Plan Review Details - Permit 07070940
Plan Review Stops For Permit 07070940 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-10-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-10-02 |
Time |
11:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-10-02 |
Time |
11:15 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-09-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-09-04 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-09-04 |
Time |
10:52 |
Sent To |
PC |
|
Notes |
2007-09-04 10:57:14 | SIGN BUILDING REVIEW FIRST CHECKLIST. | | REVIEW DONE UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1- ENGINEER TO PROVIDE ALL HIS INFORMATION AS REQUIRED | | BY CHAPTER 471 FLORIDA STATUTE AND SEC. 61G15-23.002 OF | | FLORIDA ADMINISTRATIVE CODE. | | | | 2- ENGINEER TO PROVIDE ALL WIND LOAD DESIGN INFORMATION | | AS REQUIRED BYSEC. 1609.1 FBC 2004. AND ALSO SPECIFY | | CODES TO BE USED. | | | | 3- PROVIDE COMPLETE SPECIFICATIONS FOR SIGN MOUNTING TO | | RESIST WIND LOADS CALCULATED ON ITEM 2 ABOVE.CHANNEL | | LETTERS AND US PRIME LOGO. SEC. 106.1.2 CITY AMENDMENTS | | TO FBC 2004. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-09-18 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-09-14 |
Time |
06:50 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-07 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-08-07 |
Time |
13:25 |
Sent To |
B |
|
Notes |
2007-08-07 13:33:26 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | 2005 NEC,2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | NONE COMPLIANT WITH THE FOLLOWING: | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | 1} A DISCONNECTING MEANS PER 600.6 FOR THE CIRCUITS | | REQUIRED BY 600.5 SHOULD BE LOCATED ON THE PLAN. | | | | 2} THE ENGINEER WHO SIGNED AND SEALED THE PLAN MUST | | PROVIDE A TITLE BLOCK WITH INFORMATION PER | | 61G15-23.002(2) FAC. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-09-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-12 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-12 |
Time |
14:24 |
Sent To |
E |
|
Notes |
2007-09-12 14:25:03 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-09-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-09-04 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-07-30 |
Time |
13:29 |
Sent To |
|
|
Notes |
2007-07-30 13:29:18 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-08-02 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-08-02 |
Time |
09:32 |
Sent To |
E |
|
Notes |
2007-08-02 09:35:00 | PROVISO:ALL ILLUMINATED SIGNS MUST CONFORM TO THE | | CITY OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | REGULATIONS, SECTIONS 94-402(B) , 94-406 , AND ANY | | OTHER RESTRICTIONS DESIGNATED BY THE ZONING DISTRICT IN | | WHICH IT IS LOCATED. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |