Plan Review Stops For Permit 07090553 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2008-06-13 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2008-06-13 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2007-10-23 |
Time |
08:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2009-07-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-07-20 |
Time |
12:10 |
Rev Time |
0.45 |
Received By |
jwitmer |
Date |
2009-07-20 |
Time |
11:45 |
Sent To |
PC |
|
Notes |
2009-07-20 11:51:44 | 07090553 | | REVISIONS: | | S-4 REV# 2 | | S-6 REV# 1 | | S-7 REV # 3 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2009-07-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-07-15 |
Time |
16:13 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2009-07-15 |
Time |
15:45 |
Sent To |
|
|
Notes |
2009-07-15 16:16:55 | REVISION; PRODUCT APPROVALS; | | FL 3341 | | LOUVER: NOA 08-1003.07 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-12-05 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-12-05 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-12-05 |
Time |
15:51 |
Sent To |
PC |
|
Notes |
2008-12-05 15:52:01 | PROCESS PLANS AND PRINT PERMIT . |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-11-21 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-11-21 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-11-17 |
Time |
15:44 |
Sent To |
|
|
Notes |
2008-11-17 15:45:39 | I AM WAITING FOR A FEW PRODUCT APPROVALS FROM THE | | CONTRACTOR. | | | | BUILDING PLAN REVIEW | | PERMIT: 07090553 | | ADD: 6255 N. JOG ROAD | | CONT: WEST CONSTRUCTION INC. | | TEL: (561)588-2027 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 9-5-08 | | REVIEW: 2ND | | ACTION: DENIED | | | | 1) OK | | 2) OK | | 3) OK | | 4) OK | | 5) OK | | 6) OK | | 7) OK | | 8) OK | | 9) OK | | 10) OK | | | | PROVISOR: PRIOR TO INSTALLATION. | | 11) PROVIDE THE SHOP DRAWINGS WHICH SHALL INCLUDE ALL | | ROOFING/ JOIST / ALUMINUM LADDER WITH PLATFORM AND | | STRUCTURAL DETAILS ETC. FOR THE BUILDING AS STATED ON | | SHEET S-1, S-2 AND S-5. THE DRAWINGS SHALL BE REVIEWED | | AND APPROVED BY THE DESIGNER OF RECORD. SHEET S-7 MAKES | | REFERENCE TO SEE NOTE #6 WHICH IN NOT ON THE SHEET. | | DETAIL #9 ON SHEET S-7 REQUIRES THE ENGINEERED DESIGN | | FOR THE OVERHANG. | | | | 12) OK | | NEW: (A) OK | | (B) OK | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-09-05 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-09-05 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-09-05 |
Time |
06:57 |
Sent To |
|
|
Notes |
2008-09-05 16:53:09 | BUILDING PLAN REVIEW | | PERMIT: 07090553 | | ADD: 6255 N. JOG ROAD | | CONT: WEST CONSTRUCTION INC. | | TEL: (561)588-2027 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 9-5-08 | | REVIEW: 2ND | | ACTION: DENIED | | | | 1) OK | | 2) OK | | | | RESPONSE NOTED: HOWEVER; THIS INFORMATION IS STILL | | REQUIRED. | | 3) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, PLEASE | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | REPORTS ARE AS FOLLOWS: (A) ROLL-UP DOORS (B) SHUTTERS | | (C) WINDOWS (D) INSULATED METAL ROOF PANELS (E) METAL | | WALL PANELS (F ) HOLLOW METAL DOORS (G) IMPACT GLASS | | DOOR (H) ALUMINUM LOUVERS 106.3.3* PRODUCT PPROVALS- | | 2004 THOSE PRODUCTS THAT ARE REGULATED BY DCA RULE | | 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | RESPONSE NOTED: HOWEVER; THIS INFORMATION IS STILL | | REQUIRED. | | 4) SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | 1. COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR | | PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT. | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | FAC9B72, WWW.FLORIDABUILDING.ORG. | | 3. ON THE PRODUCT APPROVAL, MARK WHICH DETAILS APPLY TO | | THIS JOB. PLEASE USE INK RATHER THAN A HIGHLIGHTER. SEE | | ADDITIONAL INFORMATION IN PACKAGE. | | | | RESPONSE NOTED: HOWEVER; THIS INFORMATION IS STILL | | REQUIRED. | | 5) ROOFING PERMIT; ONLY CHECKED ITEMS APPLY | | ____ 1) CONTRACTOR IS TO PROVIDE THE FOLLOWING | | INFORMATION, SEE ATTACHED POLICY: MEAN ROOF HEIGHT/ | | ROOF PITCH / ROOF DECK TYPE / AREA OF EACH ROOF TYPE | | ____2) FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED | | IN ADDITION TO THE EVALUATION REPORT SUBMITTED, | | FAC9B72. WWW.FLORIDABUILDING.ORG | | ____3) FOR THE FLAT DECK, SELECT THE APPROVED ASSEMBLY | | YOU ARE USING. ALSO INDICATE WHICH FASTENER IF THE | | OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS. | | ____5) FOR THE FLAT DECK, SPECIFY THE ENHANCED | | FASTENING FOR CORNER AND PERIMETER ZONES. | | ___ 6) SEE PRODUCT LIMITATION #7. CALCULATIONS PREPARED | | BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF | | CONSULTANT REQUIRED FOR ENHANCED FASTENING. | | | | | | 6) OK | | 7) OK | | 8) OK | | 9) OK | | 10) OK | | | | PROVISOR: PRIOR TO INSTALLATION. | | 11) PROVIDE THE SHOP DRAWINGS WHICH SHALL INCLUDE ALL | | ROOFING/ JOIST / ALUMINUM LADDER WITH PLATFORM AND | | STRUCTURAL DETAILS ETC. FOR THE BUILDING AS STATED ON | | SHEET S-1, S-2 AND S-5. THE DRAWINGS SHALL BE REVIEWED | | AND APPROVED BY THE DESIGNER OF RECORD. SHEET S-7 MAKES | | REFERENCE TO SEE NOTE #6 WHICH IN NOT ON THE SHEET. | | DETAIL #9 ON SHEET S-7 REQUIRES THE ENGINEERED DESIGN | | FOR THE OVERHANG. | | | | 12) OK | | | | NEW: (A) INDICATE THE R-VALUE FOR THE FOAM INSULATION | | IN THE CMU EXTERIOR WALLS. | | | | (B) THE DRAWINGS FROM NUCOR BUILDING SYSTEMS SHALL | | CONTAIN THE ORIGINAL SIGNATURE OF THE PROFESSIONAL | | ENGINEER. THE SIGNATURE ON THE SHEETS IS A PHOTO-COPY | | SIGNATURE. ALL DOCUMENTS BEING FILED FOR PUBLIC RECORD | | SHALL CONTAIN THE ORIGINAL SIGNATURE OF THE PERSON WHO | | RESPONSIBLE FOR THE DOCUMENT. A PROFESSIONAL ENGINEER | | SHALL SIGN HIS NAME AND AFFIX HIS SEAL TO ALL PLANS, | | SPECIFICATIONS, REPORTS, FINAL BID DOCUMENTS AND OTHER | | DOCUMENTS PREPARED OR ISSUED BY SAID REGISTRANT AND | | BEING FILED FOR PUBLIC RECORD. FAC 61G15-23.002 AND | | FLORIDA STATUTES 471 ALSO SEE FBC 106.1. NOTE: A COVER | | OR INDEX SHEET FOR ENGINEERING SPECIFICATIONS MAY BE | | USED AND THAT SHEET MUST BE SIGNED, SEALED AND DATED BY | | THOSE PROFESSIONAL ENGINEERS IN RESPONSIBLE CHARGE OF | | THE PRODUCTION AND PREPARATION OF EACH SECTION OF THE | | ENGINEERING SPECIFICATION, AND IF PRACTICING TROUGH A | | DULY AUTHORIZED ENGINEERING BUSINESS, THE NAME, ADDRESS | | AND CERTIFICATE OF AUTHORIZATION NUMBER OF THE | | ENGINEERING BUSINESS SHALL BE INDICATED ON THE SHEET | | WITH SUFFICIENT INFORMATION ON THE COVER SHEET OR INDEX | | SO THAT THE USER WILL BE AWARE OF EACH PORTION OF THE | | DOCUMENT. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-06-05 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-06-05 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-06-02 |
Time |
14:53 |
Sent To |
|
|
Notes |
2008-06-05 15:42:07 | BUILDING PLAN REVIEW | | PERMIT: 07090553 | | ADD: 6255 N. JOG ROAD | | CONT: WEST CONSTRUCTION INC. | | TEL: (561)588-2027 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 6-3-08 | | REVIEW: 2ST | | ACTION: DENIED | | | | 1) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | 2) SHEET LS-1 INDICATES THE OCCUPANCY AS A MIXED | | OCCUPANCY WITH A S-1 MEDIUM HAZARD SECTION. THERE IS NO | | MEDIUM HAZARD MENTION IN THE CODE, SO PLEASE CHANGE THE | | INFORMATION ON THE PLANS TO REFLECT THE CORRECT TYPE OF | | OCCUPANCY; SEE FBC 311 FOR ADDITIONAL INFORMATION. | | PROVIDE THE MSDS INFORMATION ON ALL TYPES AND QUANTITY | | OF MATERIALS WHICH WILL BE STORED OR PLACE IN THIS | | AREA. THE GROSS BUILDING AREA HAS THE NUMBER 17,500 X | | 3, WHICH TABLE DID THIS NUMBER CAME FROM FOR THE TYPE | | VB BUILDING? CLARIFY. PLEASE INDICATE THE FLOOD ZONE | | INFORMATION ON THE PLANS. | | | | 3) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, PLEASE | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | REPORTS ARE AS FOLLOWS: (A) ROLL-UP DOORS (B) SHUTTERS | | (C) WINDOWS (D) INSULATED METAL ROOF PANELS (E) METAL | | WALL PANELS (F ) HOLLOW METAL DOORS (G) IMPACT GLASS | | DOOR 106.3.3* PRODUCT PPROVALS- 2004 THOSE PRODUCTS | | THAT ARE REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 4) SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | 1. COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR | | PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT. | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | FAC9B72, WWW.FLORIDABUILDING.ORG. | | 3. ON THE PRODUCT APPROVAL, MARK WHICH DETAILS APPLY TO | | THIS JOB. PLEASE USE INK RATHER THAN A HIGHLIGHTER. SEE | | ADDITIONAL INFORMATION IN PACKAGE. | | | | 5) ROOFING PERMIT; ONLY CHECKED ITEMS APPLY | | ____ 1) CONTRACTOR IS TO PROVIDE THE FOLLOWING | | INFORMATION, SEE ATTACHED POLICY: MEAN ROOF HEIGHT/ | | ROOF PITCH / ROOF DECK TYPE / AREA OF EACH ROOF TYPE | | ____2) FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED | | IN ADDITION TO THE EVALUATION REPORT SUBMITTED, | | FAC9B72. WWW.FLORIDABUILDING.ORG ____3) | | FOR THE FLAT DECK, SELECT THE APPROVED ASSEMBLY YOU ARE | | USING. ALSO INDICATE WHICH FASTENER IF THE OPTIONS HAVE | | DIFFERENT PRESSURE LIMITATIONS. ____5) FOR THE FLAT | | DECK, SPECIFY THE ENHANCED FASTENING FOR CORNER AND | | PERIMETER ZONES. | | ___ 6) SEE PRODUCT LIMITATION #7. CALCULATIONS PREPARED | | BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF | | CONSULTANT REQUIRED FOR ENHANCED FASTENING. | | | | 6) FBC 1802. THE SOIL REPORT SUBMITTED BY TIERRA | | ENGINEERING NEEDS THE ORIGINAL SEAL, CERTIFICATE OF | | AUTHORIZATION NUMBER AND SIGNATURE OF THE PERSON TAKING | | RESPONSIBLE FOR THE REPORT. | | AN ENGINEER PRACTICING THROUGH A DULY AUTHORIZED | | ENGINEERING BUSINESS SHALL INDICATE THEIR NAME AND | | LICENCE #, AS WELL AS THE NAME,ADDRESS AND CERTIFICATE | | OF AUTHORIZATION # ON EACH SHEET PER 61G15-23.002 (2) | | FAC | | | | 7) FBC 106.1.1 CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED. SHEET A-1 FLOOR PLAN IS MISSING THE | | DIMENSIONS FOR ALL THE ROOMS. | | | | 8) SHEET S-3 DETAIL #2; ON THIS SHEET SHOWS THE | | MEZZANINE PRE-STRESSED PRE-CAST CONCRETE @ 5? O.C AND | | THE MEZZANINE PLAN SHOWS THEM AT 4? O.C. CLARIFY. | | | | 9) 1009.11.5 HANDRAILS SHALL RETURN TO A WALL, GUARD OR | | THE WALKING SURFACE OR SHALL BE CONTINUOUS TO THE | | HANDRAIL OF AN ADJACENT STAIR FLIGHT. WHERE HANDRAILS | | ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL | | EXTEND HORIZONTALLY AT LEAST 12 INCHES BEYOND THE TOP | | RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF ONE TREAD | | BEYOND THE BOTTOM RISER. 