Plan Review Details - Permit 07070946
Plan Review Stops For Permit 07070946 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-10-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-10-04 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-10-04 |
Time |
16:28 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-09-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-09-04 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-09-04 |
Time |
09:30 |
Sent To |
PC |
|
Notes |
2007-09-04 09:48:06 | SIGN BUILDING REVIEW FIRST CHECKLIST. | | REVIEW DONE UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1- SHEET A-0.1 | | A) NEED TO BE SIGNED AND SEALED BY THE ARCHITECT AS | | REQUIRED BY CHAPTER 481 FLORIDA STATUTE. | | | | B)ARCHITECT NEEDS TO PROVIDE ALL HIS INFORMATION | | IN THE TITLE BLOCK AS REQUIRED BY SEC. 61G1-16.004 OF | | FLORIDA ADMINISTRATIVE CODE. | | | | 2- ENGINEER TO PROVIDE ALL THE WIND LOAD INFORMATION AS | | REQUIRED BY SEC. 1609.1 FBC 2004 AND SPECIFY CODES FOR | | WHICH STRUCTURE WAS DESIGNED. | | | | 3- INFORMATION SUBMITTED ON SHEET A-0.1 DOESN'T MATCH | | INFORMATION SUBMITTED BY ENGINEER. REVISE AS REQUIRED | | TO MATCH. | | | | 4- PROVIDE CURRENT RECORDED NOTICE OF COMMENCEMENT AS | | REQUIRED BY SEC. 713.13 FLORIDA STATUTE. | | ***NOTE: ALSO, USE REVISED NOTICE OF COMMENCMENT FORM | | AND MAKE SURE CONTRACTOR' SINFORMATION AND COMPLETE | | SCOPE OF WORK IS PROVIDED. | | | | 5-A) ENGINEERED DRAWINGS TO PROVIDE COMPLETE SIGN | | FRAMEWORK AND CONSTRUCTION SPECIFICATIONS. SEC. 106.1.2 | | CITY AMENDMENTS TO FBC 2004. | | | | B) ENGINEERED DRAWINGS TO BE CLEAR COPIES. DRAWINGS | | SUBMITTED ARE NOT LEGIBLE. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-10-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-10-01 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-10-01 |
Time |
11:13 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-07 |
Time |
13:21 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-08-07 |
Time |
13:12 |
Sent To |
B |
|
Notes |
2007-08-07 13:21:50 | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS,2005 | | NEC, AND FOUND NONE COMPLIANT WITH THE FOLLOWING: | | | | | | 1} INDICATE PANEL DESIGNATION AND CIRCUIT NUMBERS, | | CONDUIT AND CONDUCTOR SIZE AND TYPE, AND THE LOCATION | | FOR EQUIPMENT BEING WIRED UNDER THIS PERMIT .106.5 FBC | | AS AMENDEED. | | | | 2} INDICATE COMPLIANCE WITH 600.6 FOR THE DISCONNECTING | | MEANS. | | | | 3} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417 | | FS, RESPECTIVELY | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-09-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-25 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-25 |
Time |
08:40 |
Sent To |
Z |
|
Notes |
2007-09-25 08:40:53 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-09-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-09-04 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-07-30 |
Time |
13:29 |
Sent To |
|
|
Notes |
2007-07-30 13:29:56 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-09-28 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-09-28 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-09-28 |
Time |
17:13 |
Sent To |
E |
|
Notes |
2007-09-28 17:14:30 | APPROVED PER SIGN PLAN FOR PREMIER PARK PD |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-08-02 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-08-02 |
Time |
10:20 |
Sent To |
E |
|
Notes |
2007-08-02 10:22:34 | ***FAILED*** | | | | | | 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY SHOWING | | SCOPE OF WORK AND STREETS SURROUNDING SUBJECT | | PROPERTY. | | | | 2)PLEASE INDICATE ANY EXISTING SIGNS, IF ANY, WITH: | | LOCATION, SQUARE FOOTAGE, AND SETBACKS TO PROPOSED | | SIGN. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|
|
Account Summary | Usage Policy | Privacy Policy