Plan Review Details - Permit 07070490
Plan Review Stops For Permit 07070490
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-08-17 Cont ID  
Sent By jgomez Date 2007-08-17 Time 14:10 Rev Time 0.00
Received By jgomez Date 2007-08-17 Time 14:10 Sent To PC
Notes
2007-08-17 14:21:29BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- THE BARRIER REQUIREMENTS APPLIES TO ACCESS TO THE
 POOL FROM THE HOUSE AND FROM THE OUTSIDE. SEC. R4101.17
 OF 2004 FLORIDA RESIDENTIAL CODE 2004.NEED TO COMPLY
 WITH BOTH REQUIREMENTS PRIOR TO C.O.
  
 2- WINDOWS ADJACENT TO THE POOL(60" HORIZONTALLY OF
 THE POOL EDGE)SHALL COMPLY WITH SECTION R308.4(9) OF
 2004 FLORIDA RESIDENTIAL CODE. SEE ATTACHED COPY.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-10 Cont ID  
Sent By jgomez Date 2007-08-10 Time 18:20 Rev Time 0.00
Received By jgomez Date 2007-08-10 Time 18:20 Sent To PC
Notes
2007-08-10 18:31:19NEW POOL FIRST BUILDING REVIEW CHECKLIST:
 REVIEW DONE UNDER CHAPTER 41 OF 2004 FLORIDA
 RESIDENTIAL CODE AND FBC 2004.
  
 1- DRAWING ON SHEET 1 OF 2 IS NOT DRAWN TO SCALE. NEED
 TO DRAW TO TRUE SCALE TO VERIFY COMPLIANCE WITH
 SETBACKS AND DISTANCE FROM POOL TO BUILDING. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 2- PROVIDE INFORMATION IF THERE ARE ANY WINDOWS ON WALL
 ADJACENT TO THE POOL IN THE EXISTING GARAGE AREA TO
 VERIFY COMPLIANCE WITH SAFETY GLAZING REQUIREMENTS OF
 SEC. R308.4(9).
  
 3-A) SPECIFY ALL DIMENSIONS TO VERIFY COMPLIANCE WITH
 SEC. R4101.18REGARDING STEPS OR BENCHES.
  
 B) NEED TO PROVIDE STEPS OR BENCH AT DEEP AREA AS
 REQUIRED BY THE ABOVE SECTION ON ITEM 3(A).
  
 4- NOTES REGARDING SWIMMING POOL BARRIER REQUIREMENTS
 NEED TO BE REVISED.
 A) NOTE #1 IS TO IMPEDE ACCESS FROM THE HOUSE TO THE
 POOL, NOT FROM THE POOL TO THE HOUSE. REVISE AS
 REQUIRED. SEE SEC. R4101.17 OF 2004 FLORIDA RESIDENTIAL
 CODE.
  
 B) THE BARRIER REQUIREMENTS APPLIES TO THE ACCESS
 FROM THE HOUSE TO THE POOLAND FROM THE ACCESS FROM
 OUTSIDE TO THE POOL. CLEARLY SPECIFY HOW COMPLYING WITH
 BOTH AS REQUIRED BY SEC. 4101.17 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 5- THIS IS A RESIDENTIAL POOL, THEREFORE CODE TO BE
 REFERENCED IS 2004 FLORIDA RESIDENTIALCODE CHAPTER
 41. REVISE ALL NOTES AS REQUIRED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-08-15 Cont ID  
Sent By btrobaug Date 2007-08-15 Time 13:36 Rev Time 0.00
Received By btrobaug Date 2007-08-15 Time 13:32 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-07-20 Cont ID  
Sent By btrobaug Date 2007-07-20 Time 13:24 Rev Time 0.00
Received By btrobaug Date 2007-07-20 Time 13:19 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2007-08-06 Cont ID  
Sent By mperson Date 2007-08-06 Time 09:14 Rev Time 0.00
Received By mperson Date 2007-08-06 Time 09:14 Sent To B
Notes
2007-08-06 09:16:08NOTE: THERE IS NO POOL HEATER (ELECTRIC OR GAS).

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2007-07-17 Cont ID  
Sent By ssherman Date 2007-07-17 Time 13:12 Rev Time 0.00
Received By ssherman Date 2007-07-17 Time 13:12 Sent To  
Notes
2007-07-17 13:12:24HISTORICAL APPROVAL PER JILLIAN PAPA

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-14 Cont ID  
Sent By adarroug Date 2007-08-14 Time 09:40 Rev Time 0.00
Received By adarroug Date 2007-08-14 Time 09:40 Sent To Z
Notes
2007-08-14 09:41:16TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-10 Cont ID  
Sent By jgomez Date 2007-08-10 Time 18:31 Rev Time 0.00
Received By jgomez Date 2007-07-18 Time 14:36 Sent To  
Notes
2007-07-18 14:37:03TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-08-17 Cont ID  
Sent By mperson Date 2007-08-17 Time 11:36 Rev Time 0.33
Received By mperson Date 2007-08-17 Time 11:36 Sent To B
Notes
2007-08-17 11:41:20****************PROVISO****************
 FBC-2004 SEC. 424.2.7.2, OR
 FBCR-2004 SEC. R4101.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK.
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-08-06 Cont ID  
Sent By mperson Date 2007-08-06 Time 09:04 Rev Time 0.33
Received By mperson Date 2007-08-06 Time 09:04 Sent To G
Notes
2007-08-06 09:12:53DENIED
 REFERENCE:
 ** FBC-2004 SECTION 424.2 OR R4101 SWIMMING POOLS.
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 1. NOTE: PLEASE REFERENCE ZONING COMMENTS IN RELATION
 TO POOL EQUIPMENT PLACEMENT AND COMPLY ON THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2007-08-15 Cont ID  
Sent By choops Date 2007-08-15 Time 09:22 Rev Time 0.00
Received By choops Date 2007-08-15 Time 09:22 Sent To E
Notes
2007-08-15 09:22:56PAVER DECK NOT TO CAUSE DRAINAGE ONTO ADJACENT
 PROPERTY.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-20 Cont ID  
Sent By choops Date 2007-07-20 Time 10:33 Rev Time 0.00
Received By choops Date 2007-07-20 Time 10:33 Sent To E
Notes
2007-07-20 10:36:39***FAILED***
  
  
 1)POOL EQUIPMENT TOO CLOSE TO REAR PROPERTY LINE.
 MECHANICAL EQUIPMENT MAY ENCROACH 4' INTO ANY REQUIRED
 SETBACK.THE REQUIRED REAR SETBACK FOR PRINCIPAL
 BUILDING IS 13'...THEREFORE THE POOL EQUIPMENT MAY NOT
 BE CLOSER THAN 9' TO THE REAR PROPERTY LINE.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720