Plan Review Details - Permit 07090797
Plan Review Stops For Permit 07090797
Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-04-14 Cont ID  
Sent By adarroug Date 2008-04-14 Time 15:46 Rev Time 0.00
Received By adarroug Date 2008-04-14 Time 15:46 Sent To P
Notes
2008-04-14 15:46:31TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-10-30 Cont ID  
Sent By adarroug Date 2007-10-30 Time 12:33 Rev Time 0.00
Received By adarroug Date 2007-10-30 Time 12:32 Sent To P
Notes
2007-10-30 12:33:17TO "P" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-10-11 Cont ID  
Sent By adarroug Date 2007-10-11 Time 12:26 Rev Time 0.00
Received By adarroug Date 2007-10-11 Time 12:26 Sent To P
Notes
2007-10-11 12:27:08TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-10-10 Cont ID  
Sent By mperson Date 2007-10-10 Time 14:37 Rev Time 0.00
Received By mperson Date 2007-09-28 Time 13:57 Sent To  
Notes
2007-09-28 13:57:28TO "P" BOX

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-04-15 Cont ID  
Sent By mperson Date 2008-04-15 Time 16:33 Rev Time 0.00
Received By mperson Date 2008-04-15 Time 16:32 Sent To PC
Notes
2008-04-15 16:34:59REVISION: SUBMITTED NEW ISOMETRIC SANITARY RISER
 DIAGRAM INDICATING REPLACEMENT OF EXISTING CAST IRON
 PIPE WITH NEW PVC PIPE.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-11-07 Cont ID  
Sent By mperson Date 2007-11-07 Time 09:42 Rev Time 0.00
Received By mperson Date 2007-11-07 Time 09:42 Sent To PC
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-10-23 Cont ID  
Sent By mperson Date 2007-10-23 Time 15:14 Rev Time 0.00
Received By mperson Date 2007-10-23 Time 15:14 Sent To PC
Notes
2007-10-23 15:41:16DENIED 2ND TIME
 REFERENCE:
 ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FBC-2004 WITH 06 REVISIONS CHAPTER 11, FLORIDA
 ACCESSIBILITY CODE.
 ** FLORIDA ADMINISTRATIVE CODE (FAC).
 ** FLORIDA STATUTES (FS).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE ON THE
 RESUBMITTED PLANS:
  
 1. THE RESUBMITTED PLANS DO NOT REFLECT EVERYTHING ON
 THE PERMIT APPLCATION. PERMIT APPLICATION STATES
 "REMOVE & INSTALL JACUZZI TUB WITH FIXTURES". THE
 RESUBMITTED PLANS DO NOT INDICATE THIS WORK BEING DONE.
 PER FBC-2004 CHAPTER 1, SECTION 106.1.2 ADDITIONAL
 INFORMATION REQUIRED.
  
 2. THE RESUBMITTED SANITARY ISOMETRIC RISER DIAGRAMS
 ARE INDICATING A WASTE STACK FOR A 2ND FLOOR WASHING
 MACHINE BOX. THE PERMIT APPLICATION DOES NOT INDICATE
 THIS WORK BEING DONE.
 NOTE: THE PERMIT APPLICATION STATES "DESCRIBE PROJECT
 IN DETAIL (FAILURE TO DO SO MAY RESULT IN DELAYS). PER
 FBC-2004 CHAPTER 1 SECTION 105 PERMITS, AND 106.1.2
 ADDITIONAL INFORMATION REQUIRED.
  
 3. FBC-2004 CHAPTER 1,SECTION 106.3.4.3:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME, AND ALSO DATE DRAWING. PLEASE DO
 THIS PRIOR TO RESUBMITTING.
 NOTE: THE RESUBMITTED FLOOR PLAN DRAWINGS ARE NOT
 COMPLIANT.
  
 4. PER FC 713.13 (1) THRU (6): A NOTICE OF
 COMMENCEMENT IS REQUIRED FROM THE - PALM BEACH COUNTY
 COURTHOUSE - 4TH FLOOR RECORDING DEPT. 205 N. DIXIE
 HWY., BEFORE A PERMIT CAN BE ISSUED.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-10-10 Cont ID  
Sent By mperson Date 2007-10-10 Time 14:16 Rev Time 0.00
Received By mperson Date 2007-10-10 Time 14:16 Sent To PC
Notes
2007-10-10 14:37:00DENIED
 REFERENCE:
 ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FBC-2004 WITH 06 REVISIONS CHAPTER 11, FLORIDA
 ACCESSIBILITY CODE.
 ** FLORIDA ADMINISTRATIVE CODE (FAC).
 ** FLORIDA STATUTES (FS).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 GAS/PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. 1. MORE INFORMATION IS REQUIRED DUE TO THE FACT
 THAT A PLUMBING PERMIT IS BEING APPLIED FOR. PLEASE
 PROVIDE THE FOLLOWING INFORMATION IF IT PERTAINS TO
 YOUR JOB.
  
 A} IF PLUMBING LAYOUT IS THE SAME WITH NO CHANGES,
 PLEASE INDICATE THIS ON THE RESUBMITTED DRAWINGS.
  
 B} IF PLUMBING LAYOUT IS THE SAME AND THE PLUMBING
 FIXTURES ARE TO BE CHANGED, PLEASE INDICATE ON THE
 RESUBMITTED DRAWINGS. "EXACT FIXTURE CHANGEOUT ONLY"
 AND CLEARLY INDICATE WHAT FIXTURES ARE GOING TO BE
 CHANGED.
  
 C} IF THE NEW PROPOSED PLUMBING LAYOUT IS DIFFERENT
 FROM THE EXISTING PLEASE SUBMIT THE FOLLOWING ON
 SEPERATE DRAWINGS.
 A) EXISTING FLOOR PLAN LAYOUT.
 B) NEW PROPOSED FLOOR PLAN LAYOUT AND PLEASE FOLLOW
 WHAT IS REQUIRED IN COMMENT #2.
  
 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4
 RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A
 PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING
 ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT
 LOCATIONS.
  
 3. PER FBC-2004 CHAPTER 1, SECTION
 106.1 SUBMITTAL DOCUMENTS. CONSTRUCTION
 DOCUMENTS, SPECIAL INSPECTION AND
 STRUCTURAL OBSERVATION PROGRAMS, AND
 OTHER DATA SHALL BE SUBMITTED IN TWO OR
 MORE SETS WITH EACH APPLICATION FOR A
 PERMIT.
 NOTE: ONLY ONE SET OF DRAWING WAS SUBMITTED.
  
 4. AT A MINIMUM THE PLANS MUST CLEARLY REFLECT WHAT IS
 ON THE PERMIT APPLICATION. THE SUBMITTED PLANS DO NOT
 DO THIS. PER FBC-2004 CHAPTER 1, SECTION 106.1.1
 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE
 BUILDING OFFICIAL.
  
 5. FBC-2004 CHAPTER 1,SECTION 106.3.4.3:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME, AND ALSO DATE DRAWING. PLEASE DO
 THIS PRIOR TO RESUBMITTING.
  
 6. PER FC 713.13 (1) THRU (6): A NOTICE OF
 COMMENCEMENT IS REQUIRED FROM THE - PALM BEACH COUNTY
 COURTHOUSE - 4TH FLOOR RECORDING DEPT. 205 N. DIXIE
 HWY., BEFORE A PERMIT CAN BE ISSUED.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved