Plan Review Details - Permit 07090118
Plan Review Stops For Permit 07090118
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2008-03-15 Cont ID  
Sent By amorse Date 2008-03-15 Time 10:17 Rev Time 0.00
Received By amorse Date 2008-03-15 Time 10:17 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2008-03-01 Cont ID  
Sent By amorse Date 2008-03-01 Time 12:48 Rev Time 0.00
Received By amorse Date 2008-03-01 Time 12:47 Sent To PC
Notes
2008-03-01 12:51:06 
  
 DENIED
  
 1)REVISION SAME NOA AS SUBMITTED IN ORIGINAL PERMIT
 APPLICATION, NEW FLORIDA STATEWIDE SHEETS FOR GULF
 COAST SUPPLY BUT NOA FOR UNION CORRUGATING COMPANY,
 PLEASE PROVIDE CORRECT NOA.
  
 *******PLEASE NOTE THAT CONTRACTOR WAS CALLED ON 2/1/08
 AND REVISION WAS HELD AT MY DESK AWAITING SUBMISION OF
 CORRECT NOA'S, AS OF 3/1/08 REVISION HAS BEEN DENIED
 AND CONTRACTOR SHALL RE SUBMIT********
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-11-16 Cont ID  
Sent By amorse Date 2007-11-16 Time 16:53 Rev Time 0.00
Received By amorse Date 2007-11-16 Time 16:53 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-11-03 Cont ID  
Sent By amorse Date 2007-11-03 Time 11:13 Rev Time 0.00
Received By amorse Date 2007-11-03 Time 11:11 Sent To PC
Notes
2007-11-03 11:13:25 
  
 DENIED
  
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM 1ST
 REVIEW:
  
 5)PROVIDE WIND DESIGN DATA ON DRAWINGS PER 1603.1.4
 FBC
 *******NOTE WIND EXPOSURE NOT PRESENT ON
 DRAWING*******
  
 6)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER
 AND OWNER/AGENT PRIOR TO SUBMITTAL.
 ********NOTE THE ENERGY CALC'S DO NOT STATE THE AREA OF
 NEW WALL R19 INSULATION, THE EAVE OVERHANG SIZE FOR THE
 ADDITION IS INCORRECT AND THEY ARE NOT SIGNED BY THE
 OWNER/AGENT.*******
  
 7)SUBMIT ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH
 R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE
 INSTALLATION THAT HAVE BEEN REVIEWED AND APPROVED BY
 THE DESIGNER OF RECORD. DRAWINGS TO BE SIGNED AND
 SEALED BY TRUSS ENGINEER.
 *******NOTE COMPLETE ORIGINAL SIGNED AND SEALED TRUSS
 DRAWINGS WILL BE REQUIRED FOR SITE INSPECTOR BEFORE
 INSPECTION*******
  
 8)PROVIDE PRODUCT APPROVAL FOR WINDOW MULLIONS OR IF
 SEPARATED BY STRUCTURE PROVIDE DETAIL.
 *******NOTE NO PRODUCT APPROVALS WERE SUBMITTED FOR
 WINDOW MULLIONS*******
  
 9)PRODUCT APPROVAL FOR THE HARDIPLANK SIDING REQUIRES
 HORIZONTAL FASTENING INTO WALL STUDS AT 16" O/C BUT
 WALL SECTION ON SHEET 2 SHOWS FRAMING AT 24" O/C
 ********NOTE DRAWINGS WERE NOT CHANGED TO REFLECT THE
 MAXIMUM SPACING OF THE FRAMING MEMBERS FOR THE SIDING
 PRODUCT OF 16" O/C*******
  
 11)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
 ********NOTE PRODUCT APPROVALS WERE NOT REVIEWED AND
 APPROVED BY THE PERSONS RESPONSIBLE FOR
 DRAWINGS********
  
 REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS OF
 NEW DRAWINGS AND INCLUDE 1 COPY OF THE OLD PAGES ONLY
 FOR REFERENCE, PLEASE DON NOT REMOVE SHEET WITH IMPACT
 FEE STAMP.
  
