Plan Review Stops For Permit 07090147 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-10-29 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-10-29 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-10-29 |
Time |
07:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-10-29 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-10-29 |
Time |
06:38 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-10-27 |
Time |
14:31 |
Sent To |
|
|
Notes |
2007-10-29 06:38:19 | | | BUILDING PLAN REVIEW | | PERMIT: 07090147 | | ADD: 1801 S. FLAGLER DR. #603 | | CONT: HAROLD M. GORDON & SONS, INC. | | TEL: (561)832- 3211 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW: 2ND 10/27/07 | | ACTION: DENIED | | | | 1) -- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | 2)NOTE: THE DRAWINGS SUBMITTED FOR THIS PROJECT DO | | NOT CORRESPOND WITH EACH OTHER. THERE ARE DIFFERENT | | INFORMATION AND A DIFFERENT FLOOR LAYOUT ON EACH | | DRAWING. TWO IDENTICAL SETS OF DRAWINGS SHALL BE | | SUBMITTED CONTAINING THE SAME INFORMATION AND FLOOR | | LAYOUT. | | | | 3)OK | | | | 4)OK | | | | **NOTE** | | THE UNIT NUMBER ON THE APPLICATION IS #603 AND THE | | DRAWINGS SUBMITTED INDICATES UNIT #817. CLARIFY. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-09-19 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-09-19 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-09-19 |
Time |
13:36 |
Sent To |
|
|
Notes |
2007-09-19 15:27:19 | BUILDING PLAN REVIEW | | PERMIT: 07090147 | | ADD: 1801 S. FLAGLER DR. #603 | | CONT: HAROLD M. GORDON & SONS, INC. | | TEL: (561)832- 3211 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW: 1ST | | ACTION: DENIED | | | | 1) -- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | 2)NOTE: THE DRAWINGS SUBMITTED FOR THIS PROJECT DO | | NOT CORRESPOND WITH EACH OTHER. THERE ARE DIFFERENT | | INFORMATION AND A DIFFERENT FLOOR LAYOUT ON EACH | | DRAWING. TWO IDENTICAL SETS OF DRAWINGS SHALL BE | | SUBMITTED CONTAINING THE SAME INFORMATION AND FLOOR | | LAYOUT. | | | | 3)ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE DESIGN. FBC 106.1.2* THE | | DRAWINGS SUBMITTED SHALL BE HAVE THE PRINTED NAME AND | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DRAWINGS. | | IF AN ENGINEER OR ARCHITECT IS RESPONSIBLE, HE/SHE | | SHALL AFFIX THEIR SEAL TO SAID DRAWINGS, AND MEET THE | | REQUIREMENTS OF FS 481 AND 471. | | | | 4)FBC 106.3.3*.THE PRODUCT APPROVALS SHALL BE | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. HI-LIGHT | | OR CIRCLE WHICH TYPE OF DOOR WILL BE INSTALLED FROM | | FL#8111. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2007-10-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-10-25 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-10-25 |
Time |
08:54 |
Sent To |
|
|
Notes |
2007-10-25 08:55:28 | PLANS NOW SHOW ONLY WORK FOR OTHER THAN ELECTRICAL. | | NO ELECTRICAL PERMIT APPLIED FOR AND NO ELECTRICAL IN | | SCOPE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-09-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-09-13 |
Time |
07:45 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-09-13 |
Time |
07:33 |
Sent To |
|
|
Notes |
