Plan Review Stops For Permit 07110478 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-08-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-08-28 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-08-28 |
Time |
10:03 |
Sent To |
|
|
Notes |
2008-08-28 10:03:27 | BUILDING REVISION TO ADD IMPACT RATED EXTERIOR DOOR AND | | NON-IMPACT SH WINDOWS. REVISED SHEETS A1 AND A2 ARE OK | | FOR BUILDING. | | REVISED PRODUCT APPROVALS FOR WINDOWS DOOR AND STORM | | PANELS ARE OK. | | | | PROVISO | | | | SUBMIT 2 COPIES OF AN INSTALLATION SCHEDULE. SPECIFY | | CONNECTION TYPE (A,B,C,D OR E), ANCHOR TYPES, ANCHOR | | SPACING, PANEL SPAN, EDGE DISTANCE, ETC. A COPY OF AN | | INSTALLATION SCHEDULE IS ATTACHED. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-06-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-06-25 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-06-25 |
Time |
10:44 |
Sent To |
E |
|
Notes |
2008-06-25 10:44:45 | 2004 FBC W/2007 REVISIONS | | REVISION TO ADD EXTERIOR DOOR TO ADDITION | | | | DENIED BY BUILDING | | | | 1) THE DRAWINGS ARE REQUIRED TO HAVE A TITLE BLOCK | | CONTAINING ALL OF THE INFORMATION REQUIRED BY FLORIDA | | STATUTES AND FAC 61G15-23.002. | | | | 2) SUBMIT TWO SIGNED, SEALED AND DATED COPIES OF | | REVISED DRAWINGS. FBC 106.1 | | | | 3) IN ADDITION TO THE FLOOR PLANS, SUBMIT TWO SIGNED | | AND SEALED COPIES OF A REVISED ELEVATION SHOWING | | LOCATION OF THE NEW DOOR. FBC R301.2.1 AND DCA RULE | | 9B-72. | | | | 4) IN ADDITION TO THE FLOOR PLANS, SUBMIT TWO SIGNED | | AND SEALED COPIES OF A REVISED ROOF FRAMING PLAN | | SPECIFYING THE LINTEL THAT WILL BE USED ABOVE THE DOOR | | OPENING. FBC R606.8 | | | | 5) THE PRESSURES SPECIFIED ON THE REVISION ARE TOO LOW | | AS THE DOOR APPEARS TO BE LOCATED IN WALL ZONE 5. | | PLEASE CORRECT. FBC R301.2.1 AND FIGURE R301.2(8). | | | | 6) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | THE PRODUCT APPROVALS FOR THE DOOR HAS NOT BEEN | | APPROVED IN WRITING BY THE ENGINEER. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-03-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-03-10 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-03-10 |
Time |
12:46 |
Sent To |
|
|
Notes |
2008-03-10 14:59:10 | BUILDING PROVISO | | | | SUBMIT A LETTER FROM THE DESIGNER OF RECORD APPROVING | | THE PRODUCT APPROVALS REQUIRED BY DCA RULE 9B-72. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-11-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-11-21 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-11-21 |
Time |
16:14 |
Sent To |
E |
|
Notes |
2007-11-21 17:03:24 | 2004 FBC W/2007 REVISIONS | | ADDITION | | | | DENIED BY BUILDING | | | | 1) SUBMIT A COPY OF THE PAID RECEIPT FOR THE COUNTY | | IMPACT FEES.IF NEW SHEETS ARE SUBMITTED FOR THE ONES | | WITH THE IMPACT FEE STAMP, THEY WILL HAVE TO BE | | RESTAMPED OR THE OLD SHEETS WITH THE STAMPS CAN BE | | RESUBMITTED ALONG WITH THE NEW ONES. | | | | 2) THE VALUE OF THE WORK ON THE PERMIT APPLICATION WAS | | TOO LOW. IT HAS BEEN ADJUSTED BASED ON THE ICC BUILDING | | VALUATION DATA. FEES IN THE AMOUNT OF $265.35 WHICH | | INCLUDES RADON FEES ARE DUE. | | | | 3) SHOW COMPLIANCE WITH R807.1 ATTIC ACCESS . | | IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF | | CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED | | TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8 M 2 ) | | AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR | | GREATER. | | THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 | | INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE | | LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE | | LOCATION. A 30-INCH (762 MM) MINIMUM UNOBSTRUCTED | | HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME | | POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3 | | FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS | | LOCATED IN ATTICS. | | | | 4) SPECIFY THE SPACING OF THE VERTICAL WALL | | REINFORCEMENT ON THE PLANS. SEE FBC R609.3. | | | | 5) THE CONCRETE NOTES ON D1 SPECIFY THE WRONG EDITION | | ON ACI 318. CHAPTER 43 OF THE 2004 FBC RESIDENTIAL | | SPECIFIES AC1 318-02. PLEASE CORRECT. | | | | 6) THE CLADDING PRESSURES SPECIFIED UNDER WIND | | INFORMATION ON A1 ARE INCORRECT. SEE FBC TABLE | | R301.2(2) AND USE THE 10 SQFT EFFECTIVE WIND AREA FOR | | WORST