Plan Review Details - Permit 07080517
Plan Review Stops For Permit 07080517
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-11-30 Cont ID  
Sent By rmcdouga Date 2007-11-30 Time 09:39 Rev Time 0.00
Received By rmcdouga Date 2007-11-30 Time 06:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-11-09 Cont ID  
Sent By rmcdouga Date 2007-11-09 Time 15:56 Rev Time 0.00
Received By rmcdouga Date 2007-11-09 Time 15:56 Sent To  
Notes
2007-11-09 16:50:172004 FBC W/2007 REVISIONS
 CONSTRUCT A NEW SINGLE FAMILY RESIDENCE
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE DESIGN PRESSURES LISTED IN THE PRODUCT APPROVALS
 FOR THE 9' AND 16' GARAGE DOORS ARE LESS THAN THE
 REQUIRED COMPONENT AND CLADDING PRESSURES SPECIFIED ON
 SHEET A4.0 OF THE PLANS. PLEASE CORRECT. FAC RULE 9B-72
 AND FBC R301.2.1 SEE COMMENT # 12 OF PREVIOUS BUILDING
 REVIEW.
  
 4) HAVE THE PRIVATE PROVIDER REVIEW AND PLACE THEIR
 STAMP ON THE PRODUCT APPROVALS THAT ARE REQUIRED BY FAC
 RULE 9B-72.. SEE FS 553.791(6).
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-30 Cont ID  
Sent By rmcdouga Date 2007-08-30 Time 10:10 Rev Time 0.00
Received By rmcdouga Date 2007-08-30 Time 07:26 Sent To  
Notes
2007-08-30 17:21:282004 FBC WITH 2007 SUPPLEMENT
 CONSTRUCT NEW SINGLE FAMILY RESIDENCE
  
 DENIED BY BUILDING
  
 1)A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2)SUBMIT A COPY OF THE PAID RECEIPT FOR THE PALM
 BEACH COUNTY IMPACT FEES.
  
 3) REVISE THE CODE EDITION SPECIFIED ON SHEET T1 TO THE
 2004 FBC WITH 2007 SUPPLEMENT.
  
 4) THE REAR QUADRANT OF THE STRUCTURE ABUTS A LAKE AND
 A GOLF COURSE, WHICH HAS EXPOSURE C-TYPE TERRAIN FOR A
 DISTANCE OF MORE THAN 600 FEET. THEREFORE,THE
 STRUCTURE IS LOCATED IN EXPOSURE CATEGORY C. PER
 R301.2.1.4 EXPOSURE CATEGORY. 3. EXPOSURE C. OPEN
 TERRAIN WITH SCATTERED OBSTRUCTIONS, INCLUDING SURFACE
 UNDULATIONS OR OTHER IRREGULARITIES, HAVING HEIGHTS
 GENERALLY LESS THAN 30 FEET (9144 MM) EXTENDING MORE
 THAN 1,500 FEET (457.2 M) FROM THE BUILDING SITE IN ANY
 QUADRANT. THIS EXPOSURE SHALL ALSO APPLY TO ANY
 BUILDING LOCATED WITHIN EXPOSURE B-TYPE TERRAIN WHERE
 THE BUILDING IS DIRECTLY ADJACENT TO OPEN AREAS OF
 EXPOSURE C-TYPE TERRAIN IN ANY QUADRANT FOR A DISTANCE
 OF MORE THAN 600 FEET (182.9 M). SHORT-TERM (LESS THAN
 TWO YEAR) CHANGES IN THE PRE-EXISTING TERRAIN EXPOSURE,
 FOR THE PURPOSES OF DEVELOPMENT, SHALL NOT BE
 CONSIDERED OPEN FIELDS. WHERE DEVELOPMENT BUILD OUT
 WILL OCCUR WITHIN THREE YEARS AND THE RESULTANT
 CONDITION WILL MEET THE DEFINITION OF EXPOSURE B,
 EXPOSURE B SHALL BE REGULATING FOR THE PURPOSE OF
 PERMITTING. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY,
 GRASSLANDS AND OCEAN OR GULF SHORELINES. THIS CATEGORY
 DOES NOT INCLUDE INLAND BODIES OF WATER THAT PRESENT A
 FETCH OF 1 MILE (1.61 KM) OR MORE OR INLAND WATERWAYS
 OR RIVERS WITH A WIDTH OF 1 MILE (1.61 KM) OR MORE (SEE
 EXPOSURE D). PLEASE REVISE THE EXPOSURE CATEGORY
 SPECIFIED ON THE PLANS AND REVISE THE COMPONENT AND
 CLADDING PRESSURES TO EXPOSURE C.
  
