Plan Review Details - Permit 07071044
Plan Review Stops For Permit 07071044 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-08-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-22 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-22 |
Time |
08:47 |
Sent To |
|
|
Notes |
2007-08-22 08:48:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)PROVIDE ENGINEERING TO SHOW HOW THE PREFAB SLAB | | AND ANCHORING WILL COMPLY WITH FBC1609.1.3, FBC R301. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-07 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-08-07 |
Time |
16:00 |
Sent To |
M |
|
Notes |
2007-08-07 16:30:15 | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | THIS REVIEW IS FOR COMPLIANCE WITH THE 2005 NEC AND | | THE 2004 FBC, 2006 REVISION. | | | | 1} THE LOAD CALCULATION GIVEN FOR THE PANEL SERVED BY | | THE GENERATOR( 34.1 KW), EXCEEDS THE OUTPUT LOAD OF THE | | 25K GENERATOR THAT WAS SUBMITTED IN VIOLATION OF | | 702.5. | | | | 2} THE 5' SETBACK REQUIRED FOR A COMBUSTABLE SURFACE IS | | NOT BEING MAINTAINED AT THE PROPERTY LINE, IF A WOODEN | | FENCE IS OR COULD BE INSTALLED. ALSO THE BUILDING | | MATERIAL FOR THE RESIDENCE NEEDS TO BE STATED. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2007-08-13 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-08-13 |
Time |
13:10 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2007-08-13 |
Time |
13:10 |
Sent To |
B |
|
Notes |
2007-08-13 13:17:27 | DENIED | | REFERENCE: | | ** FBC-2004 FUEL GAS. | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | REQUIREMENTS. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | 1. PLEASE REFERENCE ZONING REVIEW NOTES AND ELECTRICAL | | REVIEW NOTE #2 IN REFERENCE TO PLACEMENT OF THE | | GENERATOR AND PLEASE CORRELATE THE GAS DRAWING ON THE | | RESUBMITTAL. | | | | 2. BTU LOAD OF EACH APPLIANCE AND THE | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | 402.4(33). | | NOTE: THIS INCLUDES THE EXISTING NAT/GAS SYSTEM. PLEASE | | REFERENCE THE PERMIT INFORMATION ATTACHED TO THESE GAS | | REVIEW NOTES INDICATING SAID ADDRESS HAS NAT/GAS. | | | | 3. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | NOTE: THIS INCLUDES THE EXISTING NAT/GAS SYSTEM. PLEASE | | REFERENCE THE PERMIT INFORMATION ATTACHED TO THESE GAS | | REVIEW NOTES INDICATING SAID ADDRESS HAS NAT/GAS. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-08-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-08-22 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-08-01 |
Time |
10:21 |
Sent To |
|
|
Notes |
2007-08-01 10:21:59 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-08-08 |
Time |
10:47 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2007-08-08 |
Time |
10:47 |
Sent To |
G |
|
Notes |
2007-08-08 10:49:13 | *** DENIED *** | | 1) SEE ELECTRICAL REVIEW NOTES, PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL: [email protected]. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-08-02 |
Time |
12:06 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-08-02 |
Time |
12:06 |
Sent To |
E |
|
Notes |
2007-08-02 12:09:27 | ***FAILED*** | | | | | | 1)INDICATE SETBACK DIMENSIONS ON SURVEYS FROM | | PROPOSED GENERATOR TO PROPERTY LINES.MUST BE A | | MINIMUM OF 3.5' FROM SIDE PROPERTY LINES.AS PER THE | | CITY OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | REGULATIONS, SECTION 94-305(B)(4):MECHANICAL | | EQUIPMENT MAY NOT PROJECT MORE THAN FOUR FEET INTO A | | SETBACK.(NOTE:REQUIRED SIDE SETBACK = 7.5') | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 | | |
|
|
|