CASE. | | | | 7) SOME OF THE ROOF OVERHANG COMPONENT AND CLADDING | | PRESSURES ON A1 ARE NOT CORRECT. PLEASE CORRECT. SEE | | FBC TABLE 1609.6.2.1(3). | | | | 8) PROVIDE A ROOF ZONE DIAGRAM FOR A GABLE ROOF ON A1. | | SEE FBC FIGURE R301.2(8). | | | | 9) THE ENERGY CALCULATION FORM IS INCORRECT. WHEN USING | | THE PRESCRIPTIVE METHOD C, THE INSULATION IS REQUIRED | | TO BE THE MINIMUM SPECIFIED ON THE FORM. THEREFORE, THE | | CONCRETE BLOCK IS REQUIRED TO HAVE R-5 INSULATION. SEE | | FBC 13-600. | | | | 10) FBC 106.3* CITY AMENDMENTSPRODUCT APPROVALS. | | THOSE PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | 11) THE NOA FOR THE TRACO WINDOWS HAS BEEN REVISED BY | | NOA NO. 05-0930.03. | | | | NOTE: IN ORDER TO EXPEDITE PLAN REVIEW PLEASE SUBMIT | | ONE SET OF THE OLD DRAWINGS ALONG WITH THE NEW ONES. | | ALSO SUBMIT BOTH OF THE DRAWINGS THAT HAVE THE COUNTY | | IMPACT FEE STAMP OR THE NEW PLANS WILL HAVE TO BE | | STAMPED BY THE COUNTY. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2008-08-26 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-08-26 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-08-26 |
Time |
11:25 |
Sent To |
B |
|
Notes |
2008-08-26 11:39:38 | NONCOMPLIANT | | REVISION DENIED | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1 | | AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | ALL COMMENTS RELATE TO SHEET A2, UNLESS OTHERWISE | | NOTED. ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS | | OTHERWISE NOTED. | | | | 1} THE PERMIT SET HAD AN EXISTING 200 AMP SERVICE WITH | | A DISCONNECT IN COMPLIANCE WITH 230.70(A)(1), THE NEW | | SERVICE ON THE REVISED PLANS DO NOT COMPLY WITH THAT | | ARTICLE AND INITIATES THE FOLLOWING COMMENTS. | | | | 2} DUE TO THE PANEL LOCATION, A DISCONNECT IS REQUIRED | | PER 230.70, 225.32. INDICATE LOCATION ON PLAN PER | | 230.72(A)(1) | | | | 3} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT | | CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE | | EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS | | EQUAL TO OR GREATER THAN THE AVAILABLE FAULT. | | | | 4} PROVIDE A SITE PLAN INDICATING THE LOCATION OF ALL | | SERVICE EQUIPMENT SO THAT COMPLIANCE WITH ARTICLE 230 | | CAN BE REVIEWED. | | | | 5} RECEPTACLE SPACING MUST COMPLY WITH 210.52(A)(1) AND | | 210.52(A)(2). 2005 NEC. SEE REVIEWED PLAN FOR | | DEFICIENCIES IN THE MASTER BEDROOM. THESE WERE REDLINED | | ON THE PERMIT SET AND NOT CORRECTTED ON THE REVISION. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2008-06-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-06-23 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-06-18 |
Time |
06:36 |
Sent To |
B |
|
Notes |
2008-06-18 09:21:07 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1 | | AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} 106.1 SUBMITTAL DOCUMENTS. CONSTRUCTION DOCUMENTS, | | SPECIAL INSPECTION AND STRUCTURAL OBSERVATION PROGRAMS, | | AND OTHER DATA SHALL BE SUBMITTED IN ONE TWO OR MORE | | SETS WITH EACH APPLICATION FOR A PERMIT.ONLY ONE RISER | | WAS SUBMITTED. CALLED ALFONSE AND LEFT A MESSAGE ON | | 6/18/08 AND HELD THE REVISION WAITING ON THE SECOND | | COPY FOR THREE DAYS. | | | | 2} 210.70(2)(B) REQUIRES AN EGRESS LIGHT FOR THE NEW | | BEDROOM DOOR. INDICATE COMPLIANCE WITH SAME. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2007-11-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-11-27 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-11-27 |
Time |
07:33 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-08-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-20 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-20 |
Time |
11:59 |
Sent To |
E |
|
Notes |
2008-08-20 12:00:18 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-06-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-06-16 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-06-16 |
Time |
13:59 |
Sent To |
E |
|
Notes |
2008-06-16 13:59:23 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-05-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-05-14 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-05-14 |
Time |
16:15 |
Sent To |
M |
|
Notes |
2008-05-14 16:15:38 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-02-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-29 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-29 |
