Plan Review Stops For Permit 07080145 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-03-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-03-31 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-03-31 |
Time |
09:54 |
Sent To |
|
|
Notes |
2008-03-31 09:55:18 | BUILDING REVISION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-03-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-03-28 |
Time |
18:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-03-28 |
Time |
18:06 |
Sent To |
PC |
|
Notes |
2008-03-28 18:15:29 | BUILDING REVISION CHECKLIST: | | | | 1- NEW FOOTING REVISION ALSO SHOWS A NEW CONCRETE BLOCK | | WALL BECAUSE EXISTING WALL WAS A WOOD FRAMED STRUCTURE. | | NEED TO REVISE CONNECTORS THAT CORRESPOND TO NEW | | CONCRETE BLOCK WALL.. REVISE SECOND FLOOR FRAMING PLAN | | AND CONNECTORS THAT REFLECT REVISED CONDITIONS.NEED | | TO SPECIFY WOOD TO MASONRY CONNECTORS THAT REFLECT NEW | | PROPOSED WALL.SEE CATALOG FOR PROPER CONNECTORS TO | | BE SPECIFIED.SPECIFY ALL CONNECTORS TO VERIFY | | COMPLIANCE WITHSEC. R601.2 OF 2004 FLORIDA | | RESIDENTIAL CODE. | | | | 2- SPECIFY BEAM SIZE AND REINFORCEMENT AT OPENING AREA | | THAT CONNECTS EXISTING HOUSE WITH PROPOSED ADDITION. | | SEE COMMENTS ON PLANS SUBMITTED. | | | | 2) SHEETSREVISED ARE THREE, NOT ONE. OWES $20.00 | | REVISION FEES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-02-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-02-12 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-02-12 |
Time |
11:05 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-12-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-12-28 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-12-28 |
Time |
15:34 |
Sent To |
PC |
|
Notes |
2007-12-28 16:30:41 | RESIDENTIAL ADDITION, BUILDING REVIEW SECOND | | CHECKLIST. | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1-OWES $15.86 FOR NEW ADDITION RADON FEES. (REPEAT | | COMMENT). | | | | 2-NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | SEC. 713.13FLORIDA STATUTE.. | | | | 3-SHEET 1 OF 6: | | A)THIS BUILDING IS NOT CONSTRUCTION TYPE 3.SEE | | SEC.602.1 FBC 2004FOR CONSTRUCTION TYPES AND REVISE | | AS REQUIRED. | | | | B) SPECIFY ALL LOADS AS REQUIRED BY TABLE R301.5 OF | | 2004 FLORIDA RESIDENTIAL CODE. MISSING THESLEEPING | | AND NON SLEEPING ROOMS AND STAIRS UNIFORM DISTRIBUTED | | LIVE LOADS. PROVIDE ALL THE REQUIRED INFORMATION FROM | | TABLE R301.5. (REPEAT COMMENT). | | | | C) THIS IS NOT JUST AN ALTERATION TYPE II, BUT AN | | ADDITION AS WELL. SEE CHAPTER 9 OF 2004 FLORIDA | | EXISTING BUILDING CODE. AND REVISE INFORMATION AS | | REQUIRED. | | | | 4- SOIL TEST REPORT SUBMITTED: | | A) ENGINEERING FIRM NEEDS TO SHOWTHE FIRM'S | | CERTIFICATE OF AUTHORIZATION NUMBER AS REQUIRED BY SEC. | | 61G15-23.002 OF FLORIDA ADMINISTRATIVE CODE. | | | | B) REVISE PROPOSED ADDITION SQUARE FOOTAGE.IT'S | | NOT 900 SF. SEE PLANS FOR CORRECT SQUARE FOOTAGE. | | | | 5- ENERGY CALCULATIONS ARE TAKING THE CEILING FANS | | CREDIT. THEREFORE NEED TO SPECIFY CEILING FAN SIZES TO | | VERIFY COMPLIANCE WITH TABLE 13-607.1.A.1 OF FBC 2004. | | (REPEAT COMMENT).SIZE OF CEILING PLANS SHOWN ON PLANS | | DON'T MEET THE MINIMUM SIZES SHOWN ON TABLE | | 13-607.1.A.1 OF FBC 2004. AND, ENERGY CALCULATIONS ARE | | TAKEN FOR THE ENTIRE HOUSE. THEREFORE, NEED TO SPECIFY | | CEILING FAN SIZE ON EACH ROOM OF THE HOUSE. SEEABOVE | | TABLE FOR MIN.SIZE REQUIRED. | | | | 6-SHEET 3 OF 6:SIZE OF FOOTING SPECIFIED IN | | FOUNDATION PLAN DOESN'T MATCHSIZE SHOWN ON TYPICAL | | FOOTING ATTACHMENT. REVISE AS REQUIRED. (REPEAT | | COMMENT). | | | | 7-SHEET 4 OF 6:STAIRWAY BEARING WALL IS SHOWN | | INCORRECTLY ON 1ST FLOOR PLAN.PLAN SHOWS THE | | GUARDRAIL AND NOT THE WALL. (REPEAT COMMENT). REVISE AS | | REQUIRED. | | | | 8- SHEET5 OF 6: | | A) REVISE RAILING HEIGHT SHOWN ON STAIRSECTION AND | | STAIR PLAN.SEE SEC. R311.5.6 OF 2004 FLORIDA | | RESIDENTIAL CODE. (REPEAT COMMENT). | | | | B) NUMBER OF RISERS SHOWN (14) ARE NOT ENOUGH. | | REVISENUMBER OF RISERS AS REQUIRED AND REVISE FLOOR | | PLANS AS REQUIRED ALSO. | | | | C) SPECIFY RISER HEIGHT IN INCHES.7.67" IS NOT A | | CORRECT DIMENSION. HOW DO YOU MEASURE IT?. PROVIDE | | CORRECT DIMENSION TO VERIFY COMPLIANCE WITH SEC. | | R311.5.3 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | D) 9" TREAD REQUIRES MINIMUM 1" NOSING.2X10 TREADS | | AS SPECIFIED ON DETAILS DON'T PROVIDE THE 1" NOSING. | | SEE SEC. R311.5.3.3 OF 2004 FLORIDA RESIDENTIAL CODE | | AND REVISE AS REQUIRED. COORDINATE WITHITEM 8(B) AND | | 8(C) ABOVE. ALSO, PROVIDE SPECIFICATIONS FOR NOSING | | PROFILE TO COMPLY WITHTHIS CODE SECTION. | | | | 9- SHEET 6 OF 6: | | A) COORDINATEALLSTRUCTURALCONNECTORS SPECIFIED | | ON WALL SECTIONS AND DETAILS WITH THOSE SPECIFIED ON | | TRUSS ANCHOR SCHEDULE AND ROOF/FLOORFRAMING PLANS. | | (REPEAT COMMENT). | | | | B) WALL SECTION B-B:SIMPSON LSTA24 STRAP SPECIFIED | | TOTRANSFER LOAD TO THE EXISTING CONCRETE BLOCK WALL | | IS TOO SHORT.ALSO, NEED TO SPECIFYA WOOD TO MASONRY | | CONNECTOR. OTHERWISE PROVIDE COMPLETE DETAIL AND | | ENGINEERINGSHOWING HOW PROPOSED STRAP WILL BE NAILED | | TO RESIST THE CALCULATED LOADS.SEC. 106.1.2 CITY | | AMENDMENTS TO FBC 2004 TO VERIFY COMPLIANCE WITH | | CALCULATED LOADS OFSEC. R301 OF 2004 FLORIDA | | RESIDENTIAL CODE. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-08-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-08-27 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-08-27 |
Time |
12:41 |
Sent To |
PC |
|
Notes |
2007-08-27 12:47:26 | RESIDENTIALADDITION AND RENOVATION BUILDING REVIEW | | FIRST CHECKLIST. | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE ANDFBC | | 2004 WITH 2006/2007 REVISIONS. | | | | 1- OWES $15.86 FOR NEW ADDITION RADON FEES. | | | | 2- NEED RECORDEDNOTICE OF COMMENCEMENT AS REQUIRED BY | | SEC. 713.13 FLORIDASTATUTE. | | | | 3- PLANS NEED TO SPECIFY CONSTRUCTION TYPE AS REQUIRED | | BY SEC. 602.1 FBC 2004. | | | | 4- PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. R401.4 | | OF 2004 FLORIDA RESIDENTIAL CODE. | | | | 5- PLANS TO SPECIFY ALL LOADS, INCLUDING THE ATTIC LIVE | | LOAD AS REQUIRED BY TABLE R301.5 OF 2004 FLORIDA | | RESIDENTIAL CODE. | | | | 6- EXTERIOR ELEVATIONS NEED TO SPECIFY ROOF PITCH. SEC. | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | 7- PROVIDE COMPLETE INTERIOR BEARING WALL SECTIONBY | | STAIRWAY OPENING THAT MATCHES PLANS. SEC. 106.1.2 CITY | | AMENDMENTS TO FBC 2004. INFORMATION SUBMITTED DOESN'T | | MATCH PLANS. | | | | 8- ENERGY CALCULATIONS ARE TAKING THE CEILING FANS | | CREDIT. THEREFORE,NEED TO SPECIFY ON PLANS CEILING | | FAN SIZES TO VERIFY COMPLIANCE WITH TABLE 13-607.1.A.1 | | OF FBC 2004. | | | | 9- TRUSS PACKAGE: | | A) ARCHITECT CAN'T SIGN AND SEAL THE TRUSS PLAN. | | ARCHITECT IS REQUIRED TO REVIEW AND APPROVE TRUSS | | PACKAGE, NOT TO SIGN AND SEAL IT. | | | | B) TRUSS ENGINEER NEEDS TO ADHERE TO SEC. | | 61G15-23.002 OF FLORIDAADMINISTRATIVE CODEBY: | | * SIGNING AND SEALINGALL DRAWINGS WITH ORIGINAL | | SIGNATURE AND SEAL. | | ** PROVIDINGALL HIS INFORMATION IN ALL SHEETS. | | | | C) THIS IS A TWO STORY HOUSE.MEAN ROOF HEIGHT OF | | 15'-0" SHOWN ON ENGINEERED TRUSSES IS INCORRECT. REVISE | | AS REQUIRED. | | | | 10- SHEET 1 OF 6: | | A) SPECIFY TOTAL ROOF DEAD LOAD. LINE WAS LEFT | | BLANK. | | | | B) THIS IS NOT A LEVEL 2 ALTERATION. THIS IS AN | | ADDITION PLUS ALTERATION OF EXISTING HOUSE. SEE | | EXISTING BUILDING 2004 CODEFOR CORRECT SECTIONS TO BE | | REFERENCED AND REVISE INFORMATION AS REQUIRED. | | | | 11- SHEET 3 OF 6: | | A) SPECIFY BUCK NAIL SIZE ON TYP. WINDOW AND SLIDING | | GLASS DOOR DETAIL. SEC. 106.1.2 CITY AMENDMENTS TO FBC | | 2004. | | | | B) CLARIFY COLUMN SIZE SPECIFIED AT BOTHENDS OF | | DOOR LEADING TO THEUTILITY ROOM.DIMENSIONS SHOWN | | AND TYPE OF COLUMNS SHOWN DON'T MATCH. REVISE AS | | REQUIRED. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | C) * SIZE OF FOOTING SPECIFIED IN FOUNDATION PLAN | | DOESN'T MATCHSIZE SHOWN ON TYPICAL FOOTING | | ATTACHMENT. REVISE AS REQUIRED. | | ** ALSO,CLARIFY NUMBER OF #5 BARS TO BE USED. | | FOUNDATION PLAN INFORMATION AND DETAIL INFORMATION NEED | | TO MATCH. | | *** TYPICAL FOOTING ATTACHMENT DETAILS SHOWS 6" MIN. | | EMBEDMENT FOR #5 REBARS, WHILE SPECS ON SAME DETAIL | | CALL FOR 8". REVISE AS REQUIRED. | | | | D) SECOND FLOOR FRAMING PLAN AND TRUSS LAYOUT DON'T | | MATCH. REVISE AS REQUIRED AND SPECIFY ALL STRUCTURAL | | CONNECTORS AS REQUIRED. SEC. 106.1.2 CITY AMENDMENTS TO | | FBC 2004. | | | | E) SPECIFY DEPTH OF FLOOR TRUSSES. SEC. 106.1.2 CITY | | AMENDMENTS TO FBC 2004. | | | | 12- SHEET 4 OF 6: | | A) STAIRWAY BEARING WALL IS SHOWN INCORRECTLY. | | REVISE AS REQUIRED. | | | | B) CLARIFY IF WINDOW ON EXISTING BATHROOM WILL BE | | BLOCKED OR NOT. PLANSHOWS UNBLOCKED WINDOW. | | | | 13- SHEET 5 OF 6: | | A) ROOF FRAMING PLAN AT ENTRY PORCH DOESN'T MATCH | | TRUSS LAYOUT.REVISE AS REQUIRED AND SPECIFY CORRECT | | TRUSS CONNECTOR ACCORDING TO THE STRUCTURE ATTACHMENT, | | CONCRETE BEAM OR WOOD BEAM. SEC. 106.1.2 CITY | | AMENDMENTS TO FBC 2004. | | | | B) CONNECTORS MTS 16 AND MTSM 16 DON'T PROVIDE | | LATERAL SUPPORT. CLARIFY WHERE ARE THE LATERAL LOADS | | FOR MTSM CONNECTOR TAKEN FROM.SPECIFY CONNECTORS THAT | | PROVIDE LATERAL SUPPORT OR PROVIDE COMPLETE ENGINEERING | | ANALYSIS SHOWING HOW SPECIFIEDCONNECTORS WILL RESIST | | THE LATERAL LOADS. SEC. 106.1.2 CITY AMENDMENTS TO FBC | | 2004. | | | | C) SPECIFY HOW IS THE GUARDRAIL ATTACHED TO COMPLY | | WITH SEC. 1607.7.1 FBC 2004. | | | | D) REVISE RAILING HEIGHT SHOWN ON STEP RAILING | | DETAIL. SEE SEC R311.5.6 FBC 2004 AND STAIR SECTION | | DETAIL AND REVISE AS REQUIRED. | | | | E) INFORMATION ON STAIR TREAD DETAIL AND STAIR | | SECTION TO MATCH. REVISE NUMBER OF STRINGERS, AND RISER | | HEIGHT. | | | | F)THERE ARE TWO DIFFERENT SIZE OF FLOOR TRUSSES | | SPECIFIED ON STAIR SECTION DETAIL. REVISE AS REQUIRED. | | | | G) STAIR PLAN DOESN'T MATCH FLOOR PLAN. REVISE AS | | REQUIRED. SEE LOCATION OF INTERIOR BEARING WALL.. | | REVISE AS REQUIRED. | | | | H) FLOOR SHEATHING SPECS SHOWN ON STAIR SECTION | | DON'T MATCH SPECS SHOWN ON TYPICAL WALL SECTION. REVISE | | AS REQUIRED. | | | | I) STAIR HANDRAIL DETAIL DOESN'T MATCH STAIR | | SECTION. REVISE AS REQUIRED. | | | | 13- SHEET 6 OF 6: | | A) REVISE ROOF SHEATHINGNAIL TYPE AND SPACING | | SPECS, INCLUDING ROOF ZONE 3 IN ALL WALL SECTIONS.SEE | | SEC. R803.2.3.1 OF 2004 FLORIDA RESIDENTIALAND REVISE | | AS REQUIRED. | | | | B) REVISE FOOTING SIZE IN ALL WALL SECTIONS TO MATCH | | FOUNDATION PLAN. | | | | C) REVISE SECOND FLOOR SHEATHINGSPECS TO MATCH IN | | ALL WALL SECTIONS AND STAIR SECTION DETAIL. | | | | D) REVISE ALL TRUSS CONNECTORS.COORDINATE WITH | | ITEM 13(B) ABOVE. | | | | E) PROVIDE COMPLETE STUD SIZE ON SECOND FLOOR WALL | | FRAMING SPECS ON WALL SECTION B-B.SEC. 106.1.2 CITY | | AMENDMENTS TO FBC 2004. | | | | F) INTERIOR BEARING WALL DETAIL: WALL IS SUPPORTING | | THE SECOND FLOOR TRUSSES, NOT THE ROOF JOIST. REVISE AS | | REQUIRED. | | | | G) SPECIFICATIONS ON ENTRY PORCH