11-4.9(2) AT THE BOTTOM, THE | | HANDRAIL SHALL CONTINUE TO SLOPE FOR A DISTANCE OF THE | | WIDTH OF ONE TREAD FROM THE BOTTOM RISER; THE REMAINDER | | OF THE EXTENSION SHALL BE HORIZONTAL SEE FIGURE 19C AND | | 19D. SEE SHEETS S-3 / A-6. | | | | 10) FBC 505.1 THE CLEAR HEIGHT ABOVE AND BELOW THE | | MEZZANINE FLOOR CONSTRUCTION SHALL NOT BE LESS THAN 7 | | FEET. CLEARLY INDICATE THE HEIGHT BETWEEN THE MEZZANINE | | FLOOR AND THE CEILING ABOVE. 110.4.2 STORAGE & FACTORY- | | INDUSTRIAL OCCUPANCIES. THE CALCULATIONS FOR THE | | MEZZANINE FLOOR LOAD SHALL BE SUBMITTED AND ACCOMPANIED | | BY AN AFFIDAVIT FROM THE ARCHITECT OR ENGINEER STATING | | THE SAFE ALLOWABLE FLOOR LOADS ON EACH FLOOR IN POUNDS | | PER SQ FT. THE COMPUTATIONS & AFFIDAVIT SHALL BE FILED | | AS A PERMANENT RECORD OF THE BLDG DEPT. | | | | 11) PROVIDE THE SHOP DRAWINGS WHICH SHALL INCLUDE ALL | | ROOFING/ JOIST / ALUMINUM LADDER WITH PLATFORM AND | | STRUCTURAL DETAILS ETC. FOR THE BUILDING AS STATED ON | | SHEET S-1, S-2 AND S-5. THE DRAWINGS SHALL BE REVIEWED | | AND APPROVED BY THE DESIGNER OF RECORD. SHEET S-7 MAKES | | REFERENCE TO SEE NOTE #6 WHICH IN NOT ON THE SHEET. | | DETAIL #9 ON SHEET S-7 REQUIRES THE ENGINEERED DESIGN | | FOR THE OVERHANG. | | | | 12) 11-4.4.2 HEAD ROOM. WALKS, HALLS, CORRIDORS, | | PASSAGEWAYS, AISLES OR OTHER CIRCULATION SPACES SHALL | | HAVE 80 INCHES MINIMUM CLEAR HEAD ROOM (SEE FIGURE | | 8(A). IF VERTICAL CLEARANCE OF AN AREA ADJOINING AN | | ACCESSIBLE ROUTE IS REDUCED TO LESS THAN 80 IN. | | (NOMINAL DIMENSION), A BARRIER TO WARN BLIND OR | | VISUALLY-IMPAIRED PERSONS SHALL BE PROVIDED. (SEE | | FIGURE 8(C-1). | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] | 2008-06-04 17:58:16 | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-10-29 |
Time |
|
Rev Time |
12.00 |
Received By |
jjohnsto |
Date |
2007-10-26 |
Time |
09:55 |
Sent To |
|
|
Notes |
2007-10-29 11:40:30 | CONSTRUCTION SERVICES DEPARTMENT | | 200 SECOND STREET, 3RD FLOOR, | | WEST PALM BEACH, FLORIDA33401 | | TEL:561-805-6713FAX:561-805-6731 | | | | JAMES JOHNSTON, | | BUILDING PLAN EXAMINER II | | E-MAIL:JJOHNSTON @WPB.ORG | | | | | | | | | | BASIC WIND SPEED ? MPH140 | | | | PERMIT NO 07090553 | | PROJECTMAINTENANCE FACILITY SOLID WASTE ADDRESS | | 6255 N JOG ROAD | | | | DATE10/26/07 | | | | | | BUILDINGPLANREVIEW | | | | FLORIDA BUILDING CODES 2004 | | | | 1 | | PROJECT INFORMATION SHEETLS-1 | | FBCBUILDING503 | | TYPE OF CONSTRUCTION V - B | | THEB OCCUPANCY IS RATED V-B | | S-1 OCCUPANCY IS RATEDV-B | | COMMENT-PLEASE NOTE ON SHEETLS-1 | | | | | | 1-A | | WPB AMENDMENTS TO FBC 2004 EDITION | | BASIC WIND SPEED | | 117.1 BASIC WIND SPEED. THE CITY OF WEST PALM BEACH | | FALLS ENTIRELY IN THE 140 MPH REGION COMMENT-THE | | BASIC WIND SPEED IS 140 MPH | | PLEASE NOTE ON SHEETLS-1 | | | | | | 1-B | | FBCBUILDING1604.5 | | WIND IMPORTANCE FACTORII | | COMMENT- | | PLEASE NOTE ON SHEETLS-1 | | | | 1-C | | FBCBUILDING 1604.5 | | WIND EXPOSURE | | COMMENT- | | PLEASE NOTE ON SHEETLS-1 | | | | | | 2 | | FBCBUILDING1802.6SOIL TEST REPORT | | THE SOIL CLASSIFICATION AND DESIGN LOAD-BEARING | | CAPACITY | | SHALL BE SHOWN ON THE CONSTRUCTION DOCUMENT. | | WHERE REQUIRED BY THE BUILDING OFFICIAL, A WRITTEN | | REPORT | | OF THE INVESTIGATION SHALL BE SUBMITTED THAT INCLUDES, | | BUT NEED NOT BE LIMITED TO, THE FOLLOWING INFORMATION: | | COMMENT-PLEASE SUBMIT THE SOIL TEST REPORT FOR THIS | | PROJECT | | | | | | 3 | | WPB ADMENDMENT109.3.4 TERMITES. BUILDING COMPONENTS | | AND BUILDING SURROUNDINGS REQUIRED TO BE PROTECTED FROM | | TERMITE DAMAGE IN ACCORDANCE WITH SECTION 1503.6, | | SECTION 2304.13 OR SECTION 2304.11.6, SPECIFICALLY | | REQUIRED TO BE INSPECTED FOR TERMITES IN ACCORDANCE | | WITH SECTION 2114, OR REQUIRED TO HAVE CHEMICAL SOIL | | TREATMENT IN ACCORDANCE WITH SECTION 1816 SHALL NOT BE | | COVERED OR CONCEALED UNTIL THE RELEASE | | FROM THE BUILDING OFFICIAL HAS BEEN RECEIVED COMMENT | | PLEASE PROVIDE THIS INFORMATION ON DRAWINGS | | | | | | 4 | | FLORIDA STATUE713.13NOTICE OF COMMENCEMENT FILE | | NOTICE WITH THE CLERK OF COURT RECORDING DIVISION. IF | | THE | | WORK DESCRIBED IN THE NOTICE IS NOT COMMENCED WITHIN | | 90 | | DAYS OF FILING THE NOTICE WILL BECOME NULL AND VOID. | | SUBMIT THE NOTICE AT THE TIME OF PERMIT ISSUANCE AND | | POST A COPY AT THE JOB SITE BEFORE THE FIRST | | INSPECTION. | | COMMENT-FOR YOUR INFORMATION | | | | | | 5 | | FBC BUILDING504.2 AUTOMATIC SPRINKLER SYSTEM | | INCREASE. | | THIS CHAPTER OF THE CODE ALLOWS THE BUILDING HEIGHT TO | | BE INCREASED BY 20? AND THE MAXIMUM NO. OF STORIES | | INCREASE BY ONE STORY | | COMMENT-FOR YOUR INFORMATION TYPE OF | | | | | | 5-A | | FBC BUILDING506.3 AUTOMATIC SPRINKLER SYSTEM | | INCREASE | | | | COMMENT- | | AREA INCREASE WITH AUTOMATIC SPRINKLER SYSTEM IS 300 | | PERCENT FOR SINGLE STORY BUILDING | | COMMENT-FOR YOUR INFORMATION | | | | 6 | | PRODUCT APPROVALS REQUIRED | | FBC 1609.1.4 AND WPB ADMINISTRATIVE CODE 106.3 | | REGULATED BY DCA RULE 9B-72FLORIDA PRODUCT APPROVALS | | SUBMIT TWO COPIES OF EACH APPROVAL | | ( 3 COPIES IF A THRESHOLD BUILDING ) WITH FLORIDA | | PRODUCT | | APPROVAL COVER SHEET THE ARCHITECT?S / ENGINEER?S | | SIGNATURE AS APPLICABLE, STATING ?TO THE BEST OF THEIR | | KNOWLEDGE THE PRODUCT APPROVAL COMPLIES WITH | | THE PLANS AND SPECIFICATIONS. | | SEE:WEB SITEWWW.FLORIDABUILDING.COM | | | | ALUMINUM WINDOWS | | FIXED GLASS | | MULLION TUBES | | ALUMINUM OUT -SWING DOORS | | HOLLOW METAL DOORS | | EXTERIOR GLAZED DOORS | | HURRICANE SHUTTERS | | LOUVERS,NO REPORT SUBMITTED | | ROLL UP DOOR | | COMMENT-PLEASE PROVIDE THE FOLLOWING FLORIDA PRODUCT | | APPROVALS | | | | | | 7 | | FBC BUILDING1609.6 SIMPLIFIED WIND LOAD METHOD. | | 1609.1 APPLICATIONS. | | BUILDINGS, STRUCTURES AND PARTS THEREOF SHALL BE | | DESIGNED | | TO WITHSTAND THE MINIMUM WIND LOADS PRESCRIBED HEREIN. | | | | COMMENT-PLEASEPROVIDE THE DESIGN PRESSURE FOR THE | | WINDOWS AND DOORS, GARAGE DOORS, LOUVERS, MULLIONS | | | | | | 8 | | WPB AMENDMENTS TO FBC 2004 EDITION | | 110.4.2 STORAGE AND FACTORY-INDUSTRIAL OCCUPANCIES. IT | | SHALL BE THE RESPONSIBILITY OF THE OWNER, AGENT, | | PROPRIETOR OR OCCUPANT OF GROUP S WHERE EXCESSIVE FLOOR | | LOADING IS LIKELY TO OCCUR, TO EMPLOY A COMPETENT | | ARCHITECT OR ENGINEER IN COMPUTING THE SAFE LOAD | | CAPACITY. ALL SUCH COMPUTATIONS SHALL BE ACCOMPANIED BY | | AN AFFIDAVIT FROM THE ARCHITECT OR ENGINEER STATING THE | | SAFE ALLOWABLE FLOOR LOAD ON EACH FLOOR IN POUNDS PER | | SQUARE FOOT UNIFORMLY DISTRIBUTED | | 110.4.3 SIGNS REQUIRED. | | COMMENTIN EVERY BUILDING OR PART OF A BUILDING A SAFE | | FLOOR LOAD SHALL BE POSTED IN A CONSPICUOUS LOCATION. | | THIS SECTION REFERS TO THE MEZZANINE. PLEASE | | FURNISH THE SAFE LOAD CAPACITY AND NOT ON PLAN THE | | REQUIRED INFORMATION TO BE POSTED AT THE MEZZANINE. | | | | | | 9 | | FBC BUILDING 2200 | | THE FOLLOWING INFORMATION IS PROVIDED FOR | | REVIEW BY THE DESIGNER OF RECORD, THE | | SPECIALITY ENGINEER, AND THE PROJECT | | ENGINEER | | | | | | 10 | | FBC BUILDING2223.5.3 | | COMMENT THE MANUFACTURER SHALL DESIGN THE METAL SYSTEM | | BUILDING AND/OR COMPONENT SYSTEM IN ACCORDANCE WITH THE | | PROVISIONS OF CHAPTER 16 | | METAL BUILDING STRUCTURAL DESIGN, PANEL WALLS INSULATED | | PANEL CEILING, PRE-ENGINEERED METAL CANOPY | | COMMENT-PLEASE PROVIDE THE SPECIAL ENGINEERING?S | | DESIGN AND SPECIFICATIONS FOR THE METAL BUILDING | | COMPONENTS | | | | | | 10-A | | FBC BUILDING2223.4.1 | | COMMENT -THE STRUCTURAL ENGINEER OF RECORD AND/OR THE | | ARCHITECTOF RECORD SHALL REQUIRE STRUCTURAL | | SUBMITTALS FOR REVIEW | | AS AN INDICATION THAT HIS OR HER INTENT HAS BEEN | | UNDERSTOOD | | AND THAT THE SPECIFIED CRITERIA HAVE BEEN USED. THE | | STRUCTURAL SUBMITTALS SHALL BEAR THE IMPRESSED SEAL, | | SIGNATURE AND DATE OF THE SPECIALTY ENGINEER WHO | | PREPARED THEM. | | | | 10-B | | FBC BUILDING2222.4.8 | | METAL SIDING AND ROOF PANELS SHALL BE DESIGNED, WHERE | | POSSIBLE, TO BE CONTINUOUS OVER TWO OR MORE SPANS. | | COMMENT PLEASESUBMIT THE METAL BUILDING SPECIALTY | | ENGINEERING DESIGN FOR PLAN REVIEW COMPLIANCE NOTING | | THE INFORMATION PROVIDEDHEREIN | | | | | | 10-C | | FBC BUILDING2223.5.1 | | COMMENT CALCULATIONS FOR DRIFT AND DEFLECTION OF THE | | METAL | | SYSTEM BUILDING SHALL BE BY THE SPECIALTY ENGINEER. | | | | | | 10-D | | FBC BUILDING2223.8.4 | | STRUCTURAL STANDING-SEAM ROOF SHEETS SHALL BE A | | MINIMUM | | OF 24 GAUGE [0.0239 INCH (.6 MM) NOMINAL] IN THICKNESS | | COMMENT FOR YOUR INFORMATION | | | | 10-E | | FBC BUILDING2223.8.5 | | DIRECT SCREW ATTACHED ROOF AND WALL SHEETS MAY BE USED | | AS | | DIAPHRAGMS PROVIDED THE SHEETS ARE A MINIMUM OF 24 | | GAUGE | | COMMENTFOR YOUR INFORMATION | | | | 10-F | | 2222.4.3 | | FBC BUILDINGMETAL SIDING AND ROOF PANELS SHALL BE | | NOT | | | | LESS THAN 24 GAUGE. | | COMMENTFOR YOUR INFORMATION | | | | | | 10-G | | 2222.4.5 | | FBC BUILDINGTHE BENDING STRESS OF METAL SIDING AND | | ROOF | | PANELS SHALL BE DESIGNED USING A SAFETY FACTOR OF NOT | | LESS | | THAN 2.5. | | COMMENT FOR YOUR INFORMATION | | | | 11 | | FBC BUILDING 1600 LOADS | | COMMENT PLEASE VERIFY THE SUSPENDED GYPSUM CEILING | | SUPPORTED BY THE METAL ROOF STRUCTURE SYSTEM | | COMPONENTS | | WILL CARRY THE LOAD IMPOSED BY THIS CEILING SYSTEM. | | THIS WILL BE REFLECTED IN THE STRUCTURAL DESIGN BY THE | | METAL | | BUILDING MANUFACTURER?SSPECIALTY ENGINEER | | | | | | 12 | | FBC BUILDING CHAPTER 11 ACCESSIBILITY | | 11-4.1.2 ACCESSIBLE SITE AND EXTERIOR FACILITIES: NEW | | CONSTRUCTION | | SHEETC-1COMMENT PLEASE PROVIDE A DETAIL FOR THE | | 5? | | | | WIDE HANDICAP ACCESSIBLE ISLE FROM THE PARKING LOT TO | | THE | | SIDEWALK WITH A LEVEL CONNECTION | | | | | | 13 | | FLORIDA BUILDING CODE BUILDING 1210.2 WALLS. COMMENT | | PLEASE NOTE ON PLAN.. WALLS WITHIN 2 FEET OF URINALS | | AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE | | FLOOR | | | | | | 14 | | FLORIDA BUILDING CODE BUILDING 713.1 GENERAL - FIRE | | RESISTANT JOINT SYSTEM | | COMMENTOCCUPANCY SEPARATION WALL. JOINTS | | INSTALLED | | | | IN OR BETWEEN FIRE-RESISTANCE-RATED, WALLS,FLOOR OR | | FLOOR/CEILING | | ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL | | BE | | PROTECTED BY AN APPROVED FIRE-RESISTANT JOINT SYSTEM | | DESIGNED TO RESIST THE PASSAGE OF FIRE | | | | 15 | | FBC BUILDING1207.2AIR-BORNE SOUND. | | COMMENTWALLS, PARTITIONS AND FLOOR/CEILING | | ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC | | OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | | (STC) OF NOT LESS THAN 50 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
8 |
Status |
N |
Date |
2009-10-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-10-06 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-10-06 |
Time |
10:51 |
Sent To |
PC |
|
Notes |
2009-10-06 10:53:28 | ELECTRICAL SITE SURVEY NOT REVIEWED AS RECORD | | ELECTRICAL PLANS. | | ALSO NOT REVIEWED AT THE REQUEST OF KURT FROM WEST | | CONSTRUCTION. | | PLANS WOULD HAVE HAD COMMENTS AS THEY WERE SEALED BY | | LAND SURVEYOR FOR RECORD ELECTRICAL PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2009-08-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-08-07 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-08-07 |
Time |
10:37 |
Sent To |
PC |
|
Notes |
2009-08-07 10:37:31 | E5,6 AND 7 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2009-02-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-02-10 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-02-10 |
Time |
08:52 |
Sent To |
PC |
|
Notes |
2009-02-10 08:55:48 | REVISED E-4 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2008-11-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-11-25 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-11-25 |
Time |
09:14 |
Sent To |
|
|
Notes |
2008-11-25 09:15:46 | SHEET 4 TO BE REVISED BEFORE INSPECTION TO COORDINATE | | WITH SHEET E-6. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2008-11-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-11-24 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-11-24 |
Time |
10:51 |
Sent To |
|
|
Notes |
2008-11-24 11:26:37 | ** TEMPORARY FAILED STATUS. | | | | | | | | 1) NOTE: PLEASE SEE THE SUBMITTED SHEETS E-4 AND E-6 | | NEED COORDINATION. PLEASE SEE THE EXTERIOR FIXTURES | | SUBMITTED AND SHOWN ON THE PHOTO-METRICS ACTUALLY DO | | NOT INCLUDE MANY FIXTURES WHICH DO CONTRIBUTE TO THE | | LIGHTING LEVELS. | | PLEASE SEE THE SUBMITTED ENERGY CALCULATIONS DO NOT | | INCLUDE ALL EXTERIOR FIXTURES. A CALLED WAS PLACED TO | | THE ELECTRICAL ENGINEER AND LEAD DESIGNER ON PROJECT. | | SHEETS E-4 AND E-6 WILL BE REVISED AT A LATER DATE | | HOWEVER THE ENERGY CALCULATIONS WILL NEED TO BE REVISED | | AT THIS TIME BEFORE PERMIT ISSUANCE. | | 13-415.2.ABC.1.3. | | | | 2) NOTE: PLEASE SEE THE 2ND SET AS THE PLANS ARE NOT | | COMPLETE. SHEETS FA1 AND FA2 ARE MISSING FROM ONE SETS. | | | | | | | | **IMPORTANT** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2008-09-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-09-04 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-09-04 |
Time |
13:05 |
Sent To |
|
|
Notes |
2008-09-04 13:06:12 | | | | | | | | | | | ** DENIED 3RD REVIEW ** | | | | ** PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEW ARE | | STILL IN NEED OF ADDRESSING. | | | | | | | | 1) NOTE: PLEASE BE SURE TO SUBMIT TWO COPIES OF ALL | | DOCUMENTS. ONLY ONE SPECIFICATION BOOK WITH | | CALCULATIONS AND MANUFACTURES SPECS WAS LOCATED. IF | | THIS HAD BEEN THE ONLY COMMENT THE SECOND SET COULD | | HAVE BEEN BROUGHT IN. | | FBC 106.1 | | | | 2) NOTE: PLEASE SEE PREVIOUS REVIEW COMMENTS WITH | | RESPECT TO THE ENERGY CALCULATIONS. THE VERSION 3.0 AS | | SUBMITTED IS NOT ADOPTED BY THE FLORIDA BUILDING CODE. | | PLEASE GO TO THE FLORIDA SOLAR ENERGY/ENERGY GAUGE | | WEBSITE AS THERE IS A PATCH/UPDATE TO CORRECT ANY | | PROGRAMS SOLD WHICH SHOW THE 3.0. THIS SHOULD BE | | *VERSION 2.5*. THE STATE AS WELL AS FLORIDA | | SOLAR/ENERGY GAUGE IS AWARE OF THIS ISSUE. | | FBC 13-400.3.A | | | | 3) NOTE: PLEASE MAKE SURE ALL LIGHTING AS SHOWN ON | | PLANS AS WELL AS OTHER BUILDING COMPONENTS ARE PLACED | | IN THE INPUT DATA REPORT. THIS INFORMATION FOR ALL | | SYSTEMS AND COMPONENTS IS REQUIRED TO COORDINATE. | | PLEASE SEE THE PREVIOUS REVIEW AS SOME EXAMPLES WERE | | GIVEN YET SOME OF THESE ARE STILL THE SAME. THE | | EXAMPLES ONCE AGAIN IS THE EXTERIOR LIGHTING ON THE IDR | | WHICH IS *BLANK*. THIS IS NOT POSSIBLE WHEN THE PLANS | | CLEARLY SHOW EXTERIOR LIGHTING. | | PLEASE SEE ANOTHER EXAMPLE IS INTERIOR LIGHTING. THERE | | ARE ONLY TWO TYPES OF LIGHTING FIXTURES ON THE IDR YET | | BASED ON THE PLANS SUBMITTED THERE IS A FAR GREATER | | NUMBER OF FIXTURE TYPES. | | ** THESE ARE ONLY TWO EXAMPLES: THERE ARE OTHER ITEMS. | | 13-415.2, 13-415.2.ABC.1.1,.1.2 AND .1.3 | | | | 4) NOTE: PLEASE SEE PREVIOUS NOTES WITH RESPECT TO A | | REQUIRED GROUNDING ELECTRODE RISER TO BE SHOWN FOR THE | | ATTACHMENT OF ALL TRANSFORMERS. | | THE RESPONSE MENTIONS TO SEE RISER AND NEW NOTES | | HOWEVER THIS ONLY ADDRESSES THE ONE TRANSFORMER ON THE | | LINE SIDE OF SERVICE. THE PREVIOUS COMMENT REFERENCE | | CODES FOR OTHER TRANSFORMER SUCH AS SHOWN ON RISER. | | 250.20,250.30,250.58 AND 250.66 | | ** PLEASE CALL TO GO OVER IF THERE ARE ANY QUESTIONS. | | | | 5) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | REPEAT COMMENTS FOR CODE COMPLIANCE. AS THIS IS ONLY | | THE SECOND REVIEW UNDER PERMIT APPLICATION THIS IS ONLY | | A NOTICE GIVEN AT THIS TIME. | | | | | | | | | | | | **IMPORTANT** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2008-06-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-06-13 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-06-13 |
Time |
12:48 |
Sent To |
|
|
Notes |
2008-06-13 12:48:49 | ** DENIED ** | | | | THIS IS THE FIRST REVIEW UNDER PERMIT APPLICATION, | | SECOND REVIEW TOTAL. PLANS WERE ONLY SUBMITTED FOR | | *PLAN REVIEW* FIRST TIME. | | | | ** PLEASE SEE SOME ITEMS ARE STILL IN NEED OF | | ADDRESSING FROM PREVIOUS REVIEW. THERE ARE ALSO SOME | | NEW COMMENTS FOR CHANGES MADE TO PLANS. | | | | 1) NOTE: PLEASE BE SURE THE ADDRESS OF THE PROJECT IS | | CORRECTED ON PLANS. THE APPLIED ADDRESS LOCATION AS | | GIVEN ON PREVIOUS REVIEW IS 6255 N JOG RD. HOWEVER THE | | PLANS AND CALCULATIONS NOW HAVE 6527 N JOG RD. IT IS | | UNCLEAR WHERE THIS NEW NUMERICAL DESIGNATION IS COMING | | FROM. THE PERMIT APPLICATION SUBMITTED CONTAINS 6255. | | PLEASE BE SURE TO CORRECT ALL TITLE BLOCKS ON PLANS FOR | | ALL TRADES WHETHER OR NOT COMMENT IS MADE BY ANY OTHER | | REVIEWER(S). | | ** PLEASE KNOW THAT ANY SHEETS WHICH DO NOT NEED TO BE | | REPRINTED FOR CORRECTIONS MAY HAVE THE ADDRESS | | CORRECTED BY HAND IN A NEAT FASHION. IF THERE ARE ANY | | QUESTIONS ON THIS PLEASE CALL. | | FAC61G15-23.002, 61G1-16.004, FBC ADMIN SECTIONS | | 106.3.5.1.2, 106.5 | | | | 2) NOTE: PLEASE SEE THE PERMIT APPLICATION SHOWS IN | | DESCRIPTION THE APPLIED SQ FT AS 11,900 SQ FT AND ALSO | | AS 11,900,000 SQ FT. THIS SEEMS TO BE DONE IN ERROR. | | PLEASE KNOW HOWEVER THE ENERGY CALCULATIONS SHOW A SQ | | FT FOR CONDITIONED AND UN-CONDITIONED SPACE AS ONLY | | 6120 SQ FT. THE ARCHITECTURAL SHEETS SHOW AS HIGHER SQ | | FOOTAGE THAN THE CALCULATIONS. | | FBC 106.1.2 FOR COORDINATION. | | | | 3) NOTE: PLEASE SEE THE ENERGY CALCULATIONS ARE NOW | | JUST BEING SUBMITTED FOR THE FIRST REVIEW. THE ENERGY | | CALCULATIONS SUBMITTED ARE NOT CODE COMPLIANT IN | | SEVERAL LOCATIONS. COMPONENTS OF THE BUILDING AND | | MECHANICAL SYSTEM ARE NOT COMMENTED ON BY THIS REVIEWER | | ALTHOUGH ALL SYSTEMS ON PLANS ARE REQUIRED TO | | COORDINATE WITH THE SUBMITTED CALCULATIONS AND INPUT | | DATA REPORT. IN THE REMAINDER OF THIS COMMENT THE INPUT | | DATA REPORT WILL BE NOTED AS IDR. | | PLEASE BE SURE ALL LIGHTING ON PLANS IS ACTUALLY PLACED | | INTO THE IDR. THERE ARE SEVERAL ITEMS WHICH ARE NOT | | SHOWN. THE FOLLOWING ARE SOME EXAMPLES GIVEN AS A | | BENEFIT ONLY AND ARE IN NO WAY ALL POSSIBLE ITEMS WHICH | | DO NOT COMPLY. THIS IS NOT AN EXHAUSTED LIST. | | | | FOR EXAMPLE: | | PLEASE SEE THE IDR FOR EXTERIOR LIGHTING. THIS IS BLANK | | WITH NO LIGHTING AT ALL SHOWN. HOW IS THIS POSSIBLE | | WHEN THE PLANS CLEARLY SHOW SEVERAL EXTERIOR FIXTURES? | | | | FOR EXAMPLE: | | PLEASE SEE THE IDR FOR INTERIOR LIGHTING. HOW IS IT | | POSSIBLE THIS SHOWS ONLY THREE TYPES OF FIXTURES WHEN | | THE PLANS CLEARLY SHOW SEVERAL OTHER TYPES AND | | WATTAGES? | | PLEASE SEE THAT ALL LIGHTING ON PLANS AND LIGHTING | | FIXTURE LEGEND COORDINATE WITH THE IDR. | | | | FOR EXAMPLE: | | PLEASE SEE THE SQUARE FOOTAGE AS NOTED ABOVE IN NOTE #2 | | DOES NOT COORDINATE WITH PLANS PR PERMIT APPLICATION. | | | | FOR EXAMPLE: | | PLEASE SEE THE METHOD OF CONTROL CAN NOT BE *MANUAL | | ON/OFF? WHEN THERE IS CLEARLY AUTOMATED CONTROLS FOR | | LOCATIONS IN AND OUTSIDE THE BUILDING. | | | | ** AS NOTED ABOVE THIS IS A BRIEF LIST FOR BENEFIT ONLY | | AND IS NOT A LIST OF ALL ITEMS WHICH DO NOT CORRELATE. | | THERE ARE OTHER ITEMS. | | PLEASE SEE 13-415.2.ABC.1.1, .1.2, .1.3, 13-415.2 ETC | | | | 4) NOTE: PLEASE SEE THE VERSION OF CALCULATIONS | | SUBMITTED IS REQUIRED TO BE FLA/COM 2.5. PLEASE SEE | | 13-400.3.A AS THE VERSION SUBMITTED IS NOT YET ADOPTED | | BY THE FLORIDA BUILDING CODE. THIS HAS BEEN CONFIRMED | | DIRECTLY WITH THE FLORIDA BUILDING COMMISSION. | | | | 5) NOTE: PLEASE SUBMIT THE MANUFACTURES SPECS/CUT | | SHEETS FOR THE FOLLOWING ITEMS AS REQUESTED ON PREVIOUS | | REVIEW. THE RESPONSE LETTER MENTIONS THESE WERE | | VERIFIED FOR LISTING AND SUBMITTED HOWEVER THEY COULD | | NOT BE LOCATED IN ANY DOCUMENTS SUBMITTED. THE RESPONSE | | MENTIONS THE CONTRACTOR MAY CHANGE DURING THE | | CONSTRUCTION PROCESS. THIS IS NOT A PROBLEM, THIS | | OFFICE WOULD REQUEST ANY REVISIONS TO | | SPECS/MANUFACTURES CUT SHEET ON FILE BE SUBMITTED FOR | | REVIEW AND STAMPING. ONE COPY OF REVISED SPECS WOULD | | STAY ON FILE AND THE OTHER(S) WOULD GO BACK TO JOBSITE. | | | | PLEASE BE SURE TO SUBMIT THE SPECS/CUT SHEETS AT THIS | | TIME FOR REVIEW. | | 110.3, 90.7 | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | 6) NOTE: THE PREVIOUS REVIEW GAVE NOTICE TO REQUIRED | | LIGHTING CONTROLS. THE RESPONSE MENTIONS THIS FACILITY | | IS A 24HR OCCUPIED LOCATION AND DEVICES WILL BE | | INSTALLED IN SOME ROOMS ONLY WHICH ARE NOT 24HR USE. | | PLEASE SHOW ON THE LIGHTING PLANS WHICH ROOMS AND AREAS | | ARE GOING TO CONTAIN THE AUTOMATED CONTROLS. AT THIS | | TIME THE PLANS ONLY SHOW STANDARD SWITCHING DEVICES IN | | ALL LOCATIONS. THE DETAIL FOR OCCUPANCY SENSORS PLACED | | ON SHEET E-17 DOES NOT SHOW LOCATIONS ON PLANS. | | PLEASE REVISE LIGHTING PLANS. | | 13-415.1.ABC.1.1, .1.2, .1.3. | | ** EXTERIOR LIGHTING IS SHOWN THROUGH * CONTACTOR* WITH | | PHOTO-SENSOR CONTROL. THIS WILL BE CONFIRMED TO COMPLY | | WITH FBC 13-415.1.ABC.1.4 | | | | 7) NOTE: PLEASE SHOW THE LOCATION AND GROUNDING | | ELECTRODE ATTACHMENT AND CONDUCTORS FOR THE | | TRANSFORMERS. THE RESPONSE MENTIONS THE RISER AND E-3 | | WAS REVISED HOWEVER THIS INFORMATION COULD NOT BE | | LOCATED?? | | PLEASE SEE 250.20, 250.30, 250.50, 250.58 AND 250.66 | | | | 8) NOTE: PLEASE VERIFY THE STORAGE AREA UPSTAIRS WILL | | NOT CONTAIN ANY LIGHTING AND WILL ONLY USE THE LIGHTING | | WHICH IS FROM OPEN AREA AS PLANS DO NOT SHOW ANY LIGHTS | | AT THIS TIME. | | FBC 106.1.2 | | | | 9) NOTE: PLEASE SHOW THE REQUIRED LEVELS FOR | | PHOTO-METRICS ON PLANS PER PREVIOUS REVIEW COMMENTS. | | THESE WERE SUBMITTED IN RESPONSE BOOK. HOWEVER THESE | | ARE REQUIRED TO BE SHOWN ON PLANS. THE LIGHTING FIXTURE | | USED FOR EMERGENCY USE ON PLANS ARE NOT THE SAME AS THE | | FIXTURES SHOWN THE SEPARATE PHOTO-METRICS SHEETS. | | PLEASE COORDINATE. | | FAC 61G15-33.004, NFPA-101 7.8.1.3, 7.9.2.2 | | | | ** AS STATED ON PREVIOUS AS NOT ALL ITEMS ARE SHOWN AS | | OF YET THERE MAY BE NEW COMMENTS ON THE FOLLOWING | | REVIEW WHICH CAN NOT BE MADE AT THIS TIME. | | | | | | | | ** IMPORTANT** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | HESITATE IN CONTACTING THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-10-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-10-15 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-10-15 |
Time |
13:07 |
Sent To |
|
|
Notes |
2007-10-15 16:11:29 | **** DENIED **** | | | | | | ** PLAN REVIEW | | MAINTENANCE BUILDING | | SOLID WASTE AUTHORITY | | | | 1) NOTE: PLEASE KNOW THE PROJECT HAS ONLY BEEN | | SUBMITTED FOR *PLAN REVIEW* ONLY AND HAS NOT BEEN | | SUBMITTED FOR PERMIT APPLICATION. | | PLEASE KNOW ONCE ALL CODE COMMENTS ARE ADDRESSED, PLANS | | WILL STILL BE IN A FAILED STATUS UNTIL PERMIT | | APPLICATION IS MADE. | | ALL VERIFICATION OF LICENSE INFORMATION WILL BE DONE AT | | THAT TIME. | | | | 2) NOTE: PLEASE BE SURE ALL OF THE FOLLOWING RELEVANT | | CODES ARE STATED ON PLANS. | | PLEASE KNOW THAT ALL PERMIT APPLICATIONS DATED AFTER | | DECEMBER 8TH, 2006 FALL UNDER THE FOLLOWING CODES AT A | | MINIMUM. | | PLEASE BE AWARE OF ANY OTHER CODES WHICH MAY BE | | REFERENCED BY OTHER TRADES DURING THEIR REVIEW. THE | | FOLLOWING IS NEEDED ON ELECTRICAL SHEETS AS WELL AS | | FIRE ALARM SHEETS BY THIS REVIEWER AT A MINIMUM. | | 2004 FBC W/ 2006 REVISIONS. | | 2005 NFPA-70 | | 2002 NFPA-72 | | 2003 NFPA-101 | | | | ** PLEASE SEE SOME CODES ON SOME SHEETS ARE NO LONGER | | IN EFFECT. FOR EXAMPLE, PLEASE SEE FA-1 WHICH | | REFERENCES THE 2000 LS CODE, 2002 NEC IN NOTES 10 AND | | 12. | | PLEASE ALSO SEE NOTES MENTIONS *PALM BEACH COUNTY*, THE | | ACTUAL LOCATION IS IN THE CITY OF WEST PALM BEACH | | JURISDICTION. | | | | FBC 106.1.2, 110.1.2 ETC. | | | | 3) NOTE: PLEASE SUBMIT ENERGY CALCULATIONS TO COMPLY | | WITH THE CURRENT FBC AS NOTED ABOVE. | | PLEASE BE SURE ALL EXTERIOR AND INTERIOR LIGHTING ON | | PLANS COORDINATE WITH THE INPUT DATA REPORTS. | | PLEASE SEE 13-415.1.AB.1, 13-415.2, 13-415, | | 13-415.2.ABC.1.1, .1.2 AND .1.3. | | AS NO ENERGY CALCULATIONS WERE SUBMITTED NO REVIEW CAN | | BE DONE AT THIS TIME. THERE MAY BE NEW COMMENTS ON THE | | NEXT REVIEW. | | FBC 106.1.2 | | | | 4) NOTE: PLEASE SEE 13-415.1.ABC.1.1, .1.2, .1.3 AND | | .1.4 FOR MISSING LIGHTING CONTROLS REQUIRED. | | PLEASE INDICATE TIME SCHEDULING IF TIMER CONTROLLED. | | PLEASE INDICATE OVER RIDE DEVICES. | | PLEASE INDICATE OVER RIDE MAXIMUM TIMES. | | **(PLEASE SEE THE MAXIMUM TIMES FOR OCCUPANCY TYPE | | DEVICES ARE 30MINS AND MAXIMUM FOR TIMER OVER RIDE IS | | 4HRS) NOTED FOR INFORMATION) | | | | 5) NOTE: PLEASE CORRELATE ALL LIGHTING CONTROL DEVICES | | WITH THE SYMBOL LEGEND. FOR EXAMPLE: PLEASE SEE S WITH | | THE LETTER DESIGNATIONS IS NOT ALL ON LEGEND. SEE SX IN | | WOMEN'S TOILET, SEE SU IN JAN'S CLOSET. THESE ARE A FEW | | AS NOTED. THE COMMENT #4 WILL REQUIRE ADJUSTMENTS | | ALSO. | | | | 6) NOTE: PLEASE SEE FBC 11-4.28.1,.2 AND .3(4) FOR | | MINIMUM ADA LEVELS FOR ALL HORN AND STROBE DEVICES. | | PLEASE SEE THE PLANS INDICATE ON LEGEND A *XX* FOR | | CANDELA LEVELS. PLEASE KNOW THAT ALL LEVELS ARE | | REQUIRED. PLEASE SEE THERE ARE SEVERAL LOCATIONS ON | | PLANS IN WHICH LESS THAN 75 CD IS BEING SHOWN. | | (EXAMPLE: 15, 30) PLEASE SEE .3(4) OF SECTION GIVEN AS | | THE MINIMUM LEVEL IS 75 CD. | | PLEASE ADJUST. | | | | 7) NOTE: PLEASE ADJUST ALL CIRCUITING ON PANEL | | SCHEDULE(S) AS THE CIRCUITS ARE REQUIRED TO BE SPECIFIC | | TO ALL ROOMS AND AREAS IN WHICH THEY FEED. PLEASE KNOW | | THE GENERAL USE OF *LIGHTING* AND *RECEPTACLES* NEEDS | | TO BE SPECIFIC. | | THE ROOMS AND AREAS MAY CONTAIN A NUMERICAL DESIGNATION | | IF DESIRED. | | PLEASE SEE THE FOLLOWING TEXT WHICH IS TAKEN DIRECTLY | | FROM THE NEC. | | | | *SECTION 408.4 WAS REVISED FOR THE 2005 CODE TO REQUIRE | | THAT THE IDENTIFICATION FOR EVERY CIRCUIT SUPPLIED BY A | | PANEL-BOARD OR SWITCHBOARD BE LEGIBLE AND CLEARLY STATE | | THE SPECIFIC PURPOSE FOR WHICH THE CIRCUIT IS USED. | | CIRCUITS USED FOR THE SAME PURPOSE MUST BE IDENTIFIED | | AS TO THEIR LOCATION. FOR EXAMPLE, SMALL APPLIANCE | | BRANCH CIRCUITS CAN SUPPLY OUTLETS IN THE KITCHEN, | | DINING ROOM, AND KITCHEN COUNTERTOPS. IDENTIFYING THE | | CIRCUITS AS SMALL APPLIANCE BRANCH CIRCUITS IS NOT | | ACCEPTABLE; INSTEAD, THEY SHOULD BE IDENTIFIED AS | | ``KITCHEN WALL RECEPTACLES,'' ``DINING ROOM FLOOR | | RECEPTACLE,'' OR ``KITCHEN COUNTERTOP RECEPTACLES LEFT | | OF SINK.'' CIRCUIT DIRECTORIES CONTAINING MULTIPLE | | ENTRIES WITH ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT | | PROVIDE THE SUFFICIENT DETAIL REQUIRED BY THIS | | SECTION.* | | 408.4, 310.16, 240.4 ETC | | FBC 106.3.5.1.2, 110.1.2, 106.1.2 | | | | 8) NOTE: PLEASE SUBMIT MANUFACTURES SPECS/CUT SHEETS | | FOR THE FOLLOWING ITEMS. | | ATS, AND GENERATOR TAP BOX. | | ** PLEASE BE AWARE THERE ARE TAP BOXES ON THE MARKER | | WHICH THIS AHJ HAS SEEN WHICH ARE NOT LISTED FOR USE, | | AND WET/OUTDOORLOCATIONS WHEN CONNECTIONS ARE MADE. | | 90.7, 110.3 | | FBC 106.1.2 | | | | 9) NOTE: PLEASE CLARIFY GENERATOR, AS THE TRANSFER | | SWITCH BEING INSTALLED IS AN AUTOMATIC DEVICE WHICH | | LENDS TO A PERMANENTLY INSTALLED GENERATOR HOWEVER | | COULD NOT LOCATE THIS UNIT ON PLANS. | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | 10) NOTE: PLEASE CLARIFY THE MAIN AS SHOWN ON RISER | | AHEAD OF THE ATS. THIS DISCONNECT SEEMS TO INDICATE A | | *SHUNT TRIP* PUSH BUTTON OF SOME TYPE FROM A GLASS | | BREAK. DOES THIS MAIN STILL CONTAIN A MANUAL MEANS OF | | DISCONNECT RATED FOR THE LOAD SERVED PER 230.76 AND | | 230.79? | | 110.3, 90.7 | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | 11) NOTE: PLEASE CLARIFY THE MAIN CIRCUIT BREAKER FOR | | PANEL DP. THE RISER CONTAINS A NOTE WHICH MENTIONS THIS | | IS NOT TO BE SERVICE ENTRANCE RATED? | | AS THE INSTALLATION OF THE GENERATOR IS NOT CLEAR AT | | THIS TIME, PLEASE BE SURE TO SEE 225.31-225.39 ALONG | | WITH 702.11 AS THE DISCONNECTING MEANS FOR THE FEEDERS | | COMING FROM A GENERATOR NEEDS TO MEET THE SECTIONS AS | | NOTED ABOVE. | | PLEASE ALSO CLARIFY THE NOTE ON THE PANEL DP WHICH | | MENTIONS THIS EQUIPMENT IS: * 800A, 277/480V, | | *4P*,,,,*.IT IS UNCLEAR WHAT THE 4P IS. IS THE | | NEUTRAL BEING CONTROLLED BY THIS BREAKER? | | PLEASE SUBMIT THE SPECS/CUT SHEET FOR THIS EQUIPMENT. | | 110.3, 90.7 | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | 12) NOTE: PLEASE SUBMIT PHOTO-METRICS FOR THE STAIRS | | UNDER NORMAL AND EMERGENCY USE. PLEASE SEE NFPA-101 | | 7.8.1.3, AND 7.9.2.2 FOR MINIMUM LEVELS OF 10FT CANDLES | | UNDER NORMAL AND IS PERMITTED DOWN TO 1FT CANDLE UNDER | | EMERGENCY. | | FAC 61G15-33.004 | | FBC 106.1.2 | | | | 13) NOTE: PLEASE SEE THE FOOTING STEEL WHICH IS | | REQUIRED TO BE PART OF THE GROUNDING ELECTRODE SYSTEM | | COULD NOT BE LOCATED ON RISER/PLANS PER 250.50. | | | | 14) NOTE: PLEASE INDICATE A DETAIL/SHOW LOCATION OF THE | | TRANSFORMER GROUNDING ELECTRODE SYSTEM PER 250.20, | | 250.30, AND 250.50 | | | | 15) NOTE: PLEASE SEE THE ADDRESS IS MISSING ON | | PLANS/TITLE BLOCKS PER 61G15-23.002 AND 61G1-16.004. | | FBC 110.1.2, 106.1.2, 106.3.5 | | PLEASE KNOW THE ADDRESS LOCATION AS APPLIED FOR AT THE | | PCN LOCATION PROVIDED ON PLAN REVIEW APPLICATION IS | | 6255 N. JOG RD. | | THIS IS NOT YET CONFIRMED AND HAS BEEN ROUTED TO THE | | ADDRESSING REVIEWER FOR VERIFICATION FOR ACTUAL SITE | | ADDRESS CONFIRMATION. | | PLEASE DO NOT BASE ADDRESS ON TITLE BLOCKS UNTIL | | VERIFIED WITH THE ADDRESSING REVIEWER. | | | | 16) NOTE: PLEASE KNOW ALL LOW VOLTAGE AS SHOWN ON PLANS | | WILL BE REQUIRED TO BE UNDER SEPARATE PERMITS. THESE | | MAY BE USED FOR REFERENCING HOWEVER WILL BE REQUIRED TO | | PULL SEPARATE PERMITS. | | THE LV FOR CATV | | LV FOR SECURITY IS REQUIRED UNDER SEPARATE LV PERMIT | | FROM CATV, PHONE ETC. | | ** THIS IS NOTED FOR INFORMATIONAL PURPOSE ONLY AND NO | | CORRECTIONS OR ADJUSTMENTS TO PLANS ARE NEEDED. | | | | 17) NOTE: PLEASE KNOW THE AIC RATINGS SHALL BE SET AND | | STATED BY THE ENGINEER OF RECORD. THE AVAILABLE FAULT | | CURRENT SHOULD BE DETERMINED AND SIZING OF EQUIPMENT IS | | REQUIRED BASED ON THE AVAILABLE FAULT CURRENT. | | NOTES ON RISER *KEYED NOTES* MENTIONS THIS IS TO BE | | DONE BY THE ELECTRICAL CONTRACTOR AND THE LEVELS ON | | PLANS ARE FOR BIDDING PURPOSES ONLY. | | PLEASE SEE 110.9 NEC. | | FBC 106.1.2, 106.3.5, ETC AS THE RECORD SETS OF PLANS | | ARE REQUIRED TOCONTAIN THE ACTUAL INSTALLED AND | | SPECIFIED. | | | | 18) NOTE: PLEASE VERIFY CIRCUITING FOR SITE LIGHTING | | AS SHOWN ON E-3 WHICH IS CIRCUITED TO H1-6 AND THIS | | SAME CIRCUIT IS FOR SEVERAL WALL LIGHTING FIXTURES ON | | BUILDING ON E-6. | | PLEASE SEE PANEL SCHEDULE ON E-10 MENTIONS WALL | | LIGHTING ONLY. | | | | 19) NOTE: *** IMPORTANT, AS THERE ARE SEVERAL ITEMS NOT | | YET SUBMITTED FOR REVIEW, REVIEW NOTES ABOVE CAN ONLY | | BE DONE ON DOCUMENTS AND PLANS SUBMITTED. | | THERE MAY BE NEW COMMENTS ON THE FOLLOWING REVIEW BASED | | ON NEW PLANS, CHANGES ETC WHICH CAN NOT BE MADE AT THIS | | TIME. | | | | ** PLEASE SEE COMMENTS FROM OTHER TRADES WHICH WILL | | AFFECT PLANS, SUBMITTED DOCUMENTS AND ELECTRICAL | | PLANS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | | | | 2007-10-15 13:07:27 | | | | | IHN ELEC FOR REVIEW. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
5 |
Status |
P |
Date |
2009-08-11 |
|
|
Cont ID |
|
Sent By |
efabian |
Date |
2009-08-11 |
Time |
15:32 |
Rev Time |
0.25 |
Received By |
efabian |
Date |
2009-08-11 |
Time |
15:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2008-09-04 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2008-09-04 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2008-09-04 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
F |
Date |
2008-08-29 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2008-08-29 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2008-08-29 |
Time |
13:52 |
Sent To |
|
|
Notes |
2008-08-29 14:04:01 | ****FAILED ****** | | | | 1. PLEASE SHOW ON DRAWINGS THE TURBIDITY BARRIER | | DETAILS OF POLLUTION PREVENTION PER FDEP. DRAWING PLANS | | MUST SHOW TURBIDITY BARRIER AROUND THE CATCH BASINS, | | WATER FALLS, ANY LAKES ETC DURING CONSTRUCTION AND ALL | | DEMOLITION PHASE PER FDEP. | | | | PLEASE RESPOND EACH ITEM IN DETAIL AND REFERENCE | | DRAWINGS TO EXPEDITE YOUR PERMITTING PROCESS | | | | RASIK CHOKSHI 805-6723 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2008-05-30 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2008-05-30 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2008-05-30 |
Time |
13:50 |
Sent To |
|
|
Notes |
2008-05-30 14:12:38 | ****FAILED ****** | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | NOI. | | YOU CAN GET NOI INFO FROM | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | EFFECTIVE MAY 1, 2003 | | OUR RESPONSE: YOUR RESPONSE PROVIDED IN APPENDIX B IS | | NOT ENOUGH. YOU NEED TO APPLY FOR NOI AT FDEP, NPDES. I | | HAVE PROVIDED WEB SIDE ABOVE FOR YOU. | | | | 2. PLEASE SHOW ON STORM WATER QUALITY CALCULATION THAT | | YOU HAVE CONSIDERED FLOOD ZONE AREA, & 5,10, 25, 100 | | YEAR FLOOD CRITERIA AND CROWN OF THE ROAD WHEN YOU | | DETERMINE THE FIRST FLOOR ELEVATION. | | | | 3. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA YOU | | ARE DEVELOPING, GREEN AREA, LAKE AREA, PARKING AREA, | | IMPERVIOUS,PERVIOUS AREAYOU ARE DEVELOPING FOR THIS | | PROJECT . | | | | 4. A COPY OF SFWMD PERMIT,,GEO-TECH REPORT &STORM | | WATER QUALITY CALCULATIONS MUST BE APPROVED FROM 1000 | | 45TH STREET ENGINEERING SERVICES BEFORE WE APPROVE. | | | | 5. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION | | DETAILS,CLOTHES USED FOR SILT ETC. DRAWING PLANS MUST | | SHOW SILT FENCE AROUND THE WHOLESITE & TURBIDITY | | AROUND THE CATCH BASINS DURING CONSTRUCTION AND ALL | | DEMOLITION PHASE.HEIGHT OF FENCE SHOULD BE HIGH | | ENOUGH PER FDEP TO STOP DUST PARTICLES. | | | | 6. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVE. | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | PERMITTING PROCESS | | | | RASIK CHOKSHI805-6723 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2007-10-31 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-10-31 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-10-31 |
Time |
10:23 |
Sent To |
|
|
Notes |
2007-10-31 10:23:19 | ****FAILED ****** | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | NOI. | | YOU CAN GET NOI INFO FROM | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | EFFECTIVE MAY 1, 2003 | | 2. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR | | SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP | | PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FROM | | 1000, 45 STREET FOR ALL THESE CITY STANDARDS NOTES. | | PHONE# 494-1040 | | 3. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | 4. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED | | FLOOD ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA | | AND CROWN OF THE ROAD WHEN YOU DETERMINE THE FIRST | | FLOOR ELEVATION. | | 5. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA, | | GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREAYOU | | ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE | | THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH | | AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE | | PROVIDE A COPY OF THESE CALCULATIONS. | | 6. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE | | SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM | | ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE | | CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING | | ELEVATION, ETC ON DRAWINGS, CALCULATION FOR | | EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET | | DETENTION AREAS IN STORM WATER CALS IF YOU HAVE ALL | | THESE. | | 7. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | YOUR SITE FOR STORM WATER DRAIN SO YOUR SITE DO NOT GET | | FLOODED AND HAVE ENOUGH DRAINS. | | 8. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, &STORM | | WATER QUALITY CALCULATIONS. STORM WATER CALS MUST BE | | APPROVED FROM 100045TH STREET ENGINEERING SERVICES. | | 9. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION | | DETAILS,CLOTHES USED FOR SILT ETC., PLANS SHOWING SILT | | FENCE AROUND THE SITE & CATCH BASINS DURING | | CONSTRUCTION AND ALL DEMOLITION PHASE.HEIGHT OF FENCE | | SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST PARTICLES. | | | | 10. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | PERMITTING PROCESS | | | | RASIK CHOKSHI805-6723 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2008-12-04 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-12-04 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-12-04 |
Time |
12:32 |
Sent To |
|
|
Notes |
2008-12-04 13:26:29 | *****PROVISO***** | | | | | | PLAN SHEETS C-3, C-5, LS-1, A-1, A-2, A-3, E-6, FA-1 | | THRU FA-4, FP-1 & FP-2 WERE STAMPED, INITIALED, AND | | DATED. PLEASE BE ADVISED THAT SHEET FP-2 IN ONE OF THE | | PLAN SETS IS MISSING AND THEREFORE NEEDS TO BE | | SUBMITTED FOR FIRE-STAMPING. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2008-09-22 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-09-22 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-09-22 |
Time |
16:06 |
Sent To |
|
|
Notes |
2008-09-22 16:20:29 | *****PROVISO***** | | | | ALL PREVIOUS PLAN REVIEW COMMENTS HAVE BEEN ADDRESSED; | | THE APPROPIATE PLAN SHEETS TO BE FIRE-STAMPED WHEN THE | | OTHER REVIEW COMMENTS HAVE BEEN SATISFIED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2008-06-24 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-06-24 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-06-24 |
Time |
13:09 |
Sent To |
|
|
Notes |
2008-06-24 13:13:37 | *****DENIED***** | | | | ## PREVIOUS COMMENTS (WHICH STILL NEED TO BE | | ADDRESSED): | | | | 04. LANDSCAPING SHALL NOT INTERFERE OR HINDER ACCESS TO | | FIRE PROTECTION EQUIPMENT AND DEVICES. COULD NOT LOCATE | | COMMENT AS INDICATED IN YOUR RESPONSE | | | | 07. ON THE APPROPIATE EXTERIOR ELEVATION, POST THE | | NUMERICAL ADDRESS ON THE BUILDING. INDICATE WHICH | | EXTERIOR ELEVATION WOULD BE THE FRONT OR MAIN ENTRANCE | | TO THE BUILDING. AS PER WEST PALM BEACH CODE, ADDRESSES | | SHALL BE POSTED ON THAT PORTION OF THE STRUCTURE | | FRONTING OR FACING UPON THE STREET OR PRINCIPAL | | VEHICULAR ACCESS TO THE PREMISES, SO AS TO BE VISIBLE | | TO APPROACHING VEHICLES. | | | | 11. THE FIRE DEPARTMENT CONNECTION (FDC) SHALL BE | | EQUIPPED WITH KNOX LOCKING CAPS. FOR APPLICATIONS, | | CONTACT WEST PALM BEACH FIRE PREVENTION BUREAU AT | | 561-804-4724. ADD COMMENT TO SHEET FP-1 | | | | 12. ELECTRONIC SWITCHES, CHAIN AND LOCK SHALL BE | | REQUIRED ON THE FIRE LINE BACKFLOW DEVICE. ADD COMMENT | | TO SHEET C-3 AND/OR SHEET FP-1. | | | | ## NEW COMMENT: | | AA. ON SHEET E-6, THERE IS AN EMERGENCY LIGHT | | ILLUSTRATED ON THE SOUTH WALL OF THE TOOL STORAGE (ROOM | | 120) BUT NONE ILLUSTRATED ON SHEETS LS-1 AND A-2; | | PLEASE CORRELATE THE PLAN SHEETS TO REFLECT SAME | | LOCATION AND/OR NUMBER OF DEVICES. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE ON THE PLAN EACH COMMENT WAS | | ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2007-11-06 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-11-06 |
Time |
23:25 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-11-01 |
Time |
10:13 |
Sent To |
|
|
Notes |
2007-11-01 10:57:58 | *****DENIED***** | | | | 01.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 02.THE ADDRESS OF THE PROJECT SITE SHALL BE IN THE | | TITLE BLOCK OF EACH SUBMITTED PLAN SHEET. | | | | 03.THE PROPOSED FIRE HYDRANTS SHALL BE INSTALLED, | | COMPLETED, AND IN SERVICE PRIOR TO CONSTRUCTION WORK. | | ADD TO HYDRANT INFORMATION, SHEET C-5. | | | | 04.LANDSCAPING SHALL NOT INTERFERE OR HINDER ACCESS | | TO FIRE PROTECTION EQUIPMENT AND DEVICES. | | | | 05.ON THE LIFE SAFETY SHEET (LS-1) IN THE OCCUPANT | | LOAD REFERENCE,THE OCCUPANT LOAD OF 81 LISTED DOES | | NOT CORRELATE WITH 71 AS COMPUTED BY THIS WRITER. | | | | 06.SPECIFY THE WALL AND CEILING FINISH MATERIALS FOR | | EXITS, EXIT AISLE CORRIDORS, AND OTHER SPACES IN TERMS | | OF CLASS A, CLASS B, OR CLASS C. | | | | 07.ON THE APPROPIATE EXTERIOR ELEVATION, POST THE | | NUMERICAL ADDRESS ON THE BUILDING.AS PER WEST PALM | | BEACH CODE, THE NUMBERS SHALL BE NO LESS THAN 6" IN | | HEIGHT AND NO LESS THAN 1" IN WIDTH.PLEASE BE ADVISED | | THAT THE INSTALLATION OF HURRICANE SHUTTERS SHALL NOT | | OBSCURE OR BLOCK VISIBILITY OF THE ADDRESS NUMBERS. | | | | 08.ON THE APPROPIATE EXTERIOR ELEVATION, SHOW THE | | LOCATION OF THE KNOX BOX.FOR APPLICATIONS, CONTACT | | WEST PALM BEACH FIRE PREVENTION BUREAU AT | | 561-804-4724. | | | | 09.PROVIDE PRESCRIPTIVE STRENGHTS FOR THE STAIR | | HANDRAILS/GUARD RAILS. | | | | 10.ON SHEET A-9 DOOR SCHEDULE NOTE #1 IS UNCLEAR AND | | INCORRECT.CLARIFY BY CHAPTER AND SECTION AS PER | | REFERENCING NFPA 101- 2003 EDITION. | | | | 11.SHOW THE LOCATION OF THE FIRE DEPARTMENT | | CONNECTION (FDC).THE FDC SHALL BE EQUIPPED WITH KNOX | | LOCKING CAPS.FOR APPLICATIONS, CONTACT WEST PALM | | BEACH FIRE PREVENTION BUREAU AT 561-804-4724. | | | | 12.ELECTRONIC SWITCHES, CHAIN AND LOCK SHALL BE | | REQUIRED ON THE FIRE LINE BACKFLOW DEVICE. | | | | 13.ON SHEET E-6, THERE ARE TWO EMERGENCY LIGHTS | | ILLUSTRATED ON THE SOUTH WALL OF THE WORKSHOP BUT ONLY | | ONE ILLUSTRATED ON SHEETS LS-1 AND A-2;PLEASE | | CORRELATE THE PLAN SHEETS TO REFLECT SAME LOCATION | | AND/OR NUMBER OF DEVICES. | | | | 14.ON SHEET E-6 AND LS-1 THERE IS AN EXIT LIGHT | | ILLUSTARATED IN THE OFFICE AREA HALLWAY BUT IS NOT | | SHOWN ON SHEET A-2;PLEASE CORRELATE THE PLAN SHEETS | | TO REFLECT SAME LOCATION AND/OR NUMBER OF DEVICES. | | | | 15.ON SHEET FA-1, DELETE REFERENCE IN NOTE #3 TO THE | | PALM BEACH COUNTY CODE. | | | | 16.ON SHEET FA-1, AMEND THE FIRE ALARM SEQUENCE OF | | OPERATIONS TO REFLECT THAT DUCT SMOKE DETECTORS | | INITIATE A GENERAL FIRE ALARM INSTEAD OF A SUPERVISORY | | ALARM. | | | | 17.THE NUMBER OF DEVICES ILLUSTRATED FOR ROOM 108 ON | | SHEET FA-2 DOES NOT CORRELATE WITH THE FIRE ALARM RISER | | SHOWN ON THE FA-3 SHEET. | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE ON THE PLAN EACH COMMENT WAS | | ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2009-09-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-09-29 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-09-29 |
Time |
15:49 |
Sent To |
|
|
Notes |
2009-09-30 15:48:44 | SENT TO ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2009-08-06 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-07-22 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-07-22 |
Time |
16:02 |
Sent To |
|
|
Notes |
2009-08-06 16:04:15 | C-37, RELOCATION OF HANDI CAP STALLS REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2009-07-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-07-29 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-07-29 |
Time |
08:45 |
Sent To |
|
|
Notes |
2009-07-29 08:45:35 | SENT TO K. STEVENS' DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2009-07-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-07-16 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-07-15 |
Time |
11:24 |
Sent To |
|
|
Notes |
2009-07-16 11:25:36 | STRUCTURAL REVISIONS TO JWITMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2009-07-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-07-14 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-07-14 |
Time |
14:06 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2009-06-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-06-22 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-06-22 |
Time |
09:55 |
Sent To |
|
|
Notes |
2009-06-22 09:55:45 | TO C42 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2009-05-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-05-05 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-05-05 |
Time |
14:07 |
Sent To |
E |
|
Notes |
2009-05-05 14:08:00 | TO DVP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2009-01-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-01-27 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-01-27 |
Time |
08:18 |
Sent To |
E |
|
Notes |
2009-01-27 08:18:37 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-11-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-11-07 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-11-07 |
Time |
15:05 |
Sent To |
|
|
Notes |
2008-11-07 15:08:19 | TO "COMM" BD#23/PLANS ON RACK/1 ROLL, LARGE FOLDED | | PLANS/BINDERS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-08-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-21 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-21 |
Time |
10:51 |
Sent To |
|
|
Notes |
2008-08-21 10:52:04 | TO "COMM" BD#45 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-05-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-05-13 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-05-13 |
Time |
12:31 |
Sent To |
|
|
Notes |
2008-05-13 12:31:50 | TO "COMM" BD#26 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-12-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-12-01 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-09-20 |
Time |
08:34 |
Sent To |
|
|
Notes |
2007-10-12 16:28:10 | TO "COMM" BD#45 | 2007-09-20 08:35:06 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2009-07-20 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-07-20 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-07-20 |
Time |
15:46 |
Sent To |
PC |
|
Notes |
2009-07-20 16:06:27 | REVISED M1 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2008-11-22 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-11-22 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-11-22 |
Time |
14:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2008-09-04 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-09-04 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-09-03 |
Time |
16:25 |
Sent To |
|
|
Notes |
2008-09-04 09:26:39 | TEMPORARY FAIL: | | | | MISSING ONE SET OF ENERGY CALCULATIONS AND 2 SETS OF | | COOLING LOAD CALCULATIONS. SPOKE TO KEVIN. IF MISSING | | DOCUMENTS ARE PROVIDED PRIOR TO COMPLETION OF ALL | | REVIEWS, THEY WILL BE INCORPORATED INTO THE SUBMITTAL | | AND MECHANICAL REVIEW WILL PASS. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2008-05-28 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-05-28 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-05-27 |
Time |
16:11 |
Sent To |
|
|
Notes |
2008-05-28 16:25:50 | REVIEW #: 2ND **1ST REVIEW FOR PERMIT** | | ACTION: DENIED | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | 1. OK EXCEPT: PRODUCT APPROVALS SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL IN ACCORDANCE | | WITH FBCB 106.3.3. | | | | 2 THROUGH 9: OK | | | | 10. ENERGY CALCULATIONS: ON THE CERTIFICATIONS PAGE OF | | THE COMPLIANCE FORM, THE BUILDING SHELL AND | | ELECTRICAL/LIGHTING DESIGNERS HAVE NOT CERTIFIED | | COMPLIANCE WITH THE ENERGY CODE. DESIGN PROFESSIONALS | | RESPONSIBLE UNDER FLORIDA LAW FOR THE DESIGN OF | | LIGHTING, ELECTRICAL, MECHANICAL, AND PLUMBING SYSTEMS | | AND THE BUILDING SHELL, SHALL CERTIFY COMPLIANCE OF | | THOSE BUILDING SYSTEMS WITH THE CODE BY SIGNING AND | | PROVIDING THEIR PROFESSIONAL REGISTRATION NUMBER ON THE | | ENERGY CODE FORM PROVIDED AS PART OF THE PLANS AND | | SPECIFICATIONS TO THE BUILDING DEPARTMENT, OR: | | TYPED NAMES AND REGISTRATION NUMBERS MAY BE PROVIDED IN | | LIEU OF A SIGNATURE WHERE ALL RELEVANT INFORMATION HAS | | BEEN INCLUDED ON SIGNED AND SEALED PLANS IN ACCORDANCE | | WITH FBCB 13-103.1.1.1. SHOW COMPLIANCE BY PROVIDING | | ONE OF THE TWO REQUIREMENTS LISTED ABOVE. | | | | THE FOLLOWING ARE EXAMPLES OF AREAS IN THE INPUT DATA | | REPORT (IDR) WHICH DO NOT CORRESPOND WITH THE SYSTEMS | | AND ASSEMBLIES SHOWN ON PLANS. THIS IS NOT AN | | EXHAUSTIVE LIST. PLEASE VERIFY ALL VALUES TO ENSURE | | THEY CORRESPOND WITH PLANS AND RESUBMIT. | | | | A) A/C SYSTEM #3 AND RELATED ENVELOPE COMPONENTS ARE | | NOT INCLUDED IN THE IDR OR SYSTEM SIZING SUMMARY. | | PLEASE CORRECT AND RESUBMIT. | | | | B) EXTERIOR BLOCK WALL (P-2 PARTITION DETAIL PG A-10) | | DOES NOT CALL FOR ANY INSULATION. THE IDR IS CALLING | | FOR 1 INCH INSULATION AT THESE WALLS. | | | | C) THERE ARE NO DOORS INCLUDED IN THE IDR. | | | | 11. SEE COMMENT (A) ABOVE. | | | | 12 AND 13: OK | | | | NEW: THE MECHANICAL PAGES, WHILE SIGNED AND SEALED BY | | JOSE M. MARTINEZ, HAVE THE PRINTED NAME AND LICENSE | | NUMBER OF PAUL F. HILLERS DIRECTLY BELOW THE SIGNATURE | | AND SEAL OF MR. MARTINEZ. AS THE PRINTED NAME AND | | LICENSE NUMBER OF MR. MARTINEZ APPEARS IN THE TITLE | | BLOCKS ON THE SAME PAGES, MR. HILLER?S NAME CAN BE | | STRUCK FROM THE PLANS AND THE PLANS WILL BE COMPLIANT. | | | | NOTE: ASIDE FROM THE ABOVE LISTED COMMENTS, THE | | MECHANICAL PLANS HAVE BEEN REVIEWED FOR CODE COMPLIANCE | | AND STAMPED. REVIEW WILL REMAIN IN FAILED STATUS | | PENDING SUCCESSFUL REVIEW OF ENERGY CALCULATIONS BY ALL | | AFFECTED TRADES. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-11-10 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-11-10 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-11-09 |
Time |
17:46 |
Sent To |
|
|
Notes |
2007-11-10 11:24:02 | REVIEW #: 1ST | | ACTION: DENIED | | | | *NOTE* THIS PLAN SUBMITTED FOR PLAN REVIEW ONLY. NO | | PERMIT APPLICATION HAS BEEN SUBMITTED AT THIS TIME. | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | 1. WALL LOUVERS ARE LISTED AS PANEL WALLS UNDER FAC | | RULE 9B-72 AND AS SUCH A PRODUCT APPROVAL IS REQUIRED. | | PROVIDE PRODUCT APPROVALS FOR EACH TYPE OF WALL LOUVER | | TO BE USED. FOR MORE INFORMATION ON THE FLORIDA PRODUCT | | APPROVAL SYSTEM PLEASE VISIT: WWW.FLORIDABUILDING.ORG | | | | 2. M-1: SUPPLY REGISTERS FOR ELECTRICAL ROOM 107 AND | | MECHANICAL ROOM 108 ARE SHOWN TO BE FED FROM THE RETURN | | DUCT FOR AHU-2. ALSO, THE RETURN GRILL FOR ELECTRICAL | | ROOM 107 IS SHOWN BEING TIED INTO THE SUPPLY BRANCH | | FROM AHU-2 WHICH FEEDS CONFERENCE ROOM 104. PLEASE | | CLARIFY HOW EACH DUCT IS SUPPOSED TO FUNCTION. FBC,M | | 603.1 AND FBC 106.1.1 | | NOTE: DUE TO THE ABOVE DISCREPANCIES, AIR BALANCES ON | | THESE SYSTEMS CAN NOT BE REVIEWED AT THIS TIME. | | | | 3. M-1: SUPPLY AND RETURN DUCTS CROSSING CORRIDOR AT | | ROOMS 109 AND 110 ARE SHOWN WITH 3 OUT OF 4 DUCT | | PENETRATIONS OF WALLS PROTECTED WITH FIRE DAMPERS. ARE | | THESE WALLS INTENDED TO BE FIRE RESISTANCE RATED? THEY | | ARE NOT SHOWN AS SUCH BASED ON THE WALL TYPE AS SHOWN | | ON PAGES A-1 AND A-10. PLEASE COORDINATE THE LOCATIONS | | OF RATED ASSEMBLIES WITH ARCHITECTURAL DESIGNER, | | SHOWING OPENING PROTECTIVES WHERE REQUIRED IN | | ACCORDANCE WITH FBC,M 607.5. | | NOTE: IF IT IS DETERMINED THAT THESE WALLS REQUIRE A | | RATING, SHOW ALL 4 PENETRATIONS TO BE PROTECTED IN | | ACCORDANCE WITH THIS SECTION AND FBC,M 607.8. | | | | 4.M-1: EF-3 ON FLOOR PLAN CALLS FOR 690 CFM. FAN | | SCHEDULE ON M-3 SHOWS EF-3 AT 640 CFM. WHICH IS | | CORRECT? VERIFY THAT FAN CAN PROVIDE THE MINIMUM | | VENTILATION AS REQUIRED BY FBC,M TABLE 403.3 FOR LOCKER | | ROOMS, TOILET ROOMS AND SHOWERS. COORDINATE FLOOR PLANS | | WITH EQUIPMENT SCHEDULES. | | | | 5. M-2: WHAT IS THE MEANS AND LOCATION OF CONDENSATE | | DISPOSAL? AHU MOUNTING DETAIL SAYS TO SEE PLUMBING | | PLANS FOR CONTINUATION. NO INFORMATION REGARDING | | LOCATION OF CONDENSATE DISCHARGE COULD BE FOUND ON | | PLUMBING PLANS. SHOW CONDENSATE DISPOSAL FOR AHU?S 1,2 | | AND 6 TO BE IN COMPLIANCE WITH FBC,M 307.2.1 THROUGH | | 307.2.4 AND FBC 1503.6. | | | | 6. M-2: FIRE DAMPER DETAIL CALLS FOR ANGLES TO BE | | FASTENED TO SLEEVE PER SMACNA RECOMMENDATIONS. FIRE | | DAMPERS ARE LISTED AND LABELED ASSEMBLIES AND AS SUCH | | SHALL BE INSTALLED PER THEIR LISTING AND MANUFACTURER?S | | INSTALLATION INSTRUCTIONS IN ACCORDANCE WITH FBC,M | | 607.2. UNLESS THIS DETAIL MATCHES THE MANUFACTURER?S | | INSTRUCTIONS IT SHOULD BE REMOVED FROM PLANS AND | | REPLACED BY THE MANUFACTURER?S INSTRUCTIONS EITHER ON | | THE PLANS OR AS A SEPARATE SUBMITTAL. IT MAY BE | | REPLACED BY A GENERAL NOTE WHICH DEFERS TO | | MANUFACTURER?S INSTRUCTIONS. | | | | 7. M-3: A/C UNIT SCHEDULE, CFM SHOWN ON SCHEDULE FOR | | AHUS DO NOT MATCH THOSE ON FLOOR PLAN. COORDINATE FLOOR | | PLANS AND EQUIPMENT SCHEDULE. ALSO, SEE COMMENT #2 | | ABOVE. | | | | 8. A/C UNIT SCHEDULE NOTE #3 INDICATES AHU-3 SHALL BE | | OF DOUBLE WALL CONSTRUCTION. NO AHU-3 IS SHOWN ON PLANS | | OR SCHEDULE. PLEASE CLARIFY. FBC 106.1.1. | | | | 9. M-3 O.A. SCHEDULE SHOWS AHU-1 SYSTEM DESIGNED FOR | | 460 CFM. A/C UNIT SCHEDULE INDICATES AHU-1 TO PROVIDE | | 965 CFM OF O.A. WHICH IS CORRECT? PLEASE CLARIFY AND | | COORDINATE SCHEDULES. | | | | 10. PROVIDE AN ENERGY CODE COMPLIANCE CERTIFICATION | | FORM (ENERGY CALCULATIONS) IN ACCORDANCE WITH FBC | | 13-101.1.1 AND FBC 13-103 (ENTIRE SECTION). | | | | 11. COOLING LOAD CALCULATIONS SHALL BE ATTACHED TO THE | | CODE COMPLIANCE FORM SUBMITTED TO THE BUILDING | | DEPARTMENT AT TIME OF PERMIT APPLICATION IN ACCORDANCE | | WITH FBC 13-407.1.ABC.1 AND ALL HVAC SYSTEMS AND | | EQUIPMENT SHALL BE SIZED TO PROVIDE NO MORE THAN THE | | SPACE AND SYSTEM LOADS CALCULATED IN ACCORDANCE WITH | | FBC 13-407.1.ABC.1.1. | | | | 12. AHU?S 1 AND 2 SHALL BE PROVIDED WITH OFF-HOUR | | CONTROLS INCLUDING AUTOMATIC SHUTDOWN, SETBACK | | CONTROLS, OPTIMUM START CONTROLS, SHUTOFF DAMPER | | CONTROLS AND ZONE ISOLATION IN ACCORDANCE WITH FBC | | 13-407.1.ABC.2.4. | | | | 13. PROVIDE AN AIR BALANCE SCHEDULE SHOWING THE | | BUILDING TO BE PRESSURIZED WITH RESPECT TO THE OUTDOORS | | IN ACCORDANCE WITH FBC 13-409.1.ABC.2. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
9 |
Status |
N |
Date |
2009-08-10 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-08-10 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-08-10 |
Time |
14:25 |
Sent To |
|
|
Notes |
2009-08-10 14:26:56 | IRRIGATION SHEETS SUBMITTED FOR REVISION SHOW NO | | IRRIGATION CHANGES. REVISION INDEX INDICATES PARKING | | LOT STRIPING ONLY. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
8 |
Status |
P |
Date |
2009-07-30 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-07-30 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-07-30 |
Time |
16:01 |
Sent To |
|
|
Notes |
2009-07-30 16:02:00 | REVISION OK -- SHT P-2. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
7 |
Status |
F |
Date |
2009-07-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-07-22 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-07-22 |
Time |
08:47 |
Sent To |
|
|
Notes |
2009-07-22 08:51:12 | REVISION DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | | | 1. SHT P-2 SANITARY RISER DIAGRAM DOES NOT REFLECT THE | | FLOOR PLAN. THE FLOOR DRAIN SOUTH OF COL. LINE 4.5 | | ALONG COL. LINE E IS NOT SHOWN ON THE RISER DIAGRAM, | | BUT IS SHOWN ON THE FLOOR PLAN ON SHEET P-1. PLEASE | | CORRELATE. SECTIONS 106.1.1 & 301.3. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2009-07-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-07-22 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-07-22 |
Time |
08:47 |
Sent To |
|
|
Notes |
2009-07-22 08:47:51 | REVISION OK -- SHT P-1. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2009-07-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-07-13 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-07-13 |
Time |
16:19 |
Sent To |
|
|
Notes |
2009-07-13 16:56:53 | REVISION DENIED | | REFERENCE: | | FBC-2004 CHAPTER 1 ADMIN | | | | 1. SHT P-1 ON FILE FOR PUBLIC RECORD SHOWS A REVISION | | NUMBER 2 DATED SEPTEMBER 3, 2008 AND IS SIGNED, SEALED, | | & DATED 10-14-2008. THE REVISION SUBMITTED FOR REVIEW | | SIGNED, SEALED AND DATED 6-17-09 IS SHOWING A REVISION | | NUMBER 2 DATED JUNE 16, 2009. THE REVISION HISTORY | | SUBMITTED FOR PUBLIC RECORD SHALL BE LEFT INTACT THRU | | THE PROJECT LIFE AND NEW REVISIONS SHALL HAVE NEW | | REVISION NUMBERS. SECTION 106.1.3. | | | | 2. SHT P-2 ON FILE FOR PUBLIC RECORD SHOWS A REVISION | | NUMBER 1 DATED JUNE 13, 2008 AND A REVISION NUMBER 2 | | DATED SEPTEMBER 3, 2008 AND IS SIGNED, SEALED & DATED | | 11-4-08. THE REVISION SUBMITTED FOR REVIEW SIGNED, | | SEALED AND DATED 6-17-09 IS SHOWING NO REVISION NUMBER | | ONE IN THE REVISION HISTORY, AND REVISION NUMBER 2 | | DATED JUNE 16, 2009. THE REVISION HISTORY SUBMITTED FOR | | PUBLIC RECORD SHALL BE LEFT INTACT THRU THE PROJECT | | LIFE AND NEW REVISIONS SHALL HAVE NEW REVISION NUMBERS. | | SECTION 106.1.3. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2008-12-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-12-03 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-03 |
Time |
08:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2008-08-27 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-08-27 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-08-21 |
Time |
15:55 |
Sent To |
|
|
Notes |
