Plan Review Stops For Permit 07100318 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
N |
Date |
2008-04-28 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2008-04-28 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2008-04-28 |
Time |
16:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-09-05 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2008-09-05 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2008-09-05 |
Time |
13:24 |
Sent To |
|
|
Notes |
2008-09-05 13:24:34 | SEE PROVISO ON PLAN. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-04-29 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2008-04-28 |
Time |
1900 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2008-04-28 |
Time |
16:00 |
Sent To |
I |
|
Notes |
2008-04-29 16:30:15 | SPOKE WITH KEVIN DENNEHY AND ADVISED HIM THAT THE SCOPE | | OF WORK WILL BE CHANGED TO REFLECT THE WINDOW/DOOR | | INSTALLATION AND THE PROJECT VALUATION WILL BE | | INCREASED AS WELL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-03-18 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2008-03-18 |
Time |
19:34 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2008-03-18 |
Time |
18:33 |
Sent To |
I |
|
Notes |
2008-03-18 18:46:02 | PROJECT: 1700 PRESIDENTIAL WAY #103 | | | | CODE REVIEW: | | 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS | | 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS | | CITY OF WEST PALM BEACH ADMINISTRATION AMENDMENTS, | | CHAPTER 1, 2004 EDITION | | | | STATUS: FAILED | | | | COMMENTS: | | | | 1) PLEASE SUBMIT (2) COPIES OF EACH: FLORIDA STATE | | PRODUCT APPROVALS AND THE REVISED MIAMI_DADE PRODUCT | | APPROVALS FOR THE PW-701, SH-700 WINDOWS AND THE | | SGD-730 IMPACT SLIDING GLASS DOORS. | | | | PLAN REVIEW: KEN CONRAD | | PHONE: 561.805.6666 | | E-MAIL: KCONRAD @WPB.ORG |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-01-30 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2008-01-30 |
Time |
18:31 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2008-01-30 |
Time |
18:21 |
Sent To |
I |
|
Notes |
2008-01-30 18:30:44 | PROJECT: 1700 PRESIDENTIAL WAY #103 | | | | CODE REVIEW: | | 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS | | 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS | | CITY OF WEST PALM BEACH ADMINISTRATION AMENDMENTS, | | CHAPTER 1, 2004 EDITION | | | | STATUS: FAILED | | | | COMMENTS: | | | | 1) REQUIRE A NOTICE OF COMMENCEMENT AS PER THE | | FOLLOWING: | | | | FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 2) PLEASE INDICATE THE LEVEL OF ALTERATION AS PER THE | | FOLLOWING: | | | | FLORIDA EXISTING BUILDING CODE, SECTION301.5 :A | | DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR A | | COMBINATION OF | | LEVELS OF ALTERATION PURSUANT TO SECTION 303,304 & 305 | | OF THIS CODE. | | | | 3) PLEASE INDICATE ON FLOOR PLAN:NEW WALLS/EXISTING | | WALLS. | | | | 4) PLEASE PROVIDE PRODUCT APPROVALS FOR THE INDICATED | | SLIDING GLASS DOORS. | | | | 5) THE PRESCRIPTIVE FIRE RESISTANCE INDICATED ON THE | | TWO HOUR RATED WALL DOES NOT REFLECT THE DATA SHOWN BY | | TABLE 720.1(2)#13-1.3. | | PLEASE CORRECT THE SAME OR INDICATE A TESTED AND | | APPROVED RATED ASSEMBLY. | | | | 6) PLEASE PROVIDE INTERIOR DIMENSIONS AND SQUARE | | FOOTAGE. | | | | 7) PLEASE PROVIDE ENERGY CALCULATIONS AS PER THE | | FOLLOWING: | | | | 512.1MINIMUM REQUIREMENTS. | | ALTERATIONS SUBJECT TO THIS CHAPTER SHALL COMPLY WITH | | THE REQUIREMENTS OF CHAPTER 13 OF THE FLORIDA BUILDING | | CODE, BUILDING. | | | | END COMMENTS | | | | PLAN REVIEW: KEN CONRAD | | PHONE: 561.805.6666 | | E-MAIL: KCONRAD @WPB.ORG |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-11-02 |
|
|
Cont ID |
|
Sent By |
kconrad |
Date |
2007-11-02 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2007-11-02 |
Time |
15:24 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-04-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-04-16 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-04-16 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2008-03-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-03-14 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-03-14 |
Time |
09:56 |
Sent To |
|
|
Notes |
2008-03-14 09:56:15 | ** DENIED2RD REVIEW ** | | | | ** PLEASE SEE THE NOTES BELOW WHICH ARE FROM THE FIRST | | REVIEW WHICH STILL NEED TO BE ADDRESSED ALONG WITH NEW | | COMMENTS DUE TO INFORMATION NOW BEING ADDED TO PLANS. | | | | 1) NOTE: PLEASE SEE THE RISER WHICH SHOWS NO OCP FOR | | PANEL. | | 230.70, 230.71. IS THIS A METER CENTER? | | | | 2) NOTE: PLEASE SEE THE RISER SHOWS 3-#3, 1#8 AND | | ANOTHER #8? WHAT IS THIS SECOND #8? | | PLEASE CLARIFY. | | 230, 215, 310 | | FBC 106.1.2 | | | | 3) NOTE: PLEASE SEE PREVIOUS REVIEW NOTE WITH RESPECT | | TO 210.11C1, 210.52B1 AND 220.52 AS ONE OR MORE OF THE | | SMALL APPLIANCE, DINING ROOM RECEPTACLE CIRCUITS ETC | | ARE REQUIRED TO BE FIGURED AT 1500VA. PLEASE SEE LOAD | | CALCULATIONS ONLY SHOW THE TWO SMALL APPLIANCE | | CIRCUITS. | | | | 4) NOTE: PLEASE SEE THE CU IS BEING SHOWN ON A 1-POLE | | 20AMP CIRCUIT.HOW CAN THIS BE CORRECT WITH A 2.5 TON | | CU.THE MODEL AS GIVEN BY THE MANUFACTURE STATES A | | MINIMUM OF 230V. | | PLEASE ADJUST. | | 240.4, 310.16, 408.4, 110.3, 90.7 | | FBC 106.1.2 | | | | 5) NOTE: PLEASE SEE KITCHEN COUNTER WHICH REQUIRES GFI | | WITHIN 2FT OF THE END OF COUNTER SPACE. | | PLEASE ALSO SEE THE DISPOSAL IN KITCHEN DOES NOT SHOW | | ANY METHOD FOR CONTROL. WILL THIS BE SELF ACTUATING? | | 210.52C1 | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | 6) NOTE: PLEASE SEE 424.3B WHICH REQUIRES OCP FOR HEAT | | IN AHU TO BE SIZED AT 125%. PANEL SHOWS 40AMP OCP. MIN | | PER SECTION OF CODE GIVEN SHOULD BE 45AMPS. | | THE SIZING OF BRANCH-CIRCUIT CONDUCTORS AND | | OVER-CURRENT DEVICES SUPPLYING FIXED ELECTRIC | | SPACE-HEATING EQUIPMENT AT 125 PERCENT OF THE TOTAL | | LOAD OF THE HEATERS (AND MOTORS) IS PREDICATED ON THE | | NEED TO PROTECT OVER-CURRENT DEVICES, PARTICULARLY IN | | PANEL-BOARDS, AND CONDUCTORS FROM OVERHEATING DURING | | PERIODS OF PROLONGED OPERATION. | | ** THIS ALSO AFFECTS FEEDERS AND LOAD CALCULATIONS. | | | | 7) NOTE: PLEASE GO OVER LOAD CALCULATIONS. BASED ON | | COMMENTS ABOVE THE LOAD WILL BE INCREASING DUE TO SOME | | ITEMS MISSING. | | PLEASE ALSO SEE LOADS SUCH AS DISPOSAL WHICH IS BEING | | SHOWN AS 1500VA ON PANEL SCHEDULE AND 1000VA ON LOAD | | CALCULATIONS. WHAT HAPPENED TO THE OTHER 500VA? PLEASE | | SEE 422.13 AS THIS SPECIFICALLY IDENTIFIES AN ELECTRIC | | WATER HEATER WITH A STORAGE CAPACITY OF 120 GAL OR LESS | | AS A CONTINUOUS LOAD. THIS REVISION REQUIRES THE BRANCH | | CIRCUIT OVERCURRENT DEVICE AND CONDUCTORS TO BE SIZED | | BASED ON 125 PERCENT OF THE WATER HEATER NAMEPLATE | | RATING UNLESS THE OVERCURRENT DEVICE AND THE ASSEMBLY | | IT IS INSTALLED IN ARE LISTED TO BE USED AT 100 PERCENT | | OF ITS CONTINUOUS CURRENT RATING. IN ADDITION, FEEDERS | | AND SERVICES THAT SUPPLY WATER HEATER BRANCH CIRCUITS | | ARE ALSO IMPACTED BY THE FACT THAT THIS TYPE OF | | EQUIPMENT IS CONSIDERED TO BE A CONTINUOUS LOAD. | | AS THE LOAD ON THE SERVICE PANEL IS SHOWN VERY CLOSE TO | | BEING OVERLOADED THERE IS CONCERN OVER THE SIZE. 220, | | 215 ETC | | FBC 106.3.5.1.2, 106.1.2 | | | | 8) NOTE: PLEASE SEE SPECIFIC NOTES ON PREVIOUS REVIEW | | AND ALONG WITH FBC AND FS REQUIRES THE CODE ADOPTED AND | | UNDER DESIGN FOR ANY PROJECT TO BE STATED ON PLANS | | ALONG WITH LEVEL OF ALTERATION. | | FS 553.73 | | CODES WERE ADDED HOWEVER NOT YEAR EDITION AS GIVEN ON | | PREVIOUS REVIEW. | | 2005 NFPA70 | | 2003 NFPA_101 | | 2002 NFPA-72 | | | | 9) NOTE: PLEASE SEE MISSING RECEPTACLE FOR TWO FT OF | | WALL SPACE 210.52 IN BEDRM #3. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-01-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-01-22 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-01-22 |
