Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-09-21 Cont ID  
Sent By shill Date 2007-09-21 Time 11:52 Rev Time 0.00
Received By shill Date 2007-09-21 Time 11:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-09-17 Cont ID  
Sent By shill Date 2007-09-17 Time 07:36 Rev Time 0.00
Received By shill Date 2007-09-17 Time 07:36 Sent To  
Notes
2007-09-17 07:39:18****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 FROM PREVIOUS LISTS:
  
 1.)SEE SHEET 14 OF THE PRODUCT APPROVAL.AN EDGE
 DISTANCE OF 3" REQUIRES A .83 FACTOR.
  
 3RD REVIEW - A NOTE WAS INCLUDED WHICH DISPUTED THE
 PREVIOUS LISTS.PART OF THE NOTE STATED THAT THE
 PREVIOUS INSTALLATION SCHEDULE EDGE DISTANCE WAS
 REVISED TO THE WAY THAT I WANTED IT.PLEASE NOTE THAT
 EDGE DISTANCE IS DETERMINED BY JOB CONDITIONS AND THE
 CONTRACTOR.YOU MAY USE ANY CODE COMPLIANT EDGE
 DISTANCE ON THE PRODUCT APPROVAL (2" AND OVER FOR
 CONCRETE/BLOCK SUBSTRATES) BUT IF YOU USE A DIMENSION
 LESS THAN 3 1/2", THEN YOU NEED TO APPLY THE FACTOR AS
 SHOWN ON PAGE 14.I HAVE DISCUSSED THIS WITH TRACY;
 PLEASE HAVE HIM CONTACT ME IF YOU NEED FURTHER
 ASSISTANCE.
  
  
 ***REVISED***
  
 CONTRACTOR INFORMED ME THAT THERE IS A SECOND
 INSTALLATION SCHEDULE IN THE PACKAGE.THE SECOND ONE
 HAS A 3" EDGE DISTANCE.THE FACTOR WAS STILL NOT
 APPLIED ON EITHER INSTALLATION SCHEDULE, BOTH STATE 10"
 FOR CONNECTION TYPE A.FOR 2" EDGE DISTANCE, THIS
 SHOULD BE 5" SPACING.FOR 3 1/2" EDGE DISTANCE, THIS
 SHOULD BE 8.3.
  
 THE LETTER INCLUDED STATES THAT TRACY FEELS THAT I WAS
 INCORRECT IN MY FIRST CORRECTION LIST.I AM RETAINING
 THE LETTER, BOTH INSTALLATION SCHEDULES, AND THE
 PRODUCT APPROVAL.I BELIEVE THAT I GOT THIS ISSUE
 RESOLVED WITH TRACY ON FRIDAY, 9/14, THE DAY AFTER THE
 LETTER WAS WRITTEN.IF YOU STILL FEEL THAT I AM IN
 ERROR, PLEASE HAVE TRACY FIRST CONTACT THE TECHNICAL
 REPRESENTATIVE FOR THE SHUTTERS, AND IF HE AGREES WITH
 TRACY, PLEASE HAVE HIM CONTACT ME.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-09-12 Cont ID  
Sent By shill Date 2007-09-12 Time 14:55 Rev Time 0.00
Received By shill Date 2007-09-12 Time 14:55 Sent To  
Notes
2007-09-12 15:01:09****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 FROM PREVIOUS LIST:
  
 1.)SEE SHEET 14 OF THE PRODUCT APPROVAL.AN EDGE
 DISTANCE OF 3" REQUIRES A .83 FACTOR.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-31 Cont ID  
Sent By shill Date 2007-08-31 Time 07:35 Rev Time 0.00
Received By shill Date 2007-08-31 Time 07:35 Sent To  
Notes
2007-08-31 07:38:10****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.)SEE SHEET 14 OF THE PRODUCT APPROVAL.AN EDGE
 DISTANCE OF 3" REQUIRES A .83 FACTOR.
  
 2.)SPAN IS GREATER THAN 9'.IF THE OPENING IS 106",
 WALL MOUNT, SPAN SHOULD BE APPROXIMATELY 109" PER
 MANUFACTURER, WHICH IS 9'1" FOR A 3" EDGE DISTANCE TOP
 AND BOTTOM.PLEASE CLARIFY HOW YOU'VE ARRIVED AT THIS
 SPAN BASED ON THE INFORMATION PROVIDED.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-09-20 Cont ID  
Sent By adarroug Date 2007-09-20 Time 11:07 Rev Time 0.00
Received By adarroug Date 2007-09-20 Time 11:07 Sent To B
Notes
2007-09-20 11:07:20TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-09-14 Cont ID  
Sent By adarroug Date 2007-09-14 Time 08:46 Rev Time 0.00
Received By adarroug Date 2007-09-14 Time 08:46 Sent To B
Notes
2007-09-14 08:46:48TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-10 Cont ID  
Sent By adarroug Date 2007-09-10 Time 16:19 Rev Time 0.00
Received By adarroug Date 2007-09-10 Time 16:19 Sent To B
Notes
2007-09-10 16:20:05TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-31 Cont ID  
Sent By shill Date 2007-08-31 Time 07:39 Rev Time 0.00
Received By shill Date 2007-08-08 Time 18:37 Sent To  
Notes
2007-08-08 18:37:28SENT TO MISC BOX #01 MMILLER