Plan Review Details - Permit 07080401
Plan Review Stops For Permit 07080401 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-10-16 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-10-13 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-10-13 |
Time |
08:09 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2007-08-30 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-08-30 |
Time |
12:21 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-08-30 |
Time |
10:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-10-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-10-09 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-10-09 |
Time |
11:31 |
Sent To |
B |
|
Notes |
2007-10-09 11:33:18 | LIGHTING NOTED AS *EXISTING*. | | | | PLANS ROUTED TO BUILDING AS THERE IS A SHEET A-2 IN | | EACH SET NOT STAMPED. THESE MAY BE NEW? |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-08-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-28 |
Time |
07:37 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-28 |
Time |
07:37 |
Sent To |
|
|
Notes |
2007-08-28 07:37:11 | | | | | ** DENIED ** | | | | 1) NOTE: PLEASE SEE FBC 13-415.1.ABC.1.1, 13-101 AS A | | NEW AUTOMATED DEVICE OF SOME KIND WILL BE REQUIRED FOR | | SWITCH LOCATIONS. | | PLEASE PROVIDE AND SHOW THE LOCATION OF THE NEW DEVICE | | OR DEVICES DEPENDING ON THE TYPE OF DEVICE AND COVERAGE | | FOR CONTROLS. | | PLEASE PROVIDE THE MAXIMUM TIME(S) FOR DEVICE(S). | | | | 2) NOTE: PLEASE PROVIDE INFORMATION FOR CIRCUITING OF | | WHAT IS BEING CALLED EXISTING EXIT AND EMERGENCY LIGHTS | | PER 700.12F OF THE 2005 NEC> ( ONE MISSING CONNECTION | | OF CIRCUIT) | | | | 3) NOTE: PLEASE SEE THE OPEN OFFICE AREA WHERE THE | | EMERGENCY LIGHT FIXTURE IS BEING RELOCATED DOES NOT | | SEEM TO BE PLACED IN THE OPEN OFFICE AREA. | | PLEASE SEE THE MINIMUM FT CANDLES FOR EGRESS PER LS 101 | | 7.8 AND 7.9 | | PLEASE MOVE THE FIXTURE AS SHOWN OR PROVIDE AN | | ADDITIONAL FIXTURE. | | FAC 61G15-33.004 | | | | 4) NOTE: PLEASE PROVIDE THE MAXIMUM LIGHTING POWER | | DENSITIES PER 13-415.2 | | | | 5) NOTE: PLEASE PROVIDE A PANEL SCHEDULE FOR NEW AND/OR | | EXISTING CIRCUITS. | | 408.4. | | FBC 106.3.5.1.2, 106.1.2 | | | | 6) NOTE: PLEASE STATE THE FOLLOWING CODES ON PLANS. | | 2005 NFPA-70 (NEC) | | 2003 NFPA-101 | | 2002 NFPA-72 | | | | ** THE SCOPE OF WORK IN MINOR IN NATURE AND THERE ARE | | ONLY A FEW ITEMS NEEDED ON PLANS. | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2007-08-30 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-08-30 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-08-30 |
Time |
13:05 |
Sent To |
|
|
Notes |
2007-08-30 13:23:38 | *****APPROVED***** | | | | | | PLAN SHEETS A-1 AND E-1) WERE STAMPED, INITIALED, AND | | DATED. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-10-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-09 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-09 |
Time |
09:05 |
Sent To |
|
|
Notes |
2007-10-09 09:06:15 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-08-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-08-30 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2007-08-14 |
Time |
11:17 |
Sent To |
|
|
Notes |
2007-08-27 08:41:24 | TO "BOB"#12 | 2007-08-14 11:18:06 | WAITING FOR "BOB" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2007-08-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-08-30 |
Time |
15:28 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-08-30 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-08-27 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-08-27 |
Time |
15:34 |
Sent To |
|
|
Notes |
2007-08-27 15:34:37 | *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|
|