Plan Review Stops For Permit 07070665 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-02-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-02-11 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-02-11 |
Time |
16:43 |
Sent To |
Z |
|
Notes |
2008-02-11 16:44:28 | BUILDING REVISION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-01-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-01-29 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-01-29 |
Time |
16:32 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-11-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-11-02 |
Time |
12:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-11-02 |
Time |
10:54 |
Sent To |
P |
|
Notes |
2007-11-02 12:58:41 | RESIDENTIAL REPAIRS BUILDING REVIEWPROVISO: | | | | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | 9B-72 FOR:ALL SIMPSON CONNECTORS SPECIFIED ON | | DRAWINGS BY THE ENGINEER OF RECORD. | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | PRODUCT APPROVAL REQUESTED ON ITEM 1 ABOVE AS REQUIRED | | BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | 3- ENGINEER TO SPECIFY BUILDING CONSTRUCTION TYPE AS | | REQUIRED BY 602.1 FBC 2004.NEED TO IDENTIFY IF | | CONSTRUCTION TYPE A OR B. SEE SEC. 602.1 FBC 2004. | | | | 4- TYPICAL WALL SECTION: | | A) WHERE WAS CONNECTOR MSTM16 TAKEN FROM? LOOKED IN | | 2007 SIMPSON CATALOG AND WAS UNABLE TO FIND IT TO | | VERIFY COMPLIANCE WITH PROPOSED APPLICATION. NEED A | | WOOD TO MASONRY CONNECTOR.***NOTE: KEEP IN MIND THAT | | WHEN TYPE AND NUMBER OF FASTENERS ARE DIFFERENT FROM | | THOSE TESTED AND PUBLISHED BY THE MANUFACTURER, THEN | | COMPLETE ENGINEERING ANALYSIS WILL BE REQUIRED TO SHOW | | HOW THE LOADSARE ACHIEVED. SEC. 106.1.2 CITY | | AMENDMENTS TO FBC 2004. | | | | B) ENGINEER OF RECORD NEEDS TO REVIEW PRODUCT | | APPROVALFOR HARDIPANEL SIDING AND REVISE WALL | | SHEATHING SIZE TO MATCH SIZE REQUIRED ON THE PRODUCT | | APPROVAL. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-10-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-10-03 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-10-03 |
Time |
17:09 |
Sent To |
PC |
|
Notes |
2007-10-03 18:04:14 | RESIDENTIAL REPAIRS BUILDING REVIEW SECOND CHECKLIST. | | REVIEW DONE UNDER 2004 FLORIDA RESIDENTIAL CODE AND | | 2004 FBC EXISTING BUILDINGWITH 2007 REVISIONS. | | | | 1-PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | 9B-72 FOR: | | A) NEW SINGLE HUNG WINDOWS. INFORMATION SUBMITTED IS | | NOT AN APPROVED PRODUCT APPROVAL. VISIT | | WWW.FLORIDABUILDING.ORG TO DOWNLOAD APPROVED FLORIDA | | PRODUCT APPROVALS.OR PROVIDE DADE COUNTY NOA. | | | | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | PLANS AND DETAILS.REPEAT COMMENT, NOT ADDRESSED. | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | 3- SPECIFY CONSTRUCTION TYPE AS REQUIRED BY SEC. 602.1 | | FBC 2004 AND SEC. 106.1.2CITY AMENDMENTS TO FBC 2004. | | REPEATED COMMENT, NOT ADDRESSED. | | | | 4- TYPICAL WALL SECTION; | | A) PROVIDE COMPLETE TYPICAL WALL SECTION SHOWING | | CONNECTORS ON TOP AND BOTTOM OF WOOD STUDS. SEC. | | 106.1.2 CITY AMENDMENTS TO FBC 2004. SECTION/DETAIL | | SHOWN IS INCOMPLETE. REPEAT COMMENT, NOT ADDRESSED. | | | | B) NEED TO REVISE SIMPSON TS18 CONNECTOR. THIS IS A | | WOOD TO WOOD CONNECTOR. NEED TO SPECIFY WOOD TO MASONRY | | CONNECTOR. SEE CATALOG AND REVISE AS REQUIRED. REPEAT | | COMMENT, NOT PROPERLY ADDRESSED. | | | | 5- NOTICE OF COMMENCEMENT WAS RECORDED ON 5/16/2007. IT | | EXPIRES AFTER 90 DAYS OF RECORDING IF WORK IS NOT | | STARTED. SEC. 713.13 FLORIDA STATUTE.NEED TO PROVIDE | | RE-RECORDED NOTICE OF COMMENCEMENT. | | | | 6- PLEASE DON'T STAPLE PRODUCT APPROVALS TO DRAWINGS. | | THIS WILL HELP EXPEDITE THE REVIEW PROCESS. | | | | 7- DRAWING 2 OF 2 IS NOT LEGIBLE. IS THIS DRAWING | | REALLY REQUIRED.COORDINATE INFORMATION IN THIS | | DRAWING WITHHARDIPLANK PRODUCT APPROVALTO AVOID | | CONFLICTS AND DELAYS IN THE REVIEW PROCESS. | | | | 8- SEE ZONING COMMENTS. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-08-07 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-08-07 |
Time |
16:47 |
Sent To |
P |
|
Notes |
2007-08-07 16:58:19 | BUILDING REVIEW FOR STRUCTURAL REPAIRS. | | FIRST REVIEW CHECKLIST. | | REVIEW DONE UNDER FBC 2004BUILDING WITH 2006 | | REVISIONS AND 2004 FLORIDA RESIDENTIAL CODE: | | | | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BYDCA RULE | | 9B-72 FOR: | | A) NEW EXTERIOR WINDOWS AND DOORS. | | | | B) STORM SHUTTERS, UNLESS WINDOWS AND DOORS HAVE | | HURRICANE MISSILE IMPACT GLAZINGAS REQUIRED BY SEC. | | R301.2.1.2 OF 2004 FLORIDA RESIDENTIAL CODE. ***NOTE: | | PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE ATTACHED | | SAMPLE.AND,CLEARLY CIRCLEON SHUTTERS DRAWINGS | | SPECIFIC MOUNTING CONDITIONS AND SPECIFIC ANCHOR TYPE | | AND SPACING TO BE USED. SEC. 106.1.2 CITY AMENDMENTS TO | | FBC 2004. | | | | C) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | PLANS AND DETAILS. | | | | 2- SPECIFY CONSTRUCTION TYPE AS REQUIRED BY SEC. 602.1 | | FBC 2004 AND SEC. 106.3.5.4 CITY AMENDMENTS TO FBC | | 2004. | | | | 3- TYPICAL WALL SECTION ON SHEET 1 OF 1: | | A)PROVIDE COMPLETE TYPICAL WALL SECTION SHOWING | | CONNECTORS ON TOP AND BOTTOM OF WOOD STUDS. SEC. | | 106.1.2 CITY AMENDMENTS TO FB 2004. SECTION SHOWNIS | | INCOMPLETE. | | | | B)NEED TO REVISE SIMPSON ST18 STRAP SPECIFIED ON | | TYPICAL WALL SECTION SECTION.THIS IS A WOOD TO WOOD | | CONNECTOR.NEED TO SPECIFY A WOOD TO MASONRY | | CONNECTOR.SEE CURRENT SIMPSON CATALOG AND REVISE AS | | REQUIRED.SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | C) PROVIDE COMPLETE SPECIFICATIONS FOR NEW STUCCO | | FINISH. PROVIDE COMPLETE WALL SHEATHING SPECS AND | | FASTENING, AND STUCCO FINISH AS REQUIRED BY ASTM C926 | | AND ASTM C1063. | | | | D) HOW CAN YOU RECONSTRUCT 2X4 STUD?.SEC. 106.1.2 | | CITY AMENDMENTS TO FBC 2004. | | | | 4- PROVIDEENERGY CALCULATIONSAS REQUIRED BY SEC. | | 13-600.1.C.2 FBC 2004. | | | | 5- SPECIFY SIZE AND TYPE OF WINDOW TO BE REPLACED AT | | BEDROOM WINDOW TO VERIFY COMPLIANCE WITH EGRESS | | REQUIREMENTS.SEC. 405 FBC 2004 EXISTING BUILDING. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2008-02-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-02-08 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-02-08 |
Time |
10:57 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2008-01-24 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-24 |
Time |
17:04 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-01-24 |
Time |
16:41 |
Sent To |
P |
|
Notes |
2008-01-24 17:04:04 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} THE REVISIONSUBMITTED NOW HAS A TANKLESS ELECTRIC | | WATER HEATER WITH OCP IN A CLOTHES CLOSET IN VIOLATION | | OF 240.24(D). REMOVE FROM CLOSET. | | | | 2} THE LOAD CALCULATIONWAS NOT REVISED TO INDICATE THE | | NEW LOAD, REVISE SAME PER ARTICLE 220. | | | | 3} SUBMIT TWO COPIES OF THE MANUFACTURER'S | | SPECIFICATIONS, THAT INCLUDE THE ELECTRICAL | | SPECIFICATIONS, FOR THE WATER HEATER. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-10-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-10-23 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-10-23 |
Time |
13:08 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-09-24 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-09-24 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-09-24 |
Time |
17:01 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2007-08-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-06 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-07-26 |
Time |
13:34 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-02-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-05 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-05 |
Time |
13:08 |
Sent To |
E |
|
Notes |
2008-02-05 13:09:19 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-01-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-22 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-22 |
Time |
10:17 |
Sent To |
E |
|
Notes |
2008-01-22 10:18:11 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-10-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-17 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-17 |
Time |
16:22 |
Sent To |
Z |
|
Notes |
2007-10-17 16:22:36 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-09-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-18 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-18 |
Time |
11:31 |
Sent To |
Z |
|
Notes |
2007-09-18 11:32:11 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2007-08-07 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2007-07-23 |
Time |
15:38 |
Sent To |
|
|
Notes |
2007-07-23 15:42:14 | TO "E" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2008-02-11 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-02-11 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-02-11 |
Time |
13:59 |
Sent To |
B |
|
Notes |
2008-02-11 14:00:48 | REVISION SHEET 1: "OK" |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2008-01-29 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-29 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-29 |
Time |
13:42 |
Sent To |
B |
|
Notes |
2008-01-29 13:54:44 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2006 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | PLUMBING PLAN REVIEW: | | REVISION DENIED: | | | | 1. SHEET 1, SANITARY PLUMBING RISER DIAGRAM: THE | | BATHROOM GROUP IS NOT VENTED. PER FBC PLUMBING SECTION | | *909.1 WET VENT PERMITTED. | | | | 2. SHEET 1, SANITARY PLUMBING RISER DIAGRAM: THE | | SHOWER NEEDS A WATER-SEAL TRAP. PER FBC PLUMBING | | SECTION *1002.1 FIXTURE TRAPS. | | | | 3.ALL CHANGES TO THE PLAN ARE TO BE CLOUDED WITH | | REVISION NUMBERS/DATES PER FBC-2004 CHAPTER 1, SECTION | | 106.1.3 THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND | | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS | | RECORD RETENTION PROGRAM. | | NOTE: A TRANSMITTAL LETTER IS HELPFUL. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | EXAMINER FOR REFERENCE FOR THE | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2007-11-05 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-11-05 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-11-05 |
Time |
08:01 |
Sent To |
PC |
|
Notes |
2007-11-05 08:11:22 | ****************PROVISO**************** | | DUE TO THE SITUATION OF THE OWNERS BEING DISPLACED FROM | | THE RESIDENCE BECAUSE OF DAMAGE DUE TO VEHICLE | | COLLISION AN AS BUILT CODE COMPLIANT SANITARY ISOMETRIC | | RISER DIAGRAM WILL BE REQUIRED BEFORE A FINAL | | INSPECTION. PER FBC-2004, PLUMBING, SECTION 909.1 WET | | VENT PERMITTED: ONLY THE FIXTURES WITHIN THE BATHROOM | | GROUPS SHALL CONNECT TO THE WET-VENTED HORIZONTAL | | BRANCH DRAIN. ANY ADDITIONAL FIXTURES SHALL DISCHARGE | | DOWNSTREAM OF THE WET VENT. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2007-10-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-10-30 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-10-30 |
Time |
11:31 |
Sent To |
B |
|
Notes |
2007-10-30 11:38:22 | DENIED | | REFERENCE: | | ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE (FAC). | | ** FLORIDA STATUTES (FS). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE ON THE | | RESUBMITTED PLANS: | | | | 1. SHEET 1, SANITARY RISER DIAGRAM IS INDICATING THE | | WASHING MACHINE WRONG PER FBC-2004, PLUMBING, SECTION | | 909.1 | | WET VENT PERMITTED: ONLY THE FIXTURES | | WITHIN THE BATHROOM GROUPS SHALL CONNECT | | TO THE WET-VENTED HORIZONTAL BRANCH | | DRAIN. ANY ADDITIONAL FIXTURES SHALL | | DISCHARGE DOWNSTREAM OF THE WET VENT. | | | | ********IMPORTANT INFORMATION******** | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | TRANSMITTAL LETTER INDICATING HOW EACH | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | EXAMINER FOR REFERENCE FOR THE | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-10-03 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-10-03 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-10-03 |
Time |
09:15 |
Sent To |
B |
|
Notes |
2007-10-03 09:45:50 | DENIED 2ND TIME | | REFERENCE: | | ** FBC-2004 WITH 05 &O6 REVISIONS, PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE (FAC). | | ** FLORIDA STATUTES (FS). | | | | 1. NOTE: PER ZONING COMMENTS ON ORIGINAL RECORDS SHOWS | | ORIGINAL CONSTRUCTION OF A RESIDENCE AND A COTTAGE (TWO | | SEPERATE BUILDINGS) CONNECTED WITH AN OPEN PORCH. | | SURVEY SUBMITTED SHOWS AS A DUPLEX WITHIN ONE | | STRUCTURE. PLEASE PROVIDE PROOF (PERMIT RECORD) OF A | | LEGAL CONVERSION. | | | | 2. PER FBC-2004 W/05 & 06 REV., PLUMBING TABLE 403.1 | | (R-3) ONE- AND TWO-FAMILY DWELLINGS THE MINIMUM FIXTURE | | REQUIREMENTS FOR THE DUPLEX ARE PER THE FOLLOWING. | | | | A} WATER CLOSET= 1 PER DWELLING UNIT. | | B} LAVATORIES= 1 PER DWELLING UNIT. | | C} BATHTUBS/SHOWERS= 1 PER DWELLING UNIT. | | D} KITCHEN SINK= 1 PER DWELLING UNIT. | | E} AUTOMATIC CLOTHES WASHER CONNECTOR= 1 PER DWELLING | | UNIT. | | | | NOTE: THE INDICATED UNIT ON THE PLANS DOES NOT HAVE A | | LAVATORY OR AN AUTOMATIC CLOTHES WASHER CONNECTOR | | INDICATED ON THE PLANS. PLEASE PROVIDE PROOF (PERMIT | | RECORD) OF A LEGAL CONVERSION. | | | | **END OF COMMENTS** | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-08-08 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-08-08 |
Time |
10:37 |
Sent To |
PC |
|
Notes |
2007-08-08 11:08:55 | DENIED | | REFERENCE: | | ** FBC-2004 PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | 1. MORE INFORMATION IS REQUIRED DUE TO THE FACT THAT A | | PLUMBING PERMIT IS BEING APPLIED FOR. | | | | A} IF PLUMBING LAYOUT IS THE SAME | | WITH NO CHANGES, PLEASE INDICATE THIS ON | | THE RESUBMITTED DRAWING. | | | | B} IF PLUMBING LAYOUT IS THE | | SAME AND THE PLUMBING FIXTURES ARE TO BE | | CHANGED, PLEASE INDICATE ON THE RESUBMITTED DRAWING. | | "EXACT FIXTURE CHANGE OUT ONLY." | | | | C} IF THE NEW PROPOSED PLUMBING LAYOUT IS DIFFERENT | | FROM THE EXISTING PLEASE INDICATE ON A SEPERATE FLOOR | | PLAN DRAWINGS THE EXISTING FLOOR PLAN LAYOUT AND THE | | NEW PROPOSED BATHROOM PLUMBING LAYOUT AND FOLLOW WHAT | | IS REQUIRED IN COMMENT #2. | | | | 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 | | RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A | | PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING | | ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT | | LOCATIONS. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL= [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-10-22 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-10-22 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-10-22 |
Time |
14:05 |
Sent To |
E |
|
Notes |
2007-10-22 14:08:45 | ***APPROVED - RESUB #2*** | | | | SENT TO "E" - BT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-09-20 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-09-20 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-09-20 |
Time |
13:46 |
Sent To |
E |
|
Notes |
2007-09-20 13:49:34 | ***FAILED - RESUB #1*** | | | | | | 1)ORIGINAL RECORDS SHOW ORIGINAL CONSTRUCTION OF A | | RESIDENCE AND A COTTAGE (TWO SEPARATE BUILDINGS) | | CONNECTED WITH A OPEN PORCH.SURVEY SUBMITTED SHOWS AS | | A DUPLEX WITHIN ONE STRUCTURE.PLEASE PROVIDE PROOF | | (PERMIT RECORD) OF THE LEGAL CONVERSION. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-07-27 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-07-27 |
Time |
17:29 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-07-27 |
Time |
17:29 |
Sent To |
E |
|
Notes |
2007-07-27 17:30:48 | ***FAILED*** | | | | | | 1)PLEASE PROVIDE A CURRENT SURVEY SHOWING THE SCOPE | | OF WORK WITH SETBACK DIMENSIONS TO THE PROPERTY LINES. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|