Plan Review Details - Permit 07070935
Plan Review Stops For Permit 07070935
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-08-16 Cont ID  
Sent By mjacobs Date 2007-08-16 Time 08:02 Rev Time 0.00
Received By mjacobs Date 2007-08-16 Time 06:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-09-19 Cont ID  
Sent By btrobaug Date 2007-09-19 Time 07:31 Rev Time 0.00
Received By btrobaug Date 2007-09-19 Time 07:17 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-08-17 Cont ID  
Sent By btrobaug Date 2007-08-17 Time 15:20 Rev Time 0.00
Received By btrobaug Date 2007-08-17 Time 13:29 Sent To  
Notes
2007-08-17 15:38:17 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 1} FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN
 THE FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE
 INDICATE THE CODE CYCLES UNDER WHICH THIS PLAN WAS
 DESIGNED.
  
 2} INDICATE COMPLIANCE WITH CHAPTER 13
 OF THE FLORIDA BLDG CODE.
  
 3} INDICATE PANEL DESIGNATION AND CIRCUIT NUMBERS FOR
 DEVICES AND LIGHTING. 106.3.5
  
 4} } PROVIDE A PANEL SCHEDULE SO THAT BRANCH/FEEDER
 CIRCUIT CONDUCTOR AND OVER CURRENT PROTECTION
 COMPLIANCE MAY BE REVIEWED PER 106.3.5.4 FBC AS
 AMENDED.
  
 5} PROVIDE EMERGENCY ILLUMINATION PER
 NFPA-101 7.8 (2003), AND CIRCUITED PER
 700.12 NEC. INDICATE SAME ON PLANS. LOCATE THE BATTERY
 PACKS AND EXIT LIGHTS ON SHEET E-1 WITH THE LIGHTING.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2007-08-23 Cont ID  
Sent By mawillia Date 2007-08-23 Time 12:37 Rev Time 0.00
Received By mawillia Date 2007-08-23 Time 12:18 Sent To  
Notes
2007-08-23 12:36:53*****APPROVED*****
  
 PLAN SHEETS A-1 AND E-2 WERE STAMPED, INITIALED, AND
 DATED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-13 Cont ID  
Sent By adarroug Date 2007-09-13 Time 13:44 Rev Time 0.00
Received By adarroug Date 2007-09-13 Time 13:44 Sent To E
Notes
2007-09-13 13:45:10TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-23 Cont ID  
Sent By mawillia Date 2007-08-23 Time 12:37 Rev Time 0.00
Received By mawillia Date 2007-07-30 Time 11:24 Sent To  
Notes
2007-08-08 19:40:47TO BOB BOARD #18
2007-07-30 11:24:59WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2007-08-10 Cont ID  
Sent By tgordon Date 2007-08-10 Time 15:55 Rev Time 0.20
Received By tgordon Date 2007-08-10 Time 15:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-08-20 Cont ID  
Sent By mperson Date 2007-08-20 Time 14:16 Rev Time 0.33
Received By mperson Date 2007-08-20 Time 14:16 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-13 Cont ID  
Sent By choops Date 2007-08-13 Time 08:04 Rev Time 0.00
Received By choops Date 2007-08-13 Time 08:04 Sent To  
Notes
2007-08-13 08:05:10*VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.