Plan Review Details - Permit 07100032
Plan Review Stops For Permit 07100032
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-04-22 Cont ID  
Sent By mjacobs Date 2008-04-22 Time 11:17 Rev Time 0.00
Received By mjacobs Date 2008-04-22 Time 10:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-12-13 Cont ID  
Sent By mjacobs Date 2007-12-13 Time 07:37 Rev Time 0.00
Received By mjacobs Date 2007-12-13 Time 06:19 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-10-11 Cont ID  
Sent By mjacobs Date 2007-10-11 Time 10:55 Rev Time 0.00
Received By mjacobs Date 2007-10-11 Time 08:37 Sent To  
Notes
2007-10-11 10:55:55 
 BUILDING PLAN REVIEW
 PERMIT: 07100032
 ADD: 301 N. OLIVE AVE 6TH FLOOR
 CONT: H.A. CONTRACTING CORP.
 TEL: (305)591-9212
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
 10/11/07
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 1B) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 2)2004 FBC EXISTING
 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
  
 3)110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION
 THAT IS REQUIRED FOR RECORD KEEPING
 A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT IS
 DESIGNED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE
 PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6,
 TABLE 601.
 D) THE OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED
 4)TABLE 601. THE EXTERIOR WALL OF THE BUILDING SHALL
 BE OF NON-COMBUSTIBLE MATERIALS. PLYWOOD IS CONSIDERED
 COMBUSTIBLE THEREFORE; DIFFERENT MATERIAL SHALL BE USE
 ON THE EXTERIOR WALL COVERING OF THE METAL STUDS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-04-25 Cont ID  
Sent By mwennerg Date 2008-04-25 Time 15:26 Rev Time 0.00
Received By mwennerg Date 2008-04-25 Time 15:26 Sent To  
Notes
2008-04-25 15:27:45REVISION DATED 4/14/08

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-12-12 Cont ID  
Sent By mawillia Date 2007-12-12 Time 18:47 Rev Time 0.00
Received By mawillia Date 2007-12-12 Time 18:38 Sent To B1
Notes
2007-12-12 18:44:34*****APPROVED*****
  
  
 PLAN SHEET BP-1 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-10-15 Cont ID  
Sent By mawillia Date 2007-10-15 Time 12:33 Rev Time 0.00
Received By mawillia Date 2007-10-15 Time 12:14 Sent To  
Notes
2007-10-15 12:32:56*****UNSAT*****
  
  
 PLEASE INDICATE IF THIS WALL OPENING IS REQUIRED TO
 HAVE FIRE PROTECTION RATING.IF SO, PROVIDE RATING FOR
 THE NEW DOORS AND ASSEMBLY IN ACCORDANCE WITH NFPA 80,
 STANDARD FOR FIRE DOORS AND FIRE WINDOWS
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-04-16 Cont ID  
Sent By adarroug Date 2008-04-16 Time 16:13 Rev Time 0.00
Received By adarroug Date 2008-04-16 Time 16:13 Sent To  
Notes
2008-04-16 16:14:02TO "BOB"#4

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-11-30 Cont ID  
Sent By adarroug Date 2007-11-30 Time 15:43 Rev Time 0.00
Received By adarroug Date 2007-11-30 Time 15:43 Sent To  
Notes
2007-12-06 08:22:51TO "BOB"#6
2007-11-30 15:43:34WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-10-15 Cont ID  
Sent By mawillia Date 2007-10-15 Time 12:36 Rev Time 0.00
Received By mawillia Date 2007-10-02 Time 11:50 Sent To  
Notes
2007-10-05 15:27:36TO "BOB"#14
2007-10-02 11:55:55WAITING FOR "BOB"

Review Stop Z ZONING
Rev No 1 Status N Date 2008-04-24 Cont ID  
Sent By choops Date 2008-04-24 Time 10:58 Rev Time 0.00
Received By choops Date 2008-04-24 Time 10:58 Sent To  
Notes
2008-04-24 10:58:33*ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE
 VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.