Plan Review Stops For Permit 07100231 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-11-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-11-20 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-11-20 |
Time |
10:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-10-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-10-22 |
Time |
17:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-10-22 |
Time |
17:16 |
Sent To |
|
|
Notes |
2007-10-22 17:16:55 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)PLEASE REVISE PLAN TO SHOW HOW COMPLIANCE WITH FBC | | R 4101.17 WILL BE MET (POOL SAFETY). |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2007-10-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-10-12 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-10-12 |
Time |
16:48 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2007-10-19 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-10-19 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-10-19 |
Time |
13:46 |
Sent To |
B |
|
Notes |
2007-10-19 13:47:04 | NOTE: THERE IS NO POOL HEATER GAS OR ELECTRIC. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2007-11-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-11-27 |
Time |
17:52 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-11-27 |
Time |
17:52 |
Sent To |
|
|
Notes |
2007-11-27 17:52:52 | HISTORICAL APPROVAL PER GALINA JUDGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-11-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-15 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-15 |
Time |
11:58 |
Sent To |
Z |
|
Notes |
2007-11-15 11:58:53 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-10-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-10-22 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-10-10 |
Time |
08:28 |
Sent To |
|
|
Notes |
2007-10-10 08:28:17 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2007-10-19 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-10-19 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-10-19 |
Time |
13:45 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-11-19 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-11-19 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-11-19 |
Time |
13:57 |
Sent To |
B |
|
Notes |
2007-11-19 13:58:09 | ***APPROVED - RESUB #1*** | | | | | | SENT TO "B" - SH |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-10-12 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-10-12 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-10-12 |
Time |
14:15 |
Sent To |
E |
|
Notes |
2007-10-12 14:24:53 | ***FAILED*** | | | | | | 1)AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT | | FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT | | SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO | | THE MINIMUM STANDARDS PROVIDED BELOW. | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B)+(C): | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | HEIGHT ABOVE GRADE. | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | 2)INDICATE POOL EQUIPMENT SETBACK DIMENSIONS TO THE | | PROPERTY LINES.NOTE: MAY NOT ENCROACH MORE THAN 4' | | INTO A REQUIRED SETBACK. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|