Plan Review Stops For Permit 07080940 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-08-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-08-18 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-08-18 |
Time |
10:02 |
Sent To |
|
|
Notes |
2008-08-18 10:03:35 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.TWO COMPLETE SETS OF PERMIT DOCUMENTS REQUIRED FOR | | PERMIT ISSUANCE. | | | | 2.SHUTTER MOUNTING TYPE IS TO CORRELATE WITH ANCHOR | | SCHEDULE; FOR EXAMPLE, A THROUGH L. | | | | 3.A .83 FACTOR IS REQUIRED FOR 3" EDGE DISTANCE, SEE | | PAGE 14 OF THE PRODUCT APPROVAL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-01-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-01-28 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-01-28 |
Time |
14:05 |
Sent To |
|
|
Notes |
2008-01-28 14:08:50 | ***PROVISO*** | | SEPARATE PERMIT FOR ROOF |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-12-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-12-27 |
Time |
18:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-12-27 |
Time |
18:20 |
Sent To |
|
|
Notes |
2007-12-27 18:27:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FACFLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | FROM PREVIOUS LIST: | | | | 1-2.)ADDRESSED. | | | | 3.)ROOFING IS NOT WITHIN THE SCOPE OF A GENERAL | | CONTRACTOR LICENSE.SEPARATE PERMIT WILL BE REQUIRED. | | (INFORMATIONAL) | | | | 4.)ADDRESSED. | | | | 5.)NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND | | OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 505.1. | | SHOW COMPLIANCE WITH EMERGENCY EGRESS REQUIREMENTS FOR | | BEDROOMS. | | | | THE CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | AS NO INFORMATION WAS PROVIDED REGARDING EXISTING | | WINDOWS, AND PROPOSED WINDOWS ARE NOT COMPLIANT FOR NEW | | CONSTRUCTION, CODE COMPLIANCE CANNOT BE DETERMINED. | | PLEASE PROVIDE REQUESTED INFORMATION REGARDING EXISTING | | WINDOWS. | | | | 6.)SEE ATTACHED INSTALLATION SCHEDULE; REQUIRED FOR | | HURRICANE SHUTTERS.PLEASE COMPLETE THE FORM AND SHOW | | PANEL LOCATIONS ON A FLOOR PLAN WHICH CORRELATES WITH | | THE INSTALLATION SCHEDULE. | | | | 7.)FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED | | FOR ALL COMPONENTS AND CLADDING (ROOF, HURRICANE | | PANELS, WINDOWS).FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | 8.)PROVIDE A DETAIL FOR THE WALL REPAIR AND STRAPPING | | IN THE LAUNDRY ROOM. | | | | PLEASE SPECIFY STRAPS. | | | | 9.)ADDRESSED. | | | | 10.)FOR THE FLAT ROOF, INDICATE WHICH APPROVED | | ASSEMBLY AND FASTENER YOU ARE USING. | | | | THIS MAY BE DONE AT THE TIME OF ROOF PERMIT APPLIATION. | | | | | | 11.) FOR THE FLAT DECK, SPECIFY THE ENHANCED FASTENING | | FOR CORNER AND PERIMETER ZONES. | | | | THIS MAY BE DONE AT THE TIME OF ROOF PERMIT | | APPLICATION. | | | | NEW COMMENTS: | | | | 12.)DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS FS471.025. | | | | 13.)GOVERNING CODE SHOULD INCLUDE 2007 AMENDMENTS, | | EFFECTIVE JULY 1, 2007. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-09-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-09-11 |
Time |
07:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-09-11 |
Time |
07:06 |
Sent To |
E |
|
Notes |
2007-09-11 07:16:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | FBC2004 | | FACFLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)SEE FBC*106.3.5.4, MINIMUM PLAN REVIEW CRITERIA | | FOR RESIDENTIAL BUIDLINGS.NO PLANS PROVIDED WITH | | APPLICATION. | | | | 2.)TWO COMPLETE COLLATED SETS REQUIRED FOR PERMIT | | ISSUANCE. | | | | 3.)ROOFING IS NOT WITHIN THE SCOPE OF A GENERAL | | CONTRACTOR LICENSE.SEPARATE PERMIT WILL BE REQUIRED. | | | | 4.)PROVIDE A FLOOR PLAN SHOWING THE LOCATION OF ALL | | WORK TO BE COVERED UNDER THIS PERMIT. | | | | 5.)PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE EXISTING | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | BEDROOMS, FBC R310, FBC EB 505.1.SHOW COMPLIANCE WITH | | EMERGENCY EGRESS REQUIREMENTS FOR BEDROOMS. | | | | 6.)SEE ATTACHED INSTALLATION SCHEDULE; REQUIRED FOR | | HURRICANE SHUTTERS.PLEASE COMPLETE THE FORM AND SHOW | | PANEL LOCATIONS ON A FLOOR PLAN WHICH CORRELATES WITH | | THE INSTALLATION SCHEDULE. | | | | 7.)FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED | | FOR ALL COMPONENTS AND CLADDING (ROOF, HURRICANE | | PANELS, WINDOWS).FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | 8.)PROVIDE A DETAIL FOR THE WALL REPAIR AND STRAPPING | | IN THE LAUNDRY ROOM. | | | | 9.)PLANS SHOULD STATE GOVERNING CODE AND WIND DESIGN | | CIRTERIA FBC1603.1.4. | | | | 10.)FOR THE FLAT ROOF, INDICATE WHICH APPROVED | | ASSEMBLY AND FASTENER YOU ARE USING. | | | | 11.) FOR THE FLAT DECK, SPECIFY THE ENHANCED FASTENING | | FOR CORNER AND PERIMETER ZONES. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-01-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-25 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-01-25 |
Time |
12:01 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2007-12-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-12-05 |
Time |
07:31 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-12-05 |
Time |
07:22 |
Sent To |
P |
|
Notes |
2007-12-05 07:31:23 | | | | | APPLICATION #07080940 | | ELECTRICAL PLAN REVIEW | | 603 CLEAR LAKE AVE | | 12/5/07 | | WEST PALM BEACH, FL. | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE | | NOTED. | | | | 1} INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE PLAN | | IS NEW OR EXISTING. IF NEW INCLUDE IN THE DESCRIPTION | | ON THE APPLICATION, PROVIDE AN AIC RATING, AND LOCATE | | ALL SERVICE EQUIPMENT ON THE PLAN, METER ENCLOSURE, | | DISCONNECTS AND PANELS, SO THAT COMPLIANCE WITH | | ARTICLES 225 AND 230 CAN BE REVIEWED. PROVIDE A RISER | | DIAGRAM WITH CONDUCTOR AND CONDUIT SIZE AND TYPE. | | | | 2} THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK | | MUST SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002 | | FAC. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-09-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-09-11 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-09-11 |
Time |
13:13 |
Sent To |
P |
|
Notes |
2007-09-11 13:16:40 | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | | | AN ELECTRICAL PERMIT IS REQUIRED PER 105.1 FBC AS | | AMENDED. | | | | TWO SETS OF ALL DOCUMENTS MUST BE SUBMITTED FOR REVIEW | | PER 106.1 FBC AS AMENDED. | | | | PLEASE INDICATE THE CODE CYCLES THIS PROJECT WAS | | DESIGNED UNDER. 2004 FBC, 2005 NEC ETC. ADD TO NOTES | | FOR CLARITY IN THE FIELD AND RECORD RETENTION PER | | 106.1.3 FBC AS AMENDED. | | | | PLEASE INCLUDE THE ADDRESS OF THE PROJECT ON THE PLANS | | FOR RECORD RETENTION.106.1.3.FBC AS AMENDED. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-08-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-21 |
Time |
08:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-21 |
Time |
08:25 |
Sent To |
B |
|
Notes |
2008-08-21 08:26:01 | TO "SHILL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-08-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-08 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-08 |
Time |
13:34 |
Sent To |
B |
|
Notes |
2008-08-08 13:35:02 | TO "SHILL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-01-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-18 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-18 |
