Plan Review Stops For Permit 07110443 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-04-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-04-15 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-04-15 |
Time |
15:20 |
Sent To |
PC |
|
Notes |
2008-04-15 15:23:23 | BUILDING SUBMITTAL CHECKLIST: | | | | 1-NEED TO PROVIDE COMPLETE PRODUCT APPROVAL | | INFORMATION FOR SLIDING GLASS DOORSUNDER A SEPARATE | | PERMIT AS AGREED ONPROVISO DATED 1-11-08. SEE | | ATTACHED COPY. | | | | ***NOTES: | | A) INFORMATION SUBMITTED IS NOT AN APPROVED PRODUCT | | APPROVAL. NEED TO SUBMIT COMPLETE PRODUCT APPROVAL | | INFORMATION FOR TYPE AND SIZE OF DOOR AS SHOWN ON | | PLANS. IF THERE IS NOT AN APPROVED PRODUCT APPROVAL | | AVAILABLE, THENA SITE SPECIFIC PRODUCT APPROVAL CAN | | BE APLIED FOR.COMPLETE ENGINEERING AND TESTING | | PACKAGE CAN BE SUBMITTED TO OBTAIN APPROVAL.COMPLETE | | PACKAGE WILL BE ROUTED TO MR. ROBERT BROWN, LICENSE & | | PERMIT SERVICES MANAGER/ABO (561)805-6652,FOR REVIEW | | AND APPROVAL. | | | | B) REVISED PLANS SUBMITTED ARE APPROVED AND STAMPED BY | | ALL TRADES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-02-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-02-20 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-02-20 |
Time |
16:50 |
Sent To |
PC |
|
Notes |
2008-02-20 16:58:32 | NEWSINGLE FAMILY RESIDENCE BUILDINGREVISION | | CHECKLIST. | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1- NEED TO REVISE WIND EXPOSURE CLASSIFICATIONS TO "C" | | FROM "B" AS REQUIRED BY SEC. R301.2.1.4(3)OF 2004 | | FLORIDA RESIDENTIAL CODE.SEE ATTACHED COPY OF CODE | | SECTION.NEED TO REVISE INFORMATION ON SHEET T1 AND | | ALSO NEED TO REVISE OPENINGS DESIGN PRESSURES ON | | EXTERIOR ELEVATIONS AS REQUIRED BY TABLE R301.2.(3) OF | | 2004 FLORIDA RESIDENTIAL CODE TO VERIFY THAT PRODUCT | | APPROVALS WILL MEET THE REVISED DESIGN PRESSURES. | | | | 2- OWES $30.36 FOR REVISION UPDATED VALUATION. | | | | REMAINDER: | | PROVIDE INFORMATION REQUESTED ON PROVISO AS SOON AS | | POSSIBLE TO AVOID DELAYS OR CONFLICTS. | | | | JULIO GOMEZ | | BUILDING PLANSEXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-01-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-01-11 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-01-10 |
Time |
16:36 |
Sent To |
PC |
|
Notes |
2008-01-11 13:53:29 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- AS AGREED WITH KIM LIDDELLON 1-11-08 OVER THE | | PHONE, PROVIDE PRODUCT APPROVALFOR SLIDING GLASS | | DOORS SIZE AS SHOWN ON PLANS AND FOR STORM SHUTTERS (IF | | DOORS HAVE NOT IMPACT GLAZING)UNDER A SEPARATE | | PERMIT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-12-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-12-11 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-12-11 |
Time |
07:42 |
Sent To |
PC |
|
Notes |
2007-12-11 16:33:15 | NEW RESIDENCE BUILDING REVIEW CHECKLIST. | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | FLORIDA STATUTE. | | | | 2- SHEET T1:REVISE THE ALLOWABLE STRESS OF MASONRY | | UNITS. SEE SEC. R606.4 OF 2004 FLORIDA RESIDENTIAL CODE | | AND REVISE CONCRETE UNIT MASONRY NOTES D AND I. | | | | 3- SHEET A1: REVISE DETAIL 5.DIMENSIONS 6" AND 8" | | DON'T ADD UP TO 10". REVISE AS REQUIRED. | | | | 4- PROVIDE COMPLETE SPECIFICATIONS AND LISTING FOR | | EXTERIOR FIREPLACE INSTALLATION AS SHOWN ON PLANS AND | | AS REQUIRED BY SEC. R1002.1 AND SEC. R102.4 OF 2004 | | FLORIDA RESIDENTIAL CODE. | | | | 5- SHEET A3: REVISE CONNECTOR "C" SPECIFIED FOR GIRDER | | TRUSS ABOVE CLUB ROOM BY THE OPTIONAL DESK AREA.NEED | | TO SPECIFY WOOD TO MASONRY CONNECTOR. SEC. 106.1.2 CITY | | AMENDMENTS TO FBC 2004. | | | | 6- SHEET A6: REVISE ROOF SHEATHING SCHEDULE.MINIMUM | | REQUIREMENT IS TO USE 8D RING SHANK NAILS. SEE SEC. | | R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | 7- PROVIDE SURVEY WITH ORIGINAL SIGNATURE AS REQUIRED | | BY CHAPTER 472 OF FLORIDA STATUTE. | | | | 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | 9B-72 FOR: | | A) 2" MULLIONS AS SHOWN ON PLANS. | | | | B) SLIDING GLASS DOORS.SIZE OF DOORS SHOWN ON | | PRODUCT APPROVAL SUBMITTED IS SMALLER THAN THE ONE | | SPECIFIED ON PLANS. | | ALSO, PROVIDE COMPLETE INSTALLATION SPECIFICATIONS AND | | DRAWINGS. | | | | C) FIXED WINDOWS. NEED TO PROVIDE CURRENT REVISED FL | | 243-R5 WITH CORRESPONDING NOA. | | | | D) SINGLE HUNG WINDOWS. NEED TO PROVIDE CURRENT | | REVISED FL 239-R10 WITH CORRESPONDING NOA. | | | | 9- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY | | AMENDMENTS TO FBC 2004. | | | | 10- PROVIDE STRUCTURAL BUCK DETAIL USING 2X BUCK AS | | REQUIRED BY PRODUCT APPROVAL SUBMITTED FOR SLIDING | | GLASS DOORS SUBMITTED.SEC. 106.1.2 CITY AMENDMENTS TO | | FBC 2004. | | | | 11- SOIL TEST REPORT IS TOO OLD. IT WAS DONE IN MARCH | | 3, 2004. NEED TO PROVIDE CURRENT SOIL TEST REPORT. SEC. | | R401.4 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | 12- OWES $103.08 FOR UPDATED VALUATION AND RADON FEES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561) 805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2008-08-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-08-14 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-08-14 |
Time |
10:10 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2008-07-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-07-28 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-07-28 |
Time |
11:25 |
Sent To |
PC |
|
Notes |
2008-07-28 12:22:31 | | | | | REVISION DENIED | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC CHAPTER 1 AS AMENDED AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} PANEL "C" DOES NOT HAVE THE REQUIRED CLEARANCE PER | | 110.26. | | | | 2} THE #3 CU GROUNDING ELECTRODE IS IN VIOLATION OF | | 250.66. A 1/0 IS REQUIRED FOR THE 400 AMP SERVICE AS IS | | ON THE PERMITTED SRT OF PLANS. | | | | 3} THE RISER DIAGRAM INDICATES 2-#3 FEEDERS TO PANEL | | "D", THE PANEL SCHEDULE INDICATES #6 FEEDERS, CORRELATE | | SAME. | | | | 4}SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER | | 440.14, FOR THE A/C COMPRESSERS. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2008-04-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-04-09 |
Time |
07:48 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-04-09 |
Time |
06:47 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2008-02-19 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-02-19 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-02-19 |
Time |
08:59 |
Sent To |
P |
|
Notes |
2008-02-19 09:24:02 | | | | | | | REVISION DENIED | | | | THESE COMMENTS WERE PUT IN AS A PROVISO ON THE PERMIT | | SET AND HAVE NOT BEEN ADDRESSED. | | | | 1} THERE ARE TWO SERVICE LOCATIONS INDICATED ON THE | | PLANS, REMOVE ONE. | | | | 2} THE KITCHEN ISLAND MUST HAVE A RECEPTACLE TO COMPLY | | WITH 210.52(C)(2). | | | | THESE ITEMS MUST BE CORRECTED ON THE PLAN PRIOR TO | | SUBMITTING THE FIRST REVISION OR CALLING FOR ELECTRICAL | | INSPECTION. | | | | THE ARCHITECT MUST BE MADE AWARE OF THIS PROVISO. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-01-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-08 |
Time |
07:38 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-01-08 |
Time |
06:51 |
Sent To |
P |
|
Notes |
2008-01-08 07:38:09 | | | | | | | SAME NOTES AS PREVIOUS REVIEW (PROVISO), SAME SHEET | | RESUBMITTED (A7)./WRT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2007-11-20 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-11-20 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-11-20 |
