Plan Review Details - Permit 07080268
Plan Review Stops For Permit 07080268
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-01-23 Cont ID  
Sent By mjacobs Date 2008-01-23 Time 14:03 Rev Time 0.00
Received By mjacobs Date 2008-01-23 Time 12:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-11-19 Cont ID  
Sent By mjacobs Date 2007-11-19 Time 10:30 Rev Time 0.00
Received By mjacobs Date 2007-11-19 Time 07:56 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-25 Cont ID  
Sent By mjacobs Date 2007-08-25 Time 13:11 Rev Time 0.00
Received By mjacobs Date 2007-08-25 Time 08:43 Sent To  
Notes
2007-08-25 13:10:59 
 BUILDING PLAN REVIEW
 PERMIT: 07080268
 ADD: 3901 36TH CT.
 CONT: ARCCW INC.
 TEL: (561)201-5340
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 3)110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OF THE CODE UNDER WHICH
 THE PROJECT IS DESIGNED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED
 F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED.
 G) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT
 . -------------------------------------
 ) NUMBER OF UNITS
 ) NUMBER OF FLOORS
 ) NUMBER OF BEDROOMS
 ) NUMBER OF ROOMS
 ) NUMBER OF BEDROOMS
 ) SQ. FT. LIV SPACE/ FL
 ) SQ. FT. FOOTPRINT
  
 4)ARE THE NEW WINDOWS IMPACT WINDOWS? ACCORDING TO
 THE PRODUCT APPORVALS THEY ARE. IF NOT PROVIDE THE
 CORRECT PRODUCT APPROVALS. ALL PRODUCT APPROVALS SHALL
 BE APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR
 TO SUBMITTAL.
  
 5)THE SHUTTER INSTALLATION SCHEDULE SUBMITTED IS
 MISSING SOME REQUIRED INFORMATION. ALSO ON THE PRODUCT
 APPROVAL, CIRCLE THE ITEMS WHICH WILL BE USED. EACH
 OPENING SHALL HAVE ITS OWN INFORMATION STATED ON THE
 SCHEDULE. INDICATE THE FASTENING METHOD FROM PAGE #2 OR
 #3.
  
 6)PROVIDE ELEVATION DRAWINGS SHOWING WHAT IS ABOVE
 THE FIRE DAMAGE AREA. WHAT MATERIAL WILL BE USED TO
 REPLACE EXISTING FLOOR ABOVE? IS THE AREA ABOVE THE
 FIRE DAMAGE CEILING PART OF APT #105 OR IS IT A
 DIFFERENT UNIT? PLEASE INDICATE IF THERE IS MORE THAN
 ONE UNIT AFFECTED BY THE FIRE.
  
 7)INDICATE THE GRADE AND SPECIES OF WOOD WHICH WILL
 BE USED TO DO THE FLOOR JOIST REPAIR. FBC. 2308.8
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-01-28 Cont ID  
Sent By dpalmer Date 2008-01-28 Time 10:14 Rev Time 0.00
Received By dpalmer Date 2008-01-28 Time 10:14 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2008-01-15 Cont ID  
Sent By dpalmer Date 2008-01-15 Time 20:17 Rev Time 0.00
Received By dpalmer Date 2008-01-15 Time 20:17 Sent To  
Notes
2008-01-15 20:17:57** DENIED 3RD REVIEW **
  
 1) NOTE: PLEASE SEE THE NOTES FROM PREVIOUS REVIEWS
 WHICH CLEARLY STATE PLANS MUST CONTAIN A DESIGN
 PROFESSIONAL TAKING RESPONSIBILITY OF THE PLANS PER
 481.229, 471.025 OR 468.
 PLEASE SEE NONE OF THESE HAVE BEEN DONE.
 THE PREVIOUS PLANS CONTAINED A TITLE BLOCK FOR AN
 ENGINEER AND NOW THAT TITLE BLOCK HAS BEEN REMOVED?
  
 2) NOTE: PLEASE SEE THE LOAD CALCULATIONS AS SUBMITTED
 ARE NOW ONLY BEING SUBMITTED FOR THE FIRST TIME UNDER
 RESIDENTIAL FOR THE FIRST REVIEW.
 PLEASE SEE NEC 220.60 AS THE HIGHER OF THE TWO LOADS
 FOR A/C SHALL BE FIGURED. AS THE OVER CURRENT
 PROTECTION FOR THE CU IS SHOWN SUBSTANTIALLY HIGHER IS
 THIS LOAD FOR THE CU HIGHER?
 IF SO, PLEASE ADJUST CALCULATIONS.
 PLEASE KNOW IF THIS NOT HIGHER THEN THESE ARE OK.
  
 PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEW WERE NOT
 COMPLETELY ADDRESSED BY LISTING THE ARC FAULT PROTECTED
 CIRCUITS AS REQUIRED PER 408.4 AND 210.12. INSTEAD THE
 CODE SECTION WAS QUOTED ON THE PLANS.
  
 ** PLEASE SEE ITEM # 2 FOR THE ABOVE MAY BE PART OF A
 PROVISO HOWEVER THE PLANS SHALL CONTAIN A DESIGN
 PROFESSIONAL AS STATED ABOVE.
  
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY
 COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE
 DO NOT HESITATE IN CONTACTING THIS OFFICE.
 PLEASE SEE BELOW FOR CONTACT INFORMATION.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-11-09 Cont ID  
Sent By dpalmer Date 2007-11-09 Time 16:48 Rev Time 0.00
Received By dpalmer Date 2007-11-09 Time 16:48 Sent To  
Notes
2007-11-09 16:49:59** DENIED 2ND REVIEW **
  
 ** AS STATED ON PREVIOUS REVIEW, PLEASE SUBMIT
 COMPLETED PLANS FOR MINIMUM NEC COMPLIANCE.
 PLEASE SEE MANY OF THE CODE SECTIONS PREVIOUSLY GIVEN
 ARE NOT ON PLANS.
  
  
 1) NOTE:PLEASE REFERENCE ALL CODES ON PLANS AS
 PREVIOUSLY STATED AND REQUIRED BY FBC.
 2004 FBC/W2006 REVISIONS.
 2005 NFPA-70
 2002 NFPA-72
 2003 NFPA-101
  
 ** SOME OF THESE MAY BE SHOWN ALREADY.
  
 2) NOTE: PLEASE SUBMIT LOAD CALCULATIONS FOR
 RESIDENTIAL DWELLING. NEC 220
  
 3) NOTE: PLEASE SEE MIN VA FOR WASHER/LAUNDRY CIRCUIT
 SHALL MEET 220.53.
 1500 MIN.
  
 4) NOTE: PLEASE CORRELATE RISER WITH ACTUAL ELECTRICAL
 SERVICE AT LOCATION.
 PLANS INDICATE A METER CENTER AND RISER SHOWS A
 SEPARATE SERVICE WITH METER MAIN COMBO PANEL.
 THESE ARE NOT COORDINATED OR CLEAR.
 230.2
 FBC 106.3.5.4, 106.1.2
  
 5) NOTE: PLANS ARE NOT SIGNED DATED OR SEALED BY THE
 DESIGNER OF RECORD.
 FS471.025
  
 6) NOTE: PLEASE LIST ALL ARC FAULT CIRCUITS PER 210.12
  
 7) NOTE: PLANS MISSING EGRESS LIGHTING AT DOOR. 210.70,
 LS 101 7.8
  
 8) NOTE: PLANS MISSING A/C CU DISCONNECT, GFI ETC.
 PLEASE SEE 210.8A, 210.63, 440.11
  
 PLEASE SUBMIT COMPLETED PLANS.
  
  
 ** PLEASE KNOW AS THERE ARE ITEMS WHICH ARE NOT SHOWN
 AT THIS TIME, A COMPLETE REVIEW FOR CODE COMPLIANCE CAN
 NOT BE DONE.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-08-27 Cont ID  
Sent By dpalmer Date 2007-08-27 Time 20:27 Rev Time 0.00
Received By dpalmer Date 2007-08-27 Time 20:27 Sent To  
Notes
2007-08-27 20:28:012007-08-27 20:28:01
  
 ** DENIED **
  
 1) NOTE: PLEASE SEE FBC R313 AS NEW SMOKE ALARM/DICTION
 DEVICES ARE REQUIRED INSIDE AND OUTSIDE ALL SLEEPING
 ROOMS. NFPA-72 11.5.1.1, 11.8.3
  
 2) NOTE: PLEASE INDICATE THE NEW AIC RATING FOR NEW
 MAINS AND SERVICE EQUIPMENT.
 110.9, FBC 106.1.2, 106.1.1
  
 3) NOTE: PLEASE SEE MISSING EQUIPMENT GROUNDING
 CONDUCTOR AFTER THE FIRST MEANS OF DISCONNECT AS
 REQUIRED PER 250.110, 250.122, 250.24 ETC.
  
 4) NOTE: PLEASE SEE THE RISER SEEMS TO SHOW ONLY ONE
 SERVICE AND NO INDICATION OF THE EXISTING OTHER MAINS
 ETC.
 THIS IS AN APARTMENT, AS APPLIED AND PLEASE SHOW THE
 BUILDING SERVICE, LOCATION ETC. 230.70,230.71,230.72.
  
 5) NOTE: PLEASE INDICATE THE CIRCUITS WHICH ARE
 REQUIRED TO BE SPECIFIC TO ROOMS ARE AREAS IN WHICH
 THEY FEED.
 PLEASE SHOW THE CIRCUITING ON PLANS AND CORRELATE WITH
 THE SUBMITTED PANEL SCHEDULE.
 408.4, 240.4, 310.16.
 FBC 106.3.5.1.2, 106.3.5.4, 106.1.2, 106.1.1
  
 6) NOTE: PLEASE SEE THE OVER CURRENT PROTECTION ON THE
 AHU IS TOO HIGHFOR THE 5KW HEAT SHOWN.
 PLEASE ADJUST. (30AMP)?
  
 7) NOTE: PLEASE SEE THE MINIMUM LOAD FOR THE WATER
 HEATER IS TO BE SIZED AT 125%.
 422.13
 ADJUST LOAD CALCULATIONS.
  
  
  
 PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-01-24 Cont ID  
Sent By mawillia Date 2008-01-24 Time 10:25 Rev Time 0.00
Received By mawillia Date 2008-01-24 Time 10:04 Sent To E
Notes
2008-01-24 10:19:37*****APPROVED****
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE
 BEEN ADDRESSED;PLAN SHEETS A-2 AND A-4 WERE STAMPED,
 INITIALED, AND DATED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2007-11-16 Cont ID  
Sent By mwennerg Date 2007-11-16 Time 10:34 Rev Time 0.00
Received By mwennerg Date 2007-11-16 Time 10:34 Sent To  
Notes
2007-11-16 10:43:19***DENIED***
  
 1) OK
  
 2) OK
  
 3) SHEET A2 HAS BEEN REFERENCED FOR CORRECTION BUT NO
 NOTE WAS FOUND. PLEASE BE ADVISED THAT IN ADDITION TO
 APPLICABLE BUILDING CODES, WORK, SPECIFICALLY LIFE
 SAFETY SHALL COMPLY WITH NFPA 101, 2003 EDITION.
  
 4) SHEET A2 WAS REFERENCED FOR CORRECTION BUT NO NOTE
 WAS FOUND. PLEASE ADD TO PLANS.
  
 5) INTERIOR FINISH CLASSIFICATION TO BE PROVIDED IN
 TERMS OF CLASS A,B,ORC. INFORMATION SHALL BE SPECIFIC
 TO THIS SCOPE OF WORK AND NOT GENERAL.
  
 6) SMOKE ALARM LOCATIONS HAVE BEEN ADDED TO PLANS.
 SHEET A4 DOES REFERENCE SMOKE DETECTORS UNDER
 ELECTRICAL NOTES. PLEASE CORRELATE INFORMATION AS THE
 TERM SMOKE DETECTOR WOULD INDICATE A FIRE ALARM
 SYSTEM.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-08-29 Cont ID  
Sent By mawillia Date 2007-08-29 Time 15:41 Rev Time 0.00
Received By mawillia Date 2007-08-29 Time 15:12 Sent To  
Notes
2007-08-29 15:35:45*****UNSAT****
  
  
 1.ON SHEET A1, THE SITE MAP REFERENCES NORHTWEST 36TH
 STREET, NORTHWEST 36TH COURT, AND AUSTRALIAN BOULEVARD.
 THE CORRECT VERBAGE FOR THOSE ROADWAYS ARE:36TH
 STREET, 36TH COURT, AND NORTH AUSTRALIAN AVENUE.
  
 2.THE UNIT NUMBER OF THE ADDRESSED PROJECT LOCATED IN
 THE TITLE BLOCK OF EACH SUBMITTED PLAN SHEET AND ALSO
 SHOWN ON THE SITE MAP DOES NOT CORRELATE WITH THE UNIT
 NUMBER (105-B) AS RECORDED IN THE CITY'S PERMITTING
 SYSTEM OR THAT ON THE PERMIT APPLICATION.
  
 3.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 4.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241
  
 5.SPECIFY THE INTERIOR FINISH MATERIAL FOR ANY
 REPLACED DRYWALL AND/OR CEILING IN TERMS OF CLASS A,
 CLASS B, OR CLASS C.
  
 6.SHOW THE LOCATION OF THE SMOKE ALARMS IN THE UNIT.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-01-15 Cont ID  
Sent By adarroug Date 2008-01-15 Time 09:40 Rev Time 0.00
Received By adarroug Date 2008-01-15 Time 09:40 Sent To  
Notes
2008-01-15 09:41:13TO "BOB"#3

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-11-07 Cont ID  
Sent By adarroug Date 2007-11-07 Time 16:06 Rev Time 0.00
Received By adarroug Date 2007-11-07 Time 16:06 Sent To  
Notes
2007-11-09 11:51:19TO "BOB"#13
2007-11-07 16:06:33WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-31 Cont ID  
Sent By mperson Date 2007-08-31 Time 16:36 Rev Time 0.00
Received By mperson Date 2007-08-09 Time 09:50 Sent To  
Notes
2007-08-23 13:28:18TO "BOB"#11
2007-08-09 09:51:41WAITING FOR COMM BOARD.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-08-24 Cont ID  
Sent By tgordon Date 2007-08-24 Time 08:50 Rev Time 0.20
Received By tgordon Date 2007-08-24 Time 08:50 Sent To  
Notes
2007-08-24 08:50:50NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 1 Status N Date 2007-08-31 Cont ID  
Sent By mperson Date 2007-08-31 Time 16:29 Rev Time 0.00
Received By mperson Date 2007-08-31 Time 16:29 Sent To  
Notes
2007-08-31 16:31:13NOTE: THERE ARE NO PLUMBING PLANS SUBMITTED, AND NO
 PLUMBING PERMT NUMBER APPLIED FOR AT THIS TIME.

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-27 Cont ID  
Sent By choops Date 2007-08-27 Time 15:31 Rev Time 0.00
Received By choops Date 2007-08-27 Time 15:31 Sent To  
Notes
2007-08-27 15:31:16*ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK
 DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE.