Plan Review Details - Permit 07110604
Plan Review Stops For Permit 07110604
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-02-14 Cont ID  
Sent By shill Date 2008-02-14 Time 16:24 Rev Time 0.00
Received By shill Date 2008-02-14 Time 16:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2008-02-12 Cont ID  
Sent By shill Date 2008-02-12 Time 16:32 Rev Time 0.00
Received By shill Date 2008-02-12 Time 16:32 Sent To  
Notes
2008-02-12 17:05:40****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.THE SHUTTER CONNECTION MOUNTING TYPE ON THE
 INSTALLATION SCHEDULE IS TO CORRELATE WITH THE ANCHOR
 CHART ON THE PRODUCT APPROVAL.IT APPEARS THAT YOU ARE
 SPECIFYING WALL MOUNT 1 FOR MOST OPENINGS, BUT THIS
 REQUIRES A CONCRETE SUBSTRATE.YOU AHVE SPECIFIED
 CONC./CBS.DOES THIS MEN CONCRETE ON THE TOP, CBS ON
 THE BOTTOM?WALL MOUNT 1 AND CEILING 5 REQUIRE
 CONCRETE SUBSTRATE.
  
 2.ADDRESSED.
  
 3.ADDRESSED.
  
 4.FROM 1ST REVIEW; YOU HAVE SPECIFIED CONC/CBS.NOTE
 THAT SOME CONNECTION TYPES, SUCH AS WALL MOUNT 1 AND
 WALL MOUNT 2, REQUIRE A CONCRETE SUBSTRATE.THIS IS
 ADVISORY ONLY; I AM ATTEMPTING TO FORESEE ISSUES WHICH
 MAY ARISE ON THE NEXT SUBMITTAL.
 2ND REVIEW; SEE ITEM 1.CONCRETE SUBSTRATE REQUIRED
 FOR WALL MOUNT 1AND CEILING 5.
  
 5.SEE SHEET 9 REGARDING MINIMUM SEPARATION TO GLASS.
 1" DOES NOT APPEAR COMPLIANT; PLEASE REVISE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-01-25 Cont ID  
Sent By shill Date 2008-01-25 Time 09:43 Rev Time 0.00
Received By shill Date 2008-01-25 Time 09:43 Sent To  
Notes
2008-01-25 09:49:28****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.THE SHUTTER CONNECTION MOUNTING TYPE ON THE
 INSTALLATION SCHEDULE IS TO CORRELATE WITH THE ANCHOR
 CHART ON THE PRODUCT APPROVAL. YOU'VE WRITTEN A1 AND B,
 BUT SEE SHEET 10.AN EXAMPLE WOULD BE "WALL MOUNT 1".
 I COULD NOT LOCATE "A1" OR "B" ANYWHERE IN THE PRODUCT
 APPROVAL.
  
 2.PLEASE SEE SHEET 11.A FACTOR OF .83 OR .78 IS TO
 BE APPLIED TO ANCHOR SPACING IF THE EDGE DISTANCE IS
 3".IT DOES NOT APPEAR THAT THIS FACTOR HAS BEEN
 APPLIED.
  
 3.SEE OPENING 7.FOR A DESIGN PRESSURE OF -76.7, YOU
 MUST USE THE 90PSF COLUMN (NOT -75).THIS IS ADVISORY
 ONLY; I CANNOT DETERMINE CODE COMPLIANCE DUE FOR THE
 ANCHOR SPACING SPECIFIED UNTIL ITEM 1 HAS BEEN
 ADDRESSED.
  
 4.YOU HAVE SPECIFIED CONC/CBS.NOTE THAT SOME
 CONNECTION TYPES, SUCH AS WALL MOUNT 1 AND WALL MOUNT
 2, REQUIRE A CONCRETE SUBSTRATE.THIS IS ADVISORY
 ONLY; I AM ATTEMPTING TO FORESEE ISSUES WHICH MAY ARISE
 ON THE NEXT SUBMITTAL.
  
 5.A HOLD WAS PLACED ON ANOTHER PERMIT, 07060349,
 ISSUED TO YOUR COMPANY.A REVISION IS REQUIRED; THIS
 ISSUE HAS BEEN DISCUSSED WITH YOUR COMPANY AND THE
 HOMEOWNER.PLEASE SUBMIT THIS REVISION AT THIS TIME.
 NOTE THAT THIS PERMIT WILL EXPIRE SOON (2/1/08).THIS
 PERMIT WAS NOT REVOKED DUE TO AN AGREEMENT BETWEEN ME
 AND YOUR COMPANY THAT A REVISION WOULD BE SUBMITTED.
 THIS HAS NOT BEEN DONE.ALLOWING THIS PERMIT TO BE
 REVOKED OR TO EXPIRE WILL PUT THIS PERMIT IN THE STATUS
 OF WORK BEING DONE WITHOUT A PERMIT AND MAY BE SUBJECT
 TO DISCIPLINARY ACTION.PLEASE ADDRESS THIS AT THIS
 TIME.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-12-03 Cont ID  
Sent By shill Date 2007-12-03 Time 08:56 Rev Time 0.00
Received By shill Date 2007-12-03 Time 08:56 Sent To  
Notes
2007-12-03 08:56:51****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT
 OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16.
  
 ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED.
  
 ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____6.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3
 ABOVE.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-02-07 Cont ID  
Sent By adarroug Date 2008-02-07 Time 11:14 Rev Time 0.00
Received By adarroug Date 2008-02-07 Time 11:14 Sent To B
Notes
2008-02-07 11:14:47TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-01-15 Cont ID  
Sent By adarroug Date 2008-01-15 Time 11:14 Rev Time 0.00
Received By adarroug Date 2008-01-15 Time 11:14 Sent To B
Notes
2008-01-15 11:14:49TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-12-03 Cont ID  
Sent By shill Date 2007-12-03 Time 08:57 Rev Time 0.00
Received By shill Date 2007-11-27 Time 11:34 Sent To  
Notes
2007-11-27 11:34:49TO "MISC" BOX#1