCM 301.13. PROVIDE DOCUMENTATION
 SHOWING ALL APPLIANCES AND EQUIPMENT IS DESIGNED AND
 CONSTRUCTED TO WITHSTAND EXPECTED WIND PRESSURES BY THE
 EQUIPMENT AND APPLIANCE MANUFACTURER. ALSO PROVIDE
 DETAILS WITH ACCOMPANYING WIND LOAD CALCULATIONS
 SHOWING HOW APPLIANCES AND EQUIPMENT ARE TO BE ATTACHED
 TO THE BUILDING STRUCTURE FOR BUILDING PLAN REVIEW IN
 ACCORDANCE WITH THIS SECTION.
  
 57. GENERAL: HOISTWAYS OF ELEVATORS PENETRATING MORE
 THAN THREE STORIES SHALL BE PROVIDED WITH A MEANS FOR
 VENTING SMOKE AND HOT GASES TO THE OUTER AIR IN CASE OF
 FIRE IN ACCORDANCE WITH FBCB 3004.1. HOISTWAY VENTS
 SHALL BE INSTALLED IN ACCORDANCE WITH FBCB 3004.2
 THROUGH 3004.4. ALSO, STAIR AND ELEVATOR SHAFT VENTS
 SHALL BE EQUIPPED WITH MOTORIZED DAMPERS THAT ARE
 CAPABLE OF BEING AUTOMATICALLY CLOSED DURING NORMAL
 BUILDING OPERATION AND ARE INTERLOCKED TO OPEN AS
 REQUIRED BY FIRE AND SMOKE DETECTION SYSTEMS IN
 ACCORDANCE WITH FBCB 13-409.1.ABC.3.1.
  
 58. ENERGY CALCULATIONS: THE INPUT DATA SHOWS 99 HEAT
 PUMPS GROUPED INTO ONE ENTRY. AN EFFICIENCY RATING OF
 12.8 IS ASSIGNED TO ALL 99 HEAT PUMPS BUT THE EQUIPMENT
 SCHEDULE ON AC-28 INDICATES THAT THE HEAT PUMPS ARE OF
 VARYING EFFICIENCIES. DEMONSTRATE EFFICIENCIES IN THE
 CALCULATIONS WHICH ACCURATELY REFLECT THOSE OF THE
 EQUIPMENT BEING SPECIFIED ON THE PLANS IN ACCORDANCE
 WITH FBCB 13-103.2.
  
 NOTE: PLEASE RESPOND TO EACH COMMENT IN WRITING. ALSO
 PLEASE RETURN ONE SET OF OLD/VOIDED PLANS, PREFERABLY
 THE SET WHICH WAS MARKED UP DURING THIS REVIEW, IN
 ORDER TO ASSIST IN A TIMELY REVIEW OF THE RESUBMITTED
 PLANS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-03-04 Cont ID  
Sent By kstevens Date 2008-03-04 Time 08:42 Rev Time 0.00
Received By kstevens Date 2007-12-22 Time 16:59 Sent To  
Notes
2008-03-04 18:56:58DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 FUEL GAS
 FBC-2004 BUILDING
 FBC-2004 CHAPTER 11
 FBC-2004 CHAPTER 1
 FHA-98 DESIGN MANUAL
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
 CITY WPB MUNICIPAL CODE
  
 1. SURVEY SHEET THE ADDRESS FOR WALLACE SURVEYING #4569
 DOES NOT REFLECT THE STATE OF FLORIDA DBPR ADDRESS OF
 RECORD. PLEASE UPDATE THE TITLE BLOCKS OR THE DBPR
 WEBSITE PRIOR TO RESUBMITTING. FAC 61G16.004(1) & FS
 481.306.
  
 2. IRRIGATION PLANS & PERMIT REQUIRED. SECTION
 106.3.5.1.3(9).
  
 3. THE ADDRESS ON THE PLANS AND THE BINDER ARE
 DIFFERENT. 2501 N FLAGLER AND 2500 PONCE DE LEON AVE.
 PLEASE CORRELATE. FAC 61G1-16.004(3) & FS 481.2055.
  
 4. SHT G-0.03 APPLICABLE CODE TO INCLUDE FHA-98 DESIGN
 MANUAL.
  
 5. SHTS A-2.52 & A-2.53 DRAINS AROUND THE POOL ARE
 INDICATED AS FLOOR DRAINS. IF THEY ARE FOR DRAINING THE
 STORM WATER OFF THE DECK THEY SHOULD BE INDICATED AS
 DECK DRAINS.--ALSO SEE FLOOR DRAINS AT THE "TH
 UNITS". PLEASE CLARIFY WHAT IS BEING DRAIND. THEY
 APPEAR TO BE ROOF DRAINS AT THE SPA. SECTIONS 106.1.1
 106.2.1, TABLES 710.1(1), 710.1(2) & 1106.3.
  
 6. SUBMIT CALCULATION FOR MINIMUM FACILITIES FOR THE
 COMMON AREAS, FITNESS, RECREATION, SOCIAL BAR, SOCIAL
 /LOUNGE OFFICE ETC. TABLES 1004.1.2 & 403.1.
  
 7. SHT A-2.6.2 NO SECONDARY ROOF DRAINS/EOS SHOWN AT
 STAIR #9. SECTION 1107.
  
 8. SHT A-2.6.3 NO SECONDARY ROOF DRAINS/EOS SHOWN AT
 STAIR #7. SECTION 1107.
  
 9. SHTS A-3.10 THRU A-3.53 SHOW COMPLIANCE WITH
 REQUIREMENTS 6 & 7 FOR EACH UNIT, OR SHOW COMPLIANCE
 FOR A TYPICAL UNIT OF EACH TYPE. SHOW THE WATER CLOSET
 AT 18" OFF THE WALL TO THE CENTERLINE OF THEFIXTURE
 WHERE APPLICABLE, (PAGE 6.3) & SHOW A MINIMUM 33"
 OPENING FOR THE WATER CLOSETS. INDICATE 18" & 15" FROM
 THE CENTERLINE OF THE FIXTURE TO ADJACENT FIXTURES WHEN
 NOT NEXT TO A WALL. (PAGE 6.7). FHA-98 DESIGN MANUAL.
 --SEE PAGE 6.10 FOR REINFORCING AT NON CONVENTIONAL
 BATHTUBS. IF THIS TYPE OF TUB IS TO BE ADAPTABLE PLEASE
 SHOW THE BACKING.
  
 10. SHTS A-3.10 THRU A-3.53 SHOW CLEAR FLOOR SPACE IN
 THE KITCHEN AS REQUIRED ON PAGES 7.3 & 7.4 FHA-98
 HOUSING MANUAL.--SHOW MINIMUM CLEARANCE DIMENSION
 BETWEEN REFRIG, RANGE & BASE CABINETS AS REQUIRED ON
 PAGES 7.7 & 7.8 FHA-98 DESIGN MANUAL.--SHOW TURNING
 IN THE "U" SHAPED KITCHENS THAT HAVE A SINK, RANGE OR
 COOKTOP AT ITS BASEAS REQUIRED ON PAGE 7.9 OR SEE
 EXCEPTION ON PAGE 7.11. INDICATE ON PLANS IF EXCEPTION
 WILL BE USED AND SUBMIT A DETAIL FOR EXCEPTION.
  
 11. SHTS A-3.10 THRU A-3.53 INDICATE ON PLANS WHICH
 SPECIFICATION, "A" OR "B" TO BE USED FOR EACH UNIT AS
 REQUIRED ON PAGES 7.34 & 7.35. SEE REQUIREMENTS FOR
 EACH.--SHOW THE CLEAR FLOOR SPACE, (SUPERIMPOSED
 ON THE FLOOR PLANS), FOR THE ACCESSIBLE FIXTURES FOR
 EACH UNIT. SEE PAGES 7.43 THRU 7.57.
  
 12. SHT A-3.16 SHOW THE CLEAR FLOOR SPACE FOR THE
 ACCESSIBLE FIXTURES IN THE MEN'S AND WOMEN'S LOCKER
 ROOMS. SHOW THE TURNING AREA. SHOW THE CLEAR FLOOR
 SPACE FOR THE ACCESSIBLE DRINKING FOUNTAIN. SHOW THE
 ACCESSIBLE W/C'S TO BE 18" OFF THE WALL TO THE
 CENTERLINE OF THE FIXTURE AND THE LAV TO BE A MINIMUM
 15" OFF THE WALL TO THE CENTERLINE OF THE FIXTURE.
 SECTIONS 11-4.16.2, 11-4.18.3, 11-4.19.3, 11-4.21.2
 11-4.22.3 & FIGURE 28 AS WELL AS SECTION 11-4.15.5 FOR
 THE DRINKING FOUNTAIN.
  
 13 SHT A3.1.6 ACCESSIBLE STALLS SHALL COMPLY WITH
 FIGURE 30(E), FLUSH CONTROLS FOR WATER CLOSETS SHALL
 COMPLY WITH SECTION 11-4.16.5. LAVS SHALL COMPLY WITH
 SECTIONS 11-4.19.4 EXPOSED PIPES AND SURFACES AS WELL
 AS 11-4.19.5 FAUCETS. PLEASE SUBMIT DETAILS.
  
 14. SUBMIT A DETAIL FOR THE ACCESSIBLE DRINKING
 FOUNTAIN SHOWING COMPLIANCE WITH SECTION 11-4.15 WITH
 ALL SUBSECTIONS AS WELL AS SECTION 11-4.1.3(10)(A).
  
 15. SHT A-3.28 MEN'S AND WOMEN'S TOILET ROOMS. SHOW THE
 CLEAR FLOOR SPACE FOR ACCESSIBLE FIXTURES PER SECTIONS
 11-4.16.2 & 11-4.19.3.
  
 16. SHT A-3-31 SHOW W/C'S TO BE 18" OFF THE WALL AND
 THE LAVS MINIMUM 15" OFF THE WALL. FIG 28.--STALLS
 TO COMPLY WITH FIG. 11-30(E).
  
 17. SHT A-3.31 MORE INFORMATION REQUIRED. WILL THERE BE
 COOKING IN THE CATERING KITCHEN? SECTION 106.1.2.
  
 18. SHTS A-7.04 & A-7.05 FINISH SCHEDULE FOR COMMON
 AREAS. PLEASE INDICATE WHERE THE LEGEND FOR THE FINISH
 TYPES CAN BE LOCATED. REMARKS STATE "REFER TO ID.
 DRAWINGS". PLEASE INDICATE THE SHEET NUMBER FOR ID
 DRAWINGS. SECTION 106.1.2.
  
 19. SUBMIT CALCULATIONS FOR PRIMARY AND SECONDARY ROOF
 & DECK DRAINS FOR THE ROOF, GROUND FLOOR DECK AND
 SECOND FLOOR. SHOW SECONDARY DRAINS FOR SHEETS P-1.1
 THRU P-1.5 AND SHTS P-2.1 THRU P-2.4. SECTIONS 1106 &
 1107 WITH ALL SUBSECTIONS AND TABLES. SHOW THE AREA
 BEING DRAINED BY EACH ROOF DRAIN, DECK DRAIN AND 1/2
 THE AREA OF ALL VERTICAL WALLS INCLUDING PARAPETS FOR
 EACH DRAIN AFFECTED, AS WELL AS ANY AREA FROM A ROOF
 THAT DRAINS TO THE ROOF/DECK FROM ABOVE IN THE
 CALCULATIONS.
  
 20. SHT P-00 NOTE STATES "2 INCH COLD WATER TO COOLING
 TOWER METER, FOR EXACT LOCATION SEE CIVIL ENGINEERING
 DRAWING" - COOLING TOWER METERWATER NOT SHOWN ON SHEET
 C3. PLEASE CLARIFY. SECTIONS 106.1.2 AND 608.13.2.
  
 21. SHT P-00 IN ONE SET OF PLANS HAS DIFFERENT
 INFORMATION THAN THE SHT P-00 IN THE OTHER SET OF
 PLANS. ALSO THE DATE THAT THE SEAL AND SIGNATURE WERE
 AFFIXED IS DIFFERENT. WHY 2 SHEETS WITH P-00
 DESIGNATIONS? PLEASE CLARIFY. SECTION 106.1.2.
  
 22. SHTS P-001, P-002, P-00, P-01 & P-.2 ARE DRAWN AT
 1/16TH PER FT. SCALE & HAS ALOT OF INFORMATION AND IS
 NOT LEGIBLE AS TO ITS INTENT. BLDG PLANS SHALL BE DRAWN
 TO A MINUMUM 1/8" PER FT SCALE PER SECTION 106.1.3.
  
 23. SHT P-001 DOMESTIC PUMP ROOM A SHUT OFF VALVE IS
 REQUIRED FOR THE LINE TO THE HOSE BIBB. SECTION
 606.2(2).--PIPING IS NOT SHOWN TO MANY DECK DRAINS.
 --SUMP PUMP #11 WAS NOT FOUND.--2 SUMP PUMPS HAVE
 THE # 20 SHOWN. PLEASE CLARIFY--MANY NOTES ON THE
 FLOOR PLAN ARE NOT LEGIBLE. (RISER DESIGNATION NUMBERS
 OVER THE TOP OF NOTES). PLEASE CLARIFY--SHOW ALL
 PIPE SIZES AND RISER DESIGNATIONS FOR STORM RISERS.--
 INDICATE WHERE THE SANITARY PIPE CONTINUES TO WHEN
 INDICATING CONTINUATION OF PIPE. (WHAT SHEET DOES IT
 CONTINUE ON)?--TWO RISER 63 DESIGNATIONS. PLEASE
 CLARIFY--IDENTIFY FIXTURES BEHIND THE ELEVATORS AND
 INDICATE WHICH RISER THE VENT CONNECT TO AT ELEVATORS
 ONE THRU FIVE. SHOW VENT ON RISER. SECTIONS 106.1.1 &
 106.1.2. TABLES 710.1(1), 710.1(2), 916.1, 1106.2 &
 1106.3.
  
 24. SHT P-002 ONE GAS RISER NOT CONNECTED TO GAS MAIN.
 -- SOME GAS RISERS ARE INDICATED AS RISING UP AND
 DROPING DOWN FROM THE LOWER LEVEL GARAGE. ARE THERE GAS
 APPLIANCES BELOW THE LOWER GARAGE? PLEASE CLARIFY.--
 IDENTIFY RISERS AT THE BASE OF THE STACK SO COMMENTS
 CAN BE ADDRESSED TO SPECIFIC RISERS.--SOME NOTES
 ARE NOT LEGIBLE.--INDICATE GAS PIPE SIZES. SECTIONS
 106.1.1, 106.1.2 TABLE 402.4(3).
  
 25 INDICATE THE STORM RISER NUMBERS FOR EACH STORM
 RISER ON EACH SHEET THROUGH OUT THE BUILDING SO THE
 RISERS CAN BE TRACKED. SHEET WILL BE REVIEWED WHEN
 SUBMITTED TO ACCEPTABLE SCALE. SECTION 106.1.3. TABLES
 1106.2 & 1106.3.
  
 26. SHTS P-001 AND P-01 HAVE THE SAME INFORMATION.
 PLEASE CLARIFY. SECTION 106.1.1.
  
 27. SHT P-1.1 SHOWS PIPING TO FIXTURES THAT ARE NOT ON
 THE FLOOR PLAN, EXAMPLE RISER #2. THE SHEET ALSO SHOWS
 FIXTURES WITH NO PIPING INDICATED, EXAMPLE RISER NUMBER
 33. SHOW ALL PIPING TO THE FIXTURES. THE SANT. PIPING
 SHALL BE SHOWN ON THE SAME SHEET AS THE FIXTURES. THE
 STORM PIPING SHALL BE SHOWN ON THE SAME SHEET AS THE
 DECK DRAINS, PLANTER DRAINS ETC. (SEE SHT P-5.2 RISER
 49 AS AN EXAMPLE).--WHAT RISER DOES THE SINK BY
 STAIR 1A CONNECT TO?--SANITARY RISER #4 DOES NOT
 REFLECT THE FLOOR PLAN.--IDENTIFY THE PIPE BY RISER
 115 NOT SHOWN ON THE RISER.--INDICATE RISER NUMBERS
 FOR W/M'S BEHIND ELEVATORS 1, 2 & 3 AS WELL AS THE
 W/M'S BEHIND STAIR #2 & STAIR #3.--EXPLAIN THE
 NUMBER 5 IN THE RECTANGLE BY THE HOSE BIBB NEAR COL.
 LINE 3/D. SECTIONS 106.1.1 & 106.1.2. TABLE 1106.3.
  
 28. SHTS P-1.2, P-1.3, P-1.4, P-1.5, P-2.1, P-2.2,
 P-2.3, P-2.4, P-3.1, P-3.4, P-4.1, P-4.2, P-4.3, P-4.4,
 P-5.1, P-5.4, P-6.1, P-6.2, P-7.1 & P-7.2SHOW PIPING
 TO FIXTURES, DECK DRAINS & PLANTER DRAINS ON THE SHEET
 THAT THE FIXTURES, DECK DRAIN & PLANTER DRAINS ARE
 LOCATED. SEE SHT P-2.3 RECREATION REST ROOM OR SHT
 P-3.3 SOCIAL ROOM BATHROOM AS EXAMPLES OF CORRECT
 INFORMATION. SECTIONS 106.1.1 & 106.1.3.
  
 29. SHT P-1.2 IDENTIFY THE RISER NUMBERS FOR W/M'S
 BEHINDSTAIR NUMBER 4, STAIR NUMBER 5 AS WELL AS
 ELEVATORS NUMBERS 4, 5 & 6.--2 RISERS NUMBERED 63.
 PLEASE CLARIFY. SECTIONS 106.1.1 & 106.1.2 & TALBES
 710.1(1), 710.1(2).
  
 30. SHT P1.3 THE OVERFLOW FROM THE FOUNTAIN SHALL DRAIN
 TO THE STORM, NOT SANITARY AS SHOWN. (NOTE #3). --
 WATER RISER 18 & CONDENSATE 17 IN THE SAME UNIT? SEE
 WATER RISER 17 & CONDENSATE 18ALSO.-- RECREATION
 BATHROOM SHOWS 1/2" COLD WATER SUPPLY TO THE BATHROOM
 THEN INCREASES TO 1-1/4". WATER ALSO SHOWS 2" SUPPLY
 DROPS BETWEEN THE SHOWERS. PLEASE CLARIFY. SECTIONS
 106.1.1 & 106.1.2. TABLE 604.5.--SHOW RISER
 DESIGNATION NUMBERS FOR RISER 76, 77, 79 & 80 AS WELL
 AS RISERS 81, 82 & 87.--SHUT OFF VALVE IS REQUIRED
 ON THE SUPPLY LINE TO THE HOSE BIBB IN THE FOUNTAIN
 EQUIPMENT ROOM.SECTIONS 106.1.1, 106.1.2 & 606.2(2).
  
 31. SHTS P2.1 THRU P2.4 SHOW THE SANITARY PIPING TO
 EACH FIXTURE THAT REFLECTS THE FLOOR PLAN. SECTION
 106.1.1, 106.1.2 & 106.3.5.1.3.
  
 32. SHT P-4.1 BRANCH LINE TO KITCHEN SINK MISSING FOR
 RISER #34. SECTION 106.1.1, 106.1.2 & TABLE 709.1.
  
 33. SHT P-4.2 BRANCH LINE TO KITCHEN SINK MISSING FOR
 RISER #34. SECTION 106.1.1, 106.1.2 & TABLE 709.1.
  
 34. SHT P-4.4 SHOWS TWO 2" LINES TO THE COOLING TOWER.
 ARE THERE TWO COOLING TOWERS? PLEASE CLARIFY. SECTION
 106.1.2.
  
 35. SHT P-5.2 INDICATE WHERE THE 1/4" SCALE TO THE
 TOILET ROOMS CAN BE LOCATED AS REFERENCED. INFORMATION
 AT THE RIGHT SIDE OF THE FLOOR PLAN IN NOT COMPLETE.
 PLEASE SHOW ALL INFORMATION INTENDED. SECTIONS 106.1.1
 & 106.1.2.
  
 36. SHT P-5.3 VENT 87 IS NOT SHOWN AND VENT 91A
 INDICATED IS NOT SHOWN ON THE LOWER LEVELS. PLEASE
 CORRELATE. SECTION 106.1.1 & TABLE 916.1.
  
 37. SHT P-5.4 VENTS 105 & 107 ARE SHOWN CONNECTING TO
 THE EAST VENT ON SHT P-4.4. PLEASE CLARIFY.--
 COOLING TOWER WATER SUPPLY PIPING DOES NOT REFLECT THE
 FLOOR PLAN AS THE HOSE BIBB IS MISSING. PLEASE
 CORRELATE. SECTION 106.1.1 & TABLE 916.1.
  
 38. SHT P-6.2 SHOW THE VTR FOR RISERS 70 & 71. SECTIONS
 106.1.1 & 903.3.
  
 39. SHT P-7.1 INDICATE THE RISER NUMBER FOR THE 7TH
 FLOOR TOILET ROOMS SANITARY. SECTION 106.1.1 & TABLES
 710.1(1) & 710.1(2).
  
 40. SHT P-7.2 UNABLE TO REVIEW INFORMATION ON THE NORTH
 END, (LEFT SIDE),OF SHEET WITHOUT TAKING PLANS APART.
 SECTION 106.1.3. PLEASE SEE THAT ALL INFORMATION IS
 AVAILABLE FOR REVIEW.--SHOW ALL RISER NUMBERS AT
 THE TOILET ROOMS. SECTIONS 106.1.1 106.1.2 & TABLES
 710.1(1) & 710.1(2).
  
 41. SHT P-8 LINE TO THE ICE MAKER NOT SHOWN ON THE
 FLOOR PLAN FOR BOTH A UNITS. PLEASE CORRELATE. SECTION
 106.1.1.
  
 42. SHT P-9 UNIT "B" FLOOR PLAN DOES NOT SHOW THE WATER
 LINE TO THE ICE MAKER TO REFLECT THE ISO. RISER
 DIAGRAM. PLEASE CORRELATE. SECTION 106.1.1.--UNIT
 "B" GROUND FLOOR PLAN SHOWS THE WATER LINE TO THE ICE
 MAKER UNDER THE SLAB ON THE FLOOR PLAN, BUT NOT ON THE
 ISOMETRIC RISER DIAGRAM. PLEASE CORRELATE. SECTION
 106.1.1.
  
 43. SHT P-10 UNIT"C" WATER RISER DOES NOT REFLECT THE
 FLOOR PLAN WHERE THE WASH MACHINE CONNECTS TO THE
 HOT/COLD WATER MAIN. PLEASE CORRELATE. SECTIONS 106.1.1
 & 604.
  
 44. SHT P-11 UNIT "B" FLOOR PLAN DOES NOT SHOW THE
 WATER LINE TO THE ICE MAKER TO REFLECT THE ISOMETRIC
 RISER DIAGRAM.--UNIT "B" GROUND FLOOR PLAN
 INDICATES THE ICE MAKER SUPPLY LINE IN THE SLAB, BUT
 THE RISER DIAGRAM SHOWS THE ICE MAKER LINE IN THE WALL.
 CORRELATE. SECTION 106.1.1.
  
 45. SHT P-12 UNIT "C" WATER RISER DIAGRAM DOES NOT
 REFLECT THE FLOOR PLAN WHERE THE WASH MACHINE CONNECTS
 TO THE WATER MAIN. PLEASE CORRELATE. SECTIONS 106.1.1 &
 604.
  
 46. SECOND SHT P-11 UNIT "C" DOUBLE RISER DIAGRAM
 MISLABELED A LAV FOR A TUB & A LAV FOR A BIDET AND DOES
 NOT REFLECT THE PIPING AT THE TUB/LAV IN THE MASTER
 BATH.--PIPING AT THE TUB & LAV DOES NOT REFLECT THE
 FLOOR PLAN.--TUB INDICATED AS LAV IN TUB BATH BY
 WASH MACHINE.PLEASE CORRELATE. SECTION 106.1.1 &
 TABLE 709.1.
  
 47. SECOND SHT P-12 INDICATES UNIT "CH" MOD. 1& 2
 FIRST, SECOND & THIRD FLOORS, BUT THE RISER DIAGRAM IS
 FOR MOD. 3. PLEASE CLARIFY. SECTION 106.1.1.
  
 48. THE SEQUENCE OF SHEETS SUBMITTED IS AS FOLLOWS:
 P-11, P-12, P-11, P-12, P-13, P-14 & P-15. PLEASE
 NUMBER SHEETS IN A SEQUENCE THAT CAN BE LOGICALLY
 FOLLOWED. SECTIONS 106.1.3 & 106.1.3.
  
 49. SHT P-15 SHOWS THE SAME INFORMATION THAT SHEET P-13
 SHOWS. PLEASE CLARIFY. SECTIONS 106.1.1 & 106.1.3.
  
 50. SHT P-14 UNITS "E" FLOOR PLANS & "E" GROUND FLOOR
 PLANS DO NOT SHOW THE WATER LINES TO THE ICE MAKERS
 THAT REFLECT THE FLOOR PLAN. PLEASE CORRELATE.--
 UNIT "E" GROUND FLOOR PLAN SHOWS HOT & COLD WATER
 SUPPLY TO THE WATER CLOSET IN THE 2ND BATHROOM. PLEASE
 CORRELATE. SECTIONS 106.1.1 & 601.1.
  
 51. SECOND SHT P-15 UNIT "F" FLOOR PLAN DOES NOT SHOW
 THE WATER LINE TO THE ICE MAKER THAT REFLECTS THE RISER
 DIAGRAM.--UNIT "F" GROUND FLOOR PLAN WATER RISER
 DIAGRAM DOES NOT REFLECT THE FLOOR PLAN AT THE 2ND
 BATHROOM. PLEASE CORRELATE. SECTIONS 106.1.1 & 601.1.
  
 52. SHT P-16 UNIT H FLOOR PLAN. PLEASE SHOW PIPING TO
 THE HOSE BIBB TO REFLECT THE RISER DIAGRAM. SECTIONS
 106.1.1 601.1.
  
 53. SHT P-17 ALL "J" UNITS THE WATER RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN AT THE WATER LINES TO THE
 ICE MAKERS.--UNIT "J" GROUND WATER RISER DIAGRAM
 DOES NOT REFLECT THE FLOOR PLAN AT THE WASH MACHINE.
 --UNIT "J" FLOOR PLAN SHALL REFLECT THE RISER
 DIAGRAM. NO HOSE BIBB LINE SHOWN, NO ICE MAKER LINE
 SHOWN.--NO UNIT "J" GROUND MOD 2 FLOOR PLAN
 SUBMITTED.PLEASE CORRELATE. SECTIONS 106.1.1 &
 601.1.
  
 54. SHT P-19 UNIT "R" RISER DIAGRAM DOES NOT REFLECT
 THE FLOOR PLAN AT THE WATER LINE TO THE ICE MAKER.--
 UNIT "P" WATER RISER DIAGRAM DOES NOT REFLECT THE FLOOR
 PLAN AT THE WATER LINE TO THE ICE MAKER, AND WHERE THE
 SHOWER IN THE MASTER BATH CONNECTS TO THE MAIN & OFFSET
 BY THE REFR.--UNIT "U" REV WATER RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN WHERE THE COLD & HOT RISERS
 CONNECT TO THE WATER MAIN. PLEASE CORRELATE. SECTIONS
 106.1.1 & 6011.1.
  
 55. SHT P-20 UNIT "TH" MOD REV 3RD FLOOR PLAN DOES NOT
 SHOW THE WATER PIPING TO THE MASTER BATH THAT REFLECTS
 THE RISER DIAGRAM.--UNIT "TH" R MOD 1 & MOD WATER
 RISER DIAGRAM DOES NOT REFLECT THE FLOOR PLAN WHERE THE
 RISER TO THE 5TH FLOOR POWDER ROOM CONNECTS AT THE 4TH
 FLOOR. LAV SHOULD BE ON THE OTHER SIDE OF THE RISER 4TH
 FLOOR. PLEASE CORRELATE. SECTIONS 106.1.1 & 601.1.
  
 56. SHT P-21 UNITS "TH" & "TH" REV WATER RISER DIAGRAM
 DO NOT REFLECT THE FLOOR PLANS AT THE 4TH FLOOR. RISER
 IS SHOWN BEHIND THE W/C NOT TO THE LEFT SIDE OF THE LAV
 AS INDICATED ON THE RISER DIAGRAM.--UNITS "TH" &
 "TH" REV FLOOR PLANS DO NOT SHOW THE WATER PIPING TO
 THE MASTER BATH. PLEASE SHOW ALL PIPING. SECTIONS
 106.1.1 & 601.1.
  
 57. SHT P-22WATER RISERS 1 THRU 14 INDICATE WHERE THE
 CONTINUATION OF RISER CAN BE FOUND TO REFLECT THE
 PIPING ON THE 7TH FLOOR. ALSO THE OFFSETS SHOWN ON THE
 6TH FLOOR FOR ALL RISERS BUT RISER 14IS NOT SHOWN ON
 THE RISER DIAGRAMS.--RISERS 4, 6, 8 & 10 INDICATE
 1" HW (TYP) BUT SHOW 34" BELOW.--RISERS 5. 7. 9 &
 11SHOWS 3/4 HW FROM THE COLD WATER RISER AT THE 7TH
 FLOOR.--RISER 13 SHOWS 3/4" HW (TYP) BUT SHOW 1"
 BELOW.--RECREATION MEN'S BATHROOM DOES NOT REFLECT
 THE FLOOR PLAN AT THE LAV/URINAL.--PLEASE CLARIFY
 1/2" DESIGNATIONS BY THE SHOWERS. PLEASE CORRELATE.
 SECTIONS 106.1.1 & 601.1.
  
 58. SHT P-23 INDICATE THE LOCATION OF THE WATER RISERS
 1C THRU 7C AND WATER RISERS 1T THRU 15T. UNABLE TO
 LOCATE.--UNABLE TO READ/REVIEW INFORMATION AT THE
 FAR LEFT SIDE OF THE SHEET WITHOUT TAKING THE PLANS
 APART. PLEASE MAKE ALL INFORMATION AVAILABLE.--PIPE
 SIZING AT THE GANG TOILETS SUPPLY, (1-1/2") DOES NOT
 REFLECT THE FLOOR PLAN, (2"). SECTIONS 106.1.1, 106.1.2
 & 601.1.
  
 59. SHT P-24 RISERS 2, 4 & 6 DO NOT REFLECT THE FLOOR
 PLAN AT THE GROUND FLOOR.--RISER 11 DOES NOT
 REFLECT THE FLOOR PLAN.--RISER 16CLEANOUTS ARE
 REQUIRED ON THE VENT PRIOR TO CONNECTING TO THE VENT
 STACK ON ISLAND VENTS. SECTION 913.3 (SEE FIG. 913.2).
 --RISER 19 SHOWS A SHOWER ON THE FIRST FLOOR BUT THE
 FLOOR PLAN SHOWS A TUB.--RISERS 20, 29, 38 & 47 DO
 NOT REFLECT THE FLOOR PLAN AT THE 5TH FLOOR. --RISERS
 21, 30, 39 & 48 THREE INCH PIPE REQUIRED ON THE BRANCH
 LINE TO THE WASH MACHINES. SECTION 406.3.--RISERS
 23, 32 & 41 DO NOT REFLECT THE FLOOR PLAN AT THE 5TH
 FLOOR.PLEASE CORRLEATE. SECTIONS 106.1.1, 701.1 &
 TABLES 710.1(1), 710.1(2).
  
 60. SHT P-25 RISERS 25, 34 & 43 CLEANOUTS ARE REQUIRED
 ON THE VENT PRIOR TO CONNECTING TO THE VENT STACK ON
 ISLAND VENTS. SECTION 913.3 (SEE FIG. 913.2). RISERS
 SHOW SHOWERS ON THE 6TH FLOOR, BUT FLOOR PLAN SHOWS
 TUBS.--RISERS 28, 37, 46 DO NOT REFLECT THE FLOOR
 PLAN. RISER SHOWS SHOWERS 1ST FLOOR BUT FLOOR PLAN
 SHOWS TUBS.--RISER 55 DOES NOT REFLECT THE FLOOR
 PLAN 1ST FLOOR. FLOOR PLAN SHOWS TUB/SHOWER IN BOTH
 BATHROOMS.--RISERS 52 & 65 CLEANOUTS ARE REQUIRED
 ON THE VENT PRIOR TO CONNECTING TO THE VENT STACK ON
 ISLAND VENTS. SECTION 913.3 (SEE FIG. 913.2).--
 RISER 52 DOES NOT REFLECT THE FLOOR PLAN AT THE 5TH &
 6TH FLOORS.--RISERS 67 & 68 DO NOT REFLECT THE
 FLOOR PLAN AT THE 2ND FLOOR FOR RISER 68 AND FOR THE
 OFFSET ABOVE THE FIRST FLOOR ON RISER 67 PLUS RISER 67
 SHOWS TUBS BUT THE FLOOR PLAN SHOWS SHOWERS.--
 RISER 70 TOILET ROOM 4TH FLOORWILL REVIEW FOR CODE
 COMPLIANCE WHEN 1/4" FLOOR PLAN IS FOUND. (SEE NOTE
 P-5.2).--BOILER ROOM DETAIL SHOWS A FLOOR DRAIN FOR
 INDIRECT WASTE. FLOOR DRAINS ARE NOT APPROVED WASTE
 RECEPTORS. A FLOOR SINK OR HUB DRAIN WILL BE REQUIRED
 PER SECTIONS 802.3 & 802.3.2. ALSO THE INDIRECT WASTE
 SHALL BE LOCATED TO NOT BECOME A TRIPPING HAZARD.
 PLEASE CORRELATE.SECTIONS 106.1.1, 701.1 & TABLES
 710.1(1), 710.1(2).
  
 61. SHT P-26. RISER 18 INDICATES NOTE TWO WHICH STATES
 "FOR CONTINUATION REFER TO VENTILATION PIPING. SEE
 HORIZONTAL DIAGRAM ON SHT P-28". SHT P-28 AS SUBMITTED
 IS STORM RISERS. PLEASE CLARIFY. SECTION 106.1.1--
 RISER 114 DOES NOT REFLECT THE FLOOR PLAN AT THE 5TH
 LEVEL. (DRINKING FOUNTAINS NOT SHOWN).--ALL "C" AND
 "T" RISERS HAVE NOT BEEN REVIEWED AT THIS TIME BECAUSE
 THE PIPING ON THE FLOOR PLANS IS NOT SHOWN ON THE FLOOR
 WITH THE FIXTURES AND IS VERY HARD TO FOLLOW. PUT
 PUPING ON THE FLOOR PLAN WITH THE FIXTURES. (SEE POOL
 BATH PIPING LAYOUT ON SHT P-5.1 AS AN EXAMPLE).
 SECTIONS 106.1.1 &701.1. TABLES 710.1(1) & 710.1(2).
  
 62. SHTS P-24, P-25 & P-26 INDICATE THE TOTAL DFU'S AND
 TOTAL DEVELOPED LENGTH FOR COMBINED VENTS SUCH AS
 RISERS 1 THRU 5, RISERS 6 THRU 13, RISERS 14 THRU 19
 ETC. TABLE 916.1.
  
 63. SHT P-27A DOES NOT REFLECT THE FLOOR PLAN AT RISERS
 89, 93 & 94.--TWO RISERS NUMBERED 63. (ALSO SEE SHT
 P-001) PLEASE CORRELATE/CLARIFY SECTIONS 106.1.1 &
 701.1.
  
 64. SUBMIT MANUF SPECIFICATION FOR THE SUMP PUMPS. SHOW
 LISTING. (SEE SHT P-30). SECTION 303.4.
  
 65. SHT P-27B RISER DIAGRAM INDICATES 5 SUMP PUMPS.
 MORE INFORMATION IS REQUIRED. PLEASE INDICATE WHAT
 LEVEL THESE SUMP PUMPS ARE LOCATED, INDICATE WHAT WILL
 BE PUMPED OUT AND SHOW COMPLIANCE WITH SECTION 712.2.
 IS THERE A LEVEL LOWER THAN THE LOWER GARAGE? PLEASE
 CLARIFY. SECTION 106.1.2.--RISER DOES NOT REFLECT
 THE FLOOR PLAN AT RISERS 1T, 2T, C8, C10, 27T, 25T,
 C12, 29T & CT1. PLEASE CORRELATE. SECTIONS 106.1.1 &
 701.1.
  
 66. SHT P28 MOST INFORMATION IS NOT LEGIBLE WITHOUT THE
 AID OF A MAGNIFYING GLASS. SECTIONS 106.1.1 & 106.1.2.
 PLEASE SUBMIT INFORMATION THAT IS OF SUFFICIENT
 CLAIRTY.
  
 67. SHTS P28A THRU P-28D. INDICATE THE RISER NUMBERS SO
 THE RISERS CAN BE TRACKED THRU THE BUILDING. INDICATE
 WHERE THE RISER CONTINUES THAT IS NOT SHOWN ON THE
 SHEET. SOME OF THE INFORMATION CONTINUES AT THE TOP OF
 THE SHEET, SOME TO THE SIDE, AND SOME INFORMATION
 CONTINUES AT THE BOTTOM OF THE SHEET BUT DOES NOT
 INDICATE WHERE THE CONTINUED PIPE CAN BE LOCATED.
 UNABLE TO TRACK THE PIPING TO VERIFY PIPE SIZE OR
 SQUARE FOOTAGE BEING DRAINED. SECTIONS 106.1.1, 106.1.2
 & 1101.1. ALSO TABLES 1106.2 & 1106.3.
  
 68. SHT P-28E INDICATE RISER NUMBER RISER TO TRACK THE
 RISER THRU THE BUILDING AND TO VERIFY PIPE SIZE AND
 SQUARE FOOTAGE BEING DRAINED.--CLARIFY CONNECTION
 THAT INDICATES 12"-1970, 12"-25610, 1-1/4" CD & 1-1/2"
 CD.--CONDENSATE TO DRAIN SEPARATELY FROM THE
 BUILDING.--NUMEROUS PIPE SIZES THAT ARE NOT
 INDICATING WHAT THEY ARE ASSOCIATED WITH. PLEASE
 CLARIFY. SECTIONS 106.1.1, 106.1.2 & 1101.1. ALSO TABLE
 1106.3.
  
 69. SHT P-28F HORIZONTAL GARAGE PIPING ISOMETRIC
 DIAGRAM DOES NOT REFLECT THE FLOOR PLAN TO THE 4"
 TRENCH DRAINS/SUMP PUMPS 21 & 22. PLEASE CORRELATE.
 SECTIONS 106.1.1 & 1101.1.
  
 70. SHT P-29 THE FOLLOWING INFORMATION IS REQUIRED FOR
 THE SEPARATE GAS PERMIT:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE. - THE ISOMETRIC RISER DIAGRAM SUBMITTED
 DOES NOT SHOW ALL LENGTHS OF PIPE, ALL SECTIONS OF
 PIPE, ALL RISERS AND DOES NOT REFLECT THE FLOOR PLAN.
 SOME BRANCH LINES DO NOT IDENTIFY THE APPLIANCES
 CONNECTING TO THE BRANCH LINE. DELETE ALL UNIONS FROM
 THE FUTURE LINES IN THE KITCHENS. FOR ALL FUTURE
 APPLIANCES, A SHUT OFF VALVE, A NIPPLE AND A CAP ARE
 REQUIRED.
  
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED. - NOT ALL PIPE
 SIZES SHOWN.
  
 C. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2004 FUEL GAS CODE SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU
 402.4(33). - NOT ALL BTU LOADS ARE INDICATED.
  
 D. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4). - TO BE VERIFIED WHEN
 COMMENT "A" IS ADDRESSED.
  
 E. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2004 FUEL
 GAS CODE SECTION 304.
  
 F. SUBMIT A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE AND TERMINATION OF THE
 GAS VENTS PER FBC-2004 FUEL GAS CODE
 SECS. 502 THRU 505.
  
 G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2.
  
 H. SHOW ALL CUT SECTIONS AND CORRESPONDING LENGTHS AS
 WELL AS THE TOTAL DEVELOPED LENGTH DOWNSTREAM OF EACH
 REGULATOR.
  
 I. RISER DOES IT MEET CODE REQUIREMENTS. REGULATORS ARE
 REQUIRED AT ALL FIXTURES OR GROUP OF FIXTURES. MANY
 INDIVIDUAL FIXTURES FIXTURES SHOW NO REGULATORS. A SHUT
 OFF VALVE IS REQUIRED UPSTREAM OF EACH REGULATOR WITH A
 UNION DOWNSTREAM OF EACH SHUT OFF VALVE. SECTION
 409.4.
  
 J. NOTE ON SHT P-29 INDICATES "3/4 INCH GAS UP & DOWN"
 PLEASE CLARIFY DOWN TO WHERE? SECTION 106.1.1.
  
 K.RISER DOES NOT REFLECT THE FLOOR PLAN. RISERS SHOWN
 FOR THE GAS BBQ GRILL SHOWN ON THE 7TH FLOOR SHOW THE
 FUTURE CONNECTIONS FOR THE KITCHEN OF THE UNITS.
 RISERS FOR THE KITCHEN SHOW THE BBQ GRILLS. PLEASE
 CORRELATE RISERS AND FLOOR PLAN. SECTION 106.1.1 &
 TABLE 402.4(3).
  
 L. SUBMIT MANUF SPECIFICATION SHEETS FOR THE
 REGULATORS. SHEETS SHALL SHOW LISTING AND THE MODEL
 NUMBER OF THE REGULATOR SHALL BE INDICATED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***