Plan Review Details - Permit 07070981
Plan Review Stops For Permit 07070981
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-10-05 Cont ID  
Sent By mjacobs Date 2007-10-05 Time 07:49 Rev Time 0.00
Received By mjacobs Date 2007-10-05 Time 07:36 Sent To PC
Notes
2007-10-05 07:49:22PROCESS PLANS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-10-03 Cont ID  
Sent By mjacobs Date 2007-10-03 Time 07:43 Rev Time 0.00
Received By mjacobs Date 2007-10-03 Time 07:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-15 Cont ID  
Sent By mjacobs Date 2007-08-15 Time 11:18 Rev Time 0.00
Received By mjacobs Date 2007-08-15 Time 06:10 Sent To  
Notes
2007-08-15 11:18:42BUILDING PLAN REVIEW
 PERMIT: 07070981
 ADD: 3901 36TH CT
 CONT: COUNTERPOINT CONST CORP.
 TEL: (561)827-5327
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS
 A RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 3)2004 FBC EXISTING
 301.5A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
  
 4)THE JOB ADDRESS NEEDS TO BE ON EACH PAGE ON THE
 PLANS, THE ADDRESS SHALL INCLUED THE UNIT AND FLOOR
 NUMBER. SEE 2004 FBC, CITY WPB AMEND. 106.1.3 AND FAC
 61G1-16.004(3).
  
 5)TABLE 803.3 MINIMU M INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY.
  
 6)110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PROJECT IS DESIGNED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED
 F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED.
 G) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT
 . -------------------------------------
 ) NUMBER OF UNITS
 ) NUMBER OF FLOORS
 ) NUMBER OF BEDROOMS
 ) NUMBER OF ROOMS
 ) NUMBER OF BEDROOMS
 ) SQ. FT. LIV SPACE/ FL
 ) SQ. FT. FOOTPRINT
  
 7)FBC. 2308.8 THE GRADE AND SPECIE OF WOOD SHALL BE
 INDICATED ON THE DRAWINGS, ALONG WITH THE TYPE OF NAILS
 AND NAILING PATTERN OF THE NEW JOISTS.
  
 8)THE FLOOR LIVE LOAD SHALL BE INDICATED ON THE PLANS
 PER FBC. TABLE 1607.1
  
 9)THE TWO PERMITS APPLIED FOR HAS IDENTICAL DRAWINGS.
 HOW CAN THE VALUE BE DIFFERENT IF THE SCOPE OF WORK IS
 THE SAME?
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-10-03 Cont ID  
Sent By mawillia Date 2007-10-03 Time 22:07 Rev Time 0.00
Received By mawillia Date 2007-10-03 Time 21:57 Sent To B1
Notes
2007-10-03 22:05:27*****APPROVED*****
  
  
 ALL COMMENTS FROM THE PREVIOUS PLAN REVIEW HAVE BEEN
 ADDRESSED;PLAN SHEET 2 OF 2 STAMPED, INITIALED, AND
 DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-08-23 Cont ID  
Sent By mawillia Date 2007-08-23 Time 17:49 Rev Time 0.00
Received By mawillia Date 2007-08-23 Time 17:32 Sent To  
Notes
2007-08-23 17:46:15*****UNSAT****
  
  
 1.THE UNIT NUMBER AT THE ADDRESSED PROJECT SITE SHALL
 BE IN THE TITLE BLOCK OF EACH SUBMITTED PLAN SHEET.
  
 2.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 3.SPECIFY THE INTERIOR FINISH MATERIAL FOR ANY
 REPLACED DRYWALL AND/OR CEILING IN TERMS OF CLASS A,
 CLASS B, OR CLASS C.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-17 Cont ID  
Sent By adarroug Date 2007-09-17 Time 11:41 Rev Time 0.00
Received By adarroug Date 2007-09-17 Time 11:41 Sent To  
Notes
2007-09-24 15:53:41TO "BOB"#12
2007-09-17 11:41:52WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-23 Cont ID  
Sent By mawillia Date 2007-08-23 Time 17:37 Rev Time 0.00
Received By mawillia Date 2007-08-01 Time 09:17 Sent To  
Notes
2007-08-08 19:12:50TO BOB BOARD #15
2007-08-01 09:18:52WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2007-09-28 Cont ID  
Sent By tgordon Date 2007-09-28 Time 12:09 Rev Time 0.20
Received By tgordon Date 2007-09-28 Time 12:09 Sent To  
Notes
2007-09-28 12:08:53MECHANICAL CONTRACTOR PROVIDED PLANS AND OBTAINED MECH.
 PERMIT #07090547.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-09-20 Cont ID  
Sent By tgordon Date 2007-08-13 Time 11:23 Rev Time 0.20
Received By tgordon Date 2007-08-13 Time 11:23 Sent To  
Notes
2007-08-13 11:30:14MECHANICAL PLANS HAVE BEEN SUBMITTED WITH MECHANICAL
 PERMIT APPLICATION #07090547

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-13 Cont ID  
Sent By choops Date 2007-08-13 Time 17:09 Rev Time 0.00
Received By choops Date 2007-08-13 Time 17:09 Sent To  
Notes
2007-08-13 17:09:18*VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.