Plan Review Stops For Permit 07100754 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-01-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-01-03 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-01-03 |
Time |
11:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-11-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-11-08 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-11-08 |
Time |
16:18 |
Sent To |
|
|
Notes |
2007-11-08 16:19:42 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.THE SAFETY REQUIREMENTS ARE NOT COMPLIANT WITH FBC | | R4101.17.IT STATES "ONE OF THE FOLLOWING" BUT ITEMS 3 | | AND 4 ARE TO BE USED IN COMBINATION WITH A PERIMETER | | FENCE; THIS APPLIES WHEN THE HOUSE IS A BARRIER. | | REVISE SAFETY NOTES. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2007-10-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-10-30 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-10-30 |
Time |
14:14 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2007-12-21 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-12-21 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-12-21 |
Time |
16:05 |
Sent To |
B |
|
Notes |
2007-12-21 16:06:49 | CONTRACTOR INFORMATION | | NOTE: GAS PERMIT REQUIRED. LICENSED GAS OR PLUMBING | | CONTRACTOR TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL | | GAS INSPECTIONS TO BE COMPLETE BEFORE FINAL POOL | | INSPECTION. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2007-11-07 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-11-07 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-11-07 |
Time |
09:05 |
Sent To |
Z |
|
Notes |
2007-11-07 09:06:24 | NOTE: REFERENCE PLUMBING PLAN REVIEW. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-12-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-12-19 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-12-19 |
Time |
16:38 |
Sent To |
Z |
|
Notes |
2007-12-19 16:38:29 | TO "Z" BOX/RESUB |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2007-12-21 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-12-21 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-12-21 |
Time |
15:46 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-11-07 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-11-07 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-11-07 |
Time |
08:56 |
Sent To |
G |
|
Notes |
2007-11-07 09:04:50 | DENIED | | REFERENCE: | | ** FBC-2004 WITH 05 & 06 REVISIONS, SECTIONS 424.2 & | | R4101 SWIMMING POOLS. | | ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE (FAC). | | ** FLORIDA STATUTES (FS). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1) PERMIT APPLICATION IS INDICATING AN ELECTRIC POOL | | HEATER, SHEET 1, POOL EQUIPMENT IS INDICATING A 400,000 | | BTU GAS POOL HEATER. PLEASE CLARIFY AND CORRELATE WHICH | | TYPE OF POOL HEATER IS BEING USED ON THE RESUBMITTAL. | | PER * 106.1.1, INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 2) FBC-2004 SEC. 424.2.14.1, OR | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | WATER HEATERS SHALL BEAR THE LABEL OF A | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | SHEETS REQUIRED, PLEASE SUBMIT) | | | | 3) FBC-2004 SEC. 424.2.14.2, OR | | FBCR-2004 SEC. R4101.14.2 WATER | | RETENTION, PROVIDE A POSITIVE MEANS OF | | RETAINING WATER IN THE HEATER WHEN PUMP | | IS SHUT OFF.(MANUFACTURE SHEETS | | REQUIRED, PLEASE SUBMIT) | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-12-21 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-12-21 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-12-21 |
Time |
14:00 |
Sent To |
P |
|
Notes |
2007-12-21 14:00:54 | ***APPROVED - RESUB #1*** | | | | FENCE ENCLOSURE ON PERMIT #07120340 | | | | | | | | SENT TO "P" - MP |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-11-07 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-11-07 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-11-07 |
Time |
13:45 |
Sent To |
B |
|
Notes |
2007-11-07 13:47:20 | ***FAILED*** | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM POOL EQUIPMENT TO | | ALL PROPERTY LINES.NOTE:MECHANICAL EQUIPMENT MAY | | NOT PROJECT MORE THAN 4' INTO ANY REQUIRED SETBACK. | | | | 2)AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT | | FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT | | SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO | | THE MINIMUM STANDARDS PROVIDED BELOW. | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B)+(C): | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | HEIGHT ABOVE GRADE. | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 |
|
|