2008-03-25 14:12:28 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-03-17 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-03-17 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2008-03-17 |
Time |
14:44 |
Sent To |
|
|
Notes |
2008-03-17 14:44:14 | TO "M" BOX/REV |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-03-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-03-25 |
Time |
16:04 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2008-03-25 |
Time |
16:04 |
Sent To |
|
|
Notes |
2008-03-25 16:06:59 | ** MECHANICAL REVISION ** | | SCOPE OF WORK CHANGED TO INCLUDE DUCT WORK. PLANS | | SUBMITTED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-03-17 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-03-17 |
Time |
16:24 |
Rev Time |
0.35 |
Received By |
tgordon |
Date |
2008-03-17 |
Time |
16:24 |
Sent To |
|
|
Notes |
2008-03-17 16:45:25 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) SEE YELLOW HIGH LIGHT ON PLANS SHOWING TWO SUPPLY | | AIR DUCTS THAT NEED TO BE SIZED, PER 2004 FBC 106.3.5. | | | | 2) PLEASE ADD AN A/C EQUIPMENT SCHEDULE TO THE PLAN AS | | THE ORIGINAL PERMIT APPLICATION WAS FOR A 1.0 TON A/C | | UNIT, SEE ATTACHED COPY OF APPLICATION. | | | | 3) PLEASE SHOW THE CFM'S AT ALL SUPPLY AIR GRILLS. | | | | 4) SHOW ON PLAN HOW THE AIR IS RETURNING TO THE UNIT, | | IF EXISTING PLEASE STATE SO ON PLAN. | | | | 5) ADD OUT-SIDE AIR CALCULATIONS TO PLAN, PER 2004 | | FBC/M 403.2. | | | | 6) AS THE SCOPE OF WORK HAS CHANGED PLEASE ADJUST THE | | VALUE TO THE PERMIT TO SHOW ALL THE EXTRA WORK BEING | | DONE, PLEASE BE AWARE IF THE VALUE IS NOT THE | | REPLACEMENT VALUE FOR ALL THE LABOR AND MATERIALS THE | | CITY WILL NEED TO ADJUST IT, PER 2004 W./P.B AMEND. | | 108.3. | | | | 7) A NOTICE OF COMMENCEMENT WILL NEED TO BE FILED DUE | | TO THE INCREASE IN VALUE, PER F. S. 713.13 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
|