Plan Review Stops For Permit 07090500 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-11-21 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-11-21 |
Time |
18:25 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-11-21 |
Time |
18:25 |
Sent To |
Z |
|
Notes |
2007-11-21 18:29:23 | | | | | PASSED | | | | WINDOW BESIDE DOOR AT CARPORT DOES NOT MEET PRESSURE | | REQUIREMENTS WITH THE MINIMUM GLASS TYPE (A) AND WILL | | WORK WITH ANY OTHER GLASS TYPE IN THE PRODUCT APPROVAL | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-10-08 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-10-08 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-10-08 |
Time |
17:07 |
Sent To |
|
|
Notes |
2007-10-08 17:35:23 | | | | | DENIED | | | | 1)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE. | | THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG. | | WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE | | DENIED. ****PLEASE SEE ONE COPY OF ATTACHED COVER | | SHEETS FOR STORM PANELS AND SINGLE HUNG WINDOWS**** | | | | 2)PRODUCT APPROVALS ARE REQUIRED FOR PGT MULLIONS | | (FL# 261-R3) WHERE TWO OR MORE WINDOW UNITS ARE | | ATTACHED TOGETHER | | | | 3)THE NOA FOR THE EXTERIOR DOORS WAS SUBMITTED WITH | | THE INCORRECT DRAWINGS THAT BELONG TO IT PLEASE NOTE | | THAT THE MIAMI-DADE REPORT IS FOR GLAZED DOORS AND THEY | | HAVE NO IMPACT RATING AND WOULD THEREFORE REQUIRE | | SHUTTERS. THE FLORIDA STATEWIDE PRODUCT APPROVAL # FOR | | JELD WEN O/S STEEL DOORS WITH WOOD EDGES IS (FL# | | 539-R3) AND THE MIAMI-DADE REPORT # 02-0712.06 | | | | 4)THE MIAMI-DADE REPORT FOR THE STORM PANELS HAS ALSO | | BEEN REVISED SEE THE ATTACHED UPDATED REPORT, PLEASE | | NOTE THAT THE ANCHOR SPACINGS HAVE CHANGED. | | | | 5)SHUTTER SPANS ON THE INSTALLATION SCHEDULE ARE | | INCORRECT SPAN = OPENING HEIGHT (IF APPLIED VERTICALLY) | | PLUS 2 X E.D. (7") EG. OPENING # 1 | | 5'-3" + 7" SPAN = 5'-10" OR 70" PLEASE NOTE THAT 3 1/2" | | IS THE ED IF 3" IS USED THE ANCHOR SPACING WILL BE | | REDUCED BY MULTIPLYING BY THE FACTOR | | ON PAGE 7 OF 9 IN NOA | | | | 6)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | PLEASE MAKE CORRECTIONS TO PRODUCT APPROVALS AND | | SHUTTER INSTALLATION SCHEDULE AND RESUBMIT | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-10-31 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-10-31 |
Time |
07:50 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-10-31 |
Time |
07:32 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-09-26 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-09-26 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-09-26 |
Time |
15:42 |
Sent To |
M |
|
Notes |
2007-09-26 16:12:04 | | | | | APPLICATION # 07090500 | | ELECTRICAL PLAN REVIEW | | 1386 9TH COURT | | | | WEST PALM BEACH, FL. | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING | | CODE, 2005 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC | | AS | | AMENDED, CHAPTER 1, AND FOUND NONCOMPLIANT WITH THE | | FOLLOWING: | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417 | | FS, RESPECTIVELY. | | THE CONTRACTOR OF RECORD MAY BE THE DESIGN PROFESSIONAL | | IF EXEMPTIONS UNDER CHAPTER 471.003, FLORIDA STATUTES, | | IF EXEMPTIONS APPLY. | | | | 2} PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT | | SIZE AND TYPE, GROUNDING DETAILS,PANEL SCHEDULES, | | SERVICE EQUIPMENT AND PANEL LOCATIONS PER 106.3.5.4 | | FBC. 215.5NEC. NOTE #6 INDICATES A SERVICE TO A NEW | | SHED, INCLUDE ON THE RISER DIAGRAM. PHYSICALLY LOCATE | | ALL SERVICE EQUIPMENT ON THE PLAN. | | | | 3} SHOW THE LOCATION OF THE A/C CONDENSER ON THE PLAN. | | ALSO SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER | | 440.14,RECEPTACLE PER 210.63 | | | | 4} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE | | PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI | | PROTECTED PER 210.8(A) (1). INDICATE COMPLIANCE IN THE | | PANEL SCHEDULE. | | | | 5} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH | | 210.52(A), 210.52(C), AND 210.8(A)(6) GFI. INDICATE | | COMPLIANCE ON THE PLAN. | | | | 6} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.1 | | RESIDENTIAL FLORIDA BUILDING CODE. LOCATE ON THE PLAN. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-12-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-12-06 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-12-06 |