 NO NEW COMMENTS PENDING
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-09-29 Cont ID  
Sent By amorse Date 2007-09-29 Time 15:10 Rev Time 0.00
Received By amorse Date 2007-09-29 Time 15:10 Sent To PC
Notes
2007-09-29 15:31:46 
  
 DENIED
  
 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL
 COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006
 AMENDMENTS PER 106.1.1 FBC*
  
 2)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING
 MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF
 ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND
 STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE
 DRAWINGS
  
 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 4)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEE
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $179.53 FOR
 INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS
 REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW
  
 5)PROVIDE WIND DESIGN DATA ON DRAWINGS PER 1603.1.4
 FBC
  
 6)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER
 AND OWNER/AGENT PRIOR TO SUBMITTAL. PLEASE NOTE THAT
 CEILING R-VALUE DOES NOT MATCH DRAWINGS
  
 7)SUBMIT ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH
 R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE
 INSTALLATION THAT HAVE BEEN REVIEWED AND APPROVED BY
 THE DESIGNER OF RECORD. DRAWINGS TO BE SIGNED AND
 SEALED BY TRUSS ENGINEER.
  
 8)PROVIDE PRODUCT APPROVAL FOR WINDOW MULLIONS OR IF
 SEPARATED BY STRUCTURE PROVIDE DETAIL.
  
 9)PRODUCT APPROVAL FOR THE HARDIPLANK SIDING REQUIRES
 HORIZONTAL FASTENING INTO WALL STUDS AT 16" O/C BUT
 WALL SECTION ON SHEET 2 SHOWS FRAMING AT 24" O/C
  
 10)PRODUCT APPROVALS FOR PGT WINDOWS AND JELD-WEN
 DOOR REQUIRE CORRECTIONS, SEE NOTES ON THE PRODUCT
 APPROVALS.
  
 11)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 12)A RECORDED COPY OF THE NOTICE OF COMMENCEMENT IS
 REQUIRED PRIOR TO A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-10-26 Cont ID  
Sent By btrobaug Date 2007-10-26 Time 07:40 Rev Time 0.00
Received By btrobaug Date 2007-10-26 Time 07:30 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-09-14 Cont ID  
Sent By btrobaug Date 2007-09-14 Time 13:56 Rev Time 0.00
Received By btrobaug Date 2007-09-14 Time 13:49 Sent To P
Notes
2007-09-14 13:56:27 
 PROVISO
  
 R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
 REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING
 ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE
 INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE
 ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE
 ALARMS SHALL BE INTERCONNECTED AND HARD WIRED.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-04-16 Cont ID  
Sent By adarroug Date 2008-04-16 Time 11:35 Rev Time 0.00
Received By adarroug Date 2008-04-16 Time 11:35 Sent To M
Notes
2008-04-16 11:35:51TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-03-05 Cont ID  
Sent By adarroug Date 2008-03-05 Time 16:31 Rev Time 0.00
Received By adarroug Date 2008-03-05 Time 16:31 Sent To B
Notes
2008-03-05 16:31:31TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-02-08 Cont ID  
Sent By adarroug Date 2008-02-08 Time 08:17 Rev Time 0.00
Received By adarroug Date 2008-02-08 Time 08:17 Sent To B
Notes
2008-02-08 08:18:15TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-11-16 Cont ID  
Sent By adarroug Date 2007-11-16 Time 08:51 Rev Time 0.00
Received By adarroug Date 2007-11-16 Time 08:51 Sent To B
Notes
2007-11-16 08:51:39TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-10-19 Cont ID  
Sent By adarroug Date 2007-10-19 Time 16:41 Rev Time 0.00
Received By adarroug Date 2007-10-19 Time 16:41 Sent To Z
Notes
2007-10-19 16:41:16TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-09-29 Time   Rev Time 0.00
Received By adarroug Date 2007-09-07 Time 10:44 Sent To  
Notes
2007-09-07 10:45:06TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2007-10-26 Cont ID  
Sent By tgordon Date 2007-10-26 Time 09:17 Rev Time 0.20
Received By tgordon Date 2007-10-26 Time 09:17 Sent To P
Notes
2007-10-26 09:18:23NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-09-17 Cont ID  
Sent By tgordon Date 2007-09-17 Time 09:46 Rev Time 0.30
Received By tgordon Date 2007-09-17 Time 09:47 Sent To P
Notes
2007-09-17 09:55:06PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600A-2004R OR
 YOU MAY USE THE SHORT FORM 600C-2004R. SEE FBC
 13-600.3.A AND 13-600.3.C.
  
