Plan Review Stops For Permit 07080515 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-04-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-04-18 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-04-18 |
Time |
07:00 |
Sent To |
|
|
Notes |
2008-04-18 07:58:58 | REVISED STRUCTURAL DETAIL FOR THE LIVING ROOM WINDOWS. | | CHANGED FROM TUBE STEEL COLUMNS BETWEEN WINDOWS TO | | REINFORCED MASONRY COLUMNS. SEE SHEET A2. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-04-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-04-09 |
Time |
07:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-04-08 |
Time |
19:15 |
Sent To |
|
|
Notes |
2008-04-09 07:23:29 | REVISED DRAWING SHEET #1 MASONRY REPAIR IS DENIED | | | | 1) THE ENGINEER'S SIGNATURE ON THE DRAWING IS A COPY. | | THE SIGNATURE IS REQUIRED TO BE ORIGINAL PER FS 471 AND | | FAC 61G15-23.002. | | | | 2) THE DRAWING REVISING THE PLAN IS FROM STEVE WALSH AN | | ENGINEER AND THE APPROVED PLANS ARE SIGNED AND SEALED | | BY RANDALL STOFFT AN ARCHITECT. THE DESIGNER OF RECORD | | FOR THE PROJECT IS RANDALL STOFFT ANY REVISIONS TO THE | | PLANS ARE REQUIRED TO BE DONE BY HIM. THERE IS NOTHING | | ON THE PLANS THAT INDICATE STEVE WALSH AS THE | | STRUCTURAL DESIGNER FOR THIS PROJECT. | | | | 3) ONE OF THE SUBMITTED DRAWINGS IS BEING RETAINED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-03-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-03-04 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-03-04 |
Time |
10:43 |
Sent To |
Z |
|
Notes |
2008-03-04 10:45:13 | REVISION TO LOCATION OF SUMMER KITCHEN AND A/C | | CONDENSERS OK FOR BUILDING. SHEET A-2. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-11-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-11-30 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-11-30 |
Time |
11:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-08-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-08-29 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-08-29 |
Time |
14:16 |
Sent To |
|
|
Notes |
2007-08-29 14:15:58 | 2004 FBC WITH 2007 SUPPLEMENT | | CONSTRUCT NEW SINGLE FAMILY RESIDENCE | | | | DENIED BY BUILDING | | | | 1)A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2)SUBMIT A COPY OF THE PAID RECEIPT FOR THE PALM | | BEACH COUNTY IMPACT FEES. | | | | 3) REVISE THE CODE EDITION SPECIFIED ON SHEET T1 TO THE | | 2004 FBC WITH 2007 SUPPLEMENT. | | | | 4) THE REAR QUADRANT OF THE STRUCTURE ABUTS A LAKE AND | | A GOLF COURSE, WHICH HAS EXPOSURE C-TYPE TERRAIN FOR A | | DISTANCE OF MORE THAN 600 FEET. THEREFORE,THE | | STRUCTURE IS LOCATED IN EXPOSURE CATEGORY C. PER | | R301.2.1.4 EXPOSURE CATEGORY. 3. EXPOSURE C. OPEN | | TERRAIN WITH SCATTERED OBSTRUCTIONS, INCLUDING SURFACE | | UNDULATIONS OR OTHER IRREGULARITIES, HAVING HEIGHTS | | GENERALLY LESS THAN 30 FEET (9144 MM) EXTENDING MORE | | THAN 1,500 FEET (457.2 M) FROM THE BUILDING SITE IN ANY | | QUADRANT. THIS EXPOSURE SHALL ALSO APPLY TO ANY | | BUILDING LOCATED WITHIN EXPOSURE B-TYPE TERRAIN WHERE | | THE BUILDING IS DIRECTLY ADJACENT TO OPEN AREAS OF | | EXPOSURE C-TYPE TERRAIN IN ANY QUADRANT FOR A DISTANCE | | OF MORE THAN 600 FEET (182.9 M). SHORT-TERM (LESS THAN | | TWO YEAR) CHANGES IN THE PRE-EXISTING TERRAIN EXPOSURE, | | FOR THE PURPOSES OF DEVELOPMENT, SHALL NOT BE | | CONSIDERED OPEN FIELDS. WHERE DEVELOPMENT BUILD OUT | | WILL OCCUR WITHIN THREE YEARS AND THE RESULTANT | | CONDITION WILL MEET THE DEFINITION OF EXPOSURE B, | | EXPOSURE B SHALL BE REGULATING FOR THE PURPOSE OF | | PERMITTING. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY, | | GRASSLANDS AND OCEAN OR GULF SHORELINES. THIS CATEGORY | | DOES NOT INCLUDE INLAND BODIES OF WATER THAT PRESENT A | | FETCH OF 1 MILE (1.61 KM) OR MORE OR INLAND WATERWAYS | | OR RIVERS WITH A WIDTH OF 1 MILE (1.61 KM) OR MORE (SEE | | EXPOSURE D). PLEASE REVISE THE EXPOSURE CATEGORY | | SPECIFIED ON THE PLANS AND REVISE THE COMPONENT AND | | CLADDING PRESSURES TO EXPOSURE C. | | | | 5) PLEASE INDICATE THAT THE INTERNAL PRESSURE | | COEFFICIENT ON T1 IS FOR BOTH POSITIVE AND NEGATIVE | | PRESSURES BY ADDING THE PLUS AND MINUS SIGNS. SEE | | ASCE7-02. | | | | 6)SHOW COMPLIANCE WITH R302.1 EXTERIOR WALLS. | | EXTERIOR WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM) | | SHALL HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE | | RATING WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL | | NOT EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM | | AN ADJACENT PROJECTION OR WALL. THE LEFT SIDE OF THE | | STRUCTURE IS LOCATED 5 FEET FROM THE PROPERTY LINE. | | INDICATE ON THE PLANS THAT THE DISTANCE TO THE ADJACENT | | STRUCTURE IS MORE THAN 6 FEET OR THAT THE ADJACENT LOT | | IS VACANT. | | | | 7) SUBMIT A DRAINAGE PLAN SHOWING COMPLIANCE WITH | | R401.3 DRAINAGE. | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS | | TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO | | DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE | | GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM | | OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048 | | MM). | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL | | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE | | PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. | | | | 8) PROVIDE CONNECTION DETAILS FOR THE TOP AND BOTTOM OF | | THE 4 X 6 X 3/16 " T.S. COLUMNS BETWEEN THE LIVING ROOM | | WINDOWS. SPECIFY FASTENERS, ETC. FBC * 106.1.2 | | | | 9) PROVIDE A DETAIL OF THE WINDOW BUCK TO STEEL COLUMN | | DETAIL FOR THE 4X6 STEEL COLUMNS AT LIVING ROOM | | WINDOWS. | | | | 10) PROVIDE AN ELEVATION OF THE EXTERIOR WALL AT THE | | BREAKFAST AND FAMILY ROOM. SPECIFY THE PRESSURES FOR | | THE WINDOW AT THE BREAKFAST ROOM. | | | | 11) THE FL PRODUCT APPROVAL NUMBER LISTED IN THE ANCHOR | | SCHEDULE ON A3 FOR THE USP RT16 HURRICANE TIE IS | | INCORRECT. THE FL NUMBER FOR THIS CONNECTOR IS FL565, | | THE ONE LISTED IS FOR THE RT16 FLAT AND TWIST STRAP | | CONNECTORS. PLEASE CORRECT. | | | | 12) THE DOUBLE OUT SWING FRONT DOORS, AS WELL AS, SOME | | OF THE OTHER PRODUCTS MAY NOT MEET THE INCREASED | | COMPONENT AND CLADDING PRESSURES OF THE EXPOSURE C | | CATEGORY. PLEASE REVIEW PRODUCT APPROVALS FOR ADEQUATE | | PRESSURES. | | | | 13) SUBMIT RATIONAL ANALYSIS FROM A FLORIDA LICENSED | | ENGINEER FOR THE EXTERIOR 18" X 18" ACCESS DOOR TO THE | | WHIRLPOOL TUB MOTOR SHOWING THAT THE DOOR IS CAPABLE OF | | WITH STANDING THE WINDLOAD PRESSURES. SPECIFY THE | | ANCHOR TYPE, EMBED DEPTH, ETC. PROVIDE MANUFACTURER'S | | SPECIFICATIONS. | | | | -ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-04-08 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-04-08 |
Time |
14:35 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2008-03-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-03-04 |
Time |
08:05 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-03-03 |
Time |
16:34 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2008-02-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-02-25 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-02-25 |
Time |
07:03 |
Sent To |
PC |
|
Notes |
2008-02-25 09:09:14 | | | | | REVISION DENIED | | | | 1} PER 553.791 FS, THESE PLANS MUST BE SENT TO THE | | PPIVATE PROVIDER FOR REVIEW PRIOR TO SUBMITTING THEM TO | | THIS DEPARTMENT. | | | | 2} THE ARCHITECT SHALL CLOUD OR INDICATE BY ANOTHER | | ACCEPTABLE METHOD USED BY THE INDUSTRY, THE REVISIONS | | ON THESE PLANS. | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-11-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-11-21 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-11-21 |
Time |
09:48 |
Sent To |
P |
|
Notes |
2007-11-21 10:52:14 | | | | | TO MIKE'S DESK./WRT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-08-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-21 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-08-21 |
Time |
07:42 |
Sent To |
P |
|
Notes |
2007-08-21 17:30:23 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | FLORIDA STATUTES 1/2007,2004 FBC AS AMENDED, CHAPTER | | 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | THESE COMMENTS REFER TO SHEET A7. | | | | 1} CIRCUIT # 40 IN PANEL "B" INDICATES A LOAD OF 3.6 | | KW. IN VIOLATION OF 210.23, LIMITING THE CIRCUIT | | AMPACITY TO 80% OF THE CIRCUIT RATING ( AT 20 AMPS). | | LIST THE CIRCUIT RATING AND CONDUCTOR SIZE SO | | COMPLIANCE WITH 310.16 MAY BE REVIEWED. NOTE: THE HIGH | | HATS LISTED ON THOSE CIRCUITS ARE NOT REQUIRED TO BE ON | | A SEPARATE CIRCUIT AND MAY BE PUT ON OTHER LIGHTING AND | | RECEPTACLE CIRCUITS. | | | | 2} SHEET A2 ANDA7 INDICATES IN A NOTE THATAHU #2, | | IN BEDROOM #2CLOSET, IS CEILING HUNG. SHEET M1 SYSTEM | | SPECIFICATIONS INDICATE THERE IS A 30 AMP FUSE IN THE | | AIR HANDLER. OVERCURRENT PROTECTION IN A CLOTHES CLOSET | | IS IN VIOLATION OF 240.24(D). ALSO THERE IS A | | DISCONNECT IN THE CLOSET AND IT IS UNCLEAR IF IT | | CONTAINS OCP. IF THE INSTALLATION IS INTENDED TO BE IN | | THE ATTIC RATHER THAN IN THE CLOSET, ARECEPTACLE PER | | 210.63, IS REQUIRED. | | | | 3} RECEPTACLES ARE REQUIRED TO BE ADDED OR RELOCATED TO | | COMPLY WITH 210.52(A) IN THE CLUB, LIVING AND MASTER | | BEDROOMS. | | | | 4} SHOW COMPLIANCE WITH R313.1. FBC "OUTSIDE EACH | | SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE | | BEDROOMS" AND NFPA-72, 11.5.1.1(2) "OUTSIDE OF EACH | | SEPARATE SLEEPING AREA, IN THE IMMEDIATE VICINITY OF | | THE SLEEPING ROOMS" FOR THE GUEST SUITE. | | | | 5} THE ENGINEERSNAME ON THE PLAN PROVIDER AFFIDAVIT | | AND SEAL, IS DIFFERENT THAN THE ONE ON FILE WITH DBPR. | | PLEASE CLARIFY. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2008-09-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-03 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-03 |
Time |
11:49 |
Sent To |
Z |
|
Notes |
2008-09-03 11:49:33 | TO "Z" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2008-08-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-26 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2008-08-26 |
Time |
08:55 |
Sent To |
Z |
|
Notes |
2008-08-26 08:56:02 | TO "ZONING" BOX. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2008-04-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-18 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-18 |
Time |
16:11 |
Sent To |
M |
|
Notes |
2008-04-18 16:13:07 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-04-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-17 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-17 |
Time |
09:24 |
Sent To |
B |
|
Notes |
2008-04-17 09:24:37 | TO "RMCDOUGAL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-04-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-03 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-03 |
Time |
14:43 |
Sent To |
E |
|
Notes |
2008-04-03 14:43:57 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-03-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-03 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-03 |
Time |
16:09 |
Sent To |
E |
|
Notes |
2008-03-03 16:10:03 | TO "BTROBAUG" DESK/REV--PRIVATE PROVIDER-- |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-02-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-12 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-12 |
Time |
14:57 |
Sent To |
E |
|
Notes |
2008-02-12 14:57:46 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-11-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-19 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-19 |
Time |
10:21 |
Sent To |
Z |
|
Notes |
2007-11-19 10:21:31 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-08-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-08-29 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-08-16 |
Time |
15:56 |
Sent To |
|
|
Notes |
2007-08-16 15:56:44 | TO "SFR" "Z" |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
2 |
Status |
P |
Date |
2008-09-05 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2008-09-05 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2008-09-05 |
Time |
08:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
F |
Date |
2008-08-27 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2008-08-27 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2008-09-05 |
Time |
08:47 |
Sent To |
|
|
Notes |
2008-08-27 09:44:59 | LANDSCAPE***FAILED*** | | | | PROVIDE THE SIZE AND SPACING FOR ALL PROPOSED PLANT | | MATERIAL. | | | | PALM TREES MAY BE SUBSTITUTED FOR NOT MORE THAN 35% OF | | THE SHADE OR FLOWERING TREES REQUIRED.BECAUSE 10 | | TREES ARE REQUIRED, AT LEAST 7 SHADE OR FLOWERING TREES | | ARE REQUIRED.ONLY 5 HAVE BEEN PROVIDED. | | | | THE PROPOSED TREES ALONG THE NORTH PERIMETER OF THE | | SITE SHALL BE KEPT OUT OF THE GRAVEL.PLEASE PROVIDE A | | SEPARATOR TO CONTAIN THE GRAVEL AND KEEP IT AWAY FROM | | THE ROOT BALL OF THE TREES. | | | | PROVIDE THE PLANT LIST FOR LOT #23. | | | | CONTACT INFORMATION: | | ROBERT KUSSNER @ 822-1462 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2008-04-21 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-04-21 |
Time |
09:56 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-04-21 |
Time |
09:56 |
Sent To |
|
|
Notes |
2008-04-21 09:56:51 | REVISION TO MECH. PLANS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
N |
Date |
2008-03-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-03-04 |
Time |
11:52 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2008-03-04 |
Time |
11:52 |
Sent To |
|
|
Notes |
2008-03-04 11:53:27 | REVISION TO BUILDING PLANS PAGES A2 AND A7. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-11-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-11-27 |
Time |
12:18 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-11-27 |
Time |
12:18 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-08-20 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-08-20 |
Time |
14:22 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-08-20 |
Time |
14:22 |
Sent To |
E |
|
Notes |
2007-08-20 14:33:48 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER | | 1 CITY OF WEST PALM BEACH AMENDMENTS. | | | | *** DENIED *** | | 1) ENERGY CALCULATIONS LINE 11A STATE THE AIR HANDLER | | IS LOCATED INTERIOR, MECHANICAL PLANS SHOW THE AIR | | HANDLERS ARE LOCATED IN THE GARAGE AND ATTIC, PLEASE | | CORRECT ENERGY CALCULATIONS. | | | | 2) ENERGY CALCULATIONS LINE 12 A, B, AND C STATE TWO | | FIVE TON AND ONE TWO TON A/C SYSTEMS ARE BEING | | INSTALLED AND COOLING LOAD CALCULATION SHOW THAT IN | | WHATS NEEDED, BUT MECHANICAL PLANS SHOW ONE FIVE TON, | | ONE TWO TON, AND ONE THREE TON. THE THREE MUST COINCIDE | | PLEASE CORRECT MECHANICAL PLANS. SEE 2004 FBC | | 13-607.1.ABC.1. | | | | 3) MECHANICAL PLANS NEED THE JOB ADDRESS ON THEM, SEE | | 2004 FBC/ CITY WPB AMEND. 106.1.3. | | | | 4) SEE F.S. 553.719 (4) (C) (C) FOR PRIVATE PROVIDER | | ACKNOWLEDMENT MISSING.AN ACKNOWLEDGMENT FROM THE FEE | | OWNER IN SUBSTANTIALLY THE FOLLOWING FORM: | | I HAVE ELECTED TO USE ONE OR MORE PRIVATE | | PROVIDERS TO PROVIDE BUILDING CODE PLANS REVIEW AND/OR | | INSPECTION SERVICES ON THE BUILDING OR STRUCTURE THAT | | IS THE SUBJECT OF THE ENCLOSED PERMIT APPLICATION, AS | | AUTHORIZED BY S. 553.791, FLORIDA STATUTES. I | | UNDERSTAND THAT THE LOCAL BUILDING OFFICIAL MAY NOT | | REVIEW THE PLANS SUBMITTED OR PERFORM THE REQUIRED | | BUILDING INSPECTIONS TO DETERMINE COMPLIANCE WITH THE | | APPLICABLE CODES, EXCEPT TO THE EXTENT SPECIFIED IN | | SAID LAW. INSTEAD, PLANS REVIEW AND/OR REQUIRED | | BUILDING INSPECTIONS WILL BE PERFORMED BY LICENSED OR | | CERTIFIED PERSONNEL IDENTIFIED IN THE APPLICATION. THE | | LAW REQUIRES MINIMUM INSURANCE REQUIREMENTS FOR SUCH | | PERSONNEL, BUT I UNDERSTAND THAT I MAY REQUIRE MORE | | INSURANCE TO PROTECT MY INTERESTS. BY EXECUTING THIS | | FORM, I ACKNOWLEDGE THAT I HAVE MADE INQUIRY REGARDING | | THE COMPETENCE OF THE LICENSED OR CERTIFIED PERSONNEL | | AND THE LEVEL OF THEIR INSURANCE AND AM SATISFIED THAT | | MY INTERESTS ARE ADEQUATELY PROTECTED. I AGREE TO | | INDEMNIFY, DEFEND, AND HOLD HARMLESS THE LOCAL | | GOVERNMENT, THE LOCAL BUILDING OFFICIAL, AND THEIR | | BUILDING CODE ENFORCEMENT PERSONNEL FROM ANY AND ALL | | CLAIMS ARISING FROM MY USE OF THESE LICENSED OR | | CERTIFIED PERSONNEL TO PERFORM BUILDING CODE INSPECTION | | SERVICES WITH RESPECT TO THE BUILDING OR STRUCTURE THAT | | IS THE SUBJECT OF THE ENCLOSED PERMIT APPLICATION. | | | | 5) ENGINEERS NAME ON PRIVATE PROVIDER AFFIDAVIT JOHN F. | | DESNOYERS, IS NOT THE SAME NAME ON LICENSE # 47885 | | (JEAN F. DESNOYERS) PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL: [email protected]. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2008-03-04 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-03-04 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-03-04 |
Time |
09:10 |
Sent To |
B |
|
Notes |
2008-03-04 09:17:39 | NOTE: REVISION HAS NO PLUMBING CHANGES, HOWEVER A GAS | | REVISION WILL BE REQUIRED FOR GAS PERMIT #08010729 FOR | | THE RELOCATED BBQ. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2007-11-26 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-11-26 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-11-26 |
Time |
14:35 |
Sent To |
M |
|
Notes |
2007-11-26 14:45:49 | CONTRACTOR INFORMATION | | (SHEET A2 IS INDICATING GAS APPLIANCES) | | NOTE: GAS PERMIT REQUIRED. GAS OR PLUMBING CONTRACTOR | | TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL GAS | | INSPECTIONS TO BE COMPLETE BEFORE FINAL INSPECTION. | | | | | | ****************PROVISO**************** | | (D) 708.9 ACCESS. ACCESS SHALL BE | | PROVIDED TO ALL CLEANOUTS. | | **NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE | | LOCATED AT 4' A.F.F. FACING THE UTILITY ROOM OR AT THE | | BASE OF THE STACK FACING THE 2-CAR GARAGE. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-08-22 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-08-22 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-08-22 |
Time |
15:24 |
Sent To |
B |
|
Notes |
2007-08-22 16:07:31 | DENIED | | REFERENCE: | | ** FBC-2004 PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1. SHEET A6 SANITARY ISOMETRIC RISER DIAGRAM DOES NOT | | REFLECT THE FLOOR PLAN ON SHEET A2: PER FBC-2004 | | CHAPTER 1, THE CITY OF WEST PALM BEACH AMENDMENTS, | | SECTION 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE | | LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND | | SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS | | OF THIS CODE AND RELAVENT LAWS, ORDINANCES, RULES AND | | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. | | | | A} THE BRANCH TO THE POWDER ROOM BATH SHOULD BE BEFORE | | THE UTIL. THE WAY THE ISOMETRICT IS DRAWN. IF IT IS THE | | INTENT TO LEAVE THE BRANCH TO THE POWDER ROOM WHERE IT | | IS ON THE ISOMETRIC, PLEASE INDICATE THE REQUIRED | | OFFSETS ON THE RESUBMITTAL TO REFLECT THE FLOOR PLAN. | | | | B} LAV IS MISSING FROM BATH 3. PLEASE CORRECT ON THE | | RESUBMITTAL. | | | | C} DISHWASHER IS INDICATED ON THE WRONG SIDE OF THE | | DOUBLE BOWL SINK W/DISP. AND PER FBC-2004 PLUMBING, | | SECTION 802.1.6 DOMESTIC DISHWASHING MACHINES SHALL | | DISCHARGE INTO A WYE-BRANCH FITTING ON THE TAILPIECE OF | | THE KITCHEN SINK OR THE DISHWASHER CONNECTION OF A FOOD | | WASTE GRINDER. PLEASE CORRECT ON THE RESUBMITTAL. | | | | D} HER BATH DOES NOT REFLECT THE FLOOR PLAN ON SHEET | | A2: | | | | A) SHEET A2 DOES NOT INDICATE A BIDET, BUT THE | | SANITARY ISOMETRIC IS INDICATING A BIDET ON SHEET A6. | | PLEASE CLARIFY AND CORRECT ON THE RESUBMITTAL. | | | | B) LAV IS BEING INDICATED IN THE WRONG PLACE. PLEASE | | CORRECT ON THE RESUBMITTAL. | | | | 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 | | RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A | | PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING | | ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT | | LOCATIONS. | | NOTE: NOT ALL PIPES OR TRAPS ARE SIZED ON THE SANITARY | | ISOMETRIC RISER DIAGRAM ON SHEET A6. PLEASE CORRECT | | THIS ON THE RESUBMITTAL. | | | | 3. SHEET A2 IS INDICATING GAS APPLIANCES: | | | | **CONTRACTOR INFORMATION** | | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | BEFORE FINAL INSPECTION. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2008-04-03 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-04-03 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-04-03 |
Time |
14:18 |
Sent To |
PC |
|
Notes |
2008-04-03 14:20:05 | ***APPROVED - REVISION - CHANGING LOCATION OF OUTDOOR | | KITCHEN AND A/C EQUIPMENT*** | | | | *OBTAINED DRAINAGE EASEMENT HOLDER APPROVAL. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2008-03-04 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-03-04 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-03-04 |
Time |
11:08 |
Sent To |
M |
|
Notes |
2008-03-04 11:12:06 | ***FAILED - REVISION - CHANGING LOCATION OF OUTDOOR | | KITCHEN AND A/C EQUIPMENT*** | | | | | | 1)AS THE NEWLY SUBMITTED FLOOR PLAN/ELECTRIC PLAN | | (SHEET A2/A7) SHOW THE A/C MECHANICAL EQUIPMENT IN A | | DIFFERENT LOCATION FROM WHAT WAS ORIGINALLY APPROVED, | | INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C EQUIPMENT | | TO ALL PROPERTY LINES.AS PER SECTION 94-305(B)(4) OF | | THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT PROJECT MORE | | THAN 4 FEET INTO A REQUIRED SETBACK. | | | | NOTE:NO STRUCTURE/EQUIPMENT SHALL BE BUILT WITHIN THE | | 20 FOOT DRAINAGE EASEMENT . | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | SENT TO "M" - TG |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-11-20 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-11-20 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-11-20 |
Time |
16:48 |
Sent To |
E |
|
Notes |
2007-11-20 16:49:48 | ***APPROVED - RESUB #1*** | | | | | | | | SENT TO "E" - BT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-08-20 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-08-20 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-08-20 |
Time |
11:06 |
Sent To |
E |
|
Notes |
2007-08-20 11:07:58 | ***FAILED*** | | | | | | 2)PROVIDE SETBACK DIMENSIONS FROM A/C EQUIPMENT TO | | THE PROPERTY LINES. | | | | 3)ELEVATION DIMENSIONS TO BE MEASURED FROM GRADE. | | | | 4)PLEASE PROVIDE A LANDSCAPE PLAN SHOWING COMPLIANCE | | WITH SECTION 94-442 OF THE CITY OF WEST PALM BEACH | | ZONING AND LAND DEVELOPMENT REGULATIONS. | | | | 5)PROVIDE TOTAL SQUARE FOOTAGE OF PROPOSED DRIVEWAY | | WITHIN THE FRONT YARD (FROM FRONT PROPERTY LINE TO THE | | FRONT OF THE PRINCIPAL STRUCTURE). | | | | NOTE:MUST MAINTAIN THE LESSOR OF 1,000 SQ.FT. OR 75% | | OF THE FRONT YARD AS LANDSCAPED MATERIAL. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|