Plan Review Stops For Permit 07090519 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2008-05-17 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-05-17 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-05-17 |
Time |
07:41 |
Sent To |
|
|
Notes |
2008-05-17 07:43:15 | | | | | REVISION #2 WINDOW AND DOOR PRODUCT APPROVALS, (CHANGE | | OF MANUFACTURER) PASSED |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-05-17 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-05-17 |
Time |
06:35 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-05-17 |
Time |
06:35 |
Sent To |
PC |
|
Notes |
2008-05-17 06:37:55 | | | REVISION #1 BEAM CHANGE AT REAR PATIO, PASSED |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-05-08 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-05-08 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-05-08 |
Time |
16:56 |
Sent To |
PC |
|
Notes |
2008-05-08 17:02:02 | | | | | REVISION #1 DENIED | | | | 1)PROVIDE ATTACHMENT DETAIL OF LVL TO TOP OF BLOCK | | COLUMNS | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-01-03 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-01-03 |
Time |
18:22 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-01-03 |
Time |
18:22 |
Sent To |
PC |
|
Notes |
2008-01-03 18:32:01 | | | | | PASSED | | | | 1)PLEASE NOTE THAT NO CONNECTORS WERE STATED FOR THE | | GIRDER TRUSSES AND (2) HAVE UPLIFTS THAT EXCEED THAT OF | | THE HETAL POURED IN STRAPS ON THE DRAWINGS. | | | | 2)ONLY FRENCH DOOR PRODUCT APPROVALS WERE SUBMITTED | | BUT THE ENTRY DOOR TO THE GARAGE LOOKS TO BE A METAL | | PANEL DOOR, NO SCHEDULE WAS PRESENT ON THE DRAWINGS TO | | MAKE A DETERMINATION. IF A STEEL DOOR IS USED A | | REVISION WILL BE REQUIRED FOR THAT DOOR. | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-12-07 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-12-07 |
Time |
18:40 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-12-07 |
Time |
18:40 |
Sent To |
PC |
|
Notes |
2007-12-07 18:50:41 | | | | | DENIED | | | | 1)NO PRODUCT APPROVAL WAS SUBMITTED FOR THE ROOFING | | MATERIALS, PLEASE SUBMIT (2) COPIES FOR ROOF TILES | | | | 2)TRUSS ENGINEERING THAT WAS SUBMITTED IS NOT | | DESIGNED TO THE LOADS REQUIRED BY THE DESIGNER OF | | RECORD IN THE CONTRACT DOCUMENTS ON SHEET S.1 PLEASE | | CLARIFY | | | | 3)PLEASE KNOW THAT PER 713.13(2) F.S. IF THE | | IMPROVEMENT DESCRIBED IN THE NOC HAS NOT COMMENCED | | WITHIN 90 DAYS OF RECORDING, THE NOTICE IS VOID AND IS | | REQUIRED TO BE RE-RECORDED | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-10-09 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-10-09 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-10-09 |
Time |
15:47 |
Sent To |
PC |
|
Notes |
2007-10-09 16:35:59 | | | | | DENIED | | | | 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL | | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 | | AMENDMENTS PER 106.1.1 FBC* | | | | 2)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING | | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF | | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND | | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE | | DRAWINGS | | | | 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | PER 108.3 FBC* | | | | 4)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON | | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER | | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE | | ADDED TO THE PERMIT APPLICATION FEES | | | | NOTE: FEES ARE DUE IN THE AMOUNT OF $ FOR | | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS | | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW | | | | 5)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SETS OF PLANS MUST BE STAMPED BY THAT OFFICE, | | AND A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION. | | | | 6)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE | | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. | | ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG | | | | 7)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE | | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | 8)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | STATE PRODUCT APPROVAL COVER | | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON | | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT | | SUBMITTED APPLICATIONS WILL BE DENIED | | | | 9)NO PRODUCT APPROVALS WERE SUBMITTED FOR EXTERIOR | | DOORS, WINDOWS, GARAGE DOORS, LINTELS, MULLIONS FOR | | JOINED WINDOWS, ROOFING,CONNECTORS AND STRAPS (OR ADD | | FLORIDA PRODUCT APPROVAL NUMBERS TO THE CONNECTOR | | SCHEDULE), ETC. | | | | 10)A DESIGN PROFESSIONAL THAT IS REGISTERED TO | | PRACTICE UNDER CHAPTER 481 OR 471 OF THE FLORIDA | | STATUTES SHALL AFFIX THEIR OFFICIAL SEAL, SIGNATURE AND | | DATE TO SAID DRAWINGS AND SPECIFICATIONS PER 106.1 FBC | | 2004. THE EXEMPTION FROM LICENSURE UNDER 481.229 FS | | DOES NOT EXEMPT THE DESIGNER RESPONSIBLE FOR THE | | DRAWINGS FROM SIGNING AND DATING SAID DRAWINGS. | | | | 11)PROVIDE STRUCTURAL DETAIL FOR THE FRONT PORCH AREA | | THAT SHOWS POST TO BEAM CONNECTION AND BEAM TO WALL AT | | MAIN HOUSE, ETC. | | | | 12)REAR COLUMNS DO NOT SHOW BEAM ABOVE OR IT'S | | DIMENSIONS FOR SUPPORT OF ROOF | | | | 13)PROVIDE DETAIL OF GARAGE DOOR BUCK IF NOT STATED | | IN THE PRODUCT APPROVAL | | | | 14)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER | | AND OWNER/AGENT PRIOR | | TO SUBMITTAL | | | | 15)PROVIDE MIN. R-VALUE OF WALL AND CEILING | | INSULATION, BE SURE TO MATCH THE VALUES IN THE ENERGY | | CALC'S | | | | 16)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT | | COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR | | BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND | | APPROVED BY THE DESIGNER OF RECORD | | | | 17)PROVIDE ATTIC ACCESS ON DRAWINGS TO ALL AREAS AS | | REQUIRED PER R807.1 FBC RES. | | | | 18)PROVIDE AT MINIMUM 1 ACCESSIBLE BATHROOM PER | | R322.1.1 FBC | | | | 19)THE SOIL REPORT PERFORMED BY THE GEOTECHNICAL | | ENGINEER STATES A BEARING CAPACITY OF 2000 PSF AND THE | | BUILDING HAS BEEN DESIGNED ON AN ASSUMED BEARING OF | | 3000 PSF | | | | 20)PROVIDE DETAIL OF SEPARATION BETWEEN GARAGE AND | | RESIDENCE FOR WALLS AND DOOR PER R309.1 AND R309.2 FBC | | RES. | | | | 21)PROVIDE SIZE OF ATTIC VENTILATION THAT MEETS THE | | REQUIREMENTS OF R806.2 FBC RES. | | | | 22)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2008-12-30 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2009-01-13 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-12-30 |
Time |
08:28 |
Sent To |
PC |
|
Notes |
2008-12-30 08:57:47 | | | | | REVISION FOR SERVICE ONLY./WRT. | 2008-12-29 08:54:42 | SENT TO BT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2008-07-24 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-07-24 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-07-24 |
Time |
10:50 |
Sent To |
PC |
|
Notes |
2008-07-24 11:02:27 | | | | | | | | | NONCOMPLIANT/REVISION DENIED | | | | | | 1} THE ARCHITECTURAL FIRM WHO IS THE DESIGNER OF | | RECORD, MUST SIGN, SEAL AND DATE THE PLAN PER | | 481.221(1)(B)FS.HE MUST APPROVE ALL CHANGES TO HIS | | DESIGN. | | | | 2} THE GROUNDING ELECTRODE CONDUCTOR MUST COMPLY WITH | | 250.66, INDICATE SAME ON THE PLAN | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-12-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-12-28 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-12-28 |
Time |
09:12 |
Sent To |
P |
|
Notes |
2007-12-28 10:23:24 | | | *** REDLINED PLANS*** | | | | 1) THE CONDUIT AND CONDUCTORS FROM METER TO MAIN | | BREAKER PANEL SHALL BE INSTALLED UNDERGROUND/IN SLAB. | | 230.70, 230.71. | | IF THIS IS NOT DONE, A MAIN WITH OVER CURRENT | | PROTECTION WILL BE REQUIRED OUTSIDE ALONG WITH AN | | EQUIPMENT GROUNDING CONDUCTOR AFTER THE FIRST MEANS OF | | DISCONNECT. | | | | 2)KITCHEN WALL AS NOTED ON PREVIOUS REVIEW MUST MEET | | 210.52 FOR RECEPTACLE SPACING. RECEPTACLE SHOWN IS NOT | | WITHIN 6FT OF DOOR WAY. | | | | 3) PLANS SHOW TWO GARAGE DOOR OPENERS HOWEVER PANEL | | SCHEDULE ONLY SHOWS ONE CIRCUIT. | | PLEASE SEE 430.248 AS THE HP RATING OF EACH MOTOR MAY | | REQUIRE TWO SEPARATE CIRCUITS BEING DEDICATED. | | | | 4) LOW VOLTAGE SHOWN ON PLAN REQUIRES A SEPARATE | | PERMIT. PLANS SHOW PHONE AND CATV ONLY. | | MAY REFERENCE THESE PLANS FOR CATV AND PHONE. | | ANY OTHER SYSTEMS INSTALLED (IE: ) SPEAKERS, WILL | | REQUIRED PLANS/LAYOUT OF LOCATIONS. | | | | IF THERE ARE ANY QUESTIONS ON THE ABOVE PLEASE DO NOT | | HESITATE IN CONTACTING THIS REVIEWER DIRECTLY. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2007-11-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-11-20 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-11-20 |
Time |
08:45 |
Sent To |
M |
|
Notes |
2007-11-20 15:49:15 | ** DENIED 2ND REVIEW ** | | | | ** PLEASE KNOW AS PLANS ARE ONLY NOW BEING COMPLETED | | AND SUBMITTED FOR ELECTRICAL REVIEW THERE ARE SEVERAL | | NEW COMMENTS. THESE COMMENTS COULD NOT HAVE BEEN MADE | | ON PREVIOUS PLANS SUBMITTED.. | | | | 1) NOTE:PLEASE COMPLETE TITLE BLOCKS WITH LICENSE | | INFORMATION AND ADDRESS INFORMATION WHICH COORDINATES | | WITH THE STATE DEPARTMENT OF BUSINESS AND PROFESSIONAL | | REGULATION. | | PLEASE SEE IT SEEMS THE LAST NUMBER OF THE LICENSE | | NUMBER IS NOT BEING PRINTED ON SHEETS. THIS COULD HAVE | | BEEN REDLINED, HOWEVER PLANS WERE COMING BACK FOR OTHER | | COMMENTS. | | PLEASE SEE THE ADDRESS ON THE STATE SITE DOES NOT | | CORRELATE. (743 BISCAYNE ?) | | | | 2) NOTE: PLEASE SEE PLANS NOW INDICATE AND NEW SERVICE | | HOWEVER PLEASE SHOW THE LOCATION OF THE SERVICE | | EQUIPMENT ON PLANS. | | WE ARE UNABLE TO DETERMINE CODE COMPLIANCE WITH MANY | | ITEMS WITHOUT THESE SHOWN ON PLANS. | | 110.26, 240.24, 230.70, 230.71 ETC | | | | 3) NOTE: PLEASE SEE THE SCALE ON ELECTRICAL PLANS IS | | BEING SHOWN AS QUARTER INCH PER FOOT; HOWEVER THIS DOES | | NOT CORRELATE WITH THE REST OF THE PLANS/SHEETS. PLEASE | | SEE MECHANICAL PLANS FOR EXAMPLE AS THE SAME SCALE IS | | SHOWN YET THE LAYOUT IS SUBSTANTIALLY DIFFERENT. | | PLEASE KNOW THAT REVIEW FOR SOME ITEMS SUCH AS | | RECEPTACLE SPACING CAN NOT BE DONE AT THIS TIME. | | FBC 106.3.5.4, 106.3.1, 106.1 | | | | 4) NOTE: PLEASE SEE 210.52 AS SOME RECEPTACLES ARE | | MISSING FOR RULING. | | PLEASE SEE KITCHEN WALL FOR EXAMPLE WHERE NO | | RECEPTACLES ARE BEING SHOWN. (ONE LOCATION NOTED | | ONLY). | | | | 5) NOTE: PLEASE SEE RISER SHOWS AN EQUIPMENT GROUNDING | | CONDUCTOR FROM THE NEW METER TO THE FIRST MEANS OF | | DISCONNECT WHICH IS NOT PERMITTED. | | PLEASE SEE 240.24, 250.6. | | | | 6)NOTE: PLEASE SEE MISSING LOAD FOR DINING AS | | REQUIRED PER 210.52B1, 220.53. | | PLEASE SEE THAT ONE OR *MORE* OF THE REQUIRED CIRCUITS | | EACH REQUIRE 1500VA. | | | | 7) NOTE: PLEASE SEE 220.54 AS THE MINIMUM VA FOR THE | | DRYER SHALL BE 5KVA. | | (PLANS SHOW 4). | | | | 8) NOTE: PLEASE PLACE ALL ROOM AND AREA DESIGNATIONS ON | | PLANS. SOME ITEMS CAN NOT BE REVIEWED FOR CODE | | COMPLIANCE AT THIS TIME. | | | | 9) NOTE: PLEASE SEE THE PANEL SCHEDULE AND LOAD | | CALCULATIONS ARE MISSING THE REQUIRED DEDICATED | | CIRCUIT(S) FOR GDO/ GARAGE DOOR OPENERS. | | 430.148, 310.16, 240.4, 220. | | FBC 106.1.2 | | | | 10) NOTE: PLEASE VERIFY 350MCM FOR SERVICE ENTRANCE | | CONDUCTORS. THIS IS NOT A CODE ISSUE HOWEVER IF SHOWN | | AS 350MCM ON PLANS, THIS IS WHAT WILL BE REQUIRED TO BE | | INSTALLED. THIS IS ONLY NOTED FOR INFORMATION ONLY. | | | | 11) NOTE: PLEASE MAKE NOTE FOR SECTION OF FBC | | 13-606.1.ABC.1.2.4 FOR TYPE OF RECESSED LIGHTING | | FIXTURES. | | | | 12) NOTE: PLEASE SEE THERE ARE SOME LIGHTING FIXTURES | | ON PLANS WHICH DO NOT INDICATE ANY CONTROLS. | | PLEASE SEE FOR EXAMPLE WHAT APPEAR TO BE MASTER BEDROOM | | LIGHTS. | | FBC 106.1.2 | | | | 13) NOTE: PLEASE SEE 210.8A2 FOR REQUIRED GFI | | RECEPTACLES IN GARAGE. | | MISSING GFI DESIGNATION(S). | | | | 14) NOTE: PLEASE SEE 210.8A3 AS ALL RECEPTACLES OUTSIDE | | ARE ALSO REQUIRED TO BE GFI. PLEASE SEE MISSING | | DESIGNATIONS. | | | | 15) NOTE: PLEASE SEE WHAT APPEARS TO BE MISSING | | RECEPTACLE(S) PER 210.52C2 AND 4. | | PLEASE SEE THIS IS FOR WHAT IS SHOWN AS A SECOND | | ISLAND. | | PLEASE CLARIFY THE RECEPTACLE AS SHOWN. THIS IS SHOWN | | IN SINK OR UNDER SINK. | | THIS LOCATION, WALL, COUNTER SPACE IS UNCLEAR AT THIS | | TIME. | | | | ** PLEASE KNOW AS SOME ITEMS WERE NOT SHOWN AT THIS | | TIME, SOME ITEMS COULD NOT BE DETEMINED. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-09-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-09-23 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-09-23 |
Time |
09:16 |
Sent To |
M |
|
Notes |
2007-09-23 09:40:44 | | | ** DENIED** | | | | | | 1) NOTE:PLEASE KNOW THAT ANY PERMIT APPLICATIONS | | WHICH ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES | | PROJECTS UNDER THE NEW CODES ADOPTED BY THE STATE. | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | AFFECT DESIGNS FOR ALL TRADES. | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | REVIEWER AT A MINIMUM. | | 2004 FBC W/ 2006 REVISIONS | | 2005 NFPA-70 | | 2002 NFPA-72 | | 2003 NFPA-101 | | | | ** PLEASE KNOW THAT CHANGES FOR NEW CODES IS REQUIRED | | FOR ALL TRADES AND FOR ALL REVIEWS EVEN IF COMMENT IS | | NOT MADE BY OTHER TRADE(S). | | | | 2) NOTE: PLEASE SEE THAT ALL THREE SETS OF PLANS | | SUBMITTED ARE PHOTO-COPIES AND ARE NOT ORIGINAL SIGNED, | | DATED AND SEALED PLANS AS REQUIRED PER FS 481.221. | | ** PLEASE KNOW THAT FOR A SINGLE FAMILY DWELLING ONLY | | TWO SIGNED, DATED AND SEALED SETS ARE NEEDED. | | IF A THIRD SET IS DESIRED FOR STAMPING/DUPLICATE, THEN | | A THIRD SET OF SIGNED, DATED AND SEALED PLANS MAY BE | | PROVIDED FOR STAMPING. | | | | 3) NOTE: PLEASE ADJUST AND COMPLETE TITLE BLOCK WITH | | ALL LICENSE INFORMATION NEEDED. PLEASE SEE TITLE BLOCKS | | STILL INDICATE MR. LITTLE. THIS REVIEWER HAS BEEN IN | | CONTACT WITH MR. ROY FOR REQUIRED | | INFORMATION/ADJUSTMENTS. | | FAC 61G1-16.004, FS 481.219. | | | | 4) NOTE: PLEASE SUBMIT COMPLETED ELECTRICAL PLANS FOR | | REVIEW FOR CODE COMPLIANCE WITH THE PREVIOUS NOTED | | CODES ABOVE. PLEASE SEE NFPA-70 (NEC 2005) AND | | NFPA-72. | | ALL THREE SETS DO NOT CONTAIN ELECTRICAL PLANS. FBC | | 106.1.2, 106.1.3, 106.3.5.4 | | PLEASE PROVIDE PANEL SCHEDULE(S) WITH ALL MINIMUM | | REQUIRED CIRCUITS PER NEC. 408.4, 240.4, 310.16, | | 210.52, 210.11, 220, 215.5 ETC | | PLEASE PROVIDE ALL CONDUCTOR SIZES IN PANEL(S) ALONG | | WITH CONDUCTORS SIZES.240.4, 310.16 | | PLEASE PROVIDE A RISER DIAGRAM FOR NEW OR EXISTING | | PROPOSED SERVICE COMPLETE WITH ALLCONDUCTOR SIZES, | | CONDUITS, FEEDERS, GROUNDING, AIC RATINGS AND OVER | | CURRENT PROTECTION DEVICES. | | 230.70, 230.71, 1100.9, 230.72, 230.76, 230.79, 310.16, | | 250.50, 240.4 ETC | | PLEASE PROVIDE ALL SMOKE ALARM LOCATIONS INSIDE AND | | OUTSIDE ALL SLEEPING ROOMS PER NFPA-72 11.5.1.1, | | 11.8.3. FBC R313, FBC 905.2, ETC. | | PLEASE PROVIDE ALL RECEPTACLE LOCATIONS REQUIRED PER | | ALL OF 210.52 | | PLEASE PROVIDE ALL LIGHTING AND CONTROL LOCATIONS PER | | 210.70, LS 101 7.8. | | PLEASE BE SURE TO PROVIDE LISTING OF ALL ARC FAULT | | PROTECTED CIRCUITS PER 210.12. | | PLEASE PROVIDE ALL DISCONNECTING MEANS FOR EQUIPMENT AS | | REQUIRED. 440.11, 422.30, 422.31. | | PLEASE PROVIDE LOAD CALCULATIONS FOR ALL ELECTRICAL | | FROM NEW OR EXISTING SERVICE. NEC 220.**PLEASE BE SURE | | TO SEE THE NEW 2005 CODE WITH RESPECT TO WATER HEATERS | | TO BE FIGURED AT 125% PER 422.13. | | PLEASE SUBMIT ENERGY CALCULATIONS PER FBC CHAPTER 13. | | PLEASE BE SURE TO REFERENCE ANY RECESSED LIGHTING PER | | FBC 13-606.1.ABC.1.2.4 FOR *AIR MOVEMENT* ALLOWANCES | | FROM CONDITIONED SPACE. | | | | ** PLEASE SEE SOME OF THE ITEMS REFLECT ABOVE ARE IN NO | | WAY ALL ITEMS IN THE NEC WHICH WILL BE REVIEWED. | | THE ITEMS ABOVE ARE FOR ITEMS NEEDED, AS EACH DWELLING | | AND SCOPE OF WORK VARIES AND PLANS WERE NOT SUBMITTED | | FOR REVIEW IT IS NOT POSSIBLE TO GIVE CODE COMPLIANT | | REVIEW AT THIS TIME. | | PLEASE KNOW THERE MAY VERY WELL BE NEW COMMENTS ON THE | | FOLLOWING REVIEW WHICH COULD NOT BE MADE AT THIS TIME. | | **IF THERE ARE ANY QUESTIONS PLEASE DO NOT HESITATE IN | | CONTACTING THIS OFFICE. | | | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES | | WHICH MAY AFFECT ELECTRICAL PLANS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2009-01-23 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-01-23 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-01-23 |
Time |
15:30 |
Sent To |
P |
|
Notes |
2009-01-23 15:31:04 | ROUTED TO LWAGNER DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2008-12-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-12-22 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-12-22 |
Time |
16:56 |
Sent To |
E |
|
Notes |
2008-12-22 16:57:03 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2008-12-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-12-18 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-12-18 |
Time |
11:18 |
Sent To |
M |
|
Notes |
2008-12-18 11:18:56 | TO "M" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2008-12-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-12-18 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-12-18 |
Time |
09:50 |
Sent To |
M |
|
Notes |
2008-12-18 09:51:39 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2008-11-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-11-25 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-11-25 |
Time |
10:38 |
Sent To |
P |
|
Notes |
2008-11-25 10:38:47 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2008-09-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-02 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-02 |
Time |
16:00 |
Sent To |
Z |
|
Notes |
2008-09-02 16:00:41 | TO "Z" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2008-07-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-01 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-01 |
Time |
11:38 |
Sent To |
E |
|
Notes |
2008-07-01 11:38:59 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2008-06-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-06-17 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-06-17 |
Time |
16:24 |
Sent To |
M |
|
Notes |
2008-06-17 16:24:32 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-05-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-05-14 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-05-14 |
Time |
11:18 |
Sent To |
B |
|
Notes |
2008-05-14 11:20:20 | TO "AMORSE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-05-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-05-14 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-05-14 |
Time |
09:19 |
Sent To |
B |
|
Notes |
2008-05-14 09:20:03 | TO "AMORSE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-04-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-30 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-30 |
Time |
11:06 |
Sent To |
B |
|
Notes |
2008-04-30 11:07:06 | TO "AMORSE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-12-26 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-12-26 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-12-26 |
Time |
15:23 |
Sent To |
Z |
|
Notes |
2007-12-26 15:23:31 | TO ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-11-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-14 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-14 |
Time |
16:34 |
Sent To |
Z |
|
Notes |
2007-11-14 16:34:50 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-10-09 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-20 |
Time |
08:33 |
Sent To |
|
|
Notes |
2007-09-20 08:33:40 | TO "SFR" "Z" |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
P |
Date |
2008-12-18 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2008-12-18 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2008-12-18 |
Time |
13:12 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2008-12-18 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2008-12-18 |
Time |
12:58 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2008-12-18 |
Time |
12:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2008-06-20 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-06-20 |
Time |
08:00 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-06-20 |
Time |
08:00 |
Sent To |
|
|
Notes |
2008-06-20 08:11:51 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | REVISION TO MECHANICAL PLAN. | | *** DENIED *** | | | | 1) THE MECHANICAL PLAN ON FILE IS SIGNED AND SEALED BY | | AN ARCHITECT (STEPHEN M. ROY) SO ONLY HE CAN MAKE | | REVISIONS TO THEM, PER FAC 61G1-16.003. | | | | 2) THE ENERGY CALCULATIONS WILL NEED TO BE REVISED AS | | THE AIR HANDLER IS NOW INSTALLED IN THE GARAGE, PER | | 2004 FBC 13-600.3.ABC.2. PLEASE SUBMIT WITH PLAN | | REVISION. | | | | 3) SHOW ON THE MECHANICAL PLAN HOW RETURN AIR IS | | GETTING BACK TO THE AIR HANDLER, PER 2004 FBC/R | | M1602.4. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-11-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-11-26 |
Time |
10:42 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-11-26 |
Time |
10:42 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-09-24 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-09-24 |
Time |
08:57 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-09-24 |
Time |
08:57 |
Sent To |
P |
|
Notes |
2007-09-24 09:12:52 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) MECHANICAL PLAN PAGE M.1 THE BUILDING AND ROOM | | LAY-OUT IS FADED AND DIFFICULT TO READ, PLEASE CORRECT. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, SEE F.B.C. | | 106.1.1. | | | | 2) NEED TO SHOW THE SIZE AND CFM'S FOR THE SUPPLY AIR | | GRILL IN THE FAMILY ROOM. | | | | 3) SUBMIT ENERGY CALCULATIONS, SEE FBC 13.101.2. | | | | 4)SUBMITCOOLING LOAD CALCULATIONS, SEE 2004 FBC | | 13-607.1.ABC.1. | | | | 5)SUBMIT MANUAL D CALCULATIONS FOR RESIDENTIAL DUCT | | DESIGN, SEE 2004 FBC/R M1601.1 AND FBC 13-610.1.ABC.1. | | | | 6) THE ARCHITECT NEEDS TO SIGN AND SEAL THE PLANS, SEE | | F.A.C. 61G1-16.003. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2009-01-23 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2009-01-23 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2009-01-23 |
Time |
16:04 |
Sent To |
|
|
Notes |
2009-01-23 16:44:03 | REVISION OK- SAN. ISO. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2009-01-13 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2009-01-13 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2009-01-13 |
Time |
09:59 |
Sent To |
|
|
Notes |
2009-01-13 10:07:12 | REVISION DENIED: | | ORIGINAL ISOMETRIC DRAWING SEALED BY STEPHEN ROY . | | PLANS REQUIRED TO BE SIGNED, | | DATED AND SEALED BY THE ARCHITECT, | | PLEASE SEE FS 481.221 AND FAC 61G1-16 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-12-31 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-12-31 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-12-31 |
Time |
10:01 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-12-06 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-12-06 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-12-06 |
Time |
14:19 |
Sent To |
B |
|
Notes |
2007-12-06 14:31:05 | DENIED; | | 1. THE ARCHITECTURE FURM IS REQUIRED TO SHOW CORPS. | | CERTIFICATION NUMBER IN TITLE BLOCK. FBC BUILDING | | SECTION 106.1. | | 2.BATHROOM AND 1/2 BATH DOWN STREAM OF THE KITCHEN | | NOT VENTED TO CODE. SEE FBC PLUMBING SECTION 909.1. THE | | SINKS CANNOT GO THREW THE BATHROOM GROUP. | | 3. THE AUTOMATIC CLOTHES WASHER IS STILL NOT VENTED. | | SHOW VENT ON SANITARY RISER DIAGRAM. ( SEE ONE P.1 PAGE | | IS MARKED IN RED) | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-10-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-10-03 |
Time |
08:24 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-10-03 |
Time |
08:24 |
Sent To |
B |
|
Notes |
2007-10-03 08:31:24 | DENIED; | | 1. SEE ELECTRICAL PLAN REVIEW'S NOTES 2 & 3. | | 2. RISER DIAGRAM AND FLAT DRAWING DONOT MATCH. | | 3. A 2 WAY CLEANOUT IS MISSING ON FLAT DRAWING ( MARKED | | ON PLANS IN RED) A CLEANOUT IS ALSO REQUIRED ON W/M | | VENT AT 48" AFF. | | 4. VENTS MISSING FROM RISER DIAGRAM ( MARKED IN RED) | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2008-09-07 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2008-09-07 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2008-09-07 |
Time |
12:23 |
Sent To |
|
|
Notes |
2008-09-07 12:36:18 | ***ZONING FAILED*** | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | INCLUDES THE PROPERTYS ADDRESS AND LEGAL DESCRIPTION. | | | | 3. INDICATE THE DIMENSIONS OF THE PROPOSED DRIVEWAY AND | | WALKWAY (EXISTING AND PROPOSED) LOCATED WITHIN THE | | FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT | | BUILDING FACADE). | | | | 4. A TREE REMOVAL/RELOCATION PERMIT SHALL BE REQUIRED. | | PLEASE CONTACT ROBERT KUSSNER, LANDSCAPE PLANNER, AT | | (561) 822-1462 FOR FURTHER INFORMATION OF THE | | APPLICATION PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1444 OR (561) 805-6720 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-12-28 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-12-28 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-12-28 |
Time |
08:35 |
Sent To |
E |
|
Notes |
2007-12-28 08:36:12 | ***APPROVED - RESUB #2*** | | | | | | | | SENT TO "E" - DP |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-11-16 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-11-16 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-11-16 |
Time |
10:50 |
Sent To |
E |
|
Notes |
2007-11-16 10:57:05 | ***FAILED - RESUB #1*** | | | | | | 1)LANDSCAPING INSUFFICIENT.MUST MEET MINIMUM | | REQUIREMENTS SET FORTH IN SECTION 94-442 OF THE CITY OF | | WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | REGULATIONS. | | | | INCLUDING, BUT NOT LIMITED TO:ALL LANDSCAPED OPEN | | SPACE SHALL BE COVERED WITH GRASS, GROUND COVER, | | SHRUBBERY, OR OTHER SUITABLE PLANT MATERIAL.FOR | | SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE SHADE, | | FLOWERING OR FRUIT TREE SHALL BE PLANTED FOR EACH 1,200 | | SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. FOR | | SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE SHRUB SHALL | | BE PLANTED FOR EACH 500 SQUARE FEET OF OPEN SPACE OR | | PORTION THEREOF.PLANT MATERIALS USED PURSUANT TO THE | | PROVISIONS OF THIS SECTION SHALL BE EQUAL TO OR BETTER | | THAN FLORIDA DEPARTMENT OF AGRICULTURE NUMBER 1 NURSERY | | GRADE STANDARD.SHADE, FLOWERING AND FRUIT TREES. | | SHADE, FLOWERING AND FRUIT TREES PLANTED PURSUANT TO | | THE PROVISIONS OF THIS SECTION SHALL BE A MINIMUM OF | | EIGHT FEET IN HEIGHT, AND POSSESS A MINIMUM OF FIVE | | FEET OF CLEAR TRUNK SPACE.SHRUBS FOR GENERAL | | LANDSCAPE PURPOSES PLANTED PURSUANT TO THE PROVISIONS | | OF THIS SECTION SHALL BE A MINIMUM PLANT CONTAINER SIZE | | OF TWO GALLONS. | | | | NOTE:PALM TREES DO NOT COUNT AS SHADE/FLOWERING | | TREES. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2009-01-13 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-09-20 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-09-20 |
Time |
16:44 |
Sent To |
E |
|
Notes |
2007-09-20 16:51:05 | ***FAILED*** | | | | | | 1)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS:RENOVATIONS, REPAIR, | | ALTERATION OR REDEVELOPMENT WHICH EXCEEDS 50 PERCENT OF | | THE VALUE OF THE STRUCTURE SHALL BE BROUGHT TO | | COMPLIANCE WITH REGARD TO LANDSCAPING. | | PLEASE PROVIDE A LANDSCAPE PLAN SHOWING COMPLIANCE WITH | | SECTION 94-442 OF THE ZONING AND LAND DEVELOPMENT | | REGULATIONS. | | | | 2)PLEASE PROVIDE ALL DRIVEWAY DIMENSIONS AND SQUARE | | FOOTAGE OF ALL IMPERMEABLE SURFACE WITHIN THE FRONT | | YARD, IF DRIVEWAY IS TO BE INCLUDED IN THE SCOPE OF | | WORK FOR THIS PERMIT. | | | | 3)PROVIDE AN EASEMENT CONSENT FORM FROM THE CITY'S | | DEPARTMENT OF PUBLIC UTILITIES (1ST FLOOR, CITY HALL) | | FOR THE EAST AND WEST SITE WALLS. | | | | 4)INDICATE ELEVATION DIMENSIONS FROM GRADE RATHER | | THAN FINISHED FLOOR. | | | | 5)WESTERN SITE WALL SHALL BE SHOWN ON SITE PLAN | | (A.0). | | | | 6)INDICATE SETBACK DIMENSIONS FROM ANY PROPOSED A/C | | EQUIPMENT TO THE PROPERTY LINES. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|