Plan Review Details - Permit 07090500
Plan Review Stops For Permit 07090500
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-11-21 Cont ID  
Sent By amorse Date 2007-11-21 Time 18:25 Rev Time 0.00
Received By amorse Date 2007-11-21 Time 18:25 Sent To Z
Notes
2007-11-21 18:29:23 
  
 PASSED
  
 WINDOW BESIDE DOOR AT CARPORT DOES NOT MEET PRESSURE
 REQUIREMENTS WITH THE MINIMUM GLASS TYPE (A) AND WILL
 WORK WITH ANY OTHER GLASS TYPE IN THE PRODUCT APPROVAL
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-10-08 Cont ID  
Sent By amorse Date 2007-10-08 Time 17:07 Rev Time 0.00
Received By amorse Date 2007-10-08 Time 17:07 Sent To  
Notes
2007-10-08 17:35:23 
  
 DENIED
  
 1)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE.
 THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG.
 WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE
 DENIED. ****PLEASE SEE ONE COPY OF ATTACHED COVER
 SHEETS FOR STORM PANELS AND SINGLE HUNG WINDOWS****
  
 2)PRODUCT APPROVALS ARE REQUIRED FOR PGT MULLIONS
 (FL# 261-R3) WHERE TWO OR MORE WINDOW UNITS ARE
 ATTACHED TOGETHER
  
 3)THE NOA FOR THE EXTERIOR DOORS WAS SUBMITTED WITH
 THE INCORRECT DRAWINGS THAT BELONG TO IT PLEASE NOTE
 THAT THE MIAMI-DADE REPORT IS FOR GLAZED DOORS AND THEY
 HAVE NO IMPACT RATING AND WOULD THEREFORE REQUIRE
 SHUTTERS. THE FLORIDA STATEWIDE PRODUCT APPROVAL # FOR
 JELD WEN O/S STEEL DOORS WITH WOOD EDGES IS (FL#
 539-R3) AND THE MIAMI-DADE REPORT # 02-0712.06
  
 4)THE MIAMI-DADE REPORT FOR THE STORM PANELS HAS ALSO
 BEEN REVISED SEE THE ATTACHED UPDATED REPORT, PLEASE
 NOTE THAT THE ANCHOR SPACINGS HAVE CHANGED.
  
 5)SHUTTER SPANS ON THE INSTALLATION SCHEDULE ARE
 INCORRECT SPAN = OPENING HEIGHT (IF APPLIED VERTICALLY)
 PLUS 2 X E.D. (7") EG. OPENING # 1
 5'-3" + 7" SPAN = 5'-10" OR 70" PLEASE NOTE THAT 3 1/2"
 IS THE ED IF 3" IS USED THE ANCHOR SPACING WILL BE
 REDUCED BY MULTIPLYING BY THE FACTOR
 ON PAGE 7 OF 9 IN NOA
  
 6)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 PLEASE MAKE CORRECTIONS TO PRODUCT APPROVALS AND
 SHUTTER INSTALLATION SCHEDULE AND RESUBMIT
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-10-31 Cont ID  
Sent By btrobaug Date 2007-10-31 Time 07:50 Rev Time 0.00
Received By btrobaug Date 2007-10-31 Time 07:32 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-09-26 Cont ID  
Sent By btrobaug Date 2007-09-26 Time 16:12 Rev Time 0.00
Received By btrobaug Date 2007-09-26 Time 15:42 Sent To M
Notes
2007-09-26 16:12:04 
  
 APPLICATION # 07090500
 ELECTRICAL PLAN REVIEW
 1386 9TH COURT
  
 WEST PALM BEACH, FL.
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING
 CODE, 2005 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC
 AS
 AMENDED, CHAPTER 1, AND FOUND NONCOMPLIANT WITH THE
 FOLLOWING:
  
 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
 IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417
 FS, RESPECTIVELY.
 THE CONTRACTOR OF RECORD MAY BE THE DESIGN PROFESSIONAL
 IF EXEMPTIONS UNDER CHAPTER 471.003, FLORIDA STATUTES,
 IF EXEMPTIONS APPLY.
  
 2} PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT
 SIZE AND TYPE, GROUNDING DETAILS,PANEL SCHEDULES,
 SERVICE EQUIPMENT AND PANEL LOCATIONS PER 106.3.5.4
 FBC. 215.5NEC. NOTE #6 INDICATES A SERVICE TO A NEW
 SHED, INCLUDE ON THE RISER DIAGRAM. PHYSICALLY LOCATE
 ALL SERVICE EQUIPMENT ON THE PLAN.
  
 3} SHOW THE LOCATION OF THE A/C CONDENSER ON THE PLAN.
 ALSO SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER
 440.14,RECEPTACLE PER 210.63
  
 4} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE
 PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI
 PROTECTED PER 210.8(A) (1). INDICATE COMPLIANCE IN THE
 PANEL SCHEDULE.
  
 5} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH
 210.52(A), 210.52(C), AND 210.8(A)(6) GFI. INDICATE
 COMPLIANCE ON THE PLAN.
  
