Plan Review Details - Permit 07070579
Plan Review Stops For Permit 07070579
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-08-13 Cont ID  
Sent By jgomez Date 2007-08-13 Time 11:55 Rev Time 0.00
Received By jgomez Date 2007-08-13 Time 11:55 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-07-26 Cont ID  
Sent By btrobaug Date 2007-07-26 Time 13:22 Rev Time 0.00
Received By btrobaug Date 2007-07-26 Time 13:15 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2007-08-06 Cont ID  
Sent By mperson Date 2007-08-06 Time 11:05 Rev Time 0.00
Received By mperson Date 2007-08-06 Time 11:05 Sent To  
Notes
2007-08-06 11:06:49NOTE: THE IS NO POOL HEATER (GAS OR ELECTRIC).

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-08-23 Cont ID  
Sent By adarroug Date 2007-08-23 Time 14:25 Rev Time 0.00
Received By adarroug Date 2007-08-23 Time 14:25 Sent To Z
Notes
2007-08-23 14:25:44TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-16 Cont ID  
Sent By adarroug Date 2007-08-16 Time 08:45 Rev Time 0.00
Received By adarroug Date 2007-08-16 Time 08:45 Sent To Z
Notes
2007-08-16 08:45:19TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-13 Cont ID  
Sent By jgomez Date 2007-08-13 Time 12:02 Rev Time 0.00
Received By jgomez Date 2007-07-20 Time 09:26 Sent To  
Notes
2007-07-20 09:26:59TO "Z" BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-08-29 Cont ID  
Sent By mperson Date 2007-08-29 Time 15:43 Rev Time 0.00
Received By mperson Date 2007-08-29 Time 15:43 Sent To PC
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-08-20 Cont ID  
Sent By mperson Date 2007-08-20 Time 10:56 Rev Time 0.33
Received By mperson Date 2007-08-20 Time 10:56 Sent To PC
Notes
2007-08-20 11:10:58DENIED 2ND TIME
 REFERENCE:
 ** FBC-2004 PLUMBING.
 **FBC-2004 SECTION 424.2 OR R4101 SWIMMING POOLS.
  
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 1. SHEETS 1 AND 2, THE RESUBMITTED PLANS WITH THE HAND
 WRITTEN CHANGES ON THE 3-MIN. JETS: PER CHAPTER 471 THE
 ENGINEER OF RECORD RONALD GLORSKY P.E.#13220, MUST SIGN
 AND DATE THESE HAND WRITTEN CHANGES AND DOCUMENT THESE
 CHANGES IN REVISIONS: ON BOTH SHEETS.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-08-06 Cont ID  
Sent By mperson Date 2007-08-06 Time 10:49 Rev Time 0.33
Received By mperson Date 2007-08-06 Time 10:48 Sent To G
Notes
2007-08-06 11:05:39DENIED
 REFERENCE:
 ** FBC-2004 SECTIONS 424.2 OR R4101 SWIMMING POOLS.
 ** FBC-2004 PLUMBING.
 ** FBC-2004 FUEL GAS.
 ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION
 REQUIREMENTS.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. PLEASE ADD THE 3- MIN. JETS TO THE POOL
 SPECIFICATIONS ON PAGE 1 AND PLEASE ADD AND CLARIFY HOW
 THEY WILL PIPED ON THELEGEND ON PAGE 2 FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2007-08-27 Cont ID  
Sent By choops Date 2007-08-27 Time 14:20 Rev Time 0.00
Received By choops Date 2007-08-27 Time 14:20 Sent To P
Notes
2007-08-27 14:21:51***APPROVED******RESUB #2***
  
 SENT TO MP

Review Stop Z ZONING
Rev No 2 Status F Date 2007-08-16 Cont ID  
Sent By choops Date 2007-08-16 Time 13:31 Rev Time 0.00
Received By choops Date 2007-08-16 Time 13:31 Sent To P
Notes
2007-08-16 13:32:40***FAILED******RESUB #1***
  
  
 1)PLEASE INDICATE SETBACK DIMENSION FROM EDGE OF
 POOL EQUIPMENT TO THE SIDE PROPERTY LINE.(REPEAT
 COMMENT)
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-23 Cont ID  
Sent By choops Date 2007-07-23 Time 13:18 Rev Time 0.00
Received By choops Date 2007-07-23 Time 13:18 Sent To E
Notes
2007-07-23 13:19:17***FAILED***
  
  
 1)AS THE SURVEY DOES NOT SHOW AN EXISTING FENCE
 SURROUNDING THE POOL, A FENCE PERMIT SHALL BE SUBMITTED
 CONCURRENTLY AND SHALL CONFORM TO THE MINIMUM STANDARDS
 PROVIDED BELOW.
  
 AS PER THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B)+(C):
  
 B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE
 OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT
 ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF
 THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
 C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE
 THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND
 SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR
 WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF
 GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL
 SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH
 WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT
 SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.
  
 2)INDICATE POOL EQUIPMENT SETBACK DIMENSIONS FROM
 PROPERTY LINES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720


Account Summary | Usage Policy | Privacy Policy