Time |
14:11 |
Sent To |
Z |
|
Notes |
2007-12-06 14:11:51 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-10-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-29 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-29 |
Time |
16:55 |
Sent To |
E |
|
Notes |
2007-11-28 11:23:28 | | | ***EXPEDITED REVIEW. WPB HCD HOUSING*** | | ***REHAB PROGRAM. 11/28/07. RB *** | 2007-10-29 16:55:22 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-10-08 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-19 |
Time |
09:32 |
Sent To |
|
|
Notes |
2007-09-19 09:32:12 | TO "E" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-11-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-11-27 |
Time |
10:57 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-11-27 |
Time |
10:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-09-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-09-27 |
Time |
10:34 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2007-09-27 |
Time |
10:34 |
Sent To |
P |
|
Notes |
2007-09-27 11:14:13 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600A-04R, SEE | | FBC 13-600.3.A. OR YOU MAY SUBMIT FORM 600C-04R, SEE | | 2004 FBC 13-101.2.3. | | | | 2) WHEN RESUBMITTING ENERGY CALCULATIONS HAVE ADDRESS | | AND OTHER REQUIRED INFORMATION ON FRONT PAGE, SEE | | YELLOW HIGH LIGHTS ON OLD ENERGY CALCULATIONS. SEE | | W.P.B. AMEND. 106.1.3. | | | | 3) ENERGY CALCULATIONS LINE #1 SHOWS CONSTRUCTION AS | | NEW, PLEASE CORRECT TO EXISTING OR RENOVATION, SEE FBC | | 13-600.3.ABC.2. | | | | 4) ENERGY CALCULATIONS LINE 11A SHOWS THE SUPPLY AIR | | DUCTS ARE IN A CONDITIONED SPACE, MECHANICAL PLANS SHOW | | THE SUPPLY AIR DUCTS TO BE IN ATTIC, PLEASE CORRECT | | ENERGY CAL'S. | | | | 5) COOLING LOAD CALCULATIONS (MANUAL J) ARE CALLING FOR | | 19,168 TOTAL BTU'S, THE A/C SYSTEM BEING INSTALLED ON | | THE MECHANICAL PLAN IS 28,000 TOTAL BTU'S. THE PLANS | | CAN ONLY CALL FOR 15% MORE TOTAL BTU'S THAN THE COOLING | | LOAD CAL'S, SEE FBC 13-607.1.ABC.1.1.PLEASE CORRECT. | | | | 6) MECHANICAL PLANS, THE SUPPLY AIR DUCT TO THE KITCHEN | | NEEDS TO BE SIZED, SEE W.P.B. AMEND. 106.3.5.4 (10). | | PLEASE CORRECT. | | | | 7) THE MECHANICAL PLANS NEED THE PRINTED NAME AND | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN, AND | | CONTRACTOR INFORMATION IF APPLICABLE ON THEM, SEE | | W.P.B. AMEND. 106.1.3. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2007-11-17 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-11-17 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-11-17 |
Time |
14:04 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-10-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-10-03 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-10-03 |
Time |
09:58 |
Sent To |
B |
|
Notes |
2007-10-03 10:37:35 | DENIED; | | MINIMUM PLUMBING FIXTURES, FBC-2004 PLUMBING TABLE | | 403.1(R-3) REQUIRES A AUTOMATIC CLOTHES WASHER. NONE | | SHOWN ON PLANS. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-12-10 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-12-10 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-12-10 |
Time |
10:07 |
Sent To |
PC |
|
Notes |
2007-12-10 10:07:51 | ***APPROVED - RESUB #2 (ZONING 2ND REVIEW)*** |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-11-27 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-11-27 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-11-27 |
Time |
08:28 |
Sent To |
M |
|
Notes |
2007-11-27 08:30:24 | ***FAILED - RESUB #1 (ZONING 1ST REVIEW)*** | | | | | | 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY SHOWING | | THE LOCATION OF THE PROPOSED A/C EQUIPMENT WITH SETBACK | | DIMENSIONS TO ALL PROPERTY LINES.NOTE:MAY NOT | | PROJECT MORE THAN 4' INTO A REQUIRED SETBACK. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 |
|
|