SECTIONS ARE NOT | | LEGIBLE. REVISE AS REQUIRED. SAME THING APPLIES TO WALL | | SECTION C-C. | | | | H) WALL SECTION C-C: | | * REVISE TO MATCH TRUSSSECOND FLOOR LAYOUTAND | | SPECIFY ALL CONNECTORS. SEC. 106.1.2 CITY AMENDMENTS TO | | FBC 2004. | | | | 14- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | 9B-72 FOR: | | A) FLAT ROOF SYSTEM. CLEARLY SPECIFY FASTENING | | OPTION TO BE USED FROM PAGE 28 OF NOA 03-0501.02 | | SUBMITTED. | | AND, PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT | | PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL | | LIMITATION #7. | | | | B) SIMPSON OR USP STRUCTURAL CONNECTORS SPECIFIED ON | | PLANS. SUBMIT ONLY THEFLORIDA PRODUCT APPROVAL | | COVER PAGE AND PAGE SHOWING THE CONNECTOR TO SAVE | | PAPER. | | | | C) 8" PRECAST LINTELS. NOA SUBMITTED IS FOR 4", 6' & | | 12" PRECAST LINTELS, NOT 8" PRECAST LINTELS. | | | | 15- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY | | AMENDMENTS TO FBC 2004. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-02-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-02-14 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-02-14 |
Time |
13:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-12-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-12-21 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-12-21 |
Time |
08:00 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-08-15 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-15 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-08-15 |
Time |
10:45 |
Sent To |
P |
|
Notes |
2007-08-15 14:13:12 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004 | | FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH | | THE FOLLOWING: | | | | 1} FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN | | THE FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE | | INDICATE THE CODE CYCLES UNDER WHICH THIS PLAN WAS | | DESIGNED. | | | | 2} INDICATE IF THE SERVICE SHOWN ON THE PLAN IS NEW OR | | EXISTING. | | | | 3} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, | | METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED. | | | | 4} PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT | | SIZE AND TYPE PER 106.3.5.4 FBC. | | | | 5} THE PANEL SCHEDULE LISTS TWO AIR HANDLERS, 1 @ 10000 | | AND 1@ 5500 WATTS. THE CALCULATION ONLY LISTS 10000 | | WATTS OF HEAT. PLEASE CORRELATE SAME. | | | | 6} THE SPA IN THE MASTER BATHROOM IS NOT LISTED IN THE | | SCHEDULE OR IN THE CALCS. ALSO IT MUST BE GFCI | | PROTECTED PER 680.43(A)(2). | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2008-12-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-12-09 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-12-09 |
Time |
15:22 |
Sent To |
Z |
|
Notes |
2008-12-09 15:23:15 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2008-07-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-29 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-29 |
Time |
14:38 |
Sent To |
M |
|
Notes |
2008-07-29 14:39:07 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-07-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-17 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-17 |
Time |
10:30 |
Sent To |
M |
|
Notes |
2008-07-17 10:30:48 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-06-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-06-12 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-06-12 |
Time |
16:58 |
Sent To |
M |
|
Notes |
2008-06-12 16:58:23 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-03-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-25 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-25 |
Time |
13:20 |
Sent To |
B |
|
Notes |
2008-03-25 13:20:52 | TO "JGOMEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-01-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-29 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-29 |
Time |
13:25 |
Sent To |
Z |
|
Notes |
2008-01-29 13:26:41 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-12-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-12-18 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-12-18 |
Time |
12:28 |
Sent To |
Z |
|
Notes |
2007-12-18 12:29:14 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-27 |
Time |
12:47 |
Rev Time |
|
Received By |
jgomez |
Date |
2007-08-07 |
Time |
11:53 |
Sent To |
Z |
|
Notes |
2007-08-07 11:54:31 | TO ZONING, RESIDENTIAL RACK./WRT. |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
P |
Date |
2008-12-12 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2008-12-12 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2008-12-12 |
Time |
13:44 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2008-07-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-30 |
Time |
08:23 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-07-30 |
Time |
08:23 |
Sent To |
|
|
Notes |
2008-07-30 08:24:27 | REVISION TO MECH. PLAN FOR SECOND FLOOR. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2008-07-22 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-22 |
Time |
16:23 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-07-22 |
Time |
16:23 |
Sent To |
|
|
Notes |
2008-07-22 16:23:57 | REVISION TO MECHANICAL PLANS AND COOLING LOAD CAL'S. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2008-07-17 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-17 |
Time |
15:40 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-07-17 |
Time |
15:40 |
Sent To |
|
|
Notes |
2008-07-17 15:47:26 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | REVISION TO MECHANICAL PLANS AND COOLING LOAD CAL'S. | | | | *** DENIED *** | | | | 1) THE COOLING LOAD CALCULATIONS FOR ZONE #1 ARE | | CALLING FOR 33,029 TOTAL COOLING BTU'S, THE MECHANICAL | | PLAN EQUIPMENT SCHEDULE FOR SYSTEM #1 SHOWS 43,000 | | TOTAL COOLING BTU'S, THE PLANS CAN ONLY CALL FOR 15% | | MORE TOTAL COOLING BTU'S THAN THE COOLING LOAD | | CALCULATIONS, PER 2004 FBC 13-607.1.ABC.1.1.A 3.5 TON | | SYSTEM IS TO LARGE, PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2008-06-13 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-06-13 |
Time |
14:27 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-06-13 |
Time |
14:27 |
Sent To |
|
|
Notes |
2008-06-13 14:53:19 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | REVISION TO MECHANICAL PLAN. | | *** DENIED *** | | | | 1) THE COOLING LOAD CALCULATIONS WILL NEED TO BE | | REVISED AS THE ZONES BEING SERVICED BY EACH UNIT HAVE | | CHANGED, PER 2004 FBC 13-607.1.ABC.1. | | | | 2) THE FIRST FLOOR PLAN SHOWS A 12" DUCT COMING FROM | | THE SECOND FLOOR, BUT THE SECOND FLOOR PLAN SHOWS NO | | 12" DUCT GOING TO THE FIRST FLOOR, PLEASE CORRECT. | | | | 3) PLEASE LIST ALL A/C EQUIPMENT AS #1 OR #2 (AIR | | HANDLERS AND CONDENSERS). | | | | 3) THE 14X14 RETURN AIR TRANSFER GRILL IS TO SMALL FOR | | THE RETURN AIR TO PASS THROUGH FROM THE FIRST FLOOR AND | | THE MASTER SUITE, SEE 2004 FBC/R M1602.4. | | | | **2004 FBC/R M1602.4 BALANCED RETURN AIR. TRANSFER | | GRILLES SHALL USE 50 SQUARE INCHES (OF GRILLE AREA) TO | | 100 CFM (OF SUPPLY AIR) FOR SIZING THROUGH-THE-WALL | | TRANSFER GRILLES AND USING AN UNRESTRICTED 1-INCH | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER RETURN AIR | | BALANCE | | (A)HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET | | THESE REQUIREMENTS FOR PROPER BALANCED RETURN AIR | | EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY | | ROOMS, EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE | | SHALL BE INCLUDED. PER 2004 FBC/R M1602.4. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-12-21 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-12-21 |
Time |
16:08 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-12-21 |
Time |
16:08 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-08-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-08-27 |
Time |
16:57 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-08-13 |
Time |
15:49 |
Sent To |
E |
|
Notes |
2007-08-13 16:00:07 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER | | 1 CITY OF WEST PALM BEACH AMENDMENTS. | | | | *** DENIED *** | | 1) THE MECHANICAL PLANS NEED THE INFORMATION OF THE | | PERSON RESPONSIBLE FOR THE DESIGN ON THEM (BOTH PAGES. | | PER FBC 104.2.1. | | | | 2) SHOW ON MECHANICAL PLANS THE CFM'S FOR EACH OF THE | | BATHROOM EXHAUST FANS, SEE 2004 FBC/R R303.3 EXCEPTT. | | | | 3) EXISTING BATHROOM #2 REQUIRES AN EXHAUST FAN, AS | | SHOWN ON ELECTRICAL PLAN, SEE 2004 FBC/R R303.3 EXCEP. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL: [email protected]. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2008-02-12 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-02-12 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-02-12 |
Time |
11:23 |
Sent To |
E |
|
Notes |
2008-02-12 11:25:27 | NOTE: RESTAMP, NEW SHEET. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2007-12-21 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-12-21 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-12-21 |
Time |
15:10 |
Sent To |
M |
|
Notes |
2007-12-21 15:18:09 | ****************PROVISO**************** | | 708.3.4 BASE OF STACK. | | A CLEANOUT SHALL BE PROVIDED AT THE BASE OF EACH WASTE | | OR SOIL STACK. | | EXCEPTIONS: | | 1."P" TRAP CONNECTIONS WITH SLIP JOINTS OR GROUND | | JOINT CONNECTIONS, OR STACK CLEANOUTS THAT ARE NOT MORE | | THAN ONE PIPE DIAMETER SMALLER THAN THE DRAIN SERVED, | | SHALL BE PERMITTED. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-08-23 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-08-23 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-08-23 |
Time |
15:16 |
Sent To |
B |
|
Notes |
2007-08-23 16:20:22 | DENIED | | REFERENCE: | | ** FBC-2004 PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 | | RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A | | PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING | | ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT | | LOCATIONS. | | NOTE: NOT ALL WASTE AND TRAPS ARE SIZED ON SHEET 4, | | SANITARY ISOMETRIC RISER DIAGRAM. PLEASE CORRECT THIS | | ON THE RESUBMITTAL. | | | | 2. SHEET 4, SANITARY ISOMETRIC PLUMBING RISER DOES NOT | | REFLECT THE FLOOR PLAN PER FBC-2004 CHAPTER 1, THE CITY | | OF WEST PALM BEACH AMENDMENTS SECTION 106.1.1 | | INFORMATION ON CONSTRUCTION | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | BE OF SUFFICIENT CLARITY TO INDICATE THE | | LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE | | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, | | AS DETERMINED BY THE | | BUILDING OFFICIAL. PLEASE CORRECT THE FOLLOWING. | | | | A} THE RELOCATED DOUBLE BOWL KITCHEN SINK IS MISSING | | FROM THE SANITARY ISOMETRIC PLUMBING RISER DIAGRAM. | | PLEASE CORRECT THIS AND RESUBMIT. | | | | B} THE RECONFIGURED EXISTING 1ST FLOOR BATH IS MISSING | | FROM THE SANITARY ISOMETRIC PLUMBING RISER DIAGRAM. | | PLEASE CORRECT THIS AND RESUBMIT. | | | | C} THERE ARE TWO WASHING MACHINES INDICATED ON THE | | SANITARY ISOMETRIC PLUMBING RISER DIAGRAM BUT ONLY ONE | | (WASHING MACHINE) IS BEING INDICATED ON THE FLOOR PLAN. | | PLEASE CLARIFY AND CORRECT THIS ON THE RESUBMITTAL. | | | | D} THE 2ND FLOOR MASTER BATH. | | | | 3. SHEET 4, SANITARY ISOMETRIC RISER DIAGRAM THE | | RELOCATED WASHING MACHINE MUST DISCHARGE DOWNSTREAM OF | | THE WET VENTED BATHROOM PER FBC-2004, PLUMBING, SECTION | | 909.1 | | WET VENT PERMITTED: ONLY THE FIXTURES | | WITHIN THE BATHROOM GROUPS SHALL CONNECT | | TO THE WET-VENTED HORIZONTAL BRANCH | | DRAIN. ANY ADDITIONAL FIXTURES SHALL | | DISCHARGE DOWNSTREAM OF THE WET VENT. | | NOTE: ALSO THE FOLLOWING IS REQUIRED FOR THE WASHING | | MACHINE. | | | | (A) 406.3 WASTE CONNECTIONS.THE TRAP AND | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | (51MM) IN DIAMETER. THE AUTOMATIC | | CLOTHES WASHER FIXTURE DRAIN SHALL | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | DIAMETER. | | | | (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY | | TRAPPED. STANDPIPES SHALL | | EXTEND A MINIMUM OF 18 INCHES (457MM) | | AND A MAXIMUM OF 42 INCHES (1066MM) | | ABOVE THE TRAP WEIR. ACCESS SHALL BE | | PROVIDED TO ALL STANDPIPES AND DRAINS | | FOR RODDING. PLEASE INDICATE THE WASHING MACHINE | | STANDPIPE. | | | | (C) 708.7 MINIMUM SIZE. CLEANOUTS SHALL | | BE THE SAME NOMINAL SIZE AS THE PIPE | | THEY SERVE UP TO 4 INCHES (102MM) | | NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE 3 | | INCH. | | | | (D) 708.9 ACCESS. ACCESS SHALL BE | | PROVIDED TO ALL CLEANOUTS. | | NOTE: CLEANOUT FOR THE WASHING MACHINE TO BE LOCATED AT | | 4 FEET ABOVE FINNISH FLOOR (4' A.F.F.) | | | | 4. SHEET 4, SANITARY ISOMETRIC PLUMBING RISER DIAGRAM | | THE INDICATED PLUMBING TIED INTO THE 2ND FLOOR PLUMBING | | STACK ON THE !ST FLOOR IS WRONG PER FBC-2004 PLUMBING, | | SECTION 908.3 CONNECTION AT DIFFERENT | | LEVELS. WHERE THE FIXTURE DRAINS CONNECT | | AT DIFFERENT LEVELS, THE VENT SHALL | | CONNECT AS A VERTICAL EXTENTION OF THE | | VERTICLE DRAIN. THE VERTICAL DRAIN PIPE CONNECCTING THE | | TWO FIXTURE DRAINS SHALL | | BE CONSIDERED THE VENT FOR THE LOWER | | FIXTURE DRAIN, AND SHALL BE SIZED IN | | ACCORDANCE WITH TABLE 908.3. THE UPPER | | FIXTURE SHALL NOT BE A WATER CLOSET. | | | | 5. SHEET 4, SANITARY ISOMETRIC PLUMBING RISER DIAGRAM | | A VENT IS REQUIRED FOR THE 2ND FLOORMASTER BATH | | SHOWER AND TUB PER TABLE 906.1 BECAUSE THE 2 INCH TRAPS | | ARE MORE THAN 6 FEET FROM THE VENT. | | | | 6. SHEET 4, SANITARY ISOMETRIC PLUMBING RISER DIAGRAM | | A TWO-WAY CLEANOUT IS REQUIRED PER FBC-2004 PLUMBING | | SECTION 708.3.5 BUILDING DRAIN AND BUILDING SEWER | | JUNCTION. THERE SHALL BE A TWO-WAY CLEANOUT NEAR THE | | JUNCTION OF THE BUILDING DRAIN AND THE BUILDING SEWER. | | | | ********IMPORTANT INFORMATION******** | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS WHICH HAVE CHANGED, PLEASE | | INCLUDE A TRANSMITTAL LETTER INDICATING HOW EACH ITEM | | WAS ADDRESSED AND PROVIDE ONE COPY OF ALL OLD/VOIDED | | SHEETS FOR REFERENCE ONLY. | | | | **NOTE: THERE IS ONLY ONE CORRECTED DRAWING IN RED INK | | ON THE INDICATED PLAN SHEETS BY THIS PLAN EXAMINER FOR | | REFERENCE FOR RESUBMITTAL AND PLEASE REFERENCE THE | | SANITARY PLUMBING ISOMETRIC RISER DIAGRAM THAT REFLECTS | | THE FLOOR PLAN AND IS CODE COMPLIANT ATTACHED TO THESE | | COMMENTS FOR THE RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL= [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2008-01-30 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-01-30 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-01-30 |
Time |
13:15 |
Sent To |
B |
|
Notes |
2008-01-30 13:17:06 | ***APPROVED - RESUB #2***CMUD TYPE III ZONING | | DISTRICT | | | | PROVISO: PROPOSED A/C EQUIPMENT SHALL BE SCREENED IN | | COMPLIANCE WITH SECTION 94-218(D)(8) OF THE ZLDR'S | | | | | | | | | | SENT TO "B" - JG |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-12-19 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-12-19 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-12-19 |
Time |
11:46 |
Sent To |
E |
|
Notes |
2007-12-19 11:52:59 | ***FAILED - RESUB #1***CMUD TYPE III ZONING DISTRICT | | | | | | 1)LANDSCAPE PLAN IS NOT SUFFICIENT.PLEASE SUBMIT A | | LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTION 94-442 | | AND 94-445 OF THE ZLDRS.INCLUDE A DATA TABLE SHOWING | | THE REQUIRED LANDSCAPING, THE PROVIDED LANDSCAPING, THE | | LANDSCAPE TYPE, AND COMPLIANCE WITH PLANT | | SPECIFICATIONS (94-445). | | | | 2)PROPOSED A/C EQUIPMENT SHALL BE SCREENED IN | | COMPLIANCE WITH SECTION 94-218(D)(8) OF THE ZLDR'S | | (PROVIDE A DETAIL). (REPEAT COMMENT) | | | | 3)PROVIDE SQUARE FOOTAGE OF ALL PROPOSED AND | | EXISTING IMPERMEABLE SURFACE WITHIN THE FRONT YARD | | (FRONT PROPERTY LINE TO FRONT OF BUILDING).PURSUANT | | TO SECTION 94-482 OF THE ZLDRS: MUST MAINTAIN 75% OR | | 1000 SQ.FT., WHICH EVER IS LESS, OF LANDSCAPING WITHIN | | THE FRONT YARD.TOTAL IMPERMEABLE WITHIN THE FRONT | | YARD MAY NOT EXCEED 562.5 SQ.FT. | | | | 4)PURSUANT TO SECTION 94-218(D)(9) OF THE ZLDRS: | | ROOF PITCH SHALL BE NO LESS THAN 5:12. | | | | 5)ALL WINDOW AND DOOR OPENING SHALL BE IN COMPLIANCE | | WITH SECTION 94-218(D)(6) OF THE ZLDR'S.PROVIDE | | DETAILS SHOWING PLACEMENT (ALL WINDOWS SHALL BE | | RECESSED A MINIMUM OF TWO INCHES FROM THE EXTERIOR FACE | | OF THE FACADE)DETAIL SHOWING ALL WINDOWS ARE | | OPERABLE, AND ALL WINDOW/OPENINGS ARE VERTICAL OR | | SQUARE IN PROPORTION. (REPEAT COMMENT) | | | | 6)OPENINGS IN UPPER STORIES SHALL BE CENTERED | | DIRECTLY ABOVE OPENINGS IN THE FIRST STORY.OPENINGS | | SHALL BE A MINIMUM OF TWO FEET FROM BUILDING CORNERS. | | (REPEAT COMMENT) | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-08-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-08-27 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-08-09 |
Time |
10:21 |
Sent To |
E |
|
Notes |
2007-08-09 10:42:18 | ***FAILED***CMUD TYPE III ZONING DISTRICT | | | | | | | | 1)ALL WORK MUST BE IN COMPLIANCE WITH THE CITY OF | | WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | REGULATIONS, SECTION 94-218. | | | | 2)AS THE SCOPE OF WORK EXCEEDS 50% OF THE | | IMPROVEMENT VALUE, A LANDSCAPING PLAN SHALL BE SHOWN IN | | COMPLIANCE WITH SECTION 94-442 OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR'S). | | | | 3)SHOW ADJOINING PROPERTIES INCLUDING SETBACK | | DIMENSIONS FROM BUILDING TO BUILDING. | | | | 4)PROVIDE SETBACK DIMENSIONS FROM PROPOSED A/C | | EQUIPMENT TO PROPERTY LINES.PROPOSED A/C EQUIPMENT | | SHALL BE SCREENED IN COMPLIANCE WITH SECTION | | 94-218(D)(8) OF THE ZLDR'S (PROVIDE DETAIL) | | | | 5)CLARIFY SCOPE OF WORK PERTAINING TO DRIVEWAY. | | REPLACING ALL OF DRIVEWAY OR UNDER CARPORT ONLY? | | PROVIDE DIMENSIONS. | | | | 6)PLEASE PROVIDE ROOF PITCH. | | | | 7)25 - 45% OF FRONT FACADE AREA (ADDITION) SHALL | | HAVE CLEAR GLAZED MATERIAL. | | | | 8)ALL WINDOW AND DOOR OPENING SHALL BE IN COMPLIANCE | | WITH SECTION 94-218(D)(6) OF THE ZLDR'S.PROVIDE | | DETAILS SHOWING PLACEMENT (ALL WINDOWS SHALL BE | | RECESSED A MINIMUM OF TWO INCHES FROM THE EXTERIOR FACE | | OF THE FACADE)DETAIL SHOWING ALL WINDOWS ARE | | OPERABLE, AND ALL WINDOW/OPENINGS ARE VERTICAL OR | | SQUARE IN PROPORTION. | | | | 9)OPENINGS IN UPPER STORIES SHALL BE CENTERED | | DIRECTLY ABOVE OPENINGS IN THE FIRST STORY.OPENINGS | | SHALL BE A MINIMUM OF TWO FEET FROM BUILDING CORNERS. | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 | | | | | | | | SENT TO "E" - BT |
|
|