Time |
09:01 |
Sent To |
M |
|
Notes |
2007-11-20 10:21:37 | | | | | | | | | | | PROVISO | | | | THERE ARE TWO SERVICE LOCATIONS INDICATED ON THE PLANS, | | REMOVE ONE. | | | | THE KITCHEN ISLAND MUST HAVE A RECEPTACLE TO COMPLY | | WITH 210.52(C)(2). | | | | BEDROOM #2 MUST HAVE ANOTHER RECEPTACLE ADDED TO COMPLY | | WITH 210.52(A)(1). | | | | THESE ITEMS MUST BE CORRECTED ON THE PLAN PRIOR TO | | SUBMITTING THE FIRST REVISION OR CALLING FOR ELECTRICAL | | INSPECTION. | | | | THE ARCHITECT MUST BE MADE AWARE OF THIS PROVISO. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2009-02-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-27 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-27 |
Time |
10:21 |
Sent To |
Z |
|
Notes |
2009-02-27 10:22:28 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2008-08-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-04 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-04 |
Time |
14:28 |
Sent To |
E |
|
Notes |
2008-08-04 14:29:13 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2008-07-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-22 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-22 |
Time |
08:38 |
Sent To |
E |
|
Notes |
2008-07-22 08:38:57 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-07-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-11 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-11 |
Time |
11:10 |
Sent To |
M |
|
Notes |
2008-07-11 11:11:19 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-05-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-05-12 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-05-12 |
Time |
14:13 |
Sent To |
P |
|
Notes |
2008-05-12 14:13:20 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-04-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-02 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-02 |
Time |
15:27 |
Sent To |
E |
|
Notes |
2008-04-02 15:28:02 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-02-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-12 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-12 |
Time |
14:45 |
Sent To |
E |
|
Notes |
2008-02-12 14:46:04 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-01-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-03 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-03 |
Time |
15:16 |
Sent To |
Z |
|
Notes |
2008-01-03 15:16:31 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-12-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-12-11 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-11-16 |
Time |
15:46 |
Sent To |
|
|
Notes |
2007-11-16 15:46:32 | TO "SFR" "Z" |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
P |
Date |
2009-03-02 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2009-03-02 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2009-03-02 |
Time |
09:28 |
Sent To |
Z |
|
Notes |
2009-03-02 11:53:44 | ***LANDSCAPE REVIEW PASSED WITH PROVISO: | | | | 1. PROVIDE REQUIRED STREET TREES TO BE CONSISTENT WITH | | THE BALANCE OF STREET. | | | | 2. GRAVEL SHALL BE CONTAINTED AND UNLESS THERE IS A | | HEDGE ALONG THE NEIGHBORING PROPERTY LINE TO THE WEST, | | SOD SHALL BE USED. | | | | 3. HARDSCAPE ELEMENTS (DECKS, POOLS, DRIVES, ETC) SHALL | | BE ACCURATELY SHOWN ON THE PLAN. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-07-11 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-11 |
Time |
14:03 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-07-11 |
Time |
14:03 |
Sent To |
|
|
Notes |
2008-07-11 14:05:22 | REVISION TO MECH. PLANS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2007-11-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-11-28 |
