Plan Review Details - Permit 07070982
Plan Review Stops For Permit 07070982
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-10-05 Cont ID  
Sent By mjacobs Date 2007-10-05 Time 08:05 Rev Time 0.00
Received By mjacobs Date 2007-10-05 Time 07:52 Sent To PC
Notes
2007-10-05 07:52:43PROCESS PLANS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-10-03 Cont ID  
Sent By mjacobs Date 2007-10-03 Time 07:24 Rev Time 0.00
Received By mjacobs Date 2007-10-03 Time 07:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-15 Cont ID  
Sent By mjacobs Date 2007-08-15 Time 11:20 Rev Time 0.00
Received By mjacobs Date 2007-08-14 Time 09:50 Sent To  
Notes
2007-08-14 13:03:14BUILDING PLAN REVIEW
 PERMIT:07070982
 ADD: 3901 36TH CT
 CONT: COUNTER-POINT CONST. CORP.
 TEL: (561)827-5327
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS
 A RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 3)2004 FBC EXISTING
 301.5A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
  
 4)THE JOB ADDRESS NEEDS TO BE ON EACH PAGE ON THE
 PLANS, THE ADDRESS SHALL INCLUED THE UNIT AND FLOOR
 NUMBER. SEE 2004 FBC, CITY WPB AMEND. 106.1.3 AND FAC
 61G1-16.004(3).
  
 5)TABLE 803.3 MINIMU M INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY.
  
 6)110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PROJECT IS DESIGNED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED
 F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED.
 G) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT
 . -------------------------------------
 ) NUMBER OF UNITS
 ) NUMBER OF FLOORS
 ) NUMBER OF BEDROOMS
 ) NUMBER OF ROOMS
 ) NUMBER OF BEDROOMS
 ) SQ. FT. LIV SPACE/ FL
 ) SQ. FT. FOOTPRINT
  
 7)FBC. 2308.8 THE GRADE AND SPECIE OF WOOD SHALL BE
 INDICATED ON THE DRAWINGS, ALONG WITH THE TYPE OF NAILS
 AND NAILING PATTERN OF THE NEW JOISTS.
  
 8)THE FLOOR LIVE LOAD SHALL BE INDICATED ON THE
 PLANS PER FBC. TABLE 1607.1
  
 9)THE TWO PERMITS APPLIED FOR HAS IDENTICAL DRAWINGS.
 HOW CAN THE VALUE BE DIFFERENT IF THE SCOPE OF WORK IS
 THE SAME?
  
 10)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-10-03 Cont ID  
Sent By mawillia Date 2007-10-03 Time 21:54 Rev Time 0.00
Received By mawillia Date 2007-10-03 Time 21:48 Sent To B1
Notes
2007-10-03 21:54:24*****APPROVED*****
  
  
 ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED;PLAN SHEET 2 OF 2 STAMPED, INITIALED,
 AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-08-23 Cont ID  
Sent By mawillia Date 2007-08-23 Time 17:59 Rev Time 0.00
Received By mawillia Date 2007-08-23 Time 17:52 Sent To  
Notes
2007-08-23 17:54:40*****UNSAT****
  
  
 1.THE UNIT NUMBER AT THE ADDRESSED PROJECT SITE SHALL
 BE IN THE TITLE BLOCK OF EACH SUBMITTED PLAN SHEET.
  
 2.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 3.SPECIFY THE INTERIOR FINISH MATERIAL FOR ANY
 REPLACED DRYWALL AND/OR CEILING IN TERMS OF CLASS A,
 CLASS B, OR CLASS C.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-17 Cont ID  
Sent By adarroug Date 2007-09-17 Time 11:37 Rev Time 0.00
Received By adarroug Date 2007-09-17 Time 11:37 Sent To  
Notes
2007-09-24 15:53:15TO "BOB"#12
2007-09-17 11:37:28WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-23 Cont ID  
Sent By mawillia Date 2007-08-23 Time 17:52 Rev Time 0.00
Received By mawillia Date 2007-08-01 Time 09:22 Sent To  
Notes
2007-08-08 19:13:41TO BOB BOARD #15
2007-08-01 09:22:29WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2007-09-28 Cont ID  
Sent By tgordon Date 2007-09-28 Time 12:01 Rev Time 0.20
Received By tgordon Date 2007-09-28 Time 12:01 Sent To  
Notes
2007-09-28 12:02:53NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME. NO MECHANICAL WORK TO BE DONE.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-08-13 Cont ID  
Sent By tgordon Date 2007-08-13 Time 11:35 Rev Time 0.20
Received By tgordon Date 2007-08-13 Time 11:34 Sent To  
Notes
2007-08-13 11:35:28PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER
 1 CITY OF WEST PALM BEACH AMENDMENTS.
  
 *** DENIED ***
 1) SUBMIT MECHANICAL PLAN SHOWING ALL DUCT-WORK WITH
 SIZES BEING REPLACED, SHOW ALL GRILLS WITH SIZES AND
 CFM'S BEING REPLACED, AND IF AIR HANDLER AND HEATER IS
 TO BE REPLACED PROVIDE EQUIPMENT LISTING.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL: [email protected].

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-13 Cont ID  
Sent By choops Date 2007-08-13 Time 17:10 Rev Time 0.00
Received By choops Date 2007-08-13 Time 17:10 Sent To  
Notes
2007-08-13 17:10:34*ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK
 DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE.