Plan Review Details - Permit 07090854
Plan Review Stops For Permit 07090854
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-12-13 Cont ID  
Sent By shill Date 2007-12-13 Time 17:21 Rev Time 0.00
Received By shill Date 2007-12-13 Time 17:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-10-30 Cont ID  
Sent By shill Date 2007-10-29 Time 16:34 Rev Time 0.00
Received By shill Date 2007-10-29 Time 16:34 Sent To  
Notes
2007-10-30 09:03:01****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.ALL DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS FS471.
  
 2.INCLUDE 2007 AMENDMENTS IN GOVERNING CODE.
  
 3.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED IN
 ADDITION TO THE EVALUATION REPORT, FAC9B72.PRINT TWO
 SETS OF EACH EVALUATION REPORT AND ALSO THE FLORIDA
 STATE PRODUCT APPROVAL, IF AVAILABLE.IF A FLORIDA
 STATE PRODUCT APPROVAL IS NOT AVAILABLE, PLEASE ADVISE
 AND A LOCAL PRODUCT APPROVAL MAY BE ISSUED USING THE
 NOA.FOR THE EAGLE METAL TRUSS PLATE, IF A FLORIDA
 STATE PRODUCT APPROVAL IS NOT AVAILABLE, THE
 MANUFACTURER WILL BE REQUIRED TO APPLY FOR LOCAL
 PRODUCT APPROVAL. WWW.FLORIDABUILDING.ORG
  
 4.SHEATHING DOES NOT MEET THE MINIMUM REQUIREMENTS OF
 TABLE FBC2304.7(3); NO EDGE SUPPORTS.
  
 5.SEE FBC802.2.THE PLAN STATES THAT THIS DESIGN IS
 COMPLIANT FOR 150 EXPOSURE D, BUT DOES NOT USE
 CONSTRUCTION METHODS TYPICAL OF THIS AREA (LACKS RIDGE
 BOARD, NO RESISTANCE TO RAFTER THRUST IN THE WAY OF
 COLLAR TIES OR CEILING JOISTS).PROVIDE DESIGN
 INFORMATIONOR CALCULATIONS FOR ALL CONNECTIONS, ROOF
 RAFTER AT TOP PLATE (SHOWS A NOTCHED 2X4), 7/16
 SHEATHING AS MWRS, RESISTANCE TO RAFTER THRUST, LACK OF
 COLLAR TIES OR CEILING JOISTS, ETC.IT IS NOT CLEAR
 HOW THE ROOF SYSTEM WILL RESIST WIND UPLIFT AND LATERAL
 LOADS.PLEASE SEE ASCE7-02.A SET HAS BEEN RETAINED.
  
  
 6.SPECIFY SIDING FBC23, FBC*106.
  
 7.ON THE PLAN, SHOW MINIMUM DIMENSION OF THE NOTCHED
 2X4 AT THE WALL TOP PLATE BEARING POINT.
  
 8.AN 8 1/2 X 11 DETAIL FOR STEEL FLOOR AND ANCHORS
 DETAIL WAS PROVIDED.IF YOU WISH TO USE THIS ALTERNATE
 DETAIL, REMOVE THE CONFLICTING INFORMATION FROM THE
 PLAN (THIS MAY BE CROSSED OFF) AND THE ALTERNATE DETAIL
 IS REQUIRED TO BE A SIGNED, SEALED, DATED ORIGINAL
 FAC61G15-23.002.TWO ORIGINAL SETS REQUIRED.
  
 9.CERTIFICATE OF AUTHORIZATION REQUIRED TO PRACTICE
 ENGINEERING THROUGH A COMPANY, FS471.023.
  
 10.ALL INFORMATION REQUIRED BY FAC61G15-23.002
 REQUIRED ON EACH SHEET (CERTIFICATE OF AUTHORIZATION).
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-12-03 Cont ID  
Sent By adarroug Date 2007-12-03 Time 15:25 Rev Time 0.00
Received By adarroug Date 2007-12-03 Time 15:25 Sent To B
Notes
2007-12-03 15:25:45TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-10-30 Cont ID  
Sent By shill Date 2007-10-30 Time 09:03 Rev Time 0.00
Received By shill Date 2007-10-01 Time 11:03 Sent To  
Notes
2007-10-01 11:04:06TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2007-10-04 Cont ID  
Sent By choops Date 2007-10-04 Time 09:48 Rev Time 0.00
Received By choops Date 2007-10-04 Time 09:48 Sent To B
Notes
***NONE***