Plan Review Stops For Permit 07110417 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2008-03-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-03-24 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-03-24 |
Time |
15:57 |
Sent To |
|
|
Notes |
2008-03-24 16:37:04 | REVISED THREE PRODUCT APPROVALS | | | | DENIED BY BUILDING | | | | 1) THE PRODUCT APPROVALS FOR THE SH-4000 PGT WINDOWS | | AND THE MASONITE STEEL DOORS HAVE BEEN REVIEWED FOR | | CODE COMPLIANCE. | | | | 2) THE INSTALLATION SCHEDULE FOR THE ALUFAB STORM | | PANELS IS INCORRECT. THE MOUNT TYPE SPECIFIED IS FOR | | VERTICAL INSTALLATION. THE EDGE DISTANCE IS SPECIFIED | | AS 2" WHICH REQUIRES THE ANCHOR SPACING TO BE REDUCED | | BY HALF. PLEASE CORRECT. | | | | 3) THE NUMBER OF PRODUCT APPROVALS REVISED IS THREE. | | THEREFORE AND ADDITIONAL $20.00 IN REVISION FEES IS | | DUE. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-02-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-02-01 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-02-01 |
Time |
13:01 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-01-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-01-22 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-01-22 |
Time |
14:39 |
Sent To |
|
|
Notes |
2008-01-22 15:49:55 | 2004 FBC W/2007 REVISIONS | | RESIDENTIAL REHAB | | | | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) THE INSTALLATION SCHEDULE FOR THE STORM PANELS IS | | INCORRECT. THE PLANS SHOW THE OPENING WIDTH FOR THE | | THREE FRONT WINDOWS THAT ARE MULLED TOGETHER AS 10'-2" | | (122") AND THE SCHEDULE THE WAS SUBMITTED HAS 101". | | THE SCHEDULE INDICATES THAT THE PANELS WILL ALL BE | | INSTALLED HORIZONTALLY. HOWEVER, TABLE 1 ON PAGE 9 OF | | THE PRODUCT APPROVAL ALLOWS A MAXIMUM SPAN OF 105" FOR | | 60 PSF. THE PRODUCT APPROVAL HAS BEEN MARKED TO | | INDICATE THAT A "H" HEADER WILL BE USED. HOWEVER, THIS | | CAN NOT BE USED IF THE PANELS ARE MOUNTED HORIZONTALLY. | | IF THE PANELS ARE MOUNTED VERTICALLY SPECIFY HOW THE | | BOTTOM WILL BE ATTACHED. | | | | 3) ONE SET OF PLANS DOES NOT HAVE THE EMBOSSED RAISED | | SEAL OF THE ENGINEER AS REQUIRED BY FS 471 AND FAC | | 61G-15-23.002. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-12-04 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2007-12-04 |
Time |
19:40 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2007-12-04 |
Time |
18:32 |
Sent To |
I |
|
Notes |
2007-12-04 19:42:54 | PLEASE ADDRESS PREVIOUSLY STATED COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-11-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-11-19 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-11-19 |
Time |
14:28 |
Sent To |
M |
|
Notes |
2007-11-19 14:28:07 | 2004 FBC W/2007 REVISIONS | | RESIDENTIAL REHAB | | | | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) THE SCOPE OF WORK ON A1 SPECIFIES THAT A 2'-8" STEEL | | DOOR IS TO BE INSTALLED. THE PLANS SHOW A 2'-8" INSWING | | EXTERIOR DOOR AND THE PRODUCT APPROVAL THAT WAS | | SUBMITTED IS FOR AN OUTSWING DOOR. PLEASE CLARIFY.FBC | | *106.1.1 CITY AMENDMENTS | | | | 3)SPECIFY THE COMPONENT AND CLADDING PRESSURES FOR | | THE EXTERIOR DOOR THAT IS BEING REPLACED. SEE FBC TABLE | | R301.2(2). | | | | 4) SUBMIT A KEY PLAN AND INSTALLATION SCHEDULE FOR THE | | STORM PANELS. SPECIFY THE MOUNT TYPE, ANCHOR TYPE AND | | SPACING, SPAN, EDGE DISTANCE, ETC. THIS INFORMATION IS | | CONTAINED IN THE PRODUCT APPROVAL. SEE ATTACHED SAMPLE | | INSTALLATION SCHEDULE. | | | | 5) SUBMIT ENERGY CALCULATIONS ON FORM 600C-04R AS | | REQUIRED BY FBC 13-101.4.1. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-01-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-30 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-01-30 |
Time |
12:17 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-01-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-22 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-01-10 |
Time |
07:35 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-01-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-11-19 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-11-19 |
Time |
10:02 |
Sent To |
M |
|
Notes |
