Plan Review Stops For Permit 07090639 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-03-22 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-03-22 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-03-22 |
Time |
12:26 |
Sent To |
PC |
|
Notes |
2008-03-22 12:27:52 | | | | | PASSED BLDG REVISION FOR CANGE OF PRODUCT APPROVAL FOR | | WINDOWS AND DOOR |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-02-05 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-02-05 |
Time |
18:13 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-02-05 |
Time |
18:13 |
Sent To |
PC |
|
Notes |
2008-02-05 18:14:35 | | | | | REVISION/SUBMITTAL OF TRUSS DRAWINGS OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-12-22 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-12-22 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-12-22 |
Time |
12:39 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-12-13 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-12-13 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-12-13 |
Time |
16:47 |
Sent To |
PC |
|
Notes |
2007-12-13 16:56:59 | | | | | | | DENIED | | THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM THE | | FIRST REVIEW: | | | | 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | PER 108.3 FBC* | | | | *********NOTE: FEES ARE DUE IN THE AMOUNT OF $165.85 | | FOR INCREASED VALUE THIS AMOUNT IS REQUIRED TO BE PAID | | PRIOR TO FURTHER PLAN REVIEW******* | | | | 6)PROVIDE SCHEDULE ON DRAWINGS FOR DOOR AND WINDOW | | SIZES/DIMENSIONS, TYPES AND DESIGN PRESSURES | | | | ********NO WINDOW SIZE WAS GIVEN TO THE FIXED WINDOW | | (MARK "A") AND NO PRODUCT APPROVALS WERE SUBMITTED FOR | | FIXED WINDOW UNIT(S)******** | | | | 10)PROVIDE 2 COPIES OF A COMPLETED SHUTTER | | INSTALLATION SCHEDULE WITH MOUNTING TYPE FOR THE TOP | | AND BOTTOM, PANEL ORIENTATION (HORZ ORVERT), FASTENER | | TYPE ETC. FILLED OUT SEE ATTACHED SCHEDULE EXAMPLE | | | | *******NOTE, THE INFORMATION FOR THE SHUTTER SCHEDULE | | IS FOUND IN THE PRODUCT APPROVAL******* | | | | 14)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-10-20 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-10-20 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-10-20 |
Time |
16:47 |
Sent To |
PC |
|
Notes |
2007-10-20 17:07:19 | | | | | DENIED | | | | 1)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING | | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF | | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND | | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE | | DRAWINGS | | | | 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | PER 108.3 FBC* | | | | 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON | | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER | | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE | | ADDED TO THE PERMIT APPLICATION FEES | | | | NOTE: FEES ARE DUE IN THE AMOUNT OF $165.85 FOR | | INCREASED VALUE THIS AMOUNT IS REQUIRED TO BE PAID | | PRIOR TO FURTHER PLAN REVIEW | | | | 4)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER | | AND OWNER/AGENT PRIOR | | TO SUBMITTAL. CALC'S ARE NOT SIGNED BY OWNER/AGENT AND | | ADDITIONS OR REMODELS REQUIRE A MIN R5 INSULATION AT | | EXTERIOR BLOCK WALLS AND MIN R30 IN CEILINGS WITH ATTIC | | SPACE PER 13-602.1.C.1.2 & 13-602.1.C.2 FBC FOR WALLS | | AND 13-604.1.C.1 & 13-604.1.C.2 FBC FOR CEILINGS | | | | 5)PROVIDE AT MINIMUM 1 ACCESSIBLE BATHROOM PER | | R322.1.1 FBC 29" CLEAR WITH DOOR OPEN 90 DEGREES | | | | 6)PROVIDE SCHEDULE ON DRAWINGS FOR DOOR AND WINDOW | | SIZES/DIMENSIONS, TYPES AND DESIGN PRESSURES | | | | 7)PROVIDE THE FOLLOWING CORRECTIONS TO SHEET A/1 | | CORRECT DIMENSIONS FOR EAST ELEVATION AS THEY ADD UP TO | | 26'-1", WINDOW AND DOOR DESIGN PRESSURES,CORRECT | | R-VALUES AND 3 BEDROOM WINDOWS SHOW MULLIONS IF SO | | PRODUCT APPROVALS WILL BE REQUIRED. PLEASE BE SURE THAT | | THEY WILL MEET EMERGENCY EGRESS IF MULLIONS ARE USED. | | | | 8)PROVIDE PRODUCT APPROVALS FOR SIMPSON | | STRAPS/CONNECTORS OR INCLUDE THE CORRECT FLORIDA | | PRODUCT APPROVAL #'S ON THE SIMPSON SCHEDULE ON S/1 OR | | PROVIDE SIMPSON'S FLORIDA APPROVED INDEX (ON SIMPSON | | TIE WEB SITE) AND MARK/HIGHLIGHT THE CONNECTORS THAT | | WILL BE USED | | | | 9)GAF GRAND TIMBERLINE SHINGLES ARE NOT LISTED UNDER | | THE FLORIDA APPROVAL #183, REMOVE THE STATE COVER AND | | APPROVE THE MIAMI-DADE REPORT THAT HAS BEEN ACCEPTED | | FOR LOCAL PRODUCT APPROVAL | | | | 10)PROVIDE 2 COPIES OF A COMPLETED SHUTTER | | INSTALLATION SCHEDULE WITH MOUNTING TYPE FOR THE TOP | | AND BOTTOM, PANEL ORIENTATION (HORZ ORVERT), FASTENER | | TYPE ETC. FILLED OUT SEE ATTACHED SCHEDULE EXAMPLE | | | | 11)PROVIDE SYSTEM THAT WILL BE USED FOR MODIFIED | | BITUMEN ROOF FROM THE MANY LISTED IN THE PRODUCT | | APPROVAL, ALSO PROVIDE CALCULATIONS FOR THE INCREASED | | FASTENERS REQUIRED FOR THE PERIMETER AND CORNER ZONES | | PER RAS 117 (SEE LIMITATION #7 ON PAGE 32) | | | | 12)SUBMIT 2 SIGNED AND SEALED ENGINEERED TRUSS | | DRAWINGS THAT COMPLY WITH R802.10.1 FBC WITH PERMIT | | APPLICATION OR BEFORE INSTALLATION THAT HAVE BEEN | | REVIEWED AND APPROVED BY THE DESIGNER OF RECORD | | | | 13)NOTE THAT SCOPE OF WORK DOES NOT COVER REPLACEMENT | | OF PLUMBING PIPING AND WAS REVIEW AS ONLY FIXTURE | | REPLACEMENT IF PIPING WAS DAMAGED AND REQUIRES ANY WORK | | STATE ON THE DRAWINGS AND PROVIDE RISER DIAGRAM FOR | | COMPLETE PLUMBING REVIEW | | | | 14)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-11-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-11-28 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-11-28 |
Time |
14:52 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-09-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-09-25 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-09-25 |
Time |
07:25 |
Sent To |
Z |
|
Notes |
2007-09-25 08:26:53 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | | | ALL COMMENTS RELATE TO SHEET E-1, UNLESS OTHERWISE | | NOTED. ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS | | OTHERWISE NOTED. | | | | 1} INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE PLAN | | IS NEW OR EXISTING. IF NEW , PROVIDE AN AIC RATING, AND | | LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, METER | | ENCLOSURE, DISCONNECTS AND PANELS, SO THAT COMPLIANCE | | WITH ARTICLES 225 AND 230 CAN BE REVIEWED. PROVIDE A | | RISER DIAGRAM WITH CONDUCTOR AND CONDUIT SIZE AND | | TYPE. | | | | 2} NOTE #20 REQUIRES # 12 CONDUCTORS MINIMUM FOR THIS | | PROJECT. THERE ARE #14 CONDUCTORS ON THE PANEL | | SCHEDULE, CLARIFY TO AVOID CONFUSION DURING | | CONSTRUCTION. 