Plan Review Details - Permit 07110518
Plan Review Stops For Permit 07110518
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-12-03 Cont ID  
Sent By shill Date 2007-12-03 Time 17:09 Rev Time 0.00
Received By shill Date 2007-12-03 Time 17:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-11-20 Cont ID  
Sent By shill Date 2007-11-20 Time 11:50 Rev Time 0.00
Received By shill Date 2007-11-20 Time 11:50 Sent To  
Notes
2007-11-20 11:56:19****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 _XX_1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER
 BARRIER REQUIRED FS553.844(5)(A). PROVIDE
 INFORMATION (PRODUCT APPROVAL OR SPECIFICATIONS) TO
 SHOW HOW YOU WILL COMPLY WITH THIS REQUIREMENT.
  
 INFORMATION IS AVAILABLE AT WWW.BOAF.NET.
  
 PLEASE NOTE THAT AN ADDITIONAL CAP SHEET CAN BE USED TO
 COMPLY WITH THIS REQUIREMENT.FOR THE SYSTEM YOU
 CHOSE, SYSTEM TYPE E, TAMKO MODIFIED OVER WOOD, YOU
 HAVE HIGHLIGHTED TAM-PLY IV AS AN OPTIONAL PLY SHEET.
 EITHER AWAPLAN VERSA-SMOOTH OR AWAPLAN VERSAFLEX CAN BE
 USED AS THE OPTIONAL PLY SHEET AND, AS THEY ARE BOTH
 APPROVED CAP SHEETS, CAN BE USED AS THE SECONDARY WATER
 BARRIER IN LIEU OF TAPING THE DECK OR PROVIDING A FULL
 DECK MODIFIED COVERING.THIS ADDITIONAL CAP SHEET CAN
 BE USED EITHER IN ADDITION TO OR IN LIEU OF THE TAM-PLY
 IV.
  
 WHEN RESUBMITTING, PLEASE SUMMARIZE THE SYSTEM YOU
 PROPOSE BY ITEMIZING EACH PLY, INCLUDING TREATMENT OF
 THE DECK IF YOU CHOOSE ONE OF THOSE OPTIONS AS THE
 SECONDARY WATER BARRIER RATHER THAN AN ADDITIONAL PLY.
 PLEASE CONTACT ME IF YOU NEED ASSISTANCE.
  
 ____2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY;
 MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF
 EACH ROOF TYPE
  
 _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
  
 ____4.)FOR THE FLAT DECK, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS.
  
 _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.THIS IS TO
 BE EITHER WRITTEN ON THE PRODUCT APPROVAL OR SUBMITTED
 ON LETTERHEAD, TWO SETS (NOT WRITTEN ON THE RESUB
 SHEET).
  
 ____ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH
 METHOD OF ATTACHMENT YOU ARE USING.IF YOU SELECT FOAM
 ADHESIVE, PRODUCT APPROVALS REQUIRED FAC9B72.
  
 ____ 7.)SEE PRODUCT LIMITATION #7.CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.
  