Plan Review Details - Permit 07070593
Plan Review Stops For Permit 07070593
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-09-11 Cont ID  
Sent By shill Date 2007-09-11 Time 11:35 Rev Time 0.00
Received By shill Date 2007-09-11 Time 11:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-26 Cont ID  
Sent By shill Date 2007-08-26 Time 14:14 Rev Time 0.00
Received By shill Date 2007-08-26 Time 14:14 Sent To  
Notes
2007-08-26 14:17:23****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)SEE OPENING 2.YOU STATE THAT YOU ARE DESIGNING
 TO -77PSF, BUT 47.2 REQUIRES 6" SPACING FOR PANELS, C2
 CONNECTION, 2" EDGE DISTANCE (7" FOR 3" EDGE DISTANCE).
 SPECIFY EDGE DISTANCE AND REVISE ANCHOR SPACING.
  
 2.)OPENING 1, ACCORDION, STATES ANCHOR SPACING IS 4"
 BUT ON SHEET 7 YOU'VE WRITTEN "DRILLED EVERY 10
 INCHES".4" IS REQUIRED.PLEASE REMOVE THE NOTE OR
 CLARIFY AS TO WHAT THIS MEANS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-13 Cont ID  
Sent By shill Date 2007-08-13 Time 11:58 Rev Time 0.00
Received By shill Date 2007-08-13 Time 11:58 Sent To  
Notes
2007-08-13 11:59:18****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT
 OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16.
  
 ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 ____3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT, FBC*106.
  
 ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____6.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3
 ABOVE.
  
 _XX_8.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-09-06 Cont ID  
Sent By adarroug Date 2007-09-06 Time 15:38 Rev Time 0.00
Received By adarroug Date 2007-09-06 Time 15:38 Sent To B
Notes
2007-09-06 15:38:58TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-21 Cont ID  
Sent By adarroug Date 2007-08-21 Time 10:22 Rev Time 0.00
Received By adarroug Date 2007-08-21 Time 10:22 Sent To B
Notes
2007-08-21 10:23:07TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-13 Cont ID  
Sent By shill Date 2007-08-13 Time 11:59 Rev Time 0.00
Received By shill Date 2007-07-20 Time 10:37 Sent To  
Notes
2007-07-20 10:38:00TO "MISC" BOX#1