Plan Review Details - Permit 07070546
Plan Review Stops For Permit 07070546
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-10-02 Cont ID  
Sent By rmcdouga Date 2007-10-02 Time 09:41 Rev Time 0.00
Received By rmcdouga Date 2007-10-02 Time 09:41 Sent To  
Notes
2007-10-02 09:45:27BUILDING PROVISO
  
 SUBMIT PRODUCT APPROVALS FOR IMPACT RATED WINDOW
 MULLION (APPROVED BY THE DESIGNER OF RECORD) FOR REVIEW
 BEFORE INSTALLATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-07 Cont ID  
Sent By rmcdouga Date 2007-08-07 Time 09:28 Rev Time 0.00
Received By rmcdouga Date 2007-08-06 Time 19:20 Sent To P
Notes
2007-08-07 13:02:482004 FBC WITH 2006 REVISIONS
 REMODEL SFR AND CONVERT PORTION OF GARAGE TO CABANA
  
 DENIED BY BUILDING
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED. CHANGE OF USE
 FROM GARAGE TO CABANA MAY REQUIRE PAYMENT IMPACT FEES
 TO PALM BEACH COUNTY.
  
 2) SPECIFY THE SCOPE OF WORK ON THE PLANS. SEE FBC
 *106.1.1 OF THE CITY OF WPB AMENDMENTS TO THE 2004
 FBC.
  
  
 3) SPECIFY THE APPLICABLE BUILDING CODES AND DESIGN
 DATA ON THE PLANS. SPECIFY WIND SPEED, EXPOSURE
 CATEGORY, IMPORTANCE FACTOR, COMPONENT AND CLADDING
 PRESSURES, ETC. SEE FBCR301.SPECIFY THE SCALE OF
 THE DRAWINGS ON THE PLANS PER FBC* 106.1.2.
  
 4) INDICATE ON THE PLANS THAT THE WINDOWS AND DOORS
 ARE BEING REPLACED. NOTE: THIS IS NOT INDICATED ON THE
 WORK DESCRIPTION ON THE PERMIT APPLICATION.
  
 5) SPECIFY THE SIZES OF THE WINDOWS AND DOORS ON THE
 PLANS.
  
 6) THE STRUCTURAL WORK ON THIS PROJECT AT THE
 CONVERSION OF THE EXISTING GARAGE TO COVERED PORCH AND
 CABANA EXCEEDS THE PRESCRIPTIVE LIMITATIONS OF THE
 CODE. THEREFORE, ENGINEERED DESIGN IS REQUIRED BY A
 FLORIDA LICENSED DESIGN PROFESSIONAL. SEE R301.1.3 AND
 FBC* 106.1.
  
 7) SPECIFY THE REQUIRED BEARING CAPACITY OF THE SOIL
 FOR THE DESIGN. SEE FBC* 106.1.2AND R 401.4.1.
  
 8) SPECIFY HOW THE NEW WALL, COLUMNS AND BEAM AT THE
 GARAGE WILL BE TIED INTO THE EXISTING WALL. FBC*
 106.1.2
  
 9) SPECIFY THE LIVE AND DEAD LOADS FOR THE FLOORS OF
 THE REMODELED BATHROOMS AND THE FLAT AND SLOPED ROOFS
 AT THE GARAGE.
  
 10) PROVIDE A FLOOR PLAN OF THE EXISTING HOUSE AND
 GARAGE. SHOW ALL EXISTING WALLS AND LABEL ALL ROOMS.
  
 11) NO HANDWRITING IS ALLOWED ON THE PLANS. ALL CHANGES
 TO THE PLANS ARE REQUIRED TO BE DATED AND INITIALED BY
 THE DESIGNER OF RECORD.
  
 12) THE NAME OF THE PERSON RESPONSIBLE FOR THE DESIGN
 IS REQUIRED ON EACH SHEET ALONG WITH THEIR SIGNATURE.
 FBC* 106.1
  
 13) PLEASE CLARIFY THE EXTENT OF STRUCTURAL WORK THAT
 IS BEING DONE IN THE EXISTING BATHROOMS.
  