2008-08-27 11:25:12 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 BUILDING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | | | PLAN REVIEW ONLY | | | | ****FROM PREVIOUS REVIEW: | | | | 1. OK | | 2. OK | | 3. OK | | 4. OK | | 5. OK | | 6. OK | | 7. OK | | 8. OK | | 9. OK | | | | ***********NEW COMMENTS*********** | | | | NEW PLUMBING SHEETS SUBMITTED | | | | 1B. SHT P-2 SANITARY RISER ISOMETRIC DOES NOT REFLECT | | THE FLOOR PLAN. STACK WITH DOUBLE LAV'S P-3 SHOWS A | | TRAP TO THE STORAGE ROOM ON THE FLOOR PLAN THAT IS NOT | | ON THE RISER DIAGRAM.--THE FLOOR PLAN SHOWS A FLOOR | | DRAIN IN THE STORAGE AREA THAT CONNECTS UPSTREAM OF THE | | URINALS IN THE MEN'S ROOM 116 THAT IS NOT SHOWN ON THE | | RISER DIAGRAM. PLEASE CORRELATE. SECTIONS 106.1.1 & | | 704.--FLOOR DRAIN UPSTREAM OF THE URINALS APPEARS | | TO EXCEED THE MAXIMUM DISTANCE FROM THE VENT PER TABLE | | 906.1. | | | | 2B. SHT P-2 DOMESTIC WATER PIPING ISOMETRIC DOES NOT | | REFLECT THE FLOOR PLAN NOR DOES IT REFLECT THE PLUMBING | | FIXTURE SCHEDULE SHOWN ON SHT P-3. RISER SHOWS A | | FIXTURE P-9 DOWNSTREAM OF FIXTURE P-7 IN THE STORAGE | | (117) ROOM. THIS IS NOT SHOWN ON THE FLOOR PLAN NOR ON | | THE FIXTURE SCHEDULE. PLEASE CORRELATE. SECTIONS | | 106.1.1 & 604. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE ONE | | SET OF THEM LOOSELY ON TOP OF THE COLLATED | | PLANS TO BE REVIEWED. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2008-06-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-06-02 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-05-30 |
Time |
17:01 |
Sent To |
|
|
Notes |
2008-06-02 08:33:25 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 BUILDING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | | | PLAN REVIEW ONLY | | | | ****FROM PREVIOUS REVIEW: | | | | 1. OK | | 2. OK | | 3. OK | | 4. OK | | | | 5. PER SECTION 11-4.1.3(10)(B) WHERE MORE THAN ONE | | DRINKING FOUNTAIN IS PROVIDED, AT LEAST 50% SHALL BE | | ACCESSIBLE. 3 DRINKING FOUNTAINS ARE SHOWN, 2 SHALL BE | | ACCESSIBLE. | | ****RESPONSE NOTED, BUT THE TWO DRINKING FOUNTAINS IN | | THE CORRIDOR ARE HI/LOW AND AS SUCH ONLY THE LOW | | DRINKING FOUNTAIN IS ACCESSIBLE. THE HI DRINKING | | FOUNTAIN MEETS THE CODE REQUIREMENT FOR SECTION | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING. THE DRINKING FOUNTAIN | | IN THE WORKSHOP AREA SHALL BE ACCESSIBLE. THERE IS NO | | PROVISIONS IN THE CODE FOR EQUIVALENT PROVISIONS AT THE | | SINK IN THE LUNCH ROOM. PLEASE SHOW 2 OF THE 3 DRINKING | | FOUNTAINS TO BE ACCESSIBLE. (SUBMIT A DETAIL SHOWING | | COMPLIANCE WITH SECTION 11-4.15 WITH ALL SUBSECTIONS). | | | | 6. OK | | 7. OK | | 8. OK | | 9. OK | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE ONE | | SET OF THEM LOOSELY ON TOP OF THE COLLATED | | PLANS TO BE REVIEWED. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-12-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-12-01 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-12-01 |
Time |
10:17 |
Sent To |
|
|
Notes |
2007-12-01 10:38:45 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 BUILDING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | | | PLAN REVIEW ONLY | | | | 1. SHT A-1 ROOM FINISH SCHEDULE FOR ROOMS 113, 115 & | | 116. WALLS WITHIN 2 FEET OF WATER CLOSETS & URINALS | | SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE PER | | SECTION 1210.2. EPOXY PAINT OVER GWB IS NOT CONSIDERED | | A HARD SURFACE. PLEASE SHOW COMPLIANCE. | | | | 2. SHT A-1 INDICATE TYPE OF WORK WILL BE DONE IN THE | | WORKSHOP AND TYPE AND AMOUNT OF STORAGE IN THE STORAGE | | AREA. SECTION 106.1.2. | | | | 3. SHT A-7 SHOW COMPLIANCE WITH THE FOLLOWING: ___FOR | | THE URINAL: | | A. 11-4.18.4 FLUSH CONTROLS (HEIGHT) | | ___FOR LAVS: | | A. 11-4.19.5 FAUCETS | | ___FOR THE SHOWERS: | | A. 11-4.21.3 SEAT HEIGHT | | B. 11-4.21.5 CONTROLS | | C. 11-4.21.7 CURBS (MAX 1/2") | | | | 4. SHT A-8 SHOW COMPLIANCE WITH THE FOLLOWING: ___FOR | | SINKS: | | A. 11-4.24.4 SINK DEPTH | | B. 11-4.24.5 CLEAR FLOOR SPACE (FORWARD APPROACH | | REQUIRED). | | C. 11-4.24.6 EXPOSED PIPES & SURFACES | | D. 11-4.24.7 FAUCETS | | | | 5. PER SECTION 11-4.1.3(10)(B) WHERE MORE THAN ONE | | DRINKING FOUNTAIN IS PROVIDED, AT LEAST 50% SHALL BE | | ACCESSIBLE. 3 DRINKING FOUNTAINS ARE SHOWN, 2 SHALL BE | | ACCESSIBLE. | | | | 6. SHT P-1 THERE IS A NOTE THAT STATES 3" PVC PIPE FOR | | FUTURE USE. SEE CONT. ON CIVIL DRAWINGS. THE PIPE IS | | NOT SHOWN ON THE CIVIL PLANS. PLEASE CLARIFY WHAT THE | | PIPE WILL BE DRAINING AND TO WHERE. SECTION 106.1.2 | | (MORE INFORMATION REQUIRED). | | | | 7. SHT P-2 SANITARY RISER DIAGRAM DOES NOT REFLECT THE | | FLOOR PLAN. THE STACK WITH THE DRINKING FOUNTAIN AND | | SINK IN THE STORAGE/WORKSHOP AREA SHOWS 3 FIXTURES | | CONNECTING TO THE STACK ON THE FLOOR PLAN, BUT ONLY TWO | | FIXTURES, (P-9 & P-7), ON THE RISER DIAGRAM.--THE | | FLOOR DRAIN IN THE JANITOR ROOM IS NOT SHOWN ON THE | | RISER DIAGRAM BUT IS SHOWN ON THE FLOOR PLAN. PLEASE | | CLARIFY AND CORRELATE THE RISER WITH THE FLOOR PLAN. | | SECTION 106.1.1. | | | | 8. SHT P-2 AN RPZV BACKFLOW IS REQUIRED ON THE WATER | | SERVICE TO THE BUILDING. INDICATE THE BACKFLOW ON THE | | WATER RISER DIAGRAM PRIOR TO ENTERING THE BUILDING. | | SECTION 608.13.2. | | | | 9. THERMAL EXPANSION CONTROL IS REQUIRED PER SECTION | | 607.3.2. INDICATE METHOD. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE ONE | | SET OF THEM LOOSELY ON TOP OF THE COLLATED | | PLANS TO BE REVIEWED. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2009-10-05 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-10-05 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2009-10-05 |
Time |
13:19 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2009-07-29 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-07-29 |
Time |
15:48 |
Rev Time |
0.66 |
Received By |
eschneid |
Date |
2009-07-29 |
Time |
15:48 |
Sent To |
|
|
Notes |
2009-07-29 15:55:51 | FAILED HC RELOCATION REVISION | | | | 1) ZONING STAFF DOES NOT FIND A PROBLEM WITH THE | | RELOCATION OF THE HC SPACES. | | | | 2) ZONING STAFF HAS IDENTIFIED THE FOLLOWING ISSUES | | WITH THE SUBMITTED PLANS: | | | | A. THE PLANS SHALL MATCH THE CONDITIONS IN THE FIELD - | | EX. THERE IS A DRIVEWAY W/CURB CUT ADJACENT TO THE | | "GENERATOR ROOM" AT THE SOUTH EAST LIMITS OF WORK THAT | | IS NOT SHOWN ON THE PLANS. | | | | B. THE CONTRACTOR AND THE CITY'S LANDSCAPE PLANNER, | | ROBERT KUSSNER (561) 822-1462, DISCUSSED SOME POSSIBLE | | CHANGES TO THE PLANS DURING THE FIELD VISIT - | | SPECIFICALLY, SIDEWALK CONNECTIONS TO SOME OF THE | | LANDINGS ADJACENT TO THE EXISTING BUILDINGS. IF THE | | CONTRACTOR STILL WISHES TO INSTALL THESE CHANGES, THEY | | SHALL BE REFLECTED ON THE PLANS. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2008-09-02 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2008-09-02 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2008-09-02 |
Time |
16:23 |
Sent To |
|
|
Notes |
2008-09-02 16:25:25 | PASS W/PROVISO | | | | D-CURBS ARE REQUIRED TO BE INSTALLED IN THE LOCATIONS | | MARKED IN RED ON SHEETS C-1, C-2 AND LA-1 (ADJACENT TO | | PARKING). | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2008-06-13 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2008-06-13 |
Time |
17:19 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2008-06-13 |
Time |
13:10 |
Sent To |
|
|
Notes |
2008-06-13 17:23:04 | FAILED | | | | 1) NO LANDSCAPE PLAN SUBMITTED.THE LANDSCAPE PLAN | | SHALL ADHERE TO ALL THE REQUIREMENTS OF THE CITY'S | | LANDSCAPE REGULATIONS AND BE PREPARED BY A FLORIDA | | REGISTERED LANDSCAPE ARCHITECT. | | | | 2) THE PARKING DETAILS DO NOT CONFORM TO THE CITY | | STANDARD - WHEEL STOP SHALL BE TWO (2) FEET FROM END OF | | PARKING SPACE. | | | | 3) ALL LANDSCAPE ISLANDS (INTERIOR AND TERMINAL) SHALL | | HAVE A SHADE OR FLOWERING TREE. | | | | 4) THE AMOUNT OF FOUNDATION PLANTING IS NOT INDICATED. | | | | 5) NO PARKING TABLE IS PROVIDED. | | | | 6) NO LOADING SPACE PROVIDED. | | | | 7) ALL LANDSCAPE SHALL BE PROTECTED FROM VEHICLE | | ENCROACHMENT BY A TYPE ?D? CURB OR WHEEL STOPS.THIS | | STANDARD IS NOT MET ALONG MOST OF THE PAVEMENT EDGES. | | | | 8) WHERE IS DUMPSTER LOCATED/HOW IS TRASH DISPOSED OF? | | IF A DUMPSTER IS USED IT SHALL BE SCREENED MEETING WPB | | REQUIREMENTS. | | | | 9) ALL MECHANICAL EQUIPMENT, INCLUDING GENERATORS, | | SHALL BE SCREENED. | | | | 10) THANK YOU FOR PROVIDING A LETTER THAT THE BUILDING | | DOES NOT NEED TO GO THROUGH THE DEP CONDITIONS OF | | CERTIFICATION PROCESS.THIS DOES REQUIRE THAT THE | | BUILDING IS REVIEWED BY THE CITY THROUGH THE FORMAL | | SITE PLAN REVIEW PROCESS. | | | | CONTACT ERIC SCHNEIDER @ (569) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-10-22 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2007-10-22 |
Time |
20:19 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2007-10-22 |
Time |
20:19 |
Sent To |
|
|
Notes |
2007-10-22 20:43:48 | FAILED | | | | 1) THE CITY HAS NO RECORD THAT THIS PLAN WAS SUBMITTED | | FOR REVIEW BY THE PLANNING AND ZONING DEPARTMENT UNDER | | THE REQUIREMENTS OF CHAPTER 403, FLORIDA STATUTES. | | OPTIONS - A. SUBMIT THE APPROVED POWER PLANT | | CERTIFICATION, INCLUDING THE SITE PLAN SUBMITTED FOR | | WEST PALM BEACH REVIEW AND ALL COMMENTS GENERATED BY | | THE CITY DURING SAID REVIEW; OR OPTION B. SUBMIT THE | | PLAN FOR A FORMAL SITE PLAN REVIEW BY THE CITY. | | | | THE FOLLOWING IS A CURSORY REVIEW OF THE PLANS.A FULL | | REVIEW WILL OCCUR WITH THE FORMAL SUBMITTAL TO THE | | CITY. | | | | 1) NO LANDSCAPE PLAN SUBMITTED.THE LANDSCAPE PLAN | | SHALL ADHERE TO ALL THE REQUIREMENTS OF THE CITY'S | | LANDSCAPE REGULATIONS AND BE PREPARED BY A FLORIDA | | REGISTERED LANDSCAPE ARCHITECT. | | | | 2) THE PARKING DETAILS DO NOT CONFORM TO THE CITY | | STANDARD. | | | | 3) NO MORE THAN 10 PARKING SPACES MAY BE CONSTRUCTED IN | | A ROW UNLESS INTERRUPTED BY AN INTERIOR LANDSCAPE | | ISLAND. | | | | CONTACT ERIC SCHNEIDER @ (569) 822-1435. |
|
|