 6} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.1
 RESIDENTIAL FLORIDA BUILDING CODE. LOCATE ON THE PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-12-06 Cont ID  
Sent By adarroug Date 2007-12-06 Time 14:11 Rev Time 0.00
Received By adarroug Date 2007-12-06 Time 14:11 Sent To Z
Notes
2007-12-06 14:11:51TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-10-29 Cont ID  
Sent By adarroug Date 2007-10-29 Time 16:55 Rev Time 0.00
Received By adarroug Date 2007-10-29 Time 16:55 Sent To E
Notes
2007-11-28 11:23:28 
 ***EXPEDITED REVIEW. WPB HCD HOUSING***
 ***REHAB PROGRAM. 11/28/07. RB ***
2007-10-29 16:55:22TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-10-08 Time   Rev Time 0.00
Received By adarroug Date 2007-09-19 Time 09:32 Sent To  
Notes
2007-09-19 09:32:12TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-11-27 Cont ID  
Sent By tgordon Date 2007-11-27 Time 10:57 Rev Time 0.30
Received By tgordon Date 2007-11-27 Time 10:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-09-27 Cont ID  
Sent By tgordon Date 2007-09-27 Time 10:34 Rev Time 0.45
Received By tgordon Date 2007-09-27 Time 10:34 Sent To P
Notes
2007-09-27 11:14:13PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600A-04R, SEE
 FBC 13-600.3.A. OR YOU MAY SUBMIT FORM 600C-04R, SEE
 2004 FBC 13-101.2.3.
  
 2) WHEN RESUBMITTING ENERGY CALCULATIONS HAVE ADDRESS
 AND OTHER REQUIRED INFORMATION ON FRONT PAGE, SEE
 YELLOW HIGH LIGHTS ON OLD ENERGY CALCULATIONS. SEE
 W.P.B. AMEND. 106.1.3.
  
 3) ENERGY CALCULATIONS LINE #1 SHOWS CONSTRUCTION AS
 NEW, PLEASE CORRECT TO EXISTING OR RENOVATION, SEE FBC
 13-600.3.ABC.2.
  
 4) ENERGY CALCULATIONS LINE 11A SHOWS THE SUPPLY AIR
 DUCTS ARE IN A CONDITIONED SPACE, MECHANICAL PLANS SHOW
 THE SUPPLY AIR DUCTS TO BE IN ATTIC, PLEASE CORRECT
 ENERGY CAL'S.
  
 5) COOLING LOAD CALCULATIONS (MANUAL J) ARE CALLING FOR
 19,168 TOTAL BTU'S, THE A/C SYSTEM BEING INSTALLED ON
 THE MECHANICAL PLAN IS 28,000 TOTAL BTU'S. THE PLANS
 CAN ONLY CALL FOR 15% MORE TOTAL BTU'S THAN THE COOLING
 LOAD CAL'S, SEE FBC 13-607.1.ABC.1.1.PLEASE CORRECT.
  
 6) MECHANICAL PLANS, THE SUPPLY AIR DUCT TO THE KITCHEN
 NEEDS TO BE SIZED, SEE W.P.B. AMEND. 106.3.5.4 (10).
 PLEASE CORRECT.
  
 7) THE MECHANICAL PLANS NEED THE PRINTED NAME AND
 SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN, AND
 CONTRACTOR INFORMATION IF APPLICABLE ON THEM, SEE
 W.P.B. AMEND. 106.1.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-11-17 Cont ID  
Sent By jleech Date 2007-11-17 Time 14:04 Rev Time 0.00
Received By jleech Date 2007-11-17 Time 14:04 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-10-03 Cont ID  
Sent By jleech Date 2007-10-03 Time 10:14 Rev Time 0.00
Received By jleech Date 2007-10-03 Time 09:58 Sent To B
Notes
2007-10-03 10:37:35DENIED;
 MINIMUM PLUMBING FIXTURES, FBC-2004 PLUMBING TABLE
 403.1(R-3) REQUIRES A AUTOMATIC CLOTHES WASHER. NONE
 SHOWN ON PLANS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 2 Status P Date 2007-12-10 Cont ID  
Sent By choops Date 2007-12-10 Time 10:07 Rev Time 0.00
Received By choops Date 2007-12-10 Time 10:07 Sent To PC
Notes
2007-12-10 10:07:51***APPROVED - RESUB #2 (ZONING 2ND REVIEW)***

Review Stop Z ZONING
Rev No 1 Status F Date 2007-11-27 Cont ID  
Sent By choops Date 2007-11-27 Time 08:28 Rev Time 0.00
Received By choops Date 2007-11-27 Time 08:28 Sent To M
Notes
2007-11-27 08:30:24***FAILED - RESUB #1 (ZONING 1ST REVIEW)***
  
  
 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY SHOWING
 THE LOCATION OF THE PROPOSED A/C EQUIPMENT WITH SETBACK
 DIMENSIONS TO ALL PROPERTY LINES.NOTE:MAY NOT
 PROJECT MORE THAN 4' INTO A REQUIRED SETBACK.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720