 14) IN ORDER TO MAKE PLANS MORE CLEAR, INDICATE THE
 LOCATION OF THE SECTION DETAILS ON THE FLOOR PLANS,
 FOUNDATION PLANS OR ROOF PLANS WITH SECTION ID TAGS
 (FOR EXAMPLE 1ON A4.)LABEL THE SECTION DETAIL
 DRAWINGS WITH CORRESPONDING TAGS. FBC* 106.1.1
  
 15) SPECIFY HOW THE NEW BARREL TILEWILL BE ATTACHED
 TO THE OVERHANG. SEE TILE NOA FOR OPTIONS.
  
 16) SEE RED PENCIL NOTES ON THE PLANS REQUESTING
 MISSING INFORMATION SUCH AS SPACING OF STUDS AT NEW
 FRAME GARAGE WALL, EMBED DEPTH OF ANCHOR BOLTS, ETC.
  
 17)SUBMIT MANUFACTURER'S SPECIFICATIONS AND LISTING
 INFORMATION FOR THE BBQ THAT WILL ALLOW IT TO BE USED
 UNDER A COMBUSTIBLE CEILING.
  
 18) SUBMIT PRODUCT APPROVALS FOR THE ROOF COVERING
 MATERIALS, GLASS BLOCK, SIMPSON CONNECTORS AND EXTERIOR
 SWING PANEL DOOR AT THE GARAGE SHOWN ON A3.
  
 19)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-09-13 Cont ID  
Sent By btrobaug Date 2007-09-13 Time 09:00 Rev Time 0.00
Received By btrobaug Date 2007-09-13 Time 07:58 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-07-23 Cont ID  
Sent By btrobaug Date 2007-07-23 Time 07:41 Rev Time 0.00
Received By btrobaug Date 2007-07-23 Time 07:20 Sent To M
Notes
2007-07-23 07:41:05 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} } PER 110.9 AND 110.10: OBTAIN THE
 AVAILABLE FAULT CURRENT AT THE UTILITY
 AND CALCULATE THE SAME AT THE EQUIPMENT.
 INDICATE THE AIC RATING FOR THE
 EQUIPMENT IS EQUAL TO OR GREATER THAN
 THE AVAILABLE FAULT.
  
 2} INDICATE HOW THE MAIN HOUSE IS BEING FED. THE PLAN
 SHOWS ONLY ONE PANEL LOCATION. PLEASE LOCATE ALL
 SERVICE EQUIPMENT ON THE PLAN, METER ENCLOSURE,
 DISCONNECTS AND PANELS, SO THAT COMPLIANCE WITH
 ARTICLES 225 AND 230 CAN BE REVIEWED.
  
 3} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE
 PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI
 PROTECTED PER 210.8(A) (1). INDICATE SAME ON THE PLAN.
  
 4} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME, ALL SHEETS, PER
 106.3.4.3.FBC.
  
 5} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN
 INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE ALARMS
 SHALL BE INTERCONNECTED AND HARD WIRED INDICATE
 LOCATIONS AND INTENT ON THE PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2007-07-17 Cont ID  
Sent By swurafti Date 2007-07-17 Time 16:13 Rev Time 0.00
Received By swurafti Date 2007-07-17 Time 16:13 Sent To  
Notes
2007-07-17 16:13:46HISTORIC APPROVED BY JPAPA

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-10 Cont ID  
Sent By adarroug Date 2007-09-10 Time 13:58 Rev Time 0.00
Received By adarroug Date 2007-09-10 Time 13:58 Sent To Z
Notes
2007-09-10 13:59:07TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-10 Cont ID  
Sent By jleech Date 2007-08-10 Time 09:34 Rev Time 0.00
Received By jleech Date 2007-07-19 Time 09:18 Sent To  
Notes
2007-07-19 09:18:20TO "SFR" Z"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-09-13 Cont ID  
Sent By tgordon Date 2007-09-13 Time 09:52 Rev Time 0.30
Received By tgordon Date 2007-09-13 Time 09:52 Sent To P
Notes
2007-09-13 09:58:18*** PROVISO ***
 1) BATHROOM EXHAUST FAN MAY NOT DISCHARGE NEAR THE
 OUTDOOR KITCHEN.
 2004 FBC/R R303.4.2 EXHAUST OPENINGS. OUTSIDE EXHAUST
 OPENINGS SHALL BE LOCATED SO AS NOT TO CREATE A
 NUISANCE. EXHAUST AIR SHALL NOT BE DIRECTED ONTO
 WALKWAYS.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-07-24 Cont ID  
Sent By tgordon Date 2007-07-24 Time 09:50 Rev Time 0.25
Received By tgordon Date 2007-07-24 Time 09:50 Sent To P
Notes
2007-07-24 10:01:58*** DENIED ***
 1) PLEASE SUBMIT DETAILED MANUFACTURER'S
 SPECIFICATION'S AND INSTALLATION INSTRUCTIONS FOR WHAT
 APPEARS TO BE A GAS GRILL IN THE OUTDOOR KITCHEN.
  
 2) SHOW ON PLANS WERE THE CLOTHES DRYER IN THE CABANA
 WILL VENT TO, SEE 2004 FBC/R M1501.1.
  
 3) PLEASE SHOW ON PLANS THAT THE BATHROOM EXHAUST FANS
 WILL VENT TO THE OUTDOORS, SEE 2004 FBC/R 1506.2.
  
 4) PLEASE ADD A DETAIL TO THE PLANS SHOWING THE
 DISTANCES FROM THE GAS GRILL TO COMBUSTIBLES INCLUDING
 THE ROOF.
  
 5)ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE PRINTED NAME AND
 SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. PER
 FBC 104.2.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-09-25 Cont ID  
Sent By jleech Date 2007-09-25 Time 14:12 Rev Time 0.00
Received By jleech Date 2007-09-25 Time 14:12 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-08-10 Cont ID  
Sent By jleech Date 2007-08-10 Time 09:23 Rev Time 0.00
Received By jleech Date 2007-08-10 Time 09:23 Sent To  
Notes
2007-08-10 09:32:34DENIED;
 1. THE PERSON RESPOSIBLE FOR DRAWINGS MUST SIGN AND
 PRINT HIS OR HER NAME.
 2. FLAT DRAWING SHOW TUB AND SHOWER ONE WAY THE RISER
 DIAGRAM SHOWS THEM SWITCHED.
 3. PLEASE PROVIDE MORE INFORMATION. I.E. WHAT FIXTURES
 WILL BE CHANGED OUT, LIKE FOR LIKE, IS THE TUB AND
 SHOWER IN THE SAME BATHROOMS OR ARE THEY CHANGING?
 WHERE IS SINK LOCATED ON PORCH?
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 2 Status P Date 2007-09-12 Cont ID  
Sent By choops Date 2007-09-12 Time 11:01 Rev Time 0.00
Received By choops Date 2007-09-12 Time 11:00 Sent To E
Notes
2007-09-12 11:04:03PROVISO:POOL TO BE PERMITTED SEPARATELY.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-20 Cont ID  
Sent By choops Date 2007-07-20 Time 10:38 Rev Time 0.00
Received By choops Date 2007-07-20 Time 10:38 Sent To E
Notes
2007-07-20 10:46:13***FAILED***
  
  
 1)PLEASE PROVIDE TWO (2) COPIES OF ALL SUBMITTED
 PLANS (SURVEYS).
  
 2)POOL/POOL EQUIPMENT SHOWN ON PLANS, BUT NOT
 INCLUDED IN SCOPE OF WORK.CLARIFY, IF NOT...POOL TO
 BE UNDER SEPARATE PERMIT.
  
 3)AS THE BUILDING SEPARATION REQUIREMENT IS 6' AND A
 STRUCTURAL INTRUSION MAY ENCROACH NO MORE THAN 3' INTO
 A REQUIRED SETBACK...THE PROPOSED OVERHANG EXCEEDS THE
 MAXIMUM OF 3'.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720