2007-09-13 07:45:32 | | | ** DENIED ** | | | | 1) NOTE: PLEASE BE SURE TO STATE THE RELEVANT CODES ON | | PLANS | | 2004 FBC W/2006 REVISIONS. | | 2002 NFPA-72 | | 2005 NFPA-70 | | | | 2) NOTE: PLEASE SEE FBC RESIDENTIAL CODE R313 AS ANY | | NEW WORK IN UNIT IS REQUIRED TO HAVE THE SMOKE ALARMS | | BROUGHT UP TO CODE MEETING NFPA-72 11.5.1.1.1. IF THESE | | CURRENTLY ARE MEETING THE LATEST EDITION OF NFPA-72 | | PLEASE INDICATE THESE ON PLANS. | | | | 3) NOTE: PLEASE SEE NEC 210.12 FOR NEW INSTALLED FOR | | ARC FAULT PROTECTION. | | | | 4) NOTE: PLEASE SEE PLANS INDICATE NEW OVEN, COOK-TOP | | AND MICROWAVE HOWEVER NO INFORMATION ON THE ELECTRICAL | | IS SHOWN. WILL BE THIS BE NEW CIRCUITS, RECEPTACLES? IF | | SO, PLEASE SUBMIT A PANEL SCHEDULE WITH THE MINIMUM | | CONDUCTOR SIZES, OVER CURRENT PROTECTION AND EXISTING | | LOAD WITH NEW LOAD ON PANEL. | | IF THIS IS GOING TO BE FROM EXISTING CIRCUITS, PLEASE | | INDICATE. | | 408.4, 310.16, 240.4, | | FBC 106.3.5.4, 106.3.5.1.2, 106.1.2 | | | | 5) NOTE: PLEASE KNOW EVEN WHEN SCOPE OF WORK FALLS | | UNDER THE EXCEPTIONS OF 471 AND 481 OF THE FLORIDA | | STATUTES, THE SCOPE OF WORK STILL REQUIRES THE PLANS TO | | CONTAIN A PRINTED NAME AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR PLANS. | | PLEASE SEE FS 481.229 HOWEVER AS THE SCOPE OF WORK AS | | APPLIED WILL REQUIRE AN ARCHITECT AT A MINIMUM. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-10-31 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2007-10-31 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2007-10-01 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-10-01 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-10-01 |
Time |
15:05 |
Sent To |
|
|
Notes |
2007-10-01 15:16:18 | *****UNSAT***** | | | | | | 1.THE NUMERICAL ADDRESS, INCLUDING THE SUITE, SHALL | | BE IN THE TITLE BLOCK OF THE SUBMITTED PLAN SHEET(S). | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 3.THE REMOVAL OF EXISTING AND/OR THE STOCKING OF NEW | | BUILDING MATERIALS & SUPPLIES SHALL IN NO WAY INTERFERE | | OR HINDER EXIT AISLE CORRIDOR ON THE SIXTH FLOOR OR THE | | BUILDING. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-10-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-18 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-18 |
Time |
10:40 |
Sent To |
|
|
Notes |
2007-10-24 16:58:43 | TO "BOB"#18 | 2007-10-18 10:40:24 | WAITING FOR "BOB" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-10-01 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-10-01 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-09-10 |
Time |
08:37 |
Sent To |
|
|
Notes |
2007-09-12 16:56:45 | TO "BOB"#18 | 2007-09-10 08:39:52 | WAITING FOR "BOB" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-09-17 |
Time |
10:24 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2007-09-17 |
Time |
10:24 |
Sent To |
|
|
Notes |
2007-09-17 10:25:04 | NO MECHANICAL PLANS SUBMITTED, AND NO | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | THIS TIME. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-10-31 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2007-10-31 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-09-18 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-09-18 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-09-18 |
Time |
09:04 |
Sent To |
|
|
Notes |
2007-09-18 09:23:08 | DENIED; | | 1. SHOW ON PLANS WHAT PLUMBING FIXTURES WILL BE CHANGED | | OUT. WHAT SIZE TUB WAS IN THE MASTER BATHROOM? IS THE | | SHOWER IN BATHROOM # 2 THE SAME SIZE? PLEASE MARK PLANS | | THE PLUMBING FIXTURES THAT WILL NOTBE CHANGED. NOT | | ENOUGH INFORMATION. | | 2. SEE ELECTRICAL PLAN REVIEW NOTE # 5. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2007-09-13 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-09-13 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-09-13 |
Time |
08:19 |
Sent To |
|
|
Notes |
2007-09-13 08:20:02 | *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|