Plan Review Details - Permit 07100838
Plan Review Stops For Permit 07100838
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-12-13 Cont ID  
Sent By shill Date 2007-12-13 Time 18:18 Rev Time 0.00
Received By shill Date 2007-12-13 Time 18:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-12-03 Cont ID  
Sent By shill Date 2007-12-03 Time 14:13 Rev Time 0.00
Received By shill Date 2007-12-03 Time 14:13 Sent To  
Notes
2007-12-03 14:15:23****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 _XX_1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER
 BARRIER REQUIRED FS553.844(5)(A). PROVIDE
 INFORMATION (PRODUCT APPROVAL OR SPECIFICATIONS) TO
 SHOW HOW YOU WILL COMPLY WITH THIS REQUIREMENT.
 INFORMATION IS AVAILABLE AT WWW.BOAF.NET, HURRICANE
 MITIGATION.
  
 ____2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY;
 MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF
 EACH ROOF TYPE
  
 _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
  
 _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS. SEVERAL DIFFERENT ASSEMBLIES WERE
 SUBMITTED, SOME FOR TILE UNDERLAYMENT.
  
 _XX_5.)FOR THE LOW SLOPE ROOF, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.THIS IS TO
 BE EITHER WRITTEN ON THE PRODUCT APPROVAL OR SUBMITTED
 ON LETTERHEAD, TWO SETS (NOT WRITTEN ON THE RESUB
 SHEET).
  
 _XX_6.)REVISE THE PERMIT APPLICATION TO REFLECT
 SCOPE OF WORK.APPLICATION STATES SHINGLES, MODIFIED
 PRODUCT APPROVALS SUBMITTED.IF YOU ARE INSTALLING TWO
 DIFFERENT ROOF SYSTEMS, PROVIDE PRODUCT APPROVALS FOR
 THE SHINGLES AND A ROOF PLAN.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-11-05 Cont ID  
Sent By kconrad Date 2007-11-05 Time 08:11 Rev Time 0.00
Received By kconrad Date 2007-11-05 Time 08:11 Sent To I
Notes
2007-11-05 08:25:31THE ROOF WAS INSPECTED TO DETERMINE WHETHER OR NOT A
 ROOF RECOVER IS WARRANTED. THE ROOF PLANKING APPEARED
 TO BE DETERIORATED AT 2 LOCATIONS. AS PER THE FLORIDA
 EXISTING BUILDING CODE, A RE-ROOF IS REQUIRED. SEE ITEM
 #5.
  
  
 511.3RECOVERING VERSUS REPLACEMENT.
  
 NEW ROOF COVERINGS SHALL NOT BE INSTALLED WITHOUT FIRST
 REMOVING EXISTING ROOF COVERINGS WHERE ANY OF THE
 FOLLOWING CONDITIONS OCCUR:
 1. WHEN THE OLD ROOFING IS WATER-SOAKED OR DETERIORATED
 TO THE POINT THAT IT IS NOT SUITABLE AS A BASE FOR
 ADDITIONAL ROOFING.
 2. WHEN BLISTERS EXIST IN ANY ROOFING, UNLESS BLISTERS
 ARE CUT OR SCRAPED OPEN AND NAILED DOWN BEFORE APPLYING
 ADDITIONAL ROOFING.
 3. WHEN THE EXISTING ROOF SURFACE IS GRAVEL OR THE
 LIKE, THE GRAVEL SHALL BE THOROUGHLY REMOVED OR ALL
 LOOSE GRAVEL REMOVED AND APPROVED BASE MATERIAL
 INSTALLED BEFORE APPLYING ADDITIONAL ROOFING.
 4. WHEN EXISTING ROOF IS SLATE OR THE LIKE.
 5. WHEN SHEATHING OR SUPPORTS ARE DETERIORATED TO THE
 POINT THAT THE ROOF STRUCTURAL SYSTEM IS NOT
 SUBSTANTIAL ENOUGH TO SUPPORT RECOVERING.
 6. WHEN EXISTING ROOF HAS TWO OR MORE APPLICATIONS OF
 ANY TYPE ROOFING MATERIAL. CONFORMANCE WITH THIS ITEM
 SHALL MAKE REPLACEMENT MANDATORY.
 EXCEPTIONS:
 1. BUILDING AND STRUCTURES LOCATED WITHIN THE
 HIGH-VELOCITY HURRICANE ZONE SHALL COMPLY WITH THE
 PROVISIONS OF SECTIONS 1512 THROUGH 1525 OF THE FLORIDA
 BUILDING CODE, BUILDING.
 2. WHEN THE STRUCTURAL DECK IS CONCRETE AND THE
 EXISTING ROOF IS FIRMLY ATTACHED TO THE DECK, THEN THE
 ROOF SHALL BE REMOVED DOWN TO A MINIMUM OF THREE PLIES
 OF MOISTURE-FREE FELTS.
 3. WHEN OTHERWISE APPROVED BY THE BUILDING OFFICIAL.
 4. WOOD SHINGLES OR SHAKES SHALL NOT BE PLACED OVER
 MORE THAN ONE APPLICATION OF WOOD OR ASPHALT SHINGLES.
 WOOD SHINGLES OR SHAKES MAY BE PLACED OVER EXISTING
 SHAKES WHEN INSTALLED IN ACCORDANCE WITH CEDAR SHAKE
 AND SHINGLE BUREAU RECOMMENDATIONS.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2007-10-29 Cont ID  
Sent By ssherman Date 2007-10-29 Time 16:19 Rev Time 0.00
Received By ssherman Date 2007-10-29 Time 16:19 Sent To  
Notes
2007-10-29 16:19:51HISTORICAL APPROVAL PER JILLIAN PAPA

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-11-30 Cont ID  
Sent By adarroug Date 2007-11-30 Time 08:15 Rev Time 0.00
Received By adarroug Date 2007-11-30 Time 08:15 Sent To B
Notes
2007-11-30 08:15:57TO "KCONRAD" DESK/RESUB