Plan Review Details - Permit 07080580
Plan Review Stops For Permit 07080580
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2008-03-13 Cont ID  
Sent By mjacobs Date 2008-03-13 Time 12:30 Rev Time 0.00
Received By mjacobs Date 2008-03-13 Time 11:41 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2008-03-07 Cont ID  
Sent By mjacobs Date 2008-03-07 Time 15:55 Rev Time 0.00
Received By mjacobs Date 2008-03-07 Time 13:49 Sent To PC
Notes
2008-03-07 15:54:35 
 BUILDING PLAN REVIEW
 PERMIT: 07080580
 ADD: 518-21ST STREET
 CONT: HARTNETT BUILDING GROUP LLC
 TEL: (772)429-5243
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: REVISION
 ACTION: DENIED
  
 1)THE REVISION FORM INDICATES CHANGING THE WINDOWS
 MANUFACTURE FROM PGT TO LAWSON. THE PRODUCT APPROVALS
 SUBMITTED CONTAIN NOA FOR CASEMENT WINDOWS WHICH SHOW
 FLORIDA WINDOW SYSTEMS AS THE MANUFACTURER: THERE ARE
 ALSO SOME STATE COVER SHEETS FOR EXTERIOR DOORS BUT,
 THE INSTALLATION REPORT IS MISSING. NOTE: ALL THE STATE
 COVER SHEETS SUBMITTED ARE FROM LAWSON INDUSTRIES. WHEN
 RESUBMITTING, MATCH THE STATE COVER SHEET WITH THE
 CORRECT INSTALLATION REPORT.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 FAX (561)805-6676
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-12-12 Cont ID  
Sent By mjacobs Date 2007-12-12 Time 14:28 Rev Time 0.00
Received By mjacobs Date 2007-12-12 Time 13:58 Sent To  
Notes
2007-12-12 13:58:49PROCESS PLAN

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-12-11 Cont ID  
Sent By mjacobs Date 2007-12-11 Time 17:23 Rev Time 0.00
Received By mjacobs Date 2007-12-11 Time 14:48 Sent To M
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-11-26 Cont ID  
Sent By mjacobs Date 2007-11-26 Time 08:09 Rev Time 0.00
Received By mjacobs Date 2007-11-21 Time 18:34 Sent To  
Notes
2007-11-21 18:58:33 
 BUILDING PLAN REVIEW
 PERMIT: 07080580
 ADD: 518 21ST STREET
 CONT: WPB HOUSING AUTHORITY
 TEL: (561)655-8530
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 2ND
 ACTION: DENIED
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2) 106.3.3* PRODUCT APPROVALS- 2004
 THOSE PRODUCTS THAT ARE REGULATED BY DCA RULE 9B-72
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. THE PRODUCT APPROVALS FOR THE
 ?DOORS, WINDOWS AND MULLIONS? ARE MISSING FROM THE
 PACKAGE.
  
 3) ON SHEET A-6, INDICATE WHAT MATERIAL WILL BE USED ON
 THE WALLS AROUND THE BATHTUBS WHEN THE EXISTING
 MATERIAL IS REMOVED. STATE IF DUROCK, GREEN BOARD OR
 DENSE GLASS ETC. WILL BE USED. CLARIFY PER 106.1.2
  
 4)INTERIOR WALL AND CEILING FINISH SHALL HAVE A FLAME
 SPREAD INDEX NOT GREATER THAN THAT SPECIFIED IN TABLE
 803.5. INDICATE ON THE PLANS THE FLAME SPREAD IN
 ACCORDANCE WITH FBC SECTION 803.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-09-19 Cont ID  
Sent By jjohnsto Date 2007-09-19 Time 15:24 Rev Time 3.00
Received By jjohnsto Date 2007-09-19 Time 13.22 Sent To  
Notes
2007-09-19 15:24:41CONSTRUCTION SERVICES DEPARTMENT
 200 SECOND STREET, 3RD FLOOR, WEST PALM BEACH,
 FLORIDA33401
 TEL:561-805-6713FAX:
 561-805-6731
  
 JAMES JOHNSTON PERMIT NO 07080580 BUILDING
 PLAN EXAMINERII PROJECT ALTERATION MULTIFAMILY
  
 E-MAIL:JJOHNSTON @WPB.ORG ADDRESS
 51821STSTREET
  CONTRACTOR WPB HOUSING AUTHORITY
  DATE SEPTEMBER18, 2007
  
  
 STRUCTURALPLANREVIEW
  
 1. THE QUALIFIER V.JOHNSON, (FOR THE WPB HOUSING
 AUTHORITY) LICENSE NO.7033 EXPIRED AUGUST 31, 1999.
 YOU MUST APPLY FOR A NEW LICENSE, APPROVED BY THE STATE
 OF FLORIDA BEFORE ANY FUTURE PERMITS CAN BE ISSUED. AS
 FOR THIS APPLICATION, WE ARE PROCESSING IT, AND WHEN
 APPROVED, IT WILL BE PUT ON HOLD UNTIL THIS ISSUE IS
 RESOLVED.
  
 2. FBC301.1 SCOPE.
 THE PROVISIONS OF THIS CHAPTER SHALL CONTROL THE
 CLASSIFICATION OF ALL BUILDINGS AND STRUCTURES AS TO
 USE AND OCCUPANCY.
 IDENTIFY THE USE AND OCCUPANCY RATING SEESECTION
 310.1
  
 3. SIMPSON L-90 ANGLE
 THE LEGACY REPORTNER -413 DOES NOT MATCH THE PLAN
 DESCRIPTION AS A REINFORCED ANGLE
 PLEASE FIND THE SIMPSON PRODUCT INFORMATION AND NER
 -413 REPORT ATTACHED.
 SEE PAGE 2 AND 8 OF THIS REPORT

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-09-11 Cont ID  
Sent By dpalmer Date 2007-09-11 Time 16:30 Rev Time 0.00
Received By dpalmer Date 2007-09-11 Time 16:30 Sent To  
Notes
2007-09-11 16:30:49** REDLINED**
  
 1) BEDROOM THREE: VIF IF CLOSET OR WALL SPACE INSIDE
 DOOR. IF WALL, NEEDS RECEPTACLE WITHIN 6FT OF DOOR PER
 210.52.
 THIS WAS REDLINED AS TYPICAL FOR ALL UNITS.
  
 2) THE PLANS INDICATES ONLY *WASHER* WHICH CIRCUITING
 AND PANEL SCHEDULE READS THIS AS A WASHER/DRYER COMBO.
  
 THIS WAS REDLINED AS TYPICAL FOR ALL UNITS.
  
 PLANS OK, STAMPED ELECTRICAL SHEETS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2007-10-11 Cont ID  
Sent By mwennerg Date 2007-10-11 Time 13:49 Rev Time 0.00
Received By mwennerg Date 2007-10-11 Time 13:49 Sent To  
Notes
2007-10-11 13:53:09***APPROVED***
  
 1) INDIVIDUAL UNITS MAY HAVE CHARACTERS THAT ARE A
 MINIMUM OF 3" IN HEIGHT AND CONTRASTING TO THE
 BACKGROUND. THE MAIN BUILDING ADDRESS IS REQUIRED TO BE
 MINIMUM 6" IN HEIGHT WITH THE SAME CONTRASTING
 CHARACTERISTICS.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-03-11 Cont ID  
Sent By adarroug Date 2008-03-11 Time 15:24 Rev Time 0.00
Received By adarroug Date 2008-03-11 Time 15:24 Sent To B
Notes
2008-03-11 15:25:25TO "MJACOBS" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-03-04 Cont ID  
Sent By adarroug Date 2008-03-04 Time 09:57 Rev Time 0.00
Received By adarroug Date 2008-03-04 Time 09:57 Sent To B
Notes
2008-03-04 09:58:10TO "MJACOBS" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-12-10 Cont ID  
Sent By adarroug Date 2007-12-10 Time 13:29 Rev Time 0.00
Received By adarroug Date 2007-12-10 Time 13:29 Sent To  
Notes
2007-12-10 13:32:42TO "COMM" BD#35

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-11-19 Cont ID  
Sent By adarroug Date 2007-11-19 Time 13:29 Rev Time 0.00
Received By adarroug Date 2007-11-19 Time 13:29 Sent To  
Notes
2007-11-19 15:31:34TO "COMM" BD#41--EXPEDITED PERMIT--
2007-11-19 13:31:17WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-10-12 Cont ID  
Sent By kstevens Date 2007-10-12 Time 13:11 Rev Time 0.00
Received By kstevens Date 2007-08-22 Time 11:29 Sent To  
Notes
2007-09-11 09:03:15TO "COMM" BD#31
2007-08-22 11:33:33WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2007-12-12 Cont ID  
Sent By rregueir Date 2007-12-12 Time 08:35 Rev Time 0.00
Received By rregueir Date 2007-12-12 Time 08:34 Sent To B
Notes
2007-12-12 08:35:01NO MECHANICAL SHOWN IN SCOPE OF WORK.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2007-10-04 Cont ID  
Sent By hmoser Date 2007-10-04 Time 18:17 Rev Time 0.00
Received By hmoser Date 2007-10-04 Time 18:17 Sent To  
Notes
2007-10-04 18:18:03NO MECHANICAL PLANS .HM.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-12-13 Cont ID  
Sent By kstevens Date 2007-12-12 Time 08:47 Rev Time 0.00
Received By kstevens Date 2007-12-12 Time 08:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-11-30 Cont ID  
Sent By kstevens Date 2007-11-30 Time 07:09 Rev Time 0.00
Received By kstevens Date 2007-11-30 Time 07:09 Sent To  
Notes
2007-11-30 07:18:31DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 ****FROM PREVIOUS REVIEW:
  
 1. OK
  
 2. SHT P-2POTABLE RISER. WATER HAMMER ARRESTORS ARE
 REQUIRED ON BOTH THE HOT & COLD WATER SUPPLY TO THE
 WASH MACHINES. SECTION 604.9. ONLY ONE IS SHOWN AT EACH
 W/M.
 ****RESPONSE NOTED, BUT THE WATER HAMMER ARRESTOR IS
 ONLY SHOWN ON THE HOT SUPPLY ONLY. PLEASE SHOW THE
 WATER HAMMER ARRESTORS ON BOTH THE HOT AND COLD WATER
 SUPPLIES TO THE WASH MACHINE.
  
 3. SHT P-2 SANITARY RISER. ONLY THE FIXTURES WITHIN THE
 BATHROOM GROUPS SHALL CONNECT TO THE WET-VENTED
 HORIZONTAL BRANCH DRAIN. THE KITCHEN SINK SHALL
 DISCHARGE DOWNSTREAM OF THE WET VENT. SECTION 909.1.
 PLEASE SHOW THE KITCHEN SINK CONNECTION DOWNSTREAM OF
 THE BATHROOM FIXTURES.
 ****RESPONSE NOTED, BUT THE TUB IS NOT VENTED AS SHOWN.
 THE VENT DOWNSTREAM OF THE OF THE TUB DOES NOT VENT THE
 TUB. IF THE TUB IS CONNECTED TO THE BRANCH LINE
 UPSTREAM OF THE KITCHEN SINK THE PLANS WILL MEET THE
 CODE REQUIREMENT OR A SEPARATE VENT AT THE TUB WILL BE
 REQUIRED.
  
 4. OK
 5. OK
  
 6. THE SEAL FOR THE PROFESSIONAL ENGINEER SHALL INCLUDE
 THE WORD "LICENSE" IN THE SEAL. PLANS SEALED BY JOHN
 SYLVIA DO NOT INDICATE "LICENSE" ON THE SEAL. FAC
 61G15-23.001 & FS 471.025. PLEASE RESEAL THE SHEETS AND
 MAKE SURE ALL INFORMATION REQUIRED ON THE SEAL IS
 IMPRESSED ON EACH SHEET.
 ****RESPONSE NOTED, BUT SHEETS P-1 & P-3 HAVE NOT BEEN
 RESEALED AND DO NOT HAVE THE WORD "LICENSE" IMPRESSED
 ON THE SHEETS AS REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-10-12 Cont ID  
Sent By kstevens Date 2007-10-12 Time 10:27 Rev Time 0.00
Received By kstevens Date 2007-10-12 Time 10:27 Sent To  
Notes
2007-10-12 11:02:22DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. SHTS D-1 & D-2 PLEASE INDICATE THE LOCATION OF THE
 EXISTING WATER HEATERS FOR EACH UNIT. SECTION 106.1.2.
  
 2. SHT P-2POTABLE RISER. WATER HAMMER ARRESTORS ARE
 REQUIRED ON BOTH THE HOT & COLD WATER SUPPLY TO THE
 WASH MACHINES. SECTION 604.9. ONLY ONE IS SHOWN AT EACH
 W/M.
  
 3. SHT P-2 SANITARY RISER. ONLY THE FIXTURES WITHIN THE
 BATHROOM GROUPS SHALL CONNECT TO THE WET-VENTED
 HORIZONTAL BRANCH DRAIN. THE KITCHEN SINK SHALL
 DISCHARGE DOWNSTREAM OF THE WET VENT. SECTION 909.1.
 PLEASE SHOW THE KITCHEN SINK CONNECTION DOWNSTREAM OF
 THE BATHROOM FIXTURES.
  
 4. SHT P-2 SANITARY RISER. A STANDPIPE IS REQUIRED FOR
 EACH WASH MACHINE PER SECTIONS 802.4 & 1002.1. PLEASE
 INDICATE THE STANDPIPE ON RISER.--A CLEANOUT IS
 REQUIRED AT THE BASE OF THE W/M STACK A MINIMUM OF 4 FT
 ABOVE THE FLOOR FOR ACCESS. SECTION 708.9. PLEASE
 INDICATE CLEANOUTS ON RISER DIAGRAM.
  
 5. SHT P-2 SANITARY RISER. THE AIR ADMITTANCE VALVES
 SHALL BE LOCATED A MINIMUM OF 4 IN. ABOVE THE FIXTURE
 DRAIN BEING VENTED. ON THE WASH MACHINES THEY SHALL BE
 LOCATED 4" ABOVE THE AIR GAP OF THE FITTING OR 4" ABOVE
 THE STANDPIPE. SECTION 917.4. PLEASE SHOW THE AAV'S
 ABOVE THE TOP OF THE STANDPIPE MIN. 4".
  
 6. THE SEAL FOR THE PROFESSIONAL ENGINEER SHALL INCLUDE
 THE WORD "LICENSE" IN THE SEAL. PLANS SEALED BY JOHN
 SYLVIA DO NOT INDICATE "LICENSE" ON THE SEAL. FAC
 61G15-23.001 & FS 471.025. PLEASE RESEAL THE SHEETS AND
 MAKE SURE ALL INFORMATION REQUIRED ON THE SEAL IS
 IMPRESSED ON EACH SHEET.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2007-09-20 Cont ID  
Sent By choops Date 2007-09-20 Time 14:25 Rev Time 0.00
Received By choops Date 2007-09-20 Time 14:25 Sent To  
Notes
***NONE***