Plan Review Details - Permit 07090070
Plan Review Stops For Permit 07090070
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-03-06 Cont ID  
Sent By kconrad Date 2008-03-06 Time 17:55 Rev Time 0.00
Received By kconrad Date 2008-03-06 Time 17:17 Sent To  
Notes
2008-03-06 18:01:20REVISED PROPOSED WINDOW INSTALLATION: WAS YALE OGRON
 SERIES 500 SINGLE HUNG WNDOW AND IS NOW YALE OGRON
 SERIES 1400 ALUMINUM CASEMENT WINDOW. CONTACTED EOR
 JOHN HOLT FOR APPROVAL: REVISION ACCEPTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-12-04 Cont ID  
Sent By kconrad Date 2007-12-04 Time 18:15 Rev Time 0.00
Received By kconrad Date 2007-12-04 Time 16:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-10-02 Cont ID  
Sent By kconrad Date 2007-10-02 Time 18:11 Rev Time 0.00
Received By kconrad Date 2007-09-27 Time 16:22 Sent To I
Notes
2007-09-27 16:36:34 
  
 PROJECT:614 32 STREET/#07090070
  
 PROJECT DETAIL: FAMILY ROOM ADDITION
  
 REVIEW: 2004 FLORIDA RESIDENTIAL CODE W/2006 REVISIONS
  
 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS
 CITY OF WEST PALM BEACH ADMINISTRATIVE CODE/2004
  
 STATUS: FAILED
  
 COMMENTS:
  
 1.)301.5 . A DESIGN PROFESSIONAL OR AN
 OWNER MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO SECTION
 303,304 & 305 OF THIS CODE.
  
 2) REQUIRE A NOTICE OF COMMENCEMENT AS PER THE
 FOLLOWING:
  
 FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) PROVIDE LEGIBLE SURVEYS: INDICATE LOCATIONS OF
 EXISTING AND PROPOSED CONCRETE SLAB CONSTRUCTION.
  
 4) PROVIDE PRODUCT APPROVALS FOR ALL ANCHORS/SIMPSON
 STRAPS.
  
 5) PLEASE SUBMIT THE INDICATED EPOXY SPECIFICATIONS.
  
 6) PLEASE SUBMIT SOIL BEARING REPORTS.
  
 7) PROVIDE ROOF FLASHING DETAILS FOR THE SLOPED /FLAT
 ROOF TRANSITION.
  
 8) PLEASE SELECT THE ROOF DECK TYPE AND PRODUCTS TO BE
 USED ON THE ROOFING PRODUCT APPROVAL. ADDITIONAL
 CALCULATIONS MAY BE REQUESTED AS PER LIMITATION #7/RAS
 117 OF THE APPLICABLE NOA.
  
 9) THE EAST AND WEST ELEVATIONS DO NOT REFLECT DETAIL
 A/A-1, SHEET A-2 WHICH SHOWS EXISTING OVERHANG OVER
 FLAT ROOF.
  
 10) INDICATE LUMBER DIMENSION OF THE WINDOW/DOOR
 HEADERS.
  
 11) SMOKE ALARMS SHALL BE PROVIDED AS PER THE FEBC,
 SECTION 904:
  
 904.1SMOKE ALARMS IN AN ADDITION.
 WHENEVER AN ADDITION IS MADE TO A BUILDING OR STRUCTURE
 OF A GROUP R-3 OR R-4 OCCUPANCY, HARDWIRED,
 INTERCONNECTED SMOKE ALARMS MEETING THE REQUIREMENTS OF
 THE FLORIDA BUILDING CODE, BUILDING OR THE FLORIDA
 BUILDING CODE, RESIDENTIAL SHALL BE INSTALLED AND
 MAINTAINED IN THE ADDITION.
  
 904.2SMOKE ALARMS IN EXISTING PORTIONS OF A
 BUILDING.
 WHENEVER AN ADDITION IS MADE TO A BUILDING OR STRUCTURE
 OF A GROUP R-3 OR R-4 OCCUPANCY, THE EXISTING BUILDING
 SHALL BE PROVIDED WITH SMOKE ALARMS AS REQUIRED BY THE
 FLORIDA BUILDING CODE, BUILDING OR THE FLORIDA BUILDING
 CODE, RESIDENTIAL AS APPLICABLE. THE SMOKE ALARMS IN
 THE EXISTING BUILDING ARE NOT REQUIRED TO BE
 INTERCONNECTED WITH SMOKE ALARMS IN OTHER PORTIONS OF
 THE BASE BUILDING.
  