 5) PLEASE INDICATE THAT THE INTERNAL PRESSURE
 COEFFICIENT ON T1 IS FOR BOTH POSITIVE AND NEGATIVE
 PRESSURES BY ADDING THE PLUS AND MINUS SIGNS. SEE
 ASCE7-02.
  
 6)SUBMIT A DRAINAGE PLAN SHOWING COMPLIANCE WITH
 R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
 TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE
 GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM
 OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048
 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
  
 7) TWO OF THE STEEL COLUMNS ON SHEET A1.0 DO NOT HAVE
 THE BASE CONNECTIONS SPECIFIED ON THE FOUNDATION PLAN.
  
 8) SPECIFY THE LENGTH/EMBED DEPTH OF THE 5/8" EXPANSION
 BOLTS IN THE CONNECTION DETAIL G ON A3.0.
  
 9) SPECIFY THE WINDLOAD PRESSURES FOR THE EXTERIOR DOOR
 AT THE MASTER BEDROOM.
  
 10) PLEASE CLARIFY IF THE STEEL COLUMN TO TIE BEAM
 CONNECTION DETAIL ON A7 IS FOR THE THE 6 X 2 INCH
 COLUMNS BETWEEN THE LIVING ROOM WINDOWS. THE DETAIL
 SHOWS A 4 X 4 INCH STEEL COLUMN.
  
 11) THE FL PRODUCT APPROVAL NUMBER LISTED IN THE ANCHOR
 SCHEDULE ON A3 FOR THE USP RT16 HURRICANE TIE IS
 INCORRECT. THE FL NUMBER FOR THIS CONNECTOR IS FL565,
 THE ONE LISTED IS FOR THE RT16 FLAT AND TWIST STRAP
 CONNECTORS. PLEASE CORRECT.
  
 12) THE DOUBLE OUT SWING FRONT DOORS, AS WELL AS, SOME
 OF THE OTHER PRODUCTS MAY NOT MEET THE INCREASED
 COMPONENT AND CLADDING PRESSURES OF THE EXPOSURE C
 CATEGORY. PLEASE REVIEW PRODUCT APPROVALS FOR ADEQUATE
 PRESSURES.
  
 13) SUBMIT RATIONAL ANALYSIS FROM A FLORIDA LICENSED
 ENGINEER FOR THE EXTERIOR 18" X 18" ACCESS DOOR TO THE
 WHIRLPOOL TUB MOTOR SHOWING THAT THE DOOR IS CAPABLE OF
 WITH STANDING THE WINDLOAD PRESSURES. SPECIFY THE
 ANCHOR TYPE, EMBED DEPTH, ETC. PROVIDE MANUFACTURER'S
 SPECIFICATIONS.
  
 14) SUBMIT PRODUCT APPROVALS FOR THE LARGE MISSLE
 IMPACT STRUCTURAL WINDOW MULLIONS. THE ONLY ONES
 SUBMITTED ARE BAY WINDOW MULLIONS.
  
 15) THE 54 X 96 INCH @ THE DINING ROOM AND 60 X 86 INCH
 @ THE MASTER BATH ARCH TOP FIXED GLASS WINDOWS AND THE
 92 X 98 INCH FIXED GLASS WINDOW @ THE MASTER BED ROOM
 EXCEED THE SIZE LIMITATIONS OF THE PRODUCT APPROVAL FOR
 THE PGT PW-701 WINDOWS. PLEASE CORRECT.
  
 16) SUBMIT A SIGNED AND SEALED ANALYSIS REPORT OF TIE
 BEAM CB-4 ABOVE THE BAY WINDOW AND THE ECCENTRICALLY
 LOADED COLUMNS FROM A FLORIDA LICENSED ENGINEER. THE
 ALUMINUM CORNER POSTS FOR THE BAY WINDOWS SHOWN ON A2.O
 DO NOT PROVIDE ANY SUPPORT FOR THE GRAVITY LOADS OF THE
 BEAM. PROVIDE A STEEL PLACEMENT DETAIL FOR THE BEAM AND
 SUPPORTING COLUMN REINFORCEMENT. FBC * 106.1.2
  
 -ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-05-07 Cont ID  
Sent By btrobaug Date 2008-05-07 Time 07:06 Rev Time 0.00
Received By btrobaug Date 2008-05-07 Time 06:55 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-11-08 Cont ID  
Sent By btrobaug Date 2007-11-08 Time 08:26 Rev Time 0.00
Received By btrobaug Date 2007-11-08 Time 07:53 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-08-21 Cont ID  
Sent By tgordon Date 2007-08-21 Time 16:07 Rev Time 0.00
Received By btrobaug Date 2007-08-21 Time 07:09 Sent To P
Notes
2007-08-21 12:41:55 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 FLORIDA STATUTES 1/2007,2004 FBC AS AMENDED, CHAPTER
 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 THESE COMMENTS REFER TO SHEET A8.0.
  
 1} THERE IS NO EQUIPMENT GROUND SHOWN BEING RAN WITH
 THE FEEDER FROM PANEL "B" TO THE POOL PANEL.AN
 EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED FROM
 THE FIRST MEANS OF DISCONNECT TO THE PANEL PER 250.110,
 SIZED PER 250.122. SEE RISER DIAGRAM.
  
 2} THERE IS A 20 AMP CIRCUIT,#22, IN PANEL "A" FOR
 THE POOL LIGHTS, AND A 15 AMP CIRCUIT, NO NUMBER GIVEN,
 FOR POOL LIGHTS IN SUB PANEL"D". IT IS NOT CLEAR IF
 THIS IS A DUPLICATION OR IF THERE ARE TWO SEPARATE
 CIRCUITS FOR POOL LIGHTS. SEE ARTICLE 408.4 2005 NEC
 WHICH ASKS FOR CLARITY IN THE SCHEDULES.
  
 3} CIRCUIT # 21, PANEL "A", DINING ROOM OUTLETS, ARE ON
 A 15 AMP CIRCUIT. TO COMPLY WITH 210.52(B)(1) FOR SMALL
 APPLIANCE CIRCUITS, THIS MUST BE A 20 AMP CIRCUIT.
  
 4} CIRCUIT # 40 IN BOTH PANELS INDICATES A LOAD OF 2.3
 KW. IN VIOLATION OF 210.23, LIMITING THE CIRCUIT
 AMPACITY TO 80% OF THE CIRCUIT RATING ( AT 20 AMPS).
 LIST THE CIRCUIT RATING AND CONDUCTOR SIZE SO
 COMPLIANCE WITH 310.16 MAY BE REVIEWED. NOTE: THE HIGH
 HATS LISTED ON THOSE CIRCUITS ARE NOT REQUIRED TO BE ON
 A SEPARATE CIRCUIT AND MAY BE PUT ON OTHER LIGHTING AND
 RECEPTACLE CIRCUITS.
  
 5} LOCATE PANEL "D" ON THE PLAN. 106.3.5.4(8), FBC AS
 AMENDED.
  
 6} SHEET A2.0 INDICATES IN A NOTE THATAHU #3,IN
 "HER" CLOSET, MASTER BEDROOM, IS CEILING HUNG. SHEET M1
 SYSTEM SPECIFICATIONS INDICATE THERE IS A 30 AMP FUSE
 IN THE AIR HANDLER. OVERCURRENT PROTECTION IN A CLOTHES
 CLOSET IS IN VIOLATION OF 240.24(D). ALSO THERE IS A
 DISCONNECT IN THE CLOSET AND IT IS UNCLEAR IF IT
 CONTAINS OCP. IF THE INSTALLATION IS INTENDED TO BE IN
 THE ATTIC THAN IN THE CLOSET, RECEPTACLE PER 210.63, IS
 REQUIRED.
  
 7} THE ENGINEERSNAME ON THE PLAN PROVIDER AFFIDAVIT
 AND SEAL, IS DIFFERENT THAN THE ONE ON FILE WITH DBPR.
 PLEASE CLARIFY.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-10-03 Cont ID  
Sent By adarroug Date 2008-10-03 Time 16:07 Rev Time 0.00
Received By adarroug Date 2008-10-03 Time 16:07 Sent To Z
Notes
2008-10-03 16:07:56TO"Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-08-26 Cont ID  
Sent By tgordon Date 2008-08-26 Time 08:57 Rev Time 0.00
Received By tgordon Date 2008-08-26 Time 08:57 Sent To Z
Notes
2008-08-26 08:57:44TO "ZONING" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-05-05 Cont ID  
Sent By adarroug Date 2008-05-05 Time 09:06 Rev Time 0.00
Received By adarroug Date 2008-05-05 Time 09:06 Sent To E
Notes
2008-05-05 09:07:47TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-04-24 Cont ID  
Sent By adarroug Date 2008-04-24 Time 15:31 Rev Time 0.00
Received By adarroug Date 2008-04-24 Time 15:31 Sent To M
Notes
2008-04-24 15:32:20TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-11-19 Cont ID  
Sent By adarroug Date 2007-11-19 Time 10:16 Rev Time 0.00
Received By adarroug Date 2007-11-19 Time 10:16 Sent To P
Notes
2007-11-19 10:17:09TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-11-02 Cont ID  
Sent By adarroug Date 2007-11-02 Time 11:02 Rev Time 0.00
Received By adarroug Date 2007-11-02 Time 11:02 Sent To Z
Notes
2007-11-02 11:02:46TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-30 Cont ID  
Sent By rmcdouga Date 2007-08-30 Time 10:10 Rev Time 0.00
Received By rmcdouga Date 2007-08-16 Time 15:57 Sent To  
Notes
2007-08-16 15:57:10TO "SFR" "Z"

Review Stop L LANDSCAPING
Rev No 2 Status P Date 2008-10-06 Cont ID  
Sent By rkussner Date 2008-10-06 Time 12:19 Rev Time 0.00
Received By rkussner Date 2008-10-06 Time 12:19 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2008-08-27 Cont ID  
Sent By rkussner Date 2008-08-27 Time 10:02 Rev Time 0.00
Received By rkussner Date 2008-08-27 Time 10:02 Sent To  
Notes
2008-08-27 10:04:52LANDSCAPE ***FAILED***
  
 PROVIDE SIZE AND SPACING FOR ALL PROPOSED PLANT
 MATERIAL.
  
 CONTACT INFORMATION:
 ROBERT KUSSNER @ 822-1462

Review Stop M MECHANICAL (A/C)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2008-04-25 08:23:02REVISED MECH. PLAN.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-11-09 Cont ID  
Sent By tgordon Date 2007-11-08 Time 11:29 Rev Time 0.30
Received By tgordon Date 2007-11-08 Time 11:28 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-08-20 Cont ID  
Sent By tgordon Date 2007-08-20 Time 14:06 Rev Time 0.30
Received By tgordon Date 2007-08-20 Time 14:06 Sent To E
Notes
2007-08-20 15:22:33PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER
 1 CITY OF WEST PALM BEACH AMENDMENTS.
  
 *** DENIED ***
 1) SEE F.S. 553.719 (4) (C) (C) FOR PRIVATE PROVIDER
 ACKNOWLEDMENT MISSING.AN ACKNOWLEDGMENT FROM THE FEE
 OWNER IN SUBSTANTIALLY THE FOLLOWING FORM:
 I HAVE ELECTED TO USE ONE OR MORE PRIVATE
 PROVIDERS TO PROVIDE BUILDING CODE PLANS REVIEW AND/OR
 INSPECTION SERVICES ON THE BUILDING OR STRUCTURE THAT
 IS THE SUBJECT OF THE ENCLOSED PERMIT APPLICATION, AS
 AUTHORIZED BY S. 553.791, FLORIDA STATUTES. I
 UNDERSTAND THAT THE LOCAL BUILDING OFFICIAL MAY NOT
 REVIEW THE PLANS SUBMITTED OR PERFORM THE REQUIRED
 BUILDING INSPECTIONS TO DETERMINE COMPLIANCE WITH THE
 APPLICABLE CODES, EXCEPT TO THE EXTENT SPECIFIED IN
 SAID LAW. INSTEAD, PLANS REVIEW AND/OR REQUIRED
 BUILDING INSPECTIONS WILL BE PERFORMED BY LICENSED OR
 CERTIFIED PERSONNEL IDENTIFIED IN THE APPLICATION. THE
 LAW REQUIRES MINIMUM INSURANCE REQUIREMENTS FOR SUCH
 PERSONNEL, BUT I UNDERSTAND THAT I MAY REQUIRE MORE
 INSURANCE TO PROTECT MY INTERESTS. BY EXECUTING THIS
 FORM, I ACKNOWLEDGE THAT I HAVE MADE INQUIRY REGARDING
 THE COMPETENCE OF THE LICENSED OR CERTIFIED PERSONNEL
 AND THE LEVEL OF THEIR INSURANCE AND AM SATISFIED THAT
 MY INTERESTS ARE ADEQUATELY PROTECTED. I AGREE TO
 INDEMNIFY, DEFEND, AND HOLD HARMLESS THE LOCAL
 GOVERNMENT, THE LOCAL BUILDING OFFICIAL, AND THEIR
 BUILDING CODE ENFORCEMENT PERSONNEL FROM ANY AND ALL
 CLAIMS ARISING FROM MY USE OF THESE LICENSED OR
 CERTIFIED PERSONNEL TO PERFORM BUILDING CODE INSPECTION
 SERVICES WITH RESPECT TO THE BUILDING OR STRUCTURE THAT
 IS THE SUBJECT OF THE ENCLOSED PERMIT APPLICATION.
  
 2) ENGINEERS NAME ON PRIVATE PROVIDER AFFIDAVIT JOHN F.
 DESNOYERS, IS NOT THE SAME NAME ON LICENSE # 47885
 (JEAN F. DESNOYERS) PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL: [email protected].

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-11-26 Cont ID  
Sent By mperson Date 2007-11-26 Time 15:43 Rev Time 0.00
Received By mperson Date 2007-11-26 Time 15:43 Sent To B
Notes
2007-11-26 15:47:04CONTRACTOR INFORMATION
 (SHEET A2 IS INDICATING GAS APPLIANCES)
 NOTE: GAS PERMIT REQUIRED. GAS OR PLUMBING CONTRACTOR
 TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL GAS
 INSPECTIONS TO BE COMPLETE BEFORE FINAL INSPECTION.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-11-09 Cont ID  
Sent By tgordon Date 2007-11-09 Time 14:57 Rev Time 0.00
Received By mperson Date 2007-11-09 Time 08:46 Sent To B
Notes
2007-11-09 09:33:13PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 05 & 06 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS
 TO CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 PLUMBING PLAN REVIEW:
 DENIED 2ND TIME:
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE ON THE
 RESUBMITTED PLANS.
  
 1. SHEET A6.0 PLUMBING RISER DIAGRAM: THE BIDET IN THE
 MASTER BATH IS NOT VENTED. PER *901.2.1, VENTING
 REQUIRED.
  
 2. ENERGY CALCULATIONS WERE NOT RESUBMITTED WITH PLANS
 PLEASE RESUBMIT ENERGY CALULATIONS WITH WATER HEATING
 REQUIREMENTS PER
 CHAPTER 13 ENERGY EFFICIENCY SECTION 13-101.0 GENERAL.
 THIS CODE IS A STATEWIDE UNIFORM CODE AND SHALL NOT BE
 MADE MORE STRINGENT OR LENIENT BY LOCAL GOVERNMENT. THE
 CODE PROVIDES FOR A UNIFORM STANDARD OF ENERGY
 EFFICIENCY BY, AT A MINIMUM, SETTING FORTH MINIMUM
 REQUIREMENTS FOR EXTERIOR ENVELOPES, LIGHTING,
 ELECTRICAL DISTRIBUTION, AND SELECTION OF HEATING,
 LIGHTING, VENTILATION, AIR CONDITIONING AND SERVICE
 WATER HEATING SYSTEMS. IT SHALL APPLY TO ALL NEW
 BUILDINGS, TO ADDITIONS TO EXISTING BUILDINGS AND
 MANUFACTURED HOMES, TO RENOVATIONS TO EXISTING
 BUILDINGS, BOTH PUBLIC AND PRIVATE, WITH CERTAIN
 EXCEPTIONS, TO CHANGES OF OCCUPANCY TYPE, TO THE
 SITE-INSTALLED COMPONENTS AND FEATURES OF A
 MANUFACTURED HOMES AT THEIR FIRST SET-UP, AND TO THE
 INSTALLATION OR REPLACEMENT OF BUILDING SYSTEMS AND
 COMPONENTS WITH NEW PRODUCTS FOR WHICH THERMAL
 EFFICIENCY STANDARDS ARE SET BY THIS CODE. NEW
 BUILDINGS, WITH EXCEPTION OF THOSE EXEMPTED BELOW, AND
 IN ACCORDANCE WITH THE SPECIFIC EXCEPTIONS OF
 INDIVIDUAL SECTIONS SHALL BE DESIGNED TO COMPLY WITH
 SUBCHAPTER 13-4 OR 13-6 OF THIS CODE.
  
 **THE FOLLOWING IS CONTRACTOR INFORMATION ONLY BECAUSE
 SHEET A2.0 IS INDICATING GAS APPLIANCES.
  
 NOTE: GAS PERMIT REQUIRED. PLUMBING OR GAS CONTRACTOR
 TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL GAS
 INSPECTIONS TO BE COMPLETE BEFORE FINAL INSPECTION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-08-23 Cont ID  
Sent By mperson Date 2007-08-23 Time 08:17 Rev Time 0.00
Received By mperson Date 2007-08-23 Time 08:17 Sent To B
Notes
2007-08-23 09:38:41DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4
 RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A
 PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING
 ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT
 LOCATIONS.
 NOTE: NOT ALL WASTE PIPES OR TRAPS ARE SIZED ON SHEET
 A6.0 PLUMBING RISER DIAGRAM. PLEASE CORRECT THIS ON THE
 RESUBMITTAL.
  
 2. SHEET A6.0 SANITARY PLUMBING RISER DIAGRAM DOES NOT
 REFLECT THE FLOOR PLAN ON SHEET A2.0. PER FBC-2004
 CHAPTER 1 THE CITY OF WEST PALM BEACH AMENDMENTS
 SECTION 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE
 AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE BUILDING OFFICIAL.
  
 A} THE WASHING MACHINE AND LAUNDRY TRAY ARE BEING
 INDICATED IN THE WRONG PLACE.
  
 B} BATHROOM OFF BEDROOM 2 THE TUB/SHOWER IS
 INCORRECTLY IDENIFIED AS A SHOWER AND LOCATED IN THE
 WRONG PLACE. ALSO THE LAV IS LOCATED IN THE WRONG
 PLACE.
  
 3. SHEET A6.0 SANITARY PLUMBING RISER DIAGRAM THE
 WASHING MACHINE NEEDS A TRAP PER FBC-2004 PLUMBING,
 SECTION 1002.1 ALSO PLEASE INDICATE THE REQUIRED
 STANDPIPE FOR THE WASHING MACHINE PER FBC-2004
 PLUMBING, SECTION 802.4.
  
 4. SHEET A6.0 SANITARY PLUMBING RISER DIAGRAM MASTER
 BATH W. POOL TUB PER FBC-2004 PLUMBING, TABLE 906.1 A
 VENT IS REQUIRED FOR THE W. POOL TUB TRAP BECAUSE IT IS
 OVER 6 FEET FROM THE VENT.
  
 5. SHEET A6.0 SANITARY PLUMBING RISER DIAGRAM
 DISHWASHER DRAIN. PER FBC-2004 PLUMBING SECTION 802.1.6
 DOMESTIC DISHWASHING MACHINES SHALL DISCHARGE
 INDIRECTLY THROUGH AN AIR GAP OR AIR BREAK INTO A
 STANDPIPE OR WASTE RECEPTOR IN ACCORDANCE WITH SECTION
 802.2 OR DISCHARGE INTO A WYE-BRANCH FITTING ON THE
 TAILPIECE OF THE KITCHEN SINK OR THE DISHWASHER
 CONNECTION OF A FOOD WASTE GRINDER. PLEASE CLARIFY HOW
 THE DISHWASHER WILL DRAIN. IF IT IS THE INTENT TO USE A
 STANDPIPE PLEASE CLEARLY INDICATE AND SIZE THE
 STANDPIPE ON THE RESUBMITTAL.
  
 6. SHEET A6.0 SANITARY PLUMBING RISER DIAGRAM POWDER
 ROOM: THE 2 INCH LOOP VENT BEING INDICATED FROM THE TOP
 OF THE WATER CLOSET IS NOT FEASIBLE OR REQUIRED. PLEASE
 DELETE THIS VENT ON THE RESUBMITTAL.
  
 **THE FOLLOWING IS CONTRACTOR INFORMATION ONLY BECAUSE
 SHEET A2.0 IS INDICATING GAS APPLIANCES
  
 NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL INSPECTION.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2007-11-07 Cont ID  
Sent By choops Date 2007-11-07 Time 14:16 Rev Time 0.00
Received By choops Date 2007-11-07 Time 14:16 Sent To E
Notes
2007-11-07 14:17:40***APPROVED - RESUB #1***
  
 FRONT SETBACK OK PER PB CASE NO. 993SSS
  
 TYPICAL LANDSCAPE PLANTING TYPE AND QUANTITY PROVIDED.
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 1 Status F Date 2007-08-20 Cont ID  
Sent By choops Date 2007-08-20 Time 09:17 Rev Time 0.00
Received By choops Date 2007-08-20 Time 09:17 Sent To E
Notes
2007-08-20 09:25:35***FAILED***
  
  
 1)DOES NOT MEET FRONT SETBACK REQUIREMENT OF 25'.
  
 2)PROVIDE SETBACK DIMENSIONS FROM A/C EQUIPMENT TO
 THE PROPERTY LINES.
  
 3)SOME DIMENSIONS ON SHEET A4.0 ARE NOT LEGIBLE.
 ELEVATION DIMENSIONS TO BE MEASURED FROM GRADE.
  
 4)PLEASE PROVIDE A LANDSCAPE PLAN SHOWING COMPLIANCE
 WITH SECTION 94-442 OF THE CITY OF WEST PALM BEACH
 ZONING AND LAND DEVELOPMENT REGULATIONS.
  
 5)PROVIDE TOTAL SQUARE FOOTAGE OF PROPOSED DRIVEWAY
 WITHIN THE FRONT YARD (FROM FRONT PROPERTY LINE TO THE
 FRONT OF THE PRINCIPAL STRUCTURE).
  
 NOTE:MUST MAINTAIN THE LESSOR OF 1,000 SQ.FT. OR 75%
 OF THE FRONT YARD AS LANDSCAPED MATERIAL.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720
  