Time |
14:23 |
Sent To |
|
|
Notes |
2008-01-22 14:23:13 | | | | | ** DENIEDREVIEW ** | | | | 1) NOTE: PLEASE SEE THE FOLLOWING CODES SHALL BE STATED | | ON PLANS FOR RELEVANT DESIGN. | | FBC 2004 W/2007 REVISIONS. | | 2005 NFPA-70 | | 2003 NFPA-101 | | 2002 NFPA-72 | | | | 2) NOTE: PLEASE SEE FS 481.219 FOR POSSIBLE FICTITIOUS | | NAME FOR ARCHITECT. | | PLEASE COMPLETE INFORMATION ON TITLE BLOCKS PER FAC | | 61G1-16.004 | | | | 3) NOTE: PLEASE COMPLETE ALL CIRCUITING ON PLANS AND | | CORRELATE WITH THE PANEL SCHEDULE. | | PLEASE SEE 240.4, 310.16, 408.4 | | FBC 106.3.5.1.2 (ADDITIONAL INFORMATION). | | | | 4) NOTE: PLEASE SEE SOME CIRCUITS ON PANEL SCHEDULE AS | | SHOWN DO NOT COMPLY WITH THE NEC. FOR EXAMPLE: PLEASE | | SEE WATER HEATER WHICH IS SHOWN AS 4500VA LOAD YET THIS | | IS ONLY SHOWN ON A SINGLE POLE 25AMP BRANCH CIRCUIT. | | PLEASE SEE 422.13, 240.4, 310.16 ETC | | | | 5) NOTE: PLEASE SEE NFPA-72 FOR DEFINITIONS OF SMOKE | | DETECTION DEVICES. | | PLEASE SEE THE PLANS CALL FOR *SMOKE DETECTORS* AND BY | | DEFINITION THIS WOULD MEAN THESE ARE PART OF A FIRE | | ALARM SYSTEM. SMOKE DETECTORS ONLY DETECT AND DO NOT | | SOUND WARNING. PLEASE SEE BASED ON PLANS AND PANEL | | SCHEDULE IT SEEMS THESE ARE *SMOKE ALARMS* WHICH | | ACTUALLY DETECT AND SOUND AND ALARM. | | PLEASE CLARIFY AND COMPLETE. | | | | 6) NOTE: PLEASE SEE 210.12 AS ARC FAULT PROTECTION IS | | REQUIRED FOR ALL BRANCH CIRCUITS/OUTLETS IN SLEEPING | | ROOMS. | | PLEASE SEE ONLY ONE BRANCH CIRCUIT FOR SMOKE DETECTION | | TYPE DEVICES SHOWS AFCI BREAKER. | | PLEASE ADJUST AND LIST ALL CIRCUITS REQUIRED. | | | | 7) NOTE: PLEASE SEE 210.52B1, 210.11C1 AND 220.53 FOR | | SMALL APPLIANCE CIRCUITS ALONG WITH DINING AREAS AND | | AREAS OF THE LIKE. | | | | 8) NOTE: PLEASE CLARIFY IF THE PANEL SHOWN ON PLANS IS | | NEW OR ALREADY EXIST? SHOWN ON PLANS AS NEW YET NO | | CONDUCTORS FOR NEW OR EXISTING FEEDERS IS SHOWN. | | 240.4, 310.16 ETC | | | | 9) NOTE: PLEASE SEE NFPA-72 11.8.3 FOR SMOKE DETECTION | | DEVICE LOCATIONS. PLEASE SEE NO DEVICES SHALL BE WITHIN | | 3FT OF DOORS TO BATHROOMS. | | PLEASE SEE OTHER REQUIRED DISTANCES AND ALSO SPECIFIC | | REQUIREMENTS PER THE MANUFACTURE. | | 110.3 | | | | 10) NOTE: PLEASE SEE 210.11C3 FOR MISSING DEDICATED | | BATH CIRCUIT(S). | | MUST BE 20AMP AND #12. | | | | ** PLEASE COMPLETE THE ABOVE AND KNOW AS THERE IS | | INFORMATION NOT YET SHOWN A COMPLETE REVIEW FOR CODE | | COMPLIANCE CAN NOT BE DONE AT THIS TIME. | | | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2008-04-22 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-04-22 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-04-22 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2008-03-20 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-03-20 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-03-20 |
Time |
11:48 |
Sent To |
|
|
Notes |
2008-03-20 12:03:17 | *****DENIED***** | | | | THE FOLLOWING COMMENTS FROM THE PREVIOUS PLAN REVIEW | | STILL NEED TO BE ADDRESSED.CAPS TO INDICATE HOW | | COMMENT CAN BE ADDRESSED | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD | | NFPA 241 TO CODE LIST | | | | 4.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | REFERENCED.ADD 2003 EDITION TO NFPA 101 LISTED IN | | CODE LIST | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-02-11 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-02-11 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-02-11 |
Time |
09:40 |
Sent To |
|
|
Notes |
2008-02-11 09:44:05 | *****DENIED***** | | | | | | 1.THE NUMERICAL ADDRESS SHOWN IN THE TITLE BLOCK OF | | THE SUBMITTED PLAN SHEETS DOES NOT CORRELATE WITH THE | | APPLICATION OR WHAT IS LISTED IN OUR SYSTEM. | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 3.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | 4.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | REFERENCED. | | | | 5.IT IS SHOWN ON THE FLOOR PLAN THAT THE DWELLING | | UNIT HAS SMOKE DETECTORS.BE ADVISED THAT SMOKE | | DETECTORS ARE TIED INTO A BUILDING'S FIRE ALARM SYSTEM; | | WHEREAS SMOKE ALARMS SHALL SOUND ONLY WITHIN AN | | INDIVIDUAL DWELLING UNIT AND SHALL NOT ACTUATE THE | | BUILDING FIRE ALARM.PLEASE INDICATE AS TO WHICH | | DEVICE IS BEING USED. | | | | 6.PLEASE EXPLAIN THE CLOSE PROXIMITY (SPACING) OF THE | | TWO SMOKE DETECTORS/SMOKE ALARMS IN THE LIVING ROOM | | JUST OUTSIDE OF BEDROOM #3. | | | | 7.SPECIFY THE INTERIOR FINISH MATERIAL FOR THE NEW | | WALL IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS | | ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2008-08-22 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-22 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2008-08-22 |
Time |
10:57 |
Sent To |
M |
|
Notes |
2008-08-22 10:58:31 | TO:TOM G. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-08-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-04 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-04 |
Time |
16:08 |
Sent To |
|
|
Notes |
2008-08-08 16:18:26 | TO "BOB"#8 | 2008-08-04 16:09:35 | WAITING FOR "BOB" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-07-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-14 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-14 |
Time |
16:33 |
Sent To |
M |
|
Notes |
2008-07-14 16:33:38 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-07-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-03 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-03 |
Time |
08:48 |
Sent To |
M |
|
Notes |
2008-07-03 08:49:23 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-04-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-15 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-15 |
Time |
09:45 |
Sent To |
|
|
Notes |
2008-04-15 09:50:41 | TO "BOB"#1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-03-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-12 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-12 |
Time |
09:34 |
Sent To |
|
|
Notes |
2008-03-12 09:34:40 | TO "BOB"#9 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-02-11 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-02-11 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-01-18 |
Time |
11:22 |
Sent To |
|
|
Notes |
2008-01-18 11:24:55 | TO "BOB"#16 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
8 |
Status |
P |
Date |
2009-01-24 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-01-24 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-01-24 |
Time |
11:36 |
Sent To |
PC |
|
Notes |
2009-01-24 11:37:58 | REVISED MODEL NUMBERS FOR TRANE EQUIPMENT IN UNIT 103. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
P |
Date |
2008-08-22 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-22 |
Time |
10:58 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-08-22 |
Time |
10:58 |
Sent To |
B |
|
Notes |
2008-08-22 10:59:21 | REVISION TO MECH. PLAN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
F |
Date |
2008-08-11 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-11 |
Time |
09:10 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-08-11 |
Time |
09:10 |
Sent To |
|
|
Notes |
2008-08-11 09:13:52 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | MECHANICAL REVISION | | *** DENIED *** | | | | 1) ONLY ONE PLAN WAS SIGNED AND SEALED BY THE | | ARCHITECT, NEED BOTH PLANS SIGNED AND SEALED, PER FAC | | 61G1-16.003. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2008-07-15 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-15 |
Time |
16:18 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2008-07-15 |
Time |
16:18 |
Sent To |
|
|
Notes |
2008-07-15 16:19:25 | REVISION TO MECH. PLAN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2008-07-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-03 |
Time |
14:10 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-07-03 |
Time |
14:10 |
Sent To |
|
|
Notes |
2008-07-03 14:36:05 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | REVISION TO MECHANICAL PLAN | | *** DENIED *** | | | | 1) REVISED MECHANICAL PLAN NEEDS TO BE SIGNED AND | | SEALED BY THE ENGINEER (JAMES MINGES), PER FAC | | 61G1-16.003. | | | | 2) PROVIDE FOR RETURN AIR TO THE THREE BEDROOMS, PER | | 2004 FBC/R M1602.4. | | | | 3) EQUIPMENT SCHEDULE SHOWS THE SYSTEM AS A 12 SEER, | | PER 2004 FBC 13-607.1.ABC.3.2.1 THE MINIMUM SEER IS 13. | | PLEASE CORRECT. | | | | 4) THE SUITE NUMBERFOR THIS UNIT IS 103 ACCORDING TO | | CITY RECORDS, PLANS SHOW THE SUITE NUMBER CHANGED TO | | 203. PLEASE CORRECT. | | | | 5) PLAN SHOWS ONE 8" SUPPLY AIR DUCT FEEDING TWO 8" | | DUCTS AND THREE 4" DUCTS. THIS DESIGN DOES NOT COMPLY | | WITH ACCA MANUAL D STANDARDS, PLEASE CORRECT OR SUBMIT | | YOUR MANUAL D CALCULATIONS, PER 2004 FBC/R M1601.1. | | | | 6) PLEASE SHOW THE SIZES OF ALL GRILLS ON THE | | MECHANICAL PLAN, PER 2004 WPB AMEND. 106.3.5.4 (10). | | | | 7) SHOW THE SIZE OF THE MAIN SUPPLY AIR TRUNK LINE ON | | THE MECHANICAL PLAN, PER 2004 WPB AMEND. 106.5.4.3 | | (10). | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2008-04-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-04-16 |
Time |
14:00 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2008-04-16 |
Time |
14:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-03-12 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-03-12 |
Time |
09:55 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-03-12 |
Time |
09:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-01-18 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-01-18 |
Time |
14:47 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2008-01-18 |
Time |
14:47 |
Sent To |
|
|
Notes |
2008-01-18 14:47:44 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) THE NAME IN THE TITLE BLOCK "BLUE MINGES ARCHITECT" | | IS A FICTITIOUS NAME AND AS A FIRMS NAME WOULD REQUIRE | | A CERTIFICATE OF AUTHORIZATION, SEE F.S. 481.219 (2). | | PLEASE CORRECT. | | | | 2) PLEASE SHOW THE RETURN DUCT (FLEX) AND SIZE TO BED | | #1 AND BED #2, SEE 2004 FBC 106.3.5. | | | | 3) THE RETURN AIR GRILL IN BED #3 IS SHOWN AS A SUPPLY | | GRILL, PLEASE CORRECT. | | | | 4) PERMIT APPLICATION IS MISSING FROM PLANS, PLEASE | | SUBMIT A PERMIT APPLICATION WITH CONTRACTOR SIGNED ON. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2008-01-23 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-01-23 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-01-23 |
Time |
15:23 |
Sent To |
|
|
Notes |
2008-01-23 15:23:30 | *ZONING REVIEW NOT REQUIRED - CONDO UNIT |
|
|