 12) REQUIRE ENERGY CALCULATIONS AS PERTHE FEBC,
 SECTION 906:
  
 SECTION 906
 ENERGY CONSERVATION
 906.1MINIMUM REQUIREMENTS.
 ADDITIONS TO EXISTING BUILDINGS OR STRUCTURES SHALL
 COMPLY WITH THE REQUIREMENTS OF CHAPTER 13 OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 13) THE PRODUCT APPROVALS SUBMITTED ARE FOR DOUBLE
 DOORS; PLAN INDICATES A SINGLE 3068 DOOR.
  
  
 PLAN REVIEW: KEN CONRAD
 PHONE: 561.805.6666
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 PLAN REVIEW: KEN CONRAD
 PHONE: 561.805.6666
 E-MAIL: KCONRAD @WPB.ORG

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-12-11 Cont ID  
Sent By btrobaug Date 2007-12-11 Time 16:55 Rev Time 0.00
Received By btrobaug Date 2007-12-11 Time 16:27 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-11-16 Cont ID  
Sent By btrobaug Date 2007-11-16 Time 11:55 Rev Time 0.00
Received By btrobaug Date 2007-11-16 Time 11:34 Sent To M
Notes
2007-11-16 11:55:37 
  
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 THIS COMMENT FROM THE PREVIOUS REVIEW WAS NOT
 CORRECTED;
  
 1} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN,
 METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT
 COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED.*
 THESE NEED TO BE ON SHEET A2 WITH THE ELECTRICAL PLANS.
 ALSO THERE ARE NOW 2 PANEL "E"S IN THE DINING ROOM.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-09-14 Cont ID  
Sent By btrobaug Date 2007-09-14 Time 15:26 Rev Time 0.00
Received By btrobaug Date 2007-09-14 Time 15:01 Sent To M
Notes
2007-09-14 15:18:56 
  
  
  
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 1} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN,
 METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT
 COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED.
  
 2} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT
 CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE
 EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS
 EQUAL TO OR GREATER THAN THE AVAILABLE FAULT.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-03-04 Cont ID  
Sent By adarroug Date 2008-03-04 Time 11:00 Rev Time 0.00
Received By adarroug Date 2008-03-04 Time 11:00 Sent To B
Notes
2008-03-04 11:00:19TO "KCONRAD" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-01-17 Cont ID  
Sent By shill Date 2008-01-17 Time 15:56 Rev Time 0.00
Received By shill Date 2008-01-17 Time 15:56 Sent To M
Notes
2008-01-17 15:56:23TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-12-11 Cont ID  
Sent By btrobaug Date 2007-12-11 Time 16:28 Rev Time 0.00
Received By btrobaug Date 2007-12-11 Time 16:28 Sent To E
Notes
2007-12-11 16:28:31TO B.T./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-11-08 Cont ID  
Sent By adarroug Date 2007-11-08 Time 11:26 Rev Time 0.00
Received By adarroug Date 2007-11-08 Time 11:26 Sent To Z
Notes
2007-11-08 11:26:40TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-10-02 Cont ID  
Sent By kconrad Date 2007-10-02 Time 18:12 Rev Time 0.00
Received By kconrad Date 2007-09-06 Time 12:43 Sent To  
Notes
2007-09-06 12:43:22TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-01-18 Cont ID  
Sent By tgordon Date 2008-01-18 Time 10:37 Rev Time 0.35
Received By tgordon Date 2008-01-18 Time 10:37 Sent To  
Notes
2008-01-18 10:45:13** REVISION TO MECHANICAL PLAN **
 *** PROVISO ***
 1) IF DOOR TO AHU CLOSET OPENS INTO BATHROOM MEASURES
 MUST BE TAKEN TO PREVENT RETURN AIR BEING TAKEN FROM
 BATHROOM, SEE 2004 FBC/R M1602.2 (4).
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-11-16 Cont ID  
Sent By tgordon Date 2007-11-16 Time 14:52 Rev Time 0.30
Received By tgordon Date 2007-11-16 Time 14:52 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-09-17 Cont ID  
Sent By tgordon Date 2007-09-17 Time 09:00 Rev Time 0.30
Received By tgordon Date 2007-09-17 Time 09:00 Sent To P
Notes
2007-09-17 09:24:21PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) PERMIT APPLICATION STATES REPAIR BACK PORCH, BUT THE
 PLANS SHOW AN ENCLOSED ADDITION (NEW FAMILY ROOM AND
 LAUNDRY ROOM) PLEASE CORRECT DESCRIPTION OF WORK ON
 PERMIT APPLICATION.
  
 2) PLEASE SUBMIT ENERGY CALCULATIONS, SEE FBC
 13-101.2.2.
  
 3) SHOW ON MECHANICAL PLANS THE SIZE OF THE RETURN AIR
 TRANSFER GRILLS TO THE TWO BEDROOMS, SEE RES. M1602.4.
  
 4) BUILDING PLANS SHOW EXISTING LIVING AREA AS 919 S/F,
 COOLING LOAD CALCULATIONS SHOW THE SQUARE FEET AS 741.
 PLEASE CORRECT COOLING LOAD CALCULATION.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-12-04 Cont ID  
Sent By jleech Date 2007-12-04 Time 15:07 Rev Time 0.00
Received By jleech Date 2007-12-04 Time 14:44 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-09-17 Cont ID  
Sent By kstevens Date 2007-09-17 Time 12:37 Rev Time 0.00
Received By kstevens Date 2007-09-17 Time 12:36 Sent To  
Notes
2007-09-17 12:51:41DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. APPLICATION INDICATESREPAIR OF BACK PORCH, BUT
 PLANS INDICATE ADDITION. PLEASE CORRELATE APPLICATION,
 WHICH REQUIRES DESCRIPTION OF PROJECT IN DETAIL,AND
 PLANS. SECTION 105.1.
  
 2. SHT A1 AREA CALCULATIONS INDICATES NEW LIVING AREA
 251SF TO BE NEW BEDROOMS, BUT THE FLOOR PLAN SHOWS NEW
 FAMILY ROOM AND NEW LAUNDRY ROOM. PLEASE CORRELATE
 INFORMATION. SECTION 106.1.1.
  
 3. SHT A1 SANITARY RISER DIAGRAM. SHOW ALL PIPE SIZES.
 THE MINIMUM TRAP SIZE FOR A WASH MACHINE IS 2" PER
 TABLE 709.1, BUT RISER SHOWS 1-1/2" WASTE ARM TO THE
 TRAP. MINIMUM 2" WASTE ARM TO TRAP REQUIRED.--THE
 STACK SHALL BE A MINIMUM 3" UP TO THE SANITARY TEE PER
 SECTION 406.3. PLEASE INDICATED STACK SIZE.--THE
 WASH MACHINE REQUIRES A STANDPIPE MINIMUM 18" UPSTREAM
 OF THE TRAP. PLEASE SHOW ON RISER. SECTIONS 802.4 &
 1002.1.--A CLEANOUT IS REQUIRED ON THE STACK. THE
 CLEANOUT, IF TO THE OUTSIDE, CAN BE LOW AT THE BASE OF
 THE STACK. IF TO THE INSIDE SHALL BE SHOWN MINIMUM 4'
 ABOVE THE FLOOR FOR ACCESS. SECTIONS 708.3.4 & 708.9.
 INDICATE CLEANOUT ON RISER.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID
 SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY
 ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2007-11-14 Cont ID  
Sent By choops Date 2007-11-14 Time 11:04 Rev Time 0.00
Received By choops Date 2007-11-14 Time 11:04 Sent To E
Notes
2007-11-14 11:05:05***APPROVED - RESUB #1***
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 1 Status F Date 2007-09-10 Cont ID  
Sent By choops Date 2007-09-10 Time 10:18 Rev Time 0.00
Received By choops Date 2007-09-10 Time 10:18 Sent To E
Notes
2007-09-10 10:20:23***FAILED***
  
  
 1)PROVIDE TWO (2) COPIES OF A LEGIBLE, CURRENT
 SURVEY SHOWING ALL DIMENSIONS AND SETBACK DIMENSIONS OF
 PROPOSED ADDITION TO ALL PROPERTY LINES.
  
 2)INDICATE DIMENSIONS FROM PROPOSED ADDITION TO THE
 EXISTING GARAGE.
  
 3)SHOW PROPOSED A/C EQUIPMENT WITH SETBACK
 DIMENSIONS TO THE PROPERTY LINES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720