Plan Review Stops For Permit 07070568 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-09-11 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-09-11 |
Time |
08:30 |
Sent To |
PC |
|
Notes |
2007-09-11 08:48:40 | PROCESS PLAN. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-09-06 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-09-06 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-09-06 |
Time |
10:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-08-08 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-08-08 |
Time |
14:35 |
Sent To |
PC |
|
Notes |
2007-08-08 15:58:43 | BUILDING PLAN REVIEW | | PERMIT: 07070568 | | ADD: 1617 N. FLAGLER DR. #502 | | CONT: KENNETH M. SALUACCI INC. | | TEL: (561)684-7459 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW: 1ST | | ACTION: DENIED | | | | 1) -- VERYIMPORTANT STATEMENT-- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | 2)2004 FBC EXISTING | | 301.5A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | | 3)ALL PLANS SUBMITTED AFTER OCTOBER, 1ST 2004 SHALL | | BE DESIGNED TO THE 2004 FBC / WITH 2006 REVISIONS. | | INDICATE THIS INFORMATION ON THE DRAWINGS. | | | | 4)SUBMIT AN EXISTING FLOOR PLAN AND A PROPOSED FLOOR | | PLAN CLEARLY INDICATING WHERE ALL THE CHANGES ARE | | MADE. | | | | 5)SUBMIT A FINISH SCHEDULE MEETING THE REQUIREMENTS | | OF FBC 803 / 804 AND 805. INDICATE THE FLAME SPREAD AND | | SMODE-DEVELOPED INDEX OF THE ROOMS ECT. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-09-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-09-06 |
Time |
07:37 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-09-06 |
Time |
06:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-08-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-03 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-08-03 |
Time |
07:48 |
Sent To |
|
|
Notes |
2007-08-03 14:24:49 | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003 | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT. | | | | 1} PROVIDE A PANEL SCHEDULE SO THAT OVERCURRENT | | PROTECTION AND WIRE SIZES PER 310.16 CAN BE REVIEW, AND | | REQUIRED CIRCUITS PER 210.11 CAN BE VERIFIED AS | | COMPLIANT | | | | 2} THE ISLAND RECEPTACLE(S) MUST COMPLY WITH | | 210.52(C)(2). THE RECEPTACLE 16" FROM THE FLOOR WILL | | NOT MEET THE REQUIREMENT, ALSO GFCI IS REQUIRED PER | | 210.8(A)(6). | | | | 3} A SMOKE ALARM NEEDS TO BE ADDED OUTSIDE THE MASTER | | BEDROOM TO MEET THE INTENT OF R313.1.1" OUTSIDE EACH | | SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE | | BEDROOMS" | | | | PER 2704.1, 2004 FBC, METAL FRAMING MEMBERS SHALL BE | | BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR THE | | CIRCUIT THAT MAY ENERGIZE THE FRAMING. PLEASE PUT A ON | | THE PLAN FOR CLARITY IN THE FIELD. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2007-09-10 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-09-10 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-09-10 |
Time |
13:18 |
Sent To |
B1 |
|
Notes |
2007-09-10 13:35:43 | *****APPROVED***** | | | | | | ALL PREVIOUS FIRE PLAN REVIEW COMMENTS HAVE BEEN | | ADDRESSED;PLAN SHEET STAMPED, INITIALED, AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-08-07 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-08-07 |
Time |
13:30 |
Sent To |
|
|
Notes |
2007-08-07 14:06:06 | *****DENIED***** | | | | | | 1.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | REFERENCED. | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 3.THE REMOVAL AND/OR THE REPLACEMENT OF BUILDING | | MATERIALS & SUPPLIES SHALL NOT INTERFERE OR HINDER | | ACCESS TO OR EGRESS FROM THE 5TH FLOOR CORRIDOR OR ANY | | OTHER FLOOR IN THE BUILDING. | | | | 4.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | 5.SPECIFY THE INTERIOR FINISH MATERIALS FOR THE | | PROPOSED WALLS IN TERMS OF CLASS A, CLASS B, OR CLASS | | C. | | | | 6.DOORS SHALL BE NOT LESS THAN 78 INCHES IN NOMINAL | | HEIGHT.PLEASE EXPLAIN/CLARIFY DIMENSION OF THE | | PROPOSED CLOSET DOORS. | | | | 7.PLEASE INDICATE IF THE UNIT SPACE'S SMOKE DETECTION | | DEVICES ARE ACTUALLY SMOKE DETECTORS OR SMOKE ALARMS. | | PLEASE BE ADVISED THAT SMOKE DETECTORS (SD) ARE TIED | | INTO THE BUILDING'S FIRE ALARM SYSTEM WHEREAS SMOKE | | ALARMS (SA) ALERT THE OCCUPANT(S) OF THE UNIT SPACE | | ONLY. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE ON THE PLANS EACH ITEM WAS | | ADDRESSED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-21 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-21 |
Time |
16:25 |
Sent To |
|
|
Notes |
2007-08-31 10:50:32 | TO "BOB"#12 | 2007-08-21 16:25:37 | WAITING FOR "BOB" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-08-08 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-19 |
Time |
14:21 |
Sent To |
|
|
Notes |
2007-07-30 09:08:59 | TO "BOB"#16 | 2007-07-19 14:21:46 | WAITING FOR "BOB" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-07-30 |
Time |
13:45 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-07-30 |
Time |
13:45 |
Sent To |
|
|
Notes |
2007-07-30 13:45:51 | NO MECHANICAL PLANS SUBMITTED, AND NO | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | THIS TIME. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-08-02 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-08-02 |
Time |
08:31 |
Sent To |
|
|
Notes |
2007-08-02 08:31:22 | *VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | IMPROVEMENT VALUE. |
|
|