Time |
10:35 |
Sent To |
Z |
|
Notes |
2008-02-29 10:36:04 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-12-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-12-04 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-11-19 |
Time |
15:54 |
Sent To |
|
|
Notes |
2007-11-19 15:54:14 | TO "SFR" "Z" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2008-05-20 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-05-20 |
Time |
14:58 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-05-20 |
Time |
14:58 |
Sent To |
|
|
Notes |
2008-05-20 14:59:08 | REVISION TO MECH. PLAN AND COOLING LOAD CAL'S. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2008-05-15 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-05-15 |
Time |
09:04 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-05-15 |
Time |
09:04 |
Sent To |
|
|
Notes |
2008-05-15 09:21:54 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | MECHANICAL REVISION | | *** DENIED *** | | | | 1) THE MECHANICAL PLANS NEED THE PRINTED NAME AND | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN WITH | | CONTACT INFORMATION, AND CONTRACTOR INFORMATION IF | | APPLICABLE ON THEM, SEE W.P.B. AMEND. 106.1.3. | | | | 2)THE AIR HANDLER MODEL NUMBERS (FSM3000) LISTED ON | | THE A/C EQUIPMENT SCHEDULE COULD NOT BE FOUND ON THE | | ARI DIRECTORY WEB-SITE, PLEASE CORRECT OR SUBMIT AN ARI | | CERTIFICATE, SEE 2004 FBC 13-607.1.ABC.3.1.1. | | | | 3) SHOW THE A/C SYSTEM SEER ON THE PLAN, PER 2004 FBC | | 13-607.1.ABC.3.1.1. | | | | 4) AS THE A/C SYSTEM HAS BEEN INCREASED TO A 2.5 TON | | SYSTEM PLEASE SUBMIT COOLING LOAD CALCULATIONS, PER | | 2004 FBC 13-607.1.ABC.1. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-03-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-03-03 |
Time |
11:46 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-03-03 |
Time |
11:46 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-11-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-11-28 |
Time |
15:51 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2007-11-28 |
Time |
15:51 |
Sent To |
P |
|
Notes |
2007-11-28 15:55:43 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) ENERGY CALCULATIONS LINE 9A-1 IS CALLING FOR R4.2, | | SEE TABLE 6C-1 ON THE SECOND PAGE OF THE ENERGY CAL'S, | | THE MINIMUM INSULATION IS R-5, SEE 2004 FBC | | 13-604.1.C.1. PLEASE CORRECT. | | | | 2)ENERGY CALCULATIONS LINE 10A IS CALLING FOR R19, | | SEE TABLE 6C-1 ON THE SECOND PAGE OF THE ENERGY CAL'S, | | THE MINIMUM INSULATION IS R-30 FOR UNDER ATTIC, SEE | | 2004 FBC 13-604.1.C.1. PLEASE CORRECT. | | | | 3) THE MODEL NUMBER 113RNA035 ON THE MECHANICAL PLAN | | FOR THE A/C CONDENSER UNIT IS A INCORRECT NUMBER, SEE | | 2004 FBC 13-607.ABC.3.1.1, PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-03-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-03-04 |
Time |
07:37 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-03-04 |
Time |
07:37 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2007-12-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-12-04 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-12-04 |
Time |
08:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2008-03-03 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-03-03 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-03-03 |
Time |
08:52 |
Sent To |
M |
|
Notes |
2008-03-03 08:52:56 | ***APPROVED - RESUB #1*** | | | | | | | | | | SENT TO "M" - TG |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-11-20 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-11-20 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-11-20 |
Time |
09:27 |
Sent To |
E |
|
Notes |
2007-11-20 09:31:07 | ***FAILED*** | | | | | | 1)THE VALUE OF PROPOSED WORK EXCEEDS 50% OF THE | | VALUE OF THE HOME.PURSUANT TO ARTICLE XIV OF THE | | ZONING AND LAND DEVELOPMENT REGULATIONS(ZLDRS), A | | LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTION 94-442 | | OF THE ZLDR'S SHALL BE SUBMITTED. | | | | 2)PROVIDE OVERHANG DIMENSIONS.NOTE:PURSUANT TO | | SECTION 94-305 OF THE ZLDRS: STRUCTURAL INTRUSIONS MAY | | NOT PROJECT MORE THAN 3' INTO A REQUIRED SETBACK. | | | | 3)INDICATE SETBACK DIMENSIONS FROM ANY PROPOSED, IF | | ANY, MECHANICAL EQUIPMENT TO THE PROPERTY LINES. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 |
|
|