2007-11-02 13:05:44 | DENIED |
| REFERENCE: |
| ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING. |
| ** FBC-2004 CHAPTER 1, THE CITY OF |
| WEST PALM BEACH AMENDMENTS. |
| ** FLORIDA ADMINISTRATIVE CODE (FAC). |
| ** FLORIDA STATUTES (FS). |
| |
| THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR |
| PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: |
| |
| 1. MORE INFORMATION IS REQUIRED DUE TO THE FACT THAT A |
| PLUMBING PERMIT HAS BEEN APPLIED FOR PROPOSED PLUMBING |
| TO A NEW LAUNDRY BOX. PLEASE PROVIDE THE FOLLOWING |
| INFORMATION AS IT PERTAINS TO YOUR JOB. |
| |
| *** IF THE NEW PROPOSED PLUMBING FLOOR PLAN LAYOUT IS |
| DIFFERENT FROM THE EXISTING FLOOR PLAN LAYOUT PLEASE |
| SUBMIT THE FOLLOWING INFORMATION ON SEPERATE DRAWINGS. |
| |
| |
| A) EXISTING FLOOR PLAN LAYOUT. |
| |
| B) NEW PROPOSED FLOOR PLAN LAYOUT AND PLEASE FOLLOW |
| WHAT IS REQUIRED IN COMMENT #2. |
| |
| 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 |
| RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A |
| PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING |
| ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT |
| LOCATIONS OF THE PROPOSED PLUMBING TO THE NEW LAUNDRY |
| BOX IS REQUIRED. |
| |
| 3. THE FOLLOWING INFORMATION IS REQUIRED FOR THE |
| PROPOSED PLUMBING TO THE NEW LAUNDRY BOX |
| |
| (A) 406.3 WASTE CONNECTIONS.THE TRAP AND |
| FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES |
| WASHER SHALL BE A MINIMUM OF 2 INCHES |
| (51MM) IN DIAMETER. THE AUTOMATIC |
| CLOTHES WASHER FIXTURE DRAIN SHALL |
| CONNECT TO A BRANCH DRAIN OR DRAINAGE |
| STACK A MINIMUM OF 3 INCHES (76MM) IN |
| DIAMETER. |
| |
| (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY |
| TRAPPED. STANDPIPES SHALL |
| EXTEND A MINIMUM OF 18 INCHES (457MM) |
| AND A MAXIMUM OF 42 INCHES (1066MM) |
| ABOVE THE TRAP WEIR. ACCESS SHALL BE |
| PROVIDED TO ALL STANDPIPES AND DRAINS |
| FOR RODDING. |
| |
| (C) 708.7 MINIMUM SIZE. CLEANOUTS SHALL |
| BE THE SAME NOMINAL SIZE AS THE PIPE |
| THEY SERVE UP TO 4 INCHES (102MM) |
| **NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE THREE |
| INCH (3"). |
| |
| (D) 708.9 ACCESS. ACCESS SHALL BE |
| PROVIDED TO ALL CLEANOUTS. |
| **NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE |
| LOCATED AT FOUR FEET ABOVE FINNISH FLOOR (4' A.F.F.). |
| |
| 4. FBC-2004 CHAPTER 1,SECTION 106.3.4.3: |
| THE PERSON RESPONSIBLE FOR THE DESIGN OF |
| THE DRAWING SHALL CLEARLY PRINT AND SIGN |
| NAME, AND ALSO DATE DRAWING. PLEASE DO |
| THIS PRIOR TO RESUBMITTING. |
| |
| **NOTE: PLEASE REFERENCE THE EXAMPLE SANITARY ISOMETRIC |
| RISER DIAGRAM ATTACHED TO THE PLUMBING COMMENTS THAT |
| REFLECTS THE FLOOR PLAN AND IS CODE COMPLIANT: |
| |
| END OF COMMENTS: |
| |
| REVIEW BY: MIKE PERSON |
| PLUMBING PLANS EXAMINER |
| (561) 805-6730 |
| FAX (561) 805-6731 |
| E-MAIL: [email protected] |