Time |
14:55 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-11-28 |
Time |
14:55 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2008-05-15 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-05-15 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-05-15 |
Time |
08:57 |
Sent To |
|
|
Notes |
2008-05-15 09:00:05 | AS-BUILT RISER DIAGRAM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2008-04-14 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-04-14 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-04-14 |
Time |
08:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2008-02-20 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-02-20 |
Time |
08:53 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-02-20 |
Time |
08:40 |
Sent To |
B |
|
Notes |
2008-02-20 09:01:35 | DENIED; | | 1. BATHROOM TWO IS THE BATHROOM TO BE DELETED NOT | | BATHROOM NUMBER 4. BATHROOM TWO IS STILL SHOWN ON | | SANITARY RISER DIAGRAM. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-01-08 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-01-08 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-01-08 |
Time |
14:39 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2007-12-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-12-04 |
Time |
07:54 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-12-04 |
Time |
07:51 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2008-01-07 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-01-07 |
Time |
09:23 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-01-07 |
Time |
09:23 |
Sent To |
E |
|
Notes |
2008-01-07 09:23:52 | ***APPROVED - RESUB #1*** | | | | | | | | SENT TO "E" - BT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-11-19 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-11-19 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-11-19 |
Time |
11:36 |
Sent To |
E |
|
Notes |
2007-11-19 11:43:37 | ***FAILED*** | | | | | | 1)INDICATE BUILDING HEIGHT FROM GRADE TO THE | | MIDPOINT OF THE ROOF'S PITCH (HIGHEST ROOF).I HAVE | | RECHECKED THE PLANS, BETWEEN SHEET A4 OR A5 THE HEIGHT | | IS SHOWN FROM GRADE ON ONLY ONE ELEVATION, IT SHALL BE | | SHOWN ON ALL ELEVATIONS. | | | | 2)PROPOSED DRIVEWAY EXCEEDS MAXIMUM SQUARE FOOTAGE | | ALLOWABLE.PURSUANT TO SECTION 94-482(A) OF THE CITY | | OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | REGULATIONS (ZLDRS):LOCATION AND SURFACE.REQUIRED | | OFF-STREET PARKING SPACES FOR LESS THAN FOUR | | RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE | | PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED | | PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE | | LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT | | YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN | | THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH, | | NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION | | 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO | | PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS | | ARTICLE. | | | | 3)THE DETERMINATION HAS BEEN MADE BY ANGELLA VANN, | | DEPUTY PLANNING DIRECTOR, THAT A TYPICAL LANDSCAPING | | PLANTING LIST IS NOT SUFFICIENT.A LANDSCAPE PLAN | | SHOWING COMPLIANCE WITH SECTION 94-442 OF THE ZLDRS | | SHALL BE SUBMITTED WITH EVERY APPLICATION FOR BUILDING | | PERMIT AND SHALL MEET THE MINIMUM REQUIREMENTS FOUND IN | | SECTION 94-442 AND 94-445 OF THE ZLDRS. | | | | 4)PROVIDE AN EASEMENT CONSENT FORM FROM THE CITY OF | | WEST PALM BEACH DEPARTMENT OF PUBLIC UTILITIES (1ST | | FLOOR, CITY HALL) APPROVING THE PROPOSED FENCE AND | | COLUMNS. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 |
|
|