Plan Review Details - Permit 07070617
Plan Review Stops For Permit 07070617
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-09-07 Cont ID  
Sent By jgomez Date 2007-09-07 Time 10:52 Rev Time 0.00
Received By jgomez Date 2007-09-07 Time 07:41 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-10 Cont ID  
Sent By jgomez Date 2007-08-10 Time 12:53 Rev Time 0.00
Received By jgomez Date 2007-08-10 Time 12:39 Sent To PC
Notes
2007-08-10 15:02:24SIGN BUILDING REVIEW FIRSTCHECKLIST.
 REVIEW UNDER FBC 2004.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 2- ENGINEERED DRAWING SHEET #1 IS MISSING THE
 DIMENSIONS FOR THE SIGN.ENGINEERED DRAWINGS TO HAVE
 ALL THE INFORMATION INCLUDING SIGN DIMENSIONS. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 3- ACCORDING TOSECTION THRU CABINET DETAIL ON SHEET
 #1, THESIGN IS TO HAVE (3) 3/8" X 1-1/2" SLEEVE
 ANCHORS.PROVIDE ENGINEERING CALCULATIONS SHOWING HOW
 ONLY THREE ANCHORS ARE ADEQUATE TO RESIST THE WIND
 LOADS SPECIFIEDON ITEM #9 OF DESIGN, FABRICATION AND
 CONSTRUCTION NOTES ON SHEET # 1AND THE SIZE OF THE
 SIGN. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 4-"HEART OF THE SYSTEM"DETAIL SHOWN ON SHEET #1
 STATES THAT STAINLESS OR GALVANIZED STAPLESHOLD
 SECURELY IN WINDS UP TO 110MPH.NEED TO PROVIDE DESIGN
 THAT HOLDS FOR AT LEAST 148MPH AS SPECIFIED ON ITEM #9
 OF THE DESIGN, FABRICATION AND CONSTRUCTION NOTES ON
 SHEET #1.
  
 5- ENGINEER'S SEAL HAS THE WRONG NUMBER IMPRESSED ON
 THE SEAL.CORRECT ENGINEER LICENSE NUMBER IS 26818,
 NOT 20818. REVISE SEAL AS REQUIRED.
  
 6- ENGINEER TO PROVIDE HIS LICENSE NUMBER IN ALL SHEETS
 AS REQUIRED BY CHAPTER 471 FLORIDA STATUTE AND SEC.
 61G15-23.002 OF CITY ADMINISTRATIVE CODE.LOOK ON
 WEBSITE FOR FOR THIS SECTIONS AND PROVIDE ALL
 INFORMATION AS REQUIRED.
  
 7- UPDATE ALL REFERENCE STANDARDS AND YEAR AS ADOPTED
 BY FBC 2004.SEE CHAPTER 35 OF FBC 2004 AND REVISE
 ALL SPECIFIED STANDARDS AND EDITIONSSPECIFIED ON
 SHEET #1 AS REQUIRED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-09-06 Cont ID  
Sent By btrobaug Date 2007-09-06 Time 12:53 Rev Time 0.00
Received By btrobaug Date 2007-09-06 Time 12:51 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-07-27 Cont ID  
Sent By btrobaug Date 2007-07-27 Time 11:40 Rev Time 0.00
Received By btrobaug Date 2007-07-27 Time 11:36 Sent To B
Notes
2007-07-27 11:40:44 
  
 B MISC #3./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-04 Cont ID  
Sent By adarroug Date 2007-09-04 Time 10:14 Rev Time 0.00
Received By adarroug Date 2007-09-04 Time 10:14 Sent To Z
Notes
2007-09-04 10:15:11TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-10 Cont ID  
Sent By jgomez Date 2007-08-10 Time 15:02 Rev Time 0.00
Received By jgomez Date 2007-07-23 Time 08:47 Sent To  
Notes
2007-07-23 08:47:20TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2007-09-05 Cont ID  
Sent By choops Date 2007-09-05 Time 09:44 Rev Time 0.00
Received By choops Date 2007-09-05 Time 09:44 Sent To E
Notes
2007-09-05 09:44:50PROVISO: ALL ILLUMINATED SIGNS MUST CONFORM TO THE CITY
 OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS, SECTIONS 94-402(B) , 94-406 , AND ANY
 OTHER RESTRICTIONS DESIGNATED BY THE ZONING DISTRICT IN
 WHICH IT IS LOCATED.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-24 Cont ID  
Sent By choops Date 2007-07-24 Time 08:57 Rev Time 0.00
Received By choops Date 2007-07-24 Time 08:57 Sent To E
Notes
2007-07-24 08:58:19***FAILED***
  
  
 1)PLEASE PROVIDE BUILDING HEIGHT.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720