Time |
09:07 |
Sent To |
E |
|
Notes |
2008-01-18 09:08:06 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-11-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-30 |
Time |
08:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-30 |
Time |
08:25 |
Sent To |
E |
|
Notes |
2007-11-30 08:25:50 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-09-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-09-11 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-31 |
Time |
12:33 |
Sent To |
|
|
Notes |
2007-08-31 12:33:35 | TO "MISC" BOX#1 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2007-09-14 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-09-14 |
Time |
09:14 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2007-09-14 |
Time |
09:14 |
Sent To |
|
|
Notes |
2007-09-14 09:14:54 | NO MECHANICAL PLANS SUBMITTED, AND NO | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | THIS TIME. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2008-01-25 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-25 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-25 |
Time |
16:23 |
Sent To |
B |
|
Notes |
2008-01-25 16:26:58 | ****************PROVISO*************** | | PLANS ARE INDICATING AN EXACT FIXTURE CHANGE OUT. | | ANYTHING DIFFERENT WILL REQUIRE A REVISION WITH A | | SANITARY RISER DIAGRAM FROM THE PLUMBING CONTRACTOR. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-12-07 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-12-07 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-12-07 |
Time |
14:06 |
Sent To |
B |
|
Notes |
2007-12-07 14:11:32 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 05 & 06 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS | | TO CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | PLUMBING PLAN REVIEW: | | DENIED 2ND TIME: | | | | 1. THE DESIGN PROFESSIONAL WHOSE NAME APPEARS IN THE | | TITLE BLOCK MUST SIGN, DATE AND SEAL THE DOCUMENT. PER | | *FAC 61G15-23.002. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-09-13 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-09-13 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-09-13 |
Time |
09:58 |
Sent To |
M |
|
Notes |
2007-09-13 10:21:15 | DENIED | | REFERENCE: | | ** FBC-2004 PLUMBING WITH 2006 REVISIONS. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1. MORE INFORMATION IS REQUIRED FOR THE MAIN BATHROOM | | AND KITCHEN WORK PER FBC-2004 CHAPTER 1, SECTION | | 106.1.1. | | | | A} IF PLUMBING LAYOUT IS THE SAME | | WITH NO CHANGES, PLEASE INDICATE THIS ON | | THE DRAWING. | | | | B} IF PLUMBING LAYOUT IS THE | | SAME AND THE PLUMBING FIXTURES ARE TO BE | | CHANGED, PLEASE INDCATE ON THE DRAWING. | | "EXACT FIXTURE CHANGE OUT ONLY" AND CLEARLY INDICATE | | WHAT FIXTURES ARE BEING REPLACED ON THE RESUBMITTED | | DRAWINGS. | | | | C} IF THE NEW PROPOSED PLUMBING LAYOUT IS DIFFERENT | | FROM THE EXISTING PLEASE INDICATE ON SEPERATE FLOOR | | PLAN DRAWINGS THE EXISTING FLOOR PLAN LAYOUT AND THE | | NEW PROPOSED BATHROOM AND KITCHEN LAYOUT AND FOLLOW | | WHAT IS REQUIRED IN COMMENT #2. | | | | 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 | | RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A | | PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING | | ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT | | LOCATIONS. | | | | 3. PER FBC-2004 CHAPTER 1, SECTION 106.1 SUBMITTAL | | DOCUMENTS. CONSTRUCTION | | DOCUMENTS, SPECIAL INSPECTION AND | | STRUCTURAL OBSERVATION PROGRAMS, AND | | OTHER DATA SHALL BE SUBMITTED IN TWO OR | | MORE SETS WITH EACH APPLICATION FOR A | | PERMIT. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] | | |
|
|