 2) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 3) COOLING LOAD CALCULATIONS WERE SUBMITTED BUT PLANS
 SHOW NO A/C WORK TO BE DONE, PLEASE REMOVE COOLING LOAD
 CAL'S OR SUBMIT A/C PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-11-01 Cont ID  
Sent By mperson Date 2007-11-01 Time 11:48 Rev Time 0.00
Received By mperson Date 2007-11-01 Time 11:48 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-09-17 Cont ID  
Sent By tgordon Date 2007-09-17 Time 09:47 Rev Time 0.00
Received By kstevens Date 2007-09-17 Time 14:53 Sent To  
Notes
2007-09-17 15:27:22DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 FUEL GAS
 FBC-2004 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. THE ENGINEER SHALL LEGIBLY INDICATE THEIR ADDRESS ON
 EACH SHEET. FAC 61G15-23.002(2) & FS 471.025. THE
 ADDRESS IN THE TITLE BLOCK DOES NOT REFLECT THE ADDRESS
 OF RECORD ON THE FLORIDA STATE DBPR WEBSITE. (SEE
 ATTACHED SHEET). PRIOR TO RESUBMITTING FOR REVIEW,
 EITHER UPDATE THE DBPR WEBSITE OR THE TITLE BLOCK OF
 THE ENGINEER SO THEY REFLECT.
  
 2. PLEASE INDICATE THE CODE REFERENCE ON THE PLANS TO
 WHICH THE PROJECT WILL BE DESIGNED AND BUILT. PRESENTLY
 WE HAVE ADOPTED THE FBC-2004 WITH 2005 & 2006
 REVISIONS. SECTION 106.1.1
  
 3. SHT 1/2 THE PLUMBING RISER DIAGRAM. PLEASE SHOW ALL
 PIPE SIZES. KEEP IN MIND SECTION 406.3 REQUIREMENT FOR
 MINIMUM 3" STACK OR BRANCH LINE TO THE W/M.--A
 CLEANOUT IS REQUIRED ON THE STACK PER SECTION 708.3.4,
 AND SHALL COMPLY WITH SECTION 708.9. .
  
 4. A SEPARATE GAS PERMIT IS REQUIRED. GAS PERMIT
 REQUIREMENTS FOLLOW:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
  
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE IF BEING USED.
  
 C. TYPE OF GAS, (LP OR NATURAL).
  
 D. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2004 FUEL GAS CODE SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU
 402.4(33). (THIS SHALL INCLUDE ALL EXISTING. SHOW ALL
 PIPE SIZES OF EXISTING).
  
 E. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4). (INCLUDING EXISTING).
  
 F. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2004 FUEL
 GAS CODE SECTION 304.
  
 G. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
  
 H. SUBMIT A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE AND TERMINATION OF THE
 GAS VENTS PER FBC-2004 FUEL GAS CODE
 SECS. 502 THRU 505.
  
 I. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2.
  
 J. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS, BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
  
 K. CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES
 PER NFPA 58. IF THE TANK
 IS BELOW GROUND THE CONTAINER SHALL BE
 SECURILY ANCHORED PER NFPA 58 SECTION 3-2.2.7(H).
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID
 SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY
 ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2007-10-25 Cont ID  
Sent By choops Date 2007-10-25 Time 10:34 Rev Time 0.00
Received By choops Date 2007-10-25 Time 10:34 Sent To E
Notes
2007-10-25 10:34:44***APPROVED - RESUB #1***
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 1 Status F Date 2007-09-11 Cont ID  
Sent By choops Date 2007-09-11 Time 08:20 Rev Time 0.00
Received By choops Date 2007-09-11 Time 08:20 Sent To E
Notes
2007-09-11 08:24:21***FAILED***
  
  
 1)INDICATE HEIGHT DIMENSIONS ON ELEVATIONS FROM
 GRADE TO THE MIDPOINT OF THE ROOF'S PITCH.
  
 2)PROVIDE A FLOOR PLAN SHOWING THE EXISTING
 STRUCTURE AND THE INTERCONNECTIVITY WITH THE NEW
 ADDITION.
  
 3)PROVIDE SETBACK DIMENSIONS FROM THE PROPOSED
 ADDITION TO ALL PROPERTY LINES.
  
 4)INDICATE THE CLOSEST DIMENSION FROM EXISTING
 ACCESSORY STRUCTURE TO THE PROPOSED ADDITION.
  
 5)SHOW A/C EQUIPMENT WITH SETBACK DIMENSIONS TO THE
 PROPERTY LINES...IF ANY ARE BEING PROPOSED/MOVED.
  
  
 NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720