2007-11-19 10:34:40 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | | | ALL COMMENTS RELATE TO SHEET A1, UNLESS OTHERWISE | | NOTED. ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS | | OTHERWISE NOTED. | | | | 1} INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE PLAN | | IS NEW OR EXISTING. IF NEW INCLUDE IN THE DESCRIPTION | | ON THE APPLICATION, PROVIDE AN AIC RATING, AND LOCATE | | ALL SERVICE EQUIPMENT ON THE PLAN, METER ENCLOSURE, | | DISCONNECTS AND PANELS, SO THAT COMPLIANCE WITH | | ARTICLES 225 AND 230 CAN BE REVIEWED. PROVIDE A RISER | | DIAGRAM WITH CONDUCTOR AND CONDUIT SIZE AND TYPE. | | | | 2} DUE TO THE PANEL LOCATION, A DISCONNECT MAY BE | | REQUIRED PER 230.70, 225.32. INDICATE LOCATION ON PLAN | | PER 230.72(A)(1) . | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-03-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-24 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-24 |
Time |
09:01 |
Sent To |
B |
|
Notes |
2008-03-24 09:01:55 | TO "RMCDOUGAL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-01-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-09 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-09 |
Time |
11:29 |
Sent To |
E |
|
Notes |
2008-01-09 11:29:32 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-12-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-12-04 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-11-16 |
Time |
11:27 |
Sent To |
|
|
Notes |
2007-11-16 11:28:13 | TO "SFR" "E" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2008-01-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-01-30 |
Time |
13:49 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2008-01-30 |
Time |
13:49 |
Sent To |
P |
|
Notes |
2008-01-30 13:50:21 | REVIEWED AND STAMPED ON 1-17-08. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-01-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-30 |
Time |
12:39 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-01-17 |
Time |
12:00 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-11-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-11-28 |
Time |
11:48 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2007-11-28 |
Time |
11:48 |
Sent To |
P |
|
Notes |
2007-11-28 12:26:40 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) THE MECHANICAL PLAN NEEDS TO SHOW THE SIZE OF THE | | RETURN AIR TRANSFER DUCTS (FLEX) TO THE BEDROOMS, SEE | | 2004 FBC/R M1602.4. | | | | 2) SHOW ON MECHANICAL PLAN HOW THE AIR IS RETURNING | | BACK TO THE AIR HANDLER, SEE 2004 FBC/R M1602.1. | | | | 3) MECHANICAL PLANS SHOWS THE AIR HANDLES SUPPLYING | | 1,032 CFM'S TO THE HOUSE, WHEN THE UNIT ONLY SUPPLIES | | 800 CFM'S. PLEASE SUBMIT MANUAL D CALCULATIONS FOR | | RESIDENTIAL DUCT DESIGN, PER 2004 FBC/R M1601.1 AND FBC | | 13-610.1.ABC.1. DUCT SYSTEMS SERVING HEATING, COOLING | | AND VENTILATION EQUIPMENT SHALL BE FABRICATED IN | | ACCORDANCE WITH THE PROVISIONS OF THIS SECTION AND ACCA | | MANUAL D OR OTHER APPROVED METHODS. (AND)ALL AIR | | DISTRIBUTION SYSTEMS SHALL BE SIZED AND DESIGNED IN | | ACCORDANCE WITH RECOGNIZED ENGINEERING STANDARDS SUCH | | AS ACCA MANUAL D OR OTHER STANDARDS BASED ON THE | | FOLLOWING: | | | | 4) ADD THE A/C EQUIPMENT LISTING WITH ALL PERTINENT | | INFORMATION TO THE MECHANICAL PLAN NOT A SEPARATE | | PAPER, SEE 2004 WPB AMEND. 106.3.5.4 (10). | | | | 5) SHOW THE LOCATION OF THE A/C CONDENSER UNIT ON THE | | MECHANICAL PLAN. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2008-02-01 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-02-01 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-02-01 |
Time |
13:55 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2008-01-18 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-01-18 |
Time |
07:39 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-01-18 |
Time |
07:30 |
Sent To |
B |
|
Notes |
2008-01-18 09:14:33 | DENIED; | | 1. ALL INFORMATION/DRAWINGS/SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPON- | | SIBLE FOR THE DESIGN. SECTION 104.2.1 | | 2. AUTOMATIC CLOTHS WASHER FIXTURE DRAIN | | SHALL CONNECT TO A BRANCH DRAIN A MINIMUM | | OF 3" IN DIAMETER. SEE FBC-PLUMBING SECTION 406.3. | | 3. W/M NOT VENTED. SEE FBC RESIDENTIAL SECTION | | P3101.2.1 | | 4. CLEANOUT REQUIRED ON WASHER STACK, SECTION | | P3005.2.6 | | 5. W/M DISCHARGE CANNOT DRAIN INTO A BATHROOM | | GROUP. MUST BE DOWN STREAM. SECTION | | P3108.1. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-12-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-12-04 |
Time |
07:12 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-12-04 |
Time |
07:12 |
Sent To |
|
|
Notes |
2007-12-04 07:15:48 | SANITARY RISER DIAGRAM REQUIRED SHOWING W/M ADDITION. | | SIZE ALL DRAINAGE AND VENT PIPING. SEE FBC BUILDING | | SECTION 106.3.5.4. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|