106.1.3. | | | | 3} THE NOTE IN THE PANEL SCHEDULE INDICATES THE PANEL | | IS LOCATED IN THE GARAGE, THERE IS NO GARAGE ON THE | | FLOOR PLAN. THERE IS A CARPORT SHOWN ON THE SURVEY. | | CLARIFY ALL EQUIPMENT LOCATIONS.106.1.3. | | | | 4} THERE ARE TWO "BATH CIRCUITS" LISTED IN THE | | SCHEDULE, ONE, CIRCUIT# 22, IS ON A 15 AMP BREAKER. | | THAT CIRCUIT COULD NOT BE USED FOR THE REQUIRED GFCI AS | | 210.11(C)(3) REQUIRES A 20 AMP CIRCUIT.PER 408.4, "THE | | IDENTIFICATION SHALL INCLUDE SUFFICIENT DETAIL TO ALLOW | | EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS." | | CLARIFY CIRCUIT DESIGNATIONS. | | | | 5} THE KITCHEN COUNTERTOP RECEPTACLE ADJACENT TO THE | | PENINSULAR MUST BE GFCI PER 210.8(A)(6), INDICATE SAME | | ON THE PLAN. | | | | 6} A RECEPTACLE IS REQUIRED AT THE FRONT OF THE | | RESIDENCE PER 210.52(E). | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2008-07-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-30 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-30 |
Time |
09:18 |
Sent To |
M |
|
Notes |
2008-07-30 09:18:24 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2008-07-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-17 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-17 |
Time |
15:59 |
Sent To |
M |
|
Notes |
2008-07-17 16:00:18 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-07-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-10 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-10 |
Time |
10:07 |
Sent To |
M |
|
Notes |
2008-07-10 10:08:03 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-03-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-20 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-20 |
Time |
14:38 |
Sent To |
B |
|
Notes |
2008-03-20 14:40:11 | TO "AMORSE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-02-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-01 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-01 |
Time |
16:59 |
Sent To |
B |
|
Notes |
2008-02-01 16:59:52 | TO "AMORSE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-12-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-12-19 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-12-19 |
Time |
17:18 |
Sent To |
Z |
|
Notes |
2007-12-19 17:18:34 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-11-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-19 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-19 |
Time |
11:47 |
Sent To |
Z |
|
Notes |
2007-11-19 11:47:26 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-10-20 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-24 |
Time |
11:29 |
Sent To |
|
|
Notes |
2007-09-24 11:29:36 | TO "E" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2008-07-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-30 |
Time |
13:48 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-07-30 |
Time |
13:48 |
Sent To |
|
|
Notes |
2008-07-30 13:48:48 | REVISION TO MECH. PLAN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2008-07-18 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-18 |
Time |
09:07 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2008-07-18 |
Time |
09:07 |
Sent To |
|
|
Notes |
2008-07-18 09:08:27 | REVISION TO MECH. PLAN AND COOLING LOAD CAL'S. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2008-07-10 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-10 |
Time |
14:04 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-07-10 |
Time |
14:04 |
Sent To |
|
|
Notes |
2008-07-10 14:14:06 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | ** REVISION TO MECHANICAL PLAN ** | | *** DENIED *** | | | | 1)A/C SYSTEM MODEL NUMBERS LISTED ON THE A/C | | EQUIPMENT SCHEDULE COULD NOT BE FOUND ON THE ARI | | DIRECTORY WEB-SITE, PLEASE CORRECT OR SUBMIT AN ARI | | CERTIFICATE, SEE 2004 FBC 13-607.1.ABC.3.1.1. | | | | 2) INFORMATION IN THE EQUIPMENT SCHEDULE IS INCORRECT | | (SEE YELLOW HIGH LIGHT ON PLAN). PLEASE CORRECT PER | | 2004 FBC 106.1.1. | | | | 3) PLEASE BE ADVISED THE CONDENSER UNIT MODEL NUMBER ON | | THE PLAN APPEARS TO BE DISCONTINUED BY THE ARI, IF SO | | PLEASE CORRECT PER 2004 FBC 13-607.1.ABC.3.1.1. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-11-29 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-11-29 |
Time |
08:30 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-11-29 |
Time |
08:30 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-10-11 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-10-11 |
Time |
09:37 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2007-10-11 |
Time |
09:37 |
Sent To |
B |
|
Notes |
2007-10-11 10:00:22 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) ENERGY CALCULATIONS LINE 9A-1 SHOWS R4.2, SEE SECOND | | PAGE OF E-CAL'S TABLE 6C-1 MINIMUM FOR CONCRETE BLOCK | | IS R-5, ALSO SEE 2004 FBC 13-602.1.C.2, PLEASE | | CORRECT. | | | | 2) ENERGY CALCULATIONS LINE 10A SHOWS R19, SEE SECOND | | PAGE OF E-CAL'S TABLE 6C-1 MINIMUM FOR ATTIC IS R-30, | | ALSO SEE 2004 FBC 13-604.1.C.2, PLEASE CORRECT. | | | | 3) THE ENERGY CALCULATIONS NEED TO BE SIGNED BY THE | | PREPARER (NELSON MARIN) AND ALSO BY THE OWNER/AGENT, | | SEE 2004 FBC'S 13-103.1.1 AND 13-600.ABC.2. | | | | 4) PLEASE CORRECT PLANS PAGE A-1 TO SHOW CORRECTED | | MINIMUM INSULATION VALUES AS STATED ABOVE. | | | | 5) MECHANICAL PLAN PAGE M-1 NEEDS TO BE SEALED BY THE | | ENGINEER LUIS A. LOPEZ AS HIS INFORMATION IS IN THE | | TITLE BLOCK, SEE FAC 61G15-23.002. | | | | 6) PLEASE SHOW THE LOCATION OF CONDENSER UNIT #2 ON | | MECHANICAL PLAN PAGE M-1. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2007-10-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-10-04 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-10-04 |
Time |
09:21 |
Sent To |
M |
|
Notes |
2007-10-04 09:23:02 | PLUMBING FIXTURE CHANGE OUT ONLY |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-12-21 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-12-21 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-12-21 |
Time |
14:30 |
Sent To |
B |
|
Notes |
2007-12-21 14:31:32 | ***APPROVED - RESUB #2*** | | | | | | | | | | SENT TO "B" - AM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-11-28 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-11-28 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-11-28 |
Time |
10:26 |
Sent To |
E |
|
Notes |
2007-11-28 10:26:58 | ***FAILED - RESUB #1*** | | | | | | REPEAT COMMENT: | | | | 1)LANDSCAPE PLANS SUBMITTED ARE INSUFFICIENT.PLANS | | SHALL SHOW EXISTING/PROPOSED.PLANS SHALL SHOW | | COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE | | ZONING AND LAND DEVELOPMENT REGULATIONS. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-09-26 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-09-26 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-09-26 |
Time |
13:12 |
Sent To |
M |
|
Notes |
2007-09-26 13:14:51 | ***FAILED*** | | | | | | 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY | | SHOWING THE SCOPE OF WORK WITH SETBACK DIMENSIONS TO | | ALL PROPERTY LINES. | | | | 2)AS THE PROPOSED RENOVATION EXCEEDS 50% OF THE | | IMPROVEMENT VALUE OF THE HOME, LANDSCAPING SHALL BE | | BROUGHT TO COMPLIANCE WITH SECTION 94-442 OF THE ZONING | | AND LAND DEVELOPMENT REGULATIONS(ZLDRS), PURSUANT TO | | SECTION 94-441(C) OF THE ZLDRS.PLEASE PROVIDE A | | LANDSCAPE PLAN SHOWING COMPLIANCE. | | | | 3)INDICATE OVERHANG DIMENSIONS OF PROPOSED ROOF. | | | | 4)PROVIDE SETBACK DIMENSIONS FROM PROPOSED A/C | | EQUIPMENT